A method to reconstruct intra-fractional liver motion in rotational radiotherapy using linear fiducial markers.

Abstract:

:Complex intra-fractional motion and deformation of the liver significantly impacts the accuracy of delivered dose in radiotherapy. It limits margin reduction, dose escalation and normal tissue sparing. A critical component of motion management is to accurately reconstruct tumor motion. In this study, we developed a six degrees of freedom projection marker matching method (6-DoF PM3) to reconstruct translational and rotational liver tumor motion in a rotational treatment delivery, such as volumetric modulated arc therapy (VMAT). Specifically, we modeled the use of two gold markers implanted in a linear form. The four endpoints of the two gold linear markers were used as tracking surrogates. During delivery, kV x-ray projection images were acquired. A method was developed to automatically identify the 2D marker-endpoints on the projection images. 3D marker positions were determined by solving an optimization problem with the objective function penalizing the distance from the reconstructed 3D position of each fiducial marker endpoint to the corresponding straight line defined by the kV x-ray projection of the endpoints. We performed a series of tests to evaluate different components of the method. For 2D marker endpoints identification, 99.9% of the marker endpoints were identified with an error [Formula: see text] (1 pixel) along both u and v directions. For 3D reconstruction of motion in simulation studies, error of rotational angle was [Formula: see text]° without considering the 2D marker identification error. The rotational angle error was relatively sensitive to the accuracy of 2D marker identification. When the 2D error raised from 0.22 mm to 0.776 mm, the error of 3D rotational angle increased from 0.5° to 2.5°. In the experimental end-to-end tests, the mean root-mean square error of the 3D reconstructed marker positions was 0.75 mm and the mean error of rotational angle was within 1.7°. Our method can accurately determine intra-fractional liver tumor motion in rotational radiotherapy using kV projections of only two linear fiducial markers.

journal_name

Phys Med Biol

authors

Chi Y,Shen C,Li B,Zhang Y,Yang M,Folkert M,Jia X

doi

10.1088/1361-6560/ab4c0d

subject

Has Abstract

pub_date

2019-11-21 00:00:00

pages

225013

issue

22

eissn

0031-9155

issn

1361-6560

journal_volume

64

pub_type

杂志文章
  • A comprehensive study of the use of temporal moments in time-resolved diffuse optical tomography: part I. Theoretical material.

    abstract::The problem of fluorescence diffuse optical tomography consists in localizing fluorescent markers from near-infrared light measurements. Among the different available acquisition modalities, the time-resolved modality is expected to provide measurements of richer information content. To extract this information, the m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/23/004

    authors: Ducros N,Hervé L,Da Silva A,Dinten JM,Peyrin F

    更新日期:2009-12-07 00:00:00

  • Evaluation of multiple-sphere head models for MEG source localization.

    abstract::Magnetoencephalography (MEG) source analysis has largely relied on spherical conductor models of the head to simplify forward calculations of the brain's magnetic field. Multiple- (or overlapping, local) sphere models, where an optimal sphere is selected for each sensor, are considered an improvement over single-spher...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/010

    authors: Lalancette M,Quraan M,Cheyne D

    更新日期:2011-09-07 00:00:00

  • Study of the PTW microLion chamber temperature dependence.

    abstract::The use of liquid ionization chambers in radiotherapy has grown during the past few years. While for air ionization chambers the k(TP) correction for air mass density due to pressure and temperature variations is well known, less work has been done on the case of liquid ionization chambers, where there is still the ne...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2705

    authors: Gómez F,González-Castaño D,Díaz-Botana P,Pardo-Montero J

    更新日期:2014-06-07 00:00:00

  • Golden beam data for proton pencil-beam scanning.

    abstract::Proton, as well as other ion, beams applied by electro-magnetic deflection in pencil-beam scanning (PBS) are minimally perturbed and thus can be quantified a priori by their fundamental interactions in a medium. This a priori quantification permits an optimal reduction of characterizing measurements on a particular PB...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/5/1147

    authors: Clasie B,Depauw N,Fransen M,Gomà C,Panahandeh HR,Seco J,Flanz JB,Kooy HM

    更新日期:2012-03-07 00:00:00

  • Magnetic separation of iron oxide nanoparticles to improve their application for magnetic particle imaging.

    abstract::Magnetic Particle Imaging (MPI) is a promising medical imaging technique for visualizing the three-dimensional distribution of tracer materials, specifically iron oxide nanoparticles (IONP). The optimization of magnetic nanoparticles (MNP) plays an essential role to improve the image resolution and sensitivity of imag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abcd19

    authors: Arsalani S,Loewa N,Kosch O,Radon P,Baffa O,Wiekhorst F

    更新日期:2020-11-23 00:00:00

  • Prospects for in vivo Raman spectroscopy.

    abstract::Raman spectroscopy is a potentially important clinical tool for real-time diagnosis of disease and in situ evaluation of living tissue. The purpose of this article is to review the biological and physical basis of Raman spectroscopy of tissue, to assess the current status of the field and to explore future directions....

    journal_title:Physics in medicine and biology

    pub_type: 传,历史文章,杂志文章,评审

    doi:10.1088/0031-9155/45/2/201

    authors: Hanlon EB,Manoharan R,Koo TW,Shafer KE,Motz JT,Fitzmaurice M,Kramer JR,Itzkan I,Dasari RR,Feld MS

    更新日期:2000-02-01 00:00:00

  • Optimization of MAGIC gel formulation for three-dimensional radiation therapy dosimetry.

    abstract::Polymer gel dosimetry aims to provide three-dimensional images of radiation therapy dose distributions in irradiated aqueous gels. The first gels required manufacture in an oxygen-free environment, but later the MAGIC formulation was introduced, which could be made in normal atmospheric conditions. Here we report our ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/N03

    authors: Luci JJ,Whitney HM,Gore JC

    更新日期:2007-05-21 00:00:00

  • Dielectric studies on the reaction of the intracellular matter of fish red blood cells to detergent toxicity.

    abstract::Results from dielectric studies on the freshwater fish Cyprinus carpio exposed to a sublethal concentration of sodium alkyl benzene sulphonate were compared with those from untreated control fish; recovery from the test solution was also checked. The influence of the anionic detergent on the intracellular matter of fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/5/005

    authors: Bielinska I,Terlecki J

    更新日期:1984-05-01 00:00:00

  • Quantitative evaluation of myocardial function by a volume-normalized map generated from relative blood flow.

    abstract::Our study aimed to quantitatively evaluate blood flow in the left ventricle (LV) of apical hypertrophic cardiomyopathy (APH) by combining wall thickness obtained from cardiac magnetic resonance imaging (MRI) and myocardial perfusion from single-photon emission computed tomography (SPECT). In this study, we considered ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/14/019

    authors: Fukami T,Sato H,Wu J,Lwin TT,Yuasa T,Kawano S,Iida K,Akatsuka T,Hontani H,Takeda T,Tamura M,Yokota H

    更新日期:2007-07-21 00:00:00

  • High spatial resolution quantitative MR images: an experimental study of dedicated surface coils.

    abstract::Measuring spin-spin relaxation times (T2) by quantitative MR imaging represents a potentially efficient tool to evaluate the physicochemical properties of various media. However, noise in MR images is responsible for uncertainties in the determination of T2 relaxation times, which limits the accuracy of parametric tis...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/11/011

    authors: Gensanne D,Josse G,Lagarde JM,Vincensini D

    更新日期:2006-06-07 00:00:00

  • Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

    abstract::Developments in positron emission tomography (PET) technology have resulted in systems with finer detector elements designed to further improve spatial resolution. However, there is a limit to what extent reducing detector element size will improve spatial resolution in PET. The spatial resolution of PET imaging is li...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/3/019

    authors: Levin CS,Hoffman EJ

    更新日期:1999-03-01 00:00:00

  • Feasibility of salvage interstitial microwave thermal therapy for prostate carcinoma following failed brachytherapy: studies in a tissue equivalent phantom.

    abstract::Thermal therapy is an experimental treatment to destroy solid tumours by heating them to temperatures ranging from 55 degrees C to 90 degrees C, inducing thermal coagulation and necrosis of the tumour. We are investigating the feasibility of interstitial microwave thermal therapy as a salvage treatment for prostate ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/8/306

    authors: McCann C,Kumaradas JC,Gertner MR,Davidson SR,Dolan AM,Sherar MD

    更新日期:2003-04-21 00:00:00

  • Modeling late rectal toxicities based on a parameterized representation of the 3D dose distribution.

    abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/013

    authors: Buettner F,Gulliford SL,Webb S,Partridge M

    更新日期:2011-04-07 00:00:00

  • Carbon dioxide reactivity of computed tomography functional parameters in rabbit VX2 soft tissue tumour.

    abstract::Tumour blood flow is one of the important factors limiting the efficacy of radiation therapy (hypoxic radioresistance), chemotherapy (drug delivery) and thermal therapy (heat dissipation) in treating cancer. The modification of tumour blood flow has been an area of intense investigation. In the current study, the arte...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/7/303

    authors: Purdie TG,Lee TY

    更新日期:2003-04-07 00:00:00

  • Treatment time reduction for large thermal lesions by using a multiple 1D ultrasound phased array system.

    abstract::To generate large thermal lesions in ultrasound thermal therapy, cooling intermissions are usually introduced during the treatment to prevent near-field heating, which leads to a long treatment time. A possible strategy to shorten the total treatment time is to eliminate the cooling intermissions. In this study, the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/9/307

    authors: Liu HL,Chen YY,Yen JY,Lin WL

    更新日期:2003-05-07 00:00:00

  • Evaluation of nonuniform field exposures with coupling factors.

    abstract::In this study, the safety compliance for nonuniform field exposures is discussed using coupling factor concepts. The coupling factor, which is defined in the International Electrotechnical Commission 62311 standard, is extended to consider the effects of harmonics and also to apply to the specific absorption rate (for...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/20/8129

    authors: Sunohara T,Hirata A,Laakso I,De Santis V,Onishi T

    更新日期:2015-10-21 00:00:00

  • Monte Carlo generated mammograms: development and validation.

    abstract::We have developed a model using Monte Carlo methods to simulate x-ray mammography. All possible physical processes of interaction of x-rays with matter have been taken into account. A simplified geometry of the mammographic apparatus has been considered along with a software phantom of compressed breast. The phantom m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/11/012

    authors: Spyrou G,Tzanakos G,Bakas A,Panayiotakis G

    更新日期:1998-11-01 00:00:00

  • Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose.

    abstract::Although it is known that obesity has a profound effect on x-ray computed tomography (CT) image quality and patient organ dose, quantitative data describing this relationship are not currently available. This study examines the effect of obesity on the calculated radiation dose to organs and tissues from CT using newl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2441

    authors: Ding A,Mille MM,Liu T,Caracappa PF,Xu XG

    更新日期:2012-05-07 00:00:00

  • In-bore setup and software for 3T MRI-guided transperineal prostate biopsy.

    abstract::MRI-guided prostate biopsy in conventional closed-bore scanners requires transferring the patient outside the bore during needle insertion due to the constrained in-bore space, causing a safety hazard and limiting image feedback. To address this issue, we present our custom-made in-bore setup and software to support M...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/18/5823

    authors: Tokuda J,Tuncali K,Iordachita I,Song SE,Fedorov A,Oguro S,Lasso A,Fennessy FM,Tempany CM,Hata N

    更新日期:2012-09-21 00:00:00

  • Direct aperture optimization for a variable aperture collimator for intensity-modulated radiation therapy.

    abstract::In this note a technique is described for direct aperture optimization of components deliverable by a variable aperture collimator (VAC) for intensity-modulated radiation therapy. The first key result found was that, provided a large number of VAC components were selected for optimization, the resulting fluence profil...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/5/n02

    authors: Webb S

    更新日期:2004-03-07 00:00:00

  • Intermittent cryogen spray cooling for optimal heat extraction during dermatologic laser treatment.

    abstract::Fast heat extraction is critically important to obtain the maximal benefit of cryogen spray cooling (CSC) during laser therapy of shallow skin lesions, such as port wine stain birthmarks. However, a film of liquid cryogen can build up on the skin surface, impairing heat transfer due to the relatively low thermal condu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/18/301

    authors: Majaron B,Svaasand LO,Aguilar G,Nelson JS

    更新日期:2002-09-21 00:00:00

  • Ionization chamber volume determination and quality assurance using micro-CT imaging.

    abstract::Ion chamber dosimetry requires a high degree of precision, at all steps within the dosimetric process, in order to ensure accurate dose measurements. This work presents a novel technique for ion chamber volume determination and quality assurance, using micro-computed tomography (micro-CT). Four nominally identical Exr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/012

    authors: McNiven AL,Umoh J,Kron T,Holdsworth DW,Battista JJ

    更新日期:2008-09-21 00:00:00

  • The observation and analysis of cancer deaths among classified radiation workers.

    abstract::The extent to which occupational radiation exposure contributes to cancer mortality is an influence on future world energy policy. It is also a factor in deciding the level of expenditure to reduce radiation levels experienced by workers. Here we discuss some of the difficulties in analysing the situation and presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/6/001

    authors: Reissland JA,Kay P,Dolphin GW

    更新日期:1976-11-01 00:00:00

  • Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases.

    abstract::The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases originally calculated with pencil beam convolution (PBC) where large density inhomogeneit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/002

    authors: Hasenbalg F,Neuenschwander H,Mini R,Born EJ

    更新日期:2007-07-07 00:00:00

  • Optimal material discrimination using spectral x-ray imaging.

    abstract::Spectral x-ray imaging using novel photon counting x-ray detectors (PCDs) with energy resolving abilities is capable of providing energy-selective images. PCDs have energy thresholds, enabling the classification of photons into multiple energy bins. The extra energy information provided may allow materials such as iod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/18/012

    authors: Nik SJ,Meyer J,Watts R

    更新日期:2011-09-21 00:00:00

  • The inverse problem of a Gaussian convolution and its application to the finite size of the measurement chambers/detectors in photon and proton dosimetry.

    abstract::A Gaussian convolution kernel K is deduced as a Green's function of a Lie operator series. The deconvolution of a Gaussian kernel is developed by the inverse Green's function K(-1). A practical application is the deconvolution of measured profiles Dm(x) of photons and protons with finite detector size to determine the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/6/302

    authors: Ulmer W,Kaissl W

    更新日期:2003-03-21 00:00:00

  • Noise reduction and convergence of Bayesian algorithms with blobs based on the Huber function and median root prior.

    abstract::Iterative image reconstruction algorithms have the potential to produce low noise images. Early stopping of the iteration process is problematic because some features of the image may converge slowly. On the other hand, there may be noise build-up with increased number of iterations. Therefore, we examined the stabili...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/20/004

    authors: Chlewicki W,Hermansen F,Hansen SB

    更新日期:2004-10-21 00:00:00

  • Slice NEQ and system DQE to assess CT imaging performance.

    abstract::The standard Fourier metrics used for assessing image quality in computed tomography (CT) use a planar (2D) formulation of the noise equivalent quanta (NEQ) without a specific concept to manage the influence of longitudinal resolution variations, thus create a bias in the comparison of image quality for different reco...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab807a

    authors: Monnin P,Viry A,Verdun FR,Racine D

    更新日期:2020-06-09 00:00:00

  • Survey of numerical electrostimulation models.

    abstract::This paper evaluates results of a survey of electrostimulation models of myelinated nerve. Participants were asked to determine thresholds of excitation for 18 cases involving different characteristics of the neuron, the stimulation waveform, and the electrode arrangement. Responses were received from 7 investigators ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4346

    authors: Reilly JP

    更新日期:2016-06-21 00:00:00

  • A three-dimensional model-based partial volume correction strategy for gated cardiac mouse PET imaging.

    abstract::Quantification in cardiac mouse positron emission tomography (PET) imaging is limited by the imaging spatial resolution. Spillover of left ventricle (LV) myocardial activity into adjacent organs results in partial volume (PV) losses leading to underestimation of myocardial activity. A PV correction method was develope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4309

    authors: Dumouchel T,Thorn S,Kordos M,DaSilva J,Beanlands RS,deKemp RA

    更新日期:2012-07-07 00:00:00