Abstract:
:Multileaf collimator (MLC) calibration and quality control is a time-consuming procedure typically involving the processing, scanning and analysis of films to measure leaf and collimator positions. Faster and more reliable calibration procedures are required for these tasks, especially with the introduction of intensity modulated radiotherapy which requires more frequent checking and finer positional leaf tolerances than previously. A routine quality control (QC) technique to measure MLC leaf bank gain and offset, as well as minor offsets (individual leaf position relative to a reference leaf), using an amorphous silicon electronic portal imaging device (EPID) has been developed. The technique also tests the calibration of the primary and back-up collimators. A detailed comparison between film and EPID measurements has been performed for six linear accelerators (linacs) equipped with MLC and amorphous silicon EPIDs. Measurements of field size from 4 to 24 cm with the EPID were systematically smaller than film measurements over all field sizes by 0.4 mm for leaves/back-up collimators and by 0.2 mm for conventional collimators. This effect is due to the gain calibration correction applied by the EPID, resulting in a 'flattening' of primary beam profiles. Linac dependent systematic differences of up to 0.5 mm in individual leaf/collimator positions were also found between EPID and film measurements due to the difference between the mechanical and radiation axes of rotation. When corrections for these systematic differences were applied, the residual random differences between EPID and film were 0.23 mm and 0.26 mm (1 standard deviation) for field size and individual leaf/back-up collimator position, respectively. Measured gains (over a distance of 220 mm) always agreed within 0.4 mm with a standard deviation of 0.17 mm. Minor offset measurements gave a mean agreement between EPID and film of 0.01+/-0.10 mm (1 standard deviation) after correction for the tilt of the EPID and small rotational misalignments between leaf banks and the back-up collimators used as a reference straight edge. Reproducibility of EPID measurements was found to be very high, with a standard deviation of <0.05 mm for field size and <0.1 mm for individual leaf/collimator positions for a 10x10 cm2 field. A standard set of QC images (three field sizes defined both by leaves only and collimators only) can be acquired in less than 20 min and analysed in 5 min.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Baker SJ,Budgell GJ,MacKay RIdoi
10.1088/0031-9155/50/7/003subject
Has Abstractpub_date
2005-04-07 00:00:00pages
1377-92issue
7eissn
0031-9155issn
1361-6560pii
S0031-9155(05)88214-4journal_volume
50pub_type
杂志文章abstract::There is a need to verify the accuracy of general purpose Monte Carlo codes like EGSnrc, which are commonly employed for investigations of dosimetric problems in radiation therapy. A number of experimental benchmarks have been published to compare calculated values of absorbed dose to experimentally determined values....
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/19/7637
更新日期:2015-10-07 00:00:00
abstract::An ESTRO booklet and a report of the Netherlands Commission on Radiation Dosimetry have been published recently describing empirical methods for monitor unit (MU) calculations in symmetrical high-energy photon beams. Both documents support the same basic ideas; firstly the separation of head scatter and volume scatter...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/12/310
更新日期:1999-12-01 00:00:00
abstract::MRI-guided prostate biopsy in conventional closed-bore scanners requires transferring the patient outside the bore during needle insertion due to the constrained in-bore space, causing a safety hazard and limiting image feedback. To address this issue, we present our custom-made in-bore setup and software to support M...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/18/5823
更新日期:2012-09-21 00:00:00
abstract::Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa58c9
更新日期:2017-03-07 00:00:00
abstract::We present the results of utilizing aligned anatomical information from CT images to locally adjust image smoothness during the reconstruction of three-dimensional (3D) whole-body positron emission tomography (PET) data. The ability of whole-body PET imaging to detect malignant neoplasms is becoming widely recognized....
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/1/301
更新日期:2002-01-07 00:00:00
abstract::In medical imaging different techniques have been developed to gain information from inside a tissue. Optoacoustics is a method to generate tomography pictures of tissue using Q-switched laser pulses. Due to thermal and pressure confinement, a short light pulse generates a pressure distribution inside tissue, which mi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/7/309
更新日期:2001-07-01 00:00:00
abstract::The purpose of this study is to evaluate a new method to improve performance of computer-aided detection (CAD) schemes of screening mammograms with two approaches. In the first approach, we developed a new case based CAD scheme using a set of optimally selected global mammographic density, texture, spiculation, and st...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5081
更新日期:2017-01-21 00:00:00
abstract::We propose a novel scintillation detector design for positron emission tomography (PET), which has depth of interaction (DOI) capability and uses a single-ended readout scheme. The DOI detector contains a pair of crystal bars segmented using sub-surface laser engraving (SSLE). The two crystal bars are optically couple...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/18/6635
更新日期:2016-09-21 00:00:00
abstract::Most tissue characterization methods use RF data originating from backscattering processes in the insonified tissue. Characterization of the tissue of a thin layer (e.g., an artery wall) poses problems because of the small amount of data available. The tissue layer may be so thin that there are no RF data that are not...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/36/10/002
更新日期:1991-10-01 00:00:00
abstract::To achieve accurate and fast deformable image registration (DIR) for pulmonary CT, we proposed a Multi-scale DIR framework with unsupervised Joint training of Convolutional Neural Network (MJ-CNN). MJ-CNN contains three models at multi-scale levels for a coarse-to-fine DIR to avoid being trapped in a local minimum. It...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab5da0
更新日期:2020-01-13 00:00:00
abstract::A parametric model for the x-ray linear attenuation coefficient is used to describe the compositional dependence of Hounsfield numbers measured by medical CT scanners. Measurements with materials of known density and composition, that span and evenly sample the compositional range of tissues, are written as linear sim...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/23/7479
更新日期:2014-12-07 00:00:00
abstract::Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this 'tissue fraction effect' (TFE). In this paper, we extend ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/18/7387
更新日期:2015-09-21 00:00:00
abstract::ICRP Publication 116 on 'Conversion coefficients for radiological protection quantities for external radiation exposures', provides fluence-to-dose conversion coefficients for organ-absorbed doses and effective dose for various types of external exposures (ICRP 2010 ICRP Publication 116). The publication supersedes th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/18/5209
更新日期:2014-09-21 00:00:00
abstract::For quantitative measurements of small animals such as mice or rats, a compact and high sensitivity continuous blood sampling detector is required because their blood sampling volume is limited. For this purpose we have developed and tested a new positron detector. The positron detector uses a pair of dual-layer thin ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/13/016
更新日期:2010-07-07 00:00:00
abstract::Diffusion weighted magnetic resonance imaging offers a non-invasive tool to explore the three-dimensional structure of brain white matter in clinical practice. Anisotropic diffusion hardware phantoms are useful for the quantitative validation of this technique. This study provides guidelines on how to manufacture anis...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/19/009
更新日期:2008-10-07 00:00:00
abstract::The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were impl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/1/007
更新日期:2007-01-07 00:00:00
abstract::109Cd K x-ray fluorescence (XRF) measurement systems from two research centres were used to measure tibia lead content in a population (n = 530) of young adults. The group mean bone lead contents (+/-SEM) determined by McMaster University (n = 214) and the University of Maryland (n = 316) were 2.80 +/- 0.51 and 2.33 +...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/9/313
更新日期:1999-09-01 00:00:00
abstract::Previous treatment of cerebrospinal fluid (CSF) malignancies by intrathecal administration of (131)I-radiolabelled monoclonal antibodies has led to the assumption that more healthy tissue will be spared when a pure beta-emitter such as (90)Y replaces (131)I. The purpose of this study is to compare and quantitatively e...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/1/014
更新日期:2006-01-07 00:00:00
abstract::The reference levels for testing compliance of human exposure with radio-frequency (RF) safety limits have been derived from very simplified models of the human. In order to validate these findings for anatomical models, we investigated the absorption characteristics for various anatomies ranging from 6 year old child...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/4/004
更新日期:2009-02-21 00:00:00
abstract::Recently, deep learning technology has achieved various successes in medical image analysis studies including computer-aided diagnosis (CADx). However, current CADx approaches based on deep learning have a limitation in interpreting diagnostic decisions. The limited interpretability is a major challenge for practical ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaef0a
更新日期:2018-12-04 00:00:00
abstract::The local noise property of a 3D PET reconstructed image is investigated for a uniform-activity sphere distributed in a constantly attenuating spherical object. The positional dependence of the statistical noise is approximately derived and calculated for some special cases. It is suggested that a larger diameter of t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/42/1/015
更新日期:1997-01-01 00:00:00
abstract::The in-phantom calibration method for radiotherapy kilovoltage x-ray beams requires ionization chamber correction factors. The overall ionization chamber correction factor accounts for changes in the chamber response due to the displacement of water by the chamber cavity and wall, the presence of the stem and the chan...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab82e7
更新日期:2020-05-11 00:00:00
abstract::Most commonly in radiation therapy, treatments are delivered in a co-planar geometry. Numerous advantages have been reported of adding non-coplanar beams to the treatment plan. The aim of this study was to compare current state-of-the-art VMAT and CyberKnife treatment plans to that of a novel linac design developed at...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab246f
更新日期:2019-06-20 00:00:00
abstract::Plutonium-239 and americium-241 were administered to adult hamsters in various chemical forms and their absorption from the gut was measured. The results have been compared with published data on other species in order to derive values for the estimated absorption of these actinides in man. On the basis of current kno...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/24/2/015
更新日期:1979-03-01 00:00:00
abstract::Radiochromic films are useful as dosimeters in high-precision radiotherapy owing to their high spatial resolution. However, when a particle beam is measured using a radiochromic film, the dose cannot be estimated accurately because the film darkness varies with variations in linear energy transfer (LET). This paper pr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab8bf3
更新日期:2020-06-15 00:00:00
abstract::Although field area and object thickness are important parameters in comparisons of techniques for optimal reduction of scattered radiation to the image, they are in practice seldom varied. For this reason, we suggest that contrast degradation (CDF) and contrast improvement (CIF) factors be more frequently used and ap...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/31/7/004
更新日期:1986-07-01 00:00:00
abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab0d50
更新日期:2019-05-02 00:00:00
abstract::Numerous studies of early-stage breast cancer treated with breast conserving surgery (BCS) and radiotherapy (RT) have been published in recent years. Both external beam radiotherapy (EBRT) and/or brachytherapy (BT) with different fractionation schemes are currently used. The present RT practice is largely based on emp...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,meta分析
doi:10.1088/0031-9155/48/20/004
更新日期:2003-10-21 00:00:00
abstract::Managing uncertainty is a major challenge in radiation therapy treatment planning, including uncertainty induced by intrafraction motion, which is particularly important for tumours in the thorax and abdomen. Common methods to account for motion are to introduce a margin or to convolve the static dose distribution wit...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/10/014
更新日期:2006-05-21 00:00:00
abstract::Reducing radiation dose in dual energy computed tomography (DECT) is highly desirable but it may lead to excessive noise in the filtered backprojection (FBP) reconstructed DECT images, which can inevitably increase the diagnostic uncertainty. To obtain clinically acceptable DECT images from low-mAs acquisitions, in th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa7122
更新日期:2017-07-07 00:00:00