Correction-less dosimetry of nonstandard photon fields: a new criterion to determine the usability of radiation detectors.

Abstract:

:In the IAEA-AAPM dosimetry formalism, detector measurements in general nonstandard conditions are corrected using the factor k(f(clin),f(msr))(Q(clin),Q(msr)). This factor needs to be evaluated on a case-by-case basis which is difficult to accomplish in practice. The present paper aims to provide a method that allows neglecting correction factors for small and composite IMRT fields by first determining a radiation detector's usability in these fields. Detailed models of nine radiation detectors are built: four ionization chambers (NE2571, A12, A1SL, A14), three small field detectors (PTW31018 microLion, PTW60003 natural diamond, PTW60012 unshielded diode) and two near water-equivalent detectors (alanine, W1 scintillating fiber). Using the egs_chamber Monte Carlo code, dose response functions at 6 MV and 25 MV are sampled for each detector and their corresponding volume of water. These functions are then used with a newly derived criterion to evaluate an upper bound ξ(f(ns),f(msr))(Q(ns),Q(msr)) on the variable ε(f(ns),f(msr))(Q(ns),Q(msr)) if no field collimation/modulation occurs over a given perturbation zone. The variable ε(f(ns),f(msr))(Q(ns),Q(msr)) is defined as the absolute value of the relative deviation from unity of a nonstandard field quality correction factor k(f(ns),f(msr))(Q(ns),Q(msr)). Using the same criterion, perturbation zones are evaluated by finding the smallest field size allowed for correction-less dosimetry with a given tolerance ξ(f(ns),f(msr))(Q(ns),Q(msr)). For composite fields, the sensitivity of detectors to the non-uniformity of virtual symmetric collapsed beams over regions of interest specified by the criterion is studied to estimate an upper bound ξ ̃(f(ns),f(ref))(Q(ns),Q) on ε(f(ns),f(ref))(Q(ns),Q) for a given beam flatness. Finally, a newly defined perturbation function is used to minimize the perturbations of the microLion chamber through density compensation. The theoretical criterion shows good agreement with full Monte Carlo simulations of ε(f(ns),f(msr))(Q(ns) Q(msr)). Perturbation zones are shown to be sensitive to both the energy of the beam and the orientation of the detector. The density-compensated microLion shows significantly improved response in both axial and radial orientations in small and composite IMRT fields. Finally, the new Exradin W1 scintillator is shown to have ξ(f(ns),f(msr))(Q(ns),Q(msr)) values under 1% in small fields. The methods presented in this work theoretically show that correction-less dosimetry of nonstandard field can be accomplished by knowing the limit of usability of radiation detectors in these conditions. Potential applications include small field output factor measurements and absolute absorbed dose to water verification in the QA of clinical IMRT fields.

journal_name

Phys Med Biol

authors

Kamio Y,Bouchard H

doi

10.1088/0031-9155/59/17/4973

subject

Has Abstract

pub_date

2014-09-07 00:00:00

pages

4973-5002

issue

17

eissn

0031-9155

issn

1361-6560

journal_volume

59

pub_type

杂志文章
  • Dosimetric verification in participating institutions in a stereotactic body radiotherapy trial for stage I non-small cell lung cancer: Japan clinical oncology group trial (JCOG0403).

    abstract::A multicentre phase II trial of stereotactic body radiotherapy for T1N0M0 non-small cell lung cancer was initiated in Japan as the Japan Clinical Oncology Group trial (JCOG0403). Before starting the trial, a decision was made to evaluate the treatment machine and treatment planning in participating institutions to min...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/51/21/002

    authors: Nishio T,Kunieda E,Shirato H,Ishikura S,Onishi H,Tateoka K,Hiraoka M,Narita Y,Ikeda M,Goka T

    更新日期:2006-11-07 00:00:00

  • Improved correction for the tissue fraction effect in lung PET/CT imaging.

    abstract::Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this 'tissue fraction effect' (TFE). In this paper, we extend ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7387

    authors: Holman BF,Cuplov V,Millner L,Hutton BF,Maher TM,Groves AM,Thielemans K

    更新日期:2015-09-21 00:00:00

  • A thin target approach for portal imaging in medical accelerators.

    abstract::A new thin-target method (patent pending) is described for portal imaging with low-energy (tens of keV) photons from a medical linear accelerator operating in a special mode. Low-energy photons are usually produced in the accelerator target, but are absorbed by the target and flattening filter, both made of medium- or...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/016

    authors: Tsechanski A,Bielajew AF,Faermann S,Krutman Y

    更新日期:1998-08-01 00:00:00

  • Optimizing the planning of intensity-modulated radiotherapy.

    abstract::A method of computing optimized intensity-modulated beam profiles has been further developed and used to generate highly conformal radiotherapy dose distributions. The features of these distributions are shown to be strongly dependent on the tuning built into the algorithm. The optimization aims to achieve a specified...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/12/007

    authors: Webb S

    更新日期:1994-12-01 00:00:00

  • Physical mechanisms of gas and perfluoron retinopexy and sub-retinal fluid displacement.

    abstract::Injection of gas into the eye, followed by face-down positioning, is a common protocol for the reseating of the retina in posterior and superior retinal tears and breaks. The physical mechanism by which injected gas helps reattach retinal flaps is often ascribed to the 'buoyancy' force of the injected gas bubble. The ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/13/015

    authors: Foster WJ,Chou T

    更新日期:2004-07-07 00:00:00

  • NTCP modelling and pulmonary function tests evaluation for the prediction of radiation induced pneumonitis in non-small-cell lung cancer radiotherapy.

    abstract::This work aims to evaluate the predictive strength of the relative seriality, parallel and Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) models regarding the incidence of radiation pneumonitis (RP), in a group of patients following lung cancer radiotherapy and also to examine their correlati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/013

    authors: Tsougos I,Nilsson P,Theodorou K,Kjellén E,Ewers SB,Jarlman O,Lind BK,Kappas C,Mavroidis P

    更新日期:2007-02-21 00:00:00

  • Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale.

    abstract::Heterogeneity corrections for radiotherapy dose calculations are based on the electron density of the disturbing heterogeneity. However, when CT planning a radiotherapy treatment, where metallic hip implants are present, considerable artefacts are seen in the images. Often, an additional problem arises whereby no info...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/11/308

    authors: Coolens C,Childs PJ

    更新日期:2003-06-07 00:00:00

  • The effect of temporal HU variations on the uncertainty of dose recalculations performed on MVCT images.

    abstract::Over the course of radiation therapy, a patient's anatomy may change substantially. The relatively recent addition of frequent in-room imaging to assist with patient localization has provided a database of images that may be used to recalculate dose distributions for adaptive radiotherapy purposes. The TomoTherapy Hi-...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/24/010

    authors: Pukala J,Meeks SL,Bova FJ,Langen KM

    更新日期:2011-12-21 00:00:00

  • Liver-ultrasound based motion modelling to estimate 4D dose distributions for lung tumours in scanned proton therapy.

    abstract::Motion mitigation strategies are crucial for scanned particle therapy of mobile tumours in order to prevent geometrical target miss and interplay effects. We developed a patient-specific respiratory motion model based on simultaneously acquired time-resolved volumetric MRI and 2D abdominal ultrasound images. We presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa26

    authors: Giger AT,Krieger M,Jud C,Duetschler A,Salomir R,Bieri O,Bauman G,Nguyen D,Weber DC,Lomax AJ,Zhang Y,Cattin PC

    更新日期:2020-07-28 00:00:00

  • Dictionary learning for data recovery in positron emission tomography.

    abstract::Compressed sensing (CS) aims to recover images from fewer measurements than that governed by the Nyquist sampling theorem. Most CS methods use analytical predefined sparsifying domains such as total variation, wavelets, curvelets, and finite transforms to perform this task. In this study, we evaluated the use of dicti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/15/5853

    authors: Valiollahzadeh S,Clark JW,Mawlawi O

    更新日期:2015-08-07 00:00:00

  • Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition.

    abstract::In CT imaging, a variety of applications exist which are strongly SNR limited. However, in some cases redundant data of the same body region provide additional quanta. Examples in dual energy CT, the spatial resolution has to be compromised to provide good SNR for material decomposition. However, the respective spectr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/21/8567

    authors: Bruder H,Raupach R,Sunnegardh J,Allmendinger T,Klotz E,Stierstorfer K,Flohr T

    更新日期:2015-11-07 00:00:00

  • The influence of penetrating radiation on collimator performance.

    abstract::Geometric and penetration responses of a multihole focusing collimator to a point source have been determined using a digital computer and a ray tracing technique. Results are presented as point and line spread functions for collimated rays and penetrating rays, and as plane sensitivities and modulation transfer funct...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/1/011

    authors: Jahns MJ

    更新日期:1981-01-01 00:00:00

  • Energy-resolved computed tomography: first experimental results.

    abstract::First experimental results with energy-resolved computed tomography (CT) are reported. The contrast-to-noise ratio (CNR) in CT has been improved with x-ray energy weighting for the first time. Further, x-ray energy weighting improved the CNR in material decomposition CT when applied to CT projections prior to dual-ene...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/20/002

    authors: Shikhaliev PM

    更新日期:2008-10-21 00:00:00

  • The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact.

    abstract::The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling;...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9a2f

    authors: Simon JC,Sapozhnikov OA,Kreider W,Breshock M,Williams JC,Bailey MR

    更新日期:2018-01-09 00:00:00

  • Development of a GSO positron/single-photon imaging detector.

    abstract::We have developed and tested a GSO (gadolinium oxyorthosilicate) position-sensitive gamma detector which can be used with positron and single-photon radionuclides for imaging breast cancer or sentinel lymph node detection. Because GSO has a relatively good energy resolution for annihilation gammas as well as low energ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/2/018

    authors: Yamamoto S,Matsumoto K,Senda M

    更新日期:2006-01-21 00:00:00

  • Treatment time reduction for large thermal lesions by using a multiple 1D ultrasound phased array system.

    abstract::To generate large thermal lesions in ultrasound thermal therapy, cooling intermissions are usually introduced during the treatment to prevent near-field heating, which leads to a long treatment time. A possible strategy to shorten the total treatment time is to eliminate the cooling intermissions. In this study, the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/9/307

    authors: Liu HL,Chen YY,Yen JY,Lin WL

    更新日期:2003-05-07 00:00:00

  • Predicting voxel-level dose distributions for esophageal radiotherapy using densely connected network with dilated convolutions.

    abstract::This work aims to develop a voxel-level dose prediction framework by integrating distance information between PTV and OARs, as well as image information, into a densely-connected network (DCNN). Firstly, a four-channel feature map, consisting of a PTV image, an OAR image, a CT image, and a distance image, is construct...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba87b

    authors: Zhang J,Liu S,Yan H,Li T,Mao R,Liu J

    更新日期:2020-10-21 00:00:00

  • Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.

    abstract::A method to measure the detector-to-object distance from the images obtained with stationary high-spatial-resolution gamma-ray cameras for in vivo studies has been developed. It exploits the shift of the imaged object in the image plane, obtained at a certain tilt of the parallel-hole collimator. A linear dependence o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/N04

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Bollini D,de Notaristefani F

    更新日期:2006-05-07 00:00:00

  • Respiratory liver motion estimation and its effect on scanned proton beam therapy.

    abstract::Proton therapy with active scanning beam delivery has significant advantages compared to conventional radiotherapy. However, so far only static targets have been treated in this way, since moving targets potentially lead to interplay effects. For 4D treatment planning, information on the target motion is needed to cal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/7/1779

    authors: Zhang Y,Boye D,Tanner C,Lomax AJ,Knopf A

    更新日期:2012-04-07 00:00:00

  • Scatter compensation methods in 3D iterative SPECT reconstruction: a simulation study.

    abstract::Effects of different scatter compensation methods incorporated in fully 3D iterative reconstruction are investigated. The methods are: (i) the inclusion of an 'ideal scatter estimate' (ISE); (ii) like (i) but with a noiseless scatter estimate (ISE-NF); (iii) incorporation of scatter in the point spread function during...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/8/011

    authors: Beekman FJ,Kamphuis C,Frey EC

    更新日期:1997-08-01 00:00:00

  • Characterization of diffraction-enhanced imaging contrast in breast cancer.

    abstract::Diffraction-enhanced imaging (DEI) is a new x-ray imaging modality that has been shown to enhance contrast between normal and cancerous breast tissues. In this study, diffraction-enhanced imaging in computed tomography (DEI-CT) mode was used to quantitatively characterize the refraction contrasts of the organized stru...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/019

    authors: Kao T,Connor D,Dilmanian FA,Faulconer L,Liu T,Parham C,Pisano ED,Zhong Z

    更新日期:2009-05-21 00:00:00

  • On the validity of 3D polymer gel dosimetry: I. reproducibility study.

    abstract::The intra- and inter-batch accuracy and precision of MRI (polyacrylamide gelatin gel fabricated at atmospheric conditions) polymer gel dosimeters are assessed in full 3D. In the intra-batch study, eight spherical flasks were filled with the same polymer gel along with a set of test tubes that served as calibration pha...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/1/19

    authors: Vandecasteele J,De Deene Y

    更新日期:2013-01-07 00:00:00

  • Improving source detection and separation in a spatiotemporal Bayesian inference dipole analysis.

    abstract::Most existing spatiotemporal multi-dipole approaches for MEG/EEG source localization assume that the dipoles are active for the full time range being analysed. If the actual time range of activity of sources is significantly shorter than the time range being analysed, the detectability, localization and time-course de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/004

    authors: Jun SC,George JS,Plis SM,Ranken DM,Schmidt DM,Wood CC

    更新日期:2006-05-21 00:00:00

  • Influence of source parameters on large-field electron beam profiles calculated using Monte Carlo methods.

    abstract::The purpose of this paper was to study the source model for a Monte Carlo simulation of electron beams from a medical linear accelerator. In a prior study, a non-divergent Gaussian source with a full-width at half-maximum (FWHM) of 0.15 cm was successful in predicting relative dose distributions for electron beams wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/007

    authors: Weinberg R,Antolak JA,Starkschall G,Kudchadker RJ,White RA,Hogstrom KR

    更新日期:2009-01-07 00:00:00

  • Diaphragm correction factors for free-air chamber standards for air kerma in x-rays.

    abstract::At present, only a correction factor for photon transmission, k(l), is systematically applied for the entrance diaphragm of free-air chamber standards for air kerma. In the present work, the Monte Carlo code PENELOPE is used to re-evaluate k(l) for the BIPM standards and new correction factors are calculated for photo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/009

    authors: Burns DT,Kessler C

    更新日期:2009-05-07 00:00:00

  • The dosimetric impact of dental implants on head-and-neck volumetric modulated arc therapy.

    abstract::This work aims to investigate the dosimetric impact of dental implants on volumetric modulated arc therapy (VMAT) for head-and-neck patients and to evaluate the effectiveness of using the material's electron-density ratio for the correction. An in-house Monte Carlo (MC) code was utilized for the dose calculation to ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/1027

    authors: Lin MH,Li J,Price RA Jr,Wang L,Lee CC,Ma CM

    更新日期:2013-02-21 00:00:00

  • Energy response of optically stimulated luminescent dosimeters for non-reference measurement locations in a 6 MV photon beam.

    abstract::Optically stimulated luminescent dosimeters (OSLDs) are becoming increasingly popular for measuring an absorbed dose in clinical radiotherapy. OSLDs have known energy dependence, and this is accounted for by either calibrating the OSLD with a specific nominal energy, or using a standard energy correction factor to acc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2505

    authors: Scarboro SB,Followill DS,Kerns JR,White RA,Kry SF

    更新日期:2012-05-07 00:00:00

  • Mapping initial and general recombination in scanning proton pencil beams.

    abstract::The ion recombination is examined in parallel-plate ionization chambers in scanning proton beams at the Danish Centre for Particle Therapy and the Skandion Clinic. The recombination correction factor k s is investigated for clinically relevant energies between 70 MeV and 244 MeV for dose rates below 400 Gy min-1 in ai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8579

    authors: Christensen JB,Almhagen E,Stolarczyk L,Liszka M,Hernandez GG,Bassler N,Nørrevang O,Vestergaard A

    更新日期:2020-06-05 00:00:00

  • Stability analysis of a deterministic dose calculation for MRI-guided radiotherapy.

    abstract::Modern effort in radiotherapy to address the challenges of tumor localization and motion has led to the development of MRI guided radiotherapy technologies. Accurate dose calculations must properly account for the effects of the MRI magnetic fields. Previous work has investigated the accuracy of a deterministic linear...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa959a

    authors: Zelyak O,Fallone BG,St-Aubin J

    更新日期:2017-12-14 00:00:00

  • Three-dimensional optical tomography of the premature infant brain.

    abstract::For the first time, three-dimensional images of the newborn infant brain have been generated using measurements of transmitted light. A 32-channel time-resolved imaging system was employed, and data were acquired using custom-made helmets which couple source fibres and detector bundles to the infant head. Images have ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/23/303

    authors: Hebden JC,Gibson A,Yusof RM,Everdell N,Hillman EM,Delpy DT,Arridge SR,Austin T,Meek JH,Wyatt JS

    更新日期:2002-12-07 00:00:00