Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.

Abstract:

:Multileaf collimator (MLC) calibration and quality control is a time-consuming procedure typically involving the processing, scanning and analysis of films to measure leaf and collimator positions. Faster and more reliable calibration procedures are required for these tasks, especially with the introduction of intensity modulated radiotherapy which requires more frequent checking and finer positional leaf tolerances than previously. A routine quality control (QC) technique to measure MLC leaf bank gain and offset, as well as minor offsets (individual leaf position relative to a reference leaf), using an amorphous silicon electronic portal imaging device (EPID) has been developed. The technique also tests the calibration of the primary and back-up collimators. A detailed comparison between film and EPID measurements has been performed for six linear accelerators (linacs) equipped with MLC and amorphous silicon EPIDs. Measurements of field size from 4 to 24 cm with the EPID were systematically smaller than film measurements over all field sizes by 0.4 mm for leaves/back-up collimators and by 0.2 mm for conventional collimators. This effect is due to the gain calibration correction applied by the EPID, resulting in a 'flattening' of primary beam profiles. Linac dependent systematic differences of up to 0.5 mm in individual leaf/collimator positions were also found between EPID and film measurements due to the difference between the mechanical and radiation axes of rotation. When corrections for these systematic differences were applied, the residual random differences between EPID and film were 0.23 mm and 0.26 mm (1 standard deviation) for field size and individual leaf/back-up collimator position, respectively. Measured gains (over a distance of 220 mm) always agreed within 0.4 mm with a standard deviation of 0.17 mm. Minor offset measurements gave a mean agreement between EPID and film of 0.01+/-0.10 mm (1 standard deviation) after correction for the tilt of the EPID and small rotational misalignments between leaf banks and the back-up collimators used as a reference straight edge. Reproducibility of EPID measurements was found to be very high, with a standard deviation of <0.05 mm for field size and <0.1 mm for individual leaf/collimator positions for a 10x10 cm2 field. A standard set of QC images (three field sizes defined both by leaves only and collimators only) can be acquired in less than 20 min and analysed in 5 min.

journal_name

Phys Med Biol

authors

Baker SJ,Budgell GJ,MacKay RI

doi

10.1088/0031-9155/50/7/003

subject

Has Abstract

pub_date

2005-04-07 00:00:00

pages

1377-92

issue

7

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(05)88214-4

journal_volume

50

pub_type

杂志文章
  • Uncertainties in Monte Carlo-based absorbed dose calculations for an experimental benchmark.

    abstract::There is a need to verify the accuracy of general purpose Monte Carlo codes like EGSnrc, which are commonly employed for investigations of dosimetric problems in radiation therapy. A number of experimental benchmarks have been published to compare calculated values of absorbed dose to experimentally determined values....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/19/7637

    authors: Renner F,Wulff J,Kapsch RP,Zink K

    更新日期:2015-10-07 00:00:00

  • Monitor unit calculation on the beam axis of open and wedged asymmetric high-energy photon beams.

    abstract::An ESTRO booklet and a report of the Netherlands Commission on Radiation Dosimetry have been published recently describing empirical methods for monitor unit (MU) calculations in symmetrical high-energy photon beams. Both documents support the same basic ideas; firstly the separation of head scatter and volume scatter...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/12/310

    authors: Georg D

    更新日期:1999-12-01 00:00:00

  • In-bore setup and software for 3T MRI-guided transperineal prostate biopsy.

    abstract::MRI-guided prostate biopsy in conventional closed-bore scanners requires transferring the patient outside the bore during needle insertion due to the constrained in-bore space, causing a safety hazard and limiting image feedback. To address this issue, we present our custom-made in-bore setup and software to support M...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/18/5823

    authors: Tokuda J,Tuncali K,Iordachita I,Song SE,Fedorov A,Oguro S,Lasso A,Fennessy FM,Tempany CM,Hata N

    更新日期:2012-09-21 00:00:00

  • Building an open-source simulation platform of acoustic radiation force-based breast elastography.

    abstract::Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa58c9

    authors: Wang Y,Peng B,Jiang J

    更新日期:2017-03-07 00:00:00

  • Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.

    abstract::We present the results of utilizing aligned anatomical information from CT images to locally adjust image smoothness during the reconstruction of three-dimensional (3D) whole-body positron emission tomography (PET) data. The ability of whole-body PET imaging to detect malignant neoplasms is becoming widely recognized....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/1/301

    authors: Comtat C,Kinahan PE,Fessler JA,Beyer T,Townsend DW,Defrise M,Michel C

    更新日期:2002-01-07 00:00:00

  • Temporal backward projection of optoacoustic pressure transients using fourier transform methods.

    abstract::In medical imaging different techniques have been developed to gain information from inside a tissue. Optoacoustics is a method to generate tomography pictures of tissue using Q-switched laser pulses. Due to thermal and pressure confinement, a short light pulse generates a pressure distribution inside tissue, which mi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/7/309

    authors: Köstli KP,Frenz M,Bebie H,Weber HP

    更新日期:2001-07-01 00:00:00

  • Developing a new case based computer-aided detection scheme and an adaptive cueing method to improve performance in detecting mammographic lesions.

    abstract::The purpose of this study is to evaluate a new method to improve performance of computer-aided detection (CAD) schemes of screening mammograms with two approaches. In the first approach, we developed a new case based CAD scheme using a set of optimally selected global mammographic density, texture, spiculation, and st...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5081

    authors: Tan M,Aghaei F,Wang Y,Zheng B

    更新日期:2017-01-21 00:00:00

  • A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving.

    abstract::We propose a novel scintillation detector design for positron emission tomography (PET), which has depth of interaction (DOI) capability and uses a single-ended readout scheme. The DOI detector contains a pair of crystal bars segmented using sub-surface laser engraving (SSLE). The two crystal bars are optically couple...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6635

    authors: Uchida H,Sakai T,Yamauchi H,Hakamata K,Shimizu K,Yamashita T

    更新日期:2016-09-21 00:00:00

  • The use of narrowband ultrasound for characterization of tissue in a thin layer.

    abstract::Most tissue characterization methods use RF data originating from backscattering processes in the insonified tissue. Characterization of the tissue of a thin layer (e.g., an artery wall) poses problems because of the small amount of data available. The tissue layer may be so thin that there are no RF data that are not...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/10/002

    authors: Linssen FM,Hoeks AP,Brands PJ

    更新日期:1991-10-01 00:00:00

  • A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration.

    abstract::To achieve accurate and fast deformable image registration (DIR) for pulmonary CT, we proposed a Multi-scale DIR framework with unsupervised Joint training of Convolutional Neural Network (MJ-CNN). MJ-CNN contains three models at multi-scale levels for a coarse-to-fine DIR to avoid being trapped in a local minimum. It...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5da0

    authors: Jiang Z,Yin FF,Ge Y,Ren L

    更新日期:2020-01-13 00:00:00

  • A method for estimating radiation interaction coefficients for tissues from single energy CT.

    abstract::A parametric model for the x-ray linear attenuation coefficient is used to describe the compositional dependence of Hounsfield numbers measured by medical CT scanners. Measurements with materials of known density and composition, that span and evenly sample the compositional range of tissues, are written as linear sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/23/7479

    authors: Midgley SM

    更新日期:2014-12-07 00:00:00

  • Improved correction for the tissue fraction effect in lung PET/CT imaging.

    abstract::Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this 'tissue fraction effect' (TFE). In this paper, we extend ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7387

    authors: Holman BF,Cuplov V,Millner L,Hutton BF,Maher TM,Groves AM,Thielemans K

    更新日期:2015-09-21 00:00:00

  • ICRP Publication 116--the first ICRP/ICRU application of the male and female adult reference computational phantoms.

    abstract::ICRP Publication 116 on 'Conversion coefficients for radiological protection quantities for external radiation exposures', provides fluence-to-dose conversion coefficients for organ-absorbed doses and effective dose for various types of external exposures (ICRP 2010 ICRP Publication 116). The publication supersedes th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/18/5209

    authors: Petoussi-Henss N,Bolch WE,Eckerman KF,Endo A,Hertel N,Hunt J,Menzel HG,Pelliccioni M,Schlattl H,Zankl M

    更新日期:2014-09-21 00:00:00

  • A compact and high sensitivity positron detector using dual-layer thin GSO scintillators for a small animal PET blood sampling system.

    abstract::For quantitative measurements of small animals such as mice or rats, a compact and high sensitivity continuous blood sampling detector is required because their blood sampling volume is limited. For this purpose we have developed and tested a new positron detector. The positron detector uses a pair of dual-layer thin ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/13/016

    authors: Yamamoto S,Imaizumi M,Shimosegawa E,Kanai Y,Sakamoto Y,Minato K,Shimizu K,Senda M,Hatazawa J

    更新日期:2010-07-07 00:00:00

  • The design of anisotropic diffusion phantoms for the validation of diffusion weighted magnetic resonance imaging.

    abstract::Diffusion weighted magnetic resonance imaging offers a non-invasive tool to explore the three-dimensional structure of brain white matter in clinical practice. Anisotropic diffusion hardware phantoms are useful for the quantitative validation of this technique. This study provides guidelines on how to manufacture anis...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/19/009

    authors: Fieremans E,De Deene Y,Delputte S,Ozdemir MS,Achten E,Lemahieu I

    更新日期:2008-10-07 00:00:00

  • 3D thoracoscopic ultrasound volume measurement validation in an ex vivo and in vivo porcine model of lung tumours.

    abstract::The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were impl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/1/007

    authors: Hornblower VD,Yu E,Fenster A,Battista JJ,Malthaner RA

    更新日期:2007-01-07 00:00:00

  • Factors affecting in vivo measurement precision and accuracy of 109Cd K x-ray fluorescence measurements.

    abstract::109Cd K x-ray fluorescence (XRF) measurement systems from two research centres were used to measure tibia lead content in a population (n = 530) of young adults. The group mean bone lead contents (+/-SEM) determined by McMaster University (n = 214) and the University of Maryland (n = 316) were 2.80 +/- 0.51 and 2.33 +...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/9/313

    authors: McNeill FE,Stokes L,Chettle DR,Kaye WE

    更新日期:1999-09-01 00:00:00

  • Dose distribution to spinal structures from intrathecally administered yttrium-90.

    abstract::Previous treatment of cerebrospinal fluid (CSF) malignancies by intrathecal administration of (131)I-radiolabelled monoclonal antibodies has led to the assumption that more healthy tissue will be spared when a pure beta-emitter such as (90)Y replaces (131)I. The purpose of this study is to compare and quantitatively e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/1/014

    authors: Mardirossian G,Hall M,Montebello J,Stevens P

    更新日期:2006-01-07 00:00:00

  • Assessment of induced radio-frequency electromagnetic fields in various anatomical human body models.

    abstract::The reference levels for testing compliance of human exposure with radio-frequency (RF) safety limits have been derived from very simplified models of the human. In order to validate these findings for anatomical models, we investigated the absorption characteristics for various anatomies ranging from 6 year old child...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/004

    authors: Kühn S,Jennings W,Christ A,Kuster N

    更新日期:2009-02-21 00:00:00

  • Visually interpretable deep network for diagnosis of breast masses on mammograms.

    abstract::Recently, deep learning technology has achieved various successes in medical image analysis studies including computer-aided diagnosis (CADx). However, current CADx approaches based on deep learning have a limitation in interpreting diagnostic decisions. The limited interpretability is a major challenge for practical ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaef0a

    authors: Kim ST,Lee JH,Lee H,Ro YM

    更新日期:2018-12-04 00:00:00

  • The local noise property in positron volume imaging and optimal conditions for the signal-to-noise ratio of the 3D reconstructed image.

    abstract::The local noise property of a 3D PET reconstructed image is investigated for a uniform-activity sphere distributed in a constantly attenuating spherical object. The positional dependence of the statistical noise is approximately derived and calculated for some special cases. It is suggested that a larger diameter of t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/1/015

    authors: Murayama H,Nohara N

    更新日期:1997-01-01 00:00:00

  • Monte Carlo and water calorimetric determination of kilovoltage beam radiotherapy ionization chamber correction factors.

    abstract::The in-phantom calibration method for radiotherapy kilovoltage x-ray beams requires ionization chamber correction factors. The overall ionization chamber correction factor accounts for changes in the chamber response due to the displacement of water by the chamber cavity and wall, the presence of the stem and the chan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab82e7

    authors: Bancheri J,Ketelhut S,Büermann L,Seuntjens J

    更新日期:2020-05-11 00:00:00

  • Conical beam geometry intensity-modulated radiation therapy.

    abstract::Most commonly in radiation therapy, treatments are delivered in a co-planar geometry. Numerous advantages have been reported of adding non-coplanar beams to the treatment plan. The aim of this study was to compare current state-of-the-art VMAT and CyberKnife treatment plans to that of a novel linac design developed at...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab246f

    authors: Schüler E,Wang L,Loo BW,Maxim PG

    更新日期:2019-06-20 00:00:00

  • The gastrointestinal absorption of plutonium and americium in the hamster.

    abstract::Plutonium-239 and americium-241 were administered to adult hamsters in various chemical forms and their absorption from the gut was measured. The results have been compared with published data on other species in order to derive values for the estimated absorption of these actinides in man. On the basis of current kno...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/015

    authors: Stather JW,Harrison JD,Rodwell P,David AJ

    更新日期:1979-03-01 00:00:00

  • Simultaneous determination of the dose and linear energy transfer (LET) of carbon-ion beams using radiochromic films.

    abstract::Radiochromic films are useful as dosimeters in high-precision radiotherapy owing to their high spatial resolution. However, when a particle beam is measured using a radiochromic film, the dose cannot be estimated accurately because the film darkness varies with variations in linear energy transfer (LET). This paper pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8bf3

    authors: Kawashima M,Matsumura A,Souda H,Tashiro M

    更新日期:2020-06-15 00:00:00

  • Generalised use of contrast degradation and contrast improvement factors in diagnostic radiology. Application to vanishing contrast.

    abstract::Although field area and object thickness are important parameters in comparisons of techniques for optimal reduction of scattered radiation to the image, they are in practice seldom varied. For this reason, we suggest that contrast degradation (CDF) and contrast improvement (CIF) factors be more frequently used and ap...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/7/004

    authors: Carlsson GA,Carlsson CA,Nielsen B,Persliden J

    更新日期:1986-07-01 00:00:00

  • 4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

    abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0d50

    authors: Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

    更新日期:2019-05-02 00:00:00

  • Analysis of a large number of clinical studies for breast cancer radiotherapy: estimation of radiobiological parameters for treatment planning.

    abstract::Numerous studies of early-stage breast cancer treated with breast conserving surgery (BCS) and radiotherapy (RT) have been published in recent years. Both external beam radiotherapy (EBRT) and/or brachytherapy (BT) with different fractionation schemes are currently used. The present RT practice is largely based on emp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,meta分析

    doi:10.1088/0031-9155/48/20/004

    authors: Guerrero M,Li XA

    更新日期:2003-10-21 00:00:00

  • A robust approach to IMRT optimization.

    abstract::Managing uncertainty is a major challenge in radiation therapy treatment planning, including uncertainty induced by intrafraction motion, which is particularly important for tumours in the thorax and abdomen. Common methods to account for motion are to introduce a margin or to convolve the static dose distribution wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/014

    authors: Chan TC,Bortfeld T,Tsitsiklis JN

    更新日期:2006-05-21 00:00:00

  • Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization.

    abstract::Reducing radiation dose in dual energy computed tomography (DECT) is highly desirable but it may lead to excessive noise in the filtered backprojection (FBP) reconstructed DECT images, which can inevitably increase the diagnostic uncertainty. To obtain clinically acceptable DECT images from low-mAs acquisitions, in th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7122

    authors: Zhang H,Zeng D,Lin J,Zhang H,Bian Z,Huang J,Gao Y,Zhang S,Zhang H,Feng Q,Liang Z,Chen W,Ma J

    更新日期:2017-07-07 00:00:00