Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization.

Abstract:

:Reducing radiation dose in dual energy computed tomography (DECT) is highly desirable but it may lead to excessive noise in the filtered backprojection (FBP) reconstructed DECT images, which can inevitably increase the diagnostic uncertainty. To obtain clinically acceptable DECT images from low-mAs acquisitions, in this work we develop a novel scheme based on measurement of DECT data. In this scheme, inspired by the success of edge-preserving non-local means (NLM) filtering in CT imaging and the intrinsic characteristics underlying DECT images, i.e. global correlation and non-local similarity, an averaged image induced NLM-based (aviNLM) regularization is incorporated into the penalized weighted least-squares (PWLS) framework. Specifically, the presented NLM-based regularization is designed by averaging the acquired DECT images, which takes the image similarity within the two energies into consideration. In addition, the weighted least-squares term takes into account DECT data-dependent variance. For simplicity, the presented scheme was termed as 'PWLS-aviNLM'. The performance of the presented PWLS-aviNLM algorithm was validated and evaluated on digital phantom, physical phantom and patient data. The extensive experiments validated that the presented PWLS-aviNLM algorithm outperforms the FBP, PWLS-TV and PWLS-NLM algorithms quantitatively. More importantly, it delivers the best qualitative results with the finest details and the fewest noise-induced artifacts, due to the aviNLM regularization learned from DECT images. This study demonstrated the feasibility and efficacy of the presented PWLS-aviNLM algorithm to improve the DECT reconstruction and resulting material decomposition.

journal_name

Phys Med Biol

authors

Zhang H,Zeng D,Lin J,Zhang H,Bian Z,Huang J,Gao Y,Zhang S,Zhang H,Feng Q,Liang Z,Chen W,Ma J

doi

10.1088/1361-6560/aa7122

subject

Has Abstract

pub_date

2017-07-07 00:00:00

pages

5556-5574

issue

13

eissn

0031-9155

issn

1361-6560

journal_volume

62

pub_type

杂志文章
  • Three-dimensional performance of a small-diameter positron emission tomograph.

    abstract::Recently, the initial 2D physical characterization of a small-diameter positron emission tomograph, designed specifically for scanning of small laboratory animals, was reported. The physical characteristics of the tomograph operating in 3D mode have now been measured and compared to those obtained in 2D mode. In 3D, t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/2/010

    authors: Bloomfield PM,Myers R,Hume SP,Spinks TJ,Lammertsma AA,Jones T

    更新日期:1997-02-01 00:00:00

  • W values and other transport data on low energy electrons in tissue equivalent gas.

    abstract::The degradation of low energy electrons in a methane based, tissue equivalent gas was studied experimentally by ionization chamber experiments and theoretically by Monte Carlo electron transport simulation in the energy range between 25 eV and 5 keV. From measured ionization yields and calculated ionization and energy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/5/008

    authors: Waibel E,Grosswendt B

    更新日期:1992-05-01 00:00:00

  • Convex reformulation of biologically-based multi-criteria intensity-modulated radiation therapy optimization including fractionation effects.

    abstract::Finding fluence maps for intensity-modulated radiation therapy (IMRT) can be formulated as a multi-criteria optimization problem for which Pareto optimal treatment plans exist. To account for the dose-per-fraction effect of fractionated IMRT, it is desirable to exploit radiobiological treatment plan evaluation criteri...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/006

    authors: Hoffmann AL,den Hertog D,Siem AY,Kaanders JH,Huizenga H

    更新日期:2008-11-21 00:00:00

  • Online compensation for target motion with scanned particle beams: simulation environment.

    abstract::Target motion is one of the major limitations of each high precision radiation therapy. Using advanced active beam delivery techniques, such as the magnetic raster scanning system for particle irradiation, the interplay between time-dependent beam and target position heavily distorts the applied dose distribution. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/14/001

    authors: Li Q,Groezinger SO,Haberer T,Rietzel E,Kraft G

    更新日期:2004-07-21 00:00:00

  • Towards abdominal MRI-based treatment planning using population-based Hounsfield units for bulk density assignment.

    abstract::This study investigates the dosimetric impact of using population-based Hounsfield units (HUs) and ICRU-based HUs as a function of the number of tissue segments for bulk density assignment toward MRI-based treatment planning in the abdomen. To avoid potential geometric differences between CT and MR images, CT images r...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aacfb1

    authors: Hsu SH,Zawisza I,O'Grady K,Peng Q,Tomé WA

    更新日期:2018-07-24 00:00:00

  • Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound.

    abstract::This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/11/011

    authors: Chen L,ter Haar G,Hill CR,Dworkin M,Carnochan P,Young H,Bensted JP

    更新日期:1993-11-01 00:00:00

  • Transport-based quantitative photoacoustic tomography: simulations and experiments.

    abstract::In this paper we describe a method for quantitative photoacoustic tomography (qPAT) based on the photon radiative transfer equation (RTE) coupled with the Helmholtz photoacoustic wave equation. Considerable simulations and tissue-like phantom experiments are conducted to evaluate transport-based qPAT in comparison wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/7/009

    authors: Yao L,Sun Y,Jiang H

    更新日期:2010-04-07 00:00:00

  • PETSIM: Monte Carlo simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems.

    abstract::Monte Carlo simulation techniques are applied to track the annihilation photons from positron decay, and store the photon histories. Reasonably realistic models of the isotope distribution in the brain and heart during typical PET studies, as well as the traditional phantoms used for measuring PET scanner performance ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/3/017

    authors: Thompson CJ,Moreno-Cantu J,Picard Y

    更新日期:1992-03-01 00:00:00

  • Scatter dose for wedged fields.

    abstract::The behaviour of scatter dose in 4 and 8 MV wedged x-ray beams has been studied by calculating scatter-to-primary dose ratios (SPR) and comparing these with SPR for non-wedged beams. On the central axis the SPR for wedged and non-wedged beams differ only by a few per cent, a difference which increases slightly with we...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/10/010

    authors: Brown LH,Siddon RL,Bjärngard BE

    更新日期:1987-10-01 00:00:00

  • Aperture modulated arc therapy.

    abstract::We show that it is possible to translate an intensity modulated radiation therapy (IMRT) treatment plan and deliver it as a single arc. This technique is referred to in this paper as aperture modulation arc therapy (AMAT). During this arc, the MLC leaves do not conform to the projection of the target PTV and the machi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/10/307

    authors: Crooks SM,Wu X,Takita C,Watzich M,Xing L

    更新日期:2003-05-21 00:00:00

  • Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering.

    abstract::This paper addresses fundamental issues that underlie the interpretation of images acquired from turbid tissues by optical-coherence tomography (OCT). The attenuation and backscattering properties of freshly excised rat arteries and their dependence on the focusing and collection optics of the OCT system were measured...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/10/013

    authors: Schmitt JM,Knüttel A,Yadlowsky M,Eckhaus MA

    更新日期:1994-10-01 00:00:00

  • A potential method for in vivo range verification in proton therapy treatment.

    abstract::Proton therapy potentially offers excellent dose conformality and reduction in integral dose. The superior dose distribution is, however, much more sensitive to the radiological depth along the beam path than for photon fields. Variations in this depth due to inaccurate planning calculation, setup uncertainty, respira...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/5/016

    authors: Lu HM

    更新日期:2008-03-07 00:00:00

  • The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact.

    abstract::The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling;...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9a2f

    authors: Simon JC,Sapozhnikov OA,Kreider W,Breshock M,Williams JC,Bailey MR

    更新日期:2018-01-09 00:00:00

  • Comparison study of temporal regularization methods for fully 5D reconstruction of cardiac gated dynamic SPECT.

    abstract::Temporal regularization plays a critical role in cardiac gated dynamic SPECT reconstruction, of which the goal is to obtain an image sequence from a single acquisition which simultaneously shows both cardiac motion and tracer distribution change over the course of imaging (termed 5D). In our recent work, we explored t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5523

    authors: Niu X,Yang Y,King MA

    更新日期:2012-09-07 00:00:00

  • Direct aperture optimization for a variable aperture collimator for intensity-modulated radiation therapy.

    abstract::In this note a technique is described for direct aperture optimization of components deliverable by a variable aperture collimator (VAC) for intensity-modulated radiation therapy. The first key result found was that, provided a large number of VAC components were selected for optimization, the resulting fluence profil...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/5/n02

    authors: Webb S

    更新日期:2004-03-07 00:00:00

  • Electromagnetic redesign of the HYPERcollar applicator: toward improved deep local head-and-neck hyperthermia.

    abstract::Accumulating evidence shows that hyperthermia improves head-and-neck cancer treatment. Over the last decade, we introduced a radiofrequency applicator, named HYPERcollar, which enables local heating also of deep locations in this region. Based on clinical experience, we redesigned the HYPERcollar for improved comfort,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5997

    authors: Togni P,Rijnen Z,Numan WC,Verhaart RF,Bakker JF,van Rhoon GC,Paulides MM

    更新日期:2013-09-07 00:00:00

  • A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

    abstract::Quantitative Yttrium-90 ((90)Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of (90)Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3711

    authors: Rong X,Du Y,Frey EC

    更新日期:2012-06-21 00:00:00

  • Uncertainties in Monte Carlo-based absorbed dose calculations for an experimental benchmark.

    abstract::There is a need to verify the accuracy of general purpose Monte Carlo codes like EGSnrc, which are commonly employed for investigations of dosimetric problems in radiation therapy. A number of experimental benchmarks have been published to compare calculated values of absorbed dose to experimentally determined values....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/19/7637

    authors: Renner F,Wulff J,Kapsch RP,Zink K

    更新日期:2015-10-07 00:00:00

  • Implementation of biologically conformal radiation therapy (BCRT) in an algorithmic segmentation-based inverse planning approach.

    abstract::The development of new biological imaging technologies offers the opportunity to further individualize radiotherapy. Biologically conformal radiation therapy (BCRT) implies the use of the spatial distribution of one or more radiobiological parameters to guide the IMRT dose prescription. Our aim was to implement BCRT i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/16/N02

    authors: Vanderstraeten B,De Gersem W,Duthoy W,De Neve W,Thierens H

    更新日期:2006-08-21 00:00:00

  • Hidden Markov modelling of spike propagation from interictal MEG data.

    abstract::For patients with partial epilepsy, automatic spike detection techniques applied to interictal MEG data often discover several potentially epileptogenic brain regions. An important determination in treatment planning is which of these detected regions are most likely to be the primary sources of epileptogenic activity...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/14/017

    authors: Ossadtchi A,Mosher JC,Sutherling WW,Greenblatt RE,Leahy RM

    更新日期:2005-07-21 00:00:00

  • Development and comparison of computer methods for organ motion correction in scintigraphy.

    abstract::The process of organ motion correction in scintigraphy is analysed in the frequency domain. The sequence of the chi- and gamma- coordinates registered during scintigraphic recording is converted to a frequency spectrum by a discrete Fourier transform. In the frequency domain motion correction is performed by linear fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/3/010

    authors: Schmidlin P

    更新日期:1975-05-01 00:00:00

  • Estimation of renal scintigraphy parameters using a linear piecewise-continuous model.

    abstract::Instead of performing a numerical deconvolution, we propose to use a linear piecewise-continuous model of the renal impulse response function for parametric fitting of renal scintigraphy data, to obtain clinically useful renal parameters. The strengths of the present model are its simplicity and speed of computation, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/402

    authors: Zhang JL,Zhang L,Koh TS,Shuter B

    更新日期:2003-06-21 00:00:00

  • Hybrid scatter correction applied to quantitative holmium-166 SPECT.

    abstract::Ho-166 is a combined beta-gamma emitter of which the betas can be used therapeutically. From the 81 keV gammas of Ho-166, SPECT images can be obtained, which give opportunities to guide Ho-166 therapy. Accurate reconstruction of Ho-166 images is currently hampered by photopeak-scatter in the patient, down-scatter in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/004

    authors: de Wit TC,Xiao J,Nijsen JF,van het Schip FD,Staelens SG,van Rijk PP,Beekman FJ

    更新日期:2006-10-07 00:00:00

  • Mucosal deformation from an impinging transonic gas jet and the ballistic impact of microparticles.

    abstract::By means of a transonic gas jet, gene guns ballistically deliver microparticle formulations of drugs and vaccines to the outer layers of the skin or mucosal tissue to induce unique physiological responses for the treatment of a range of conditions. Reported high-speed imaging experiments show that the mucosa deforms s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/19/010

    authors: Hardy MP,Kendall MA

    更新日期:2005-10-07 00:00:00

  • Laboratory prototype for experimental validation of MR-guided radiofrequency head and neck hyperthermia.

    abstract::Clinical studies have established a strong benefit from adjuvant mild hyperthermia (HT) to radio- and chemotherapy for many tumor sites, including the head and neck (H&N). The recently developed HYPERcollar allows the application of local radiofrequency HT to tumors in the entire H&N. Treatment quality is optimized us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/2139

    authors: Paulides MM,Bakker JF,Hofstetter LW,Numan WC,Pellicer R,Fiveland EW,Tarasek M,Houston GC,van Rhoon GC,Yeo DT,Kotek G

    更新日期:2014-05-07 00:00:00

  • Relating two techniques for handling uncertainties in IMRT optimization.

    abstract::Radiotherapy treatment planning is associated with uncertainties. Examples are uncertainties in the tumour location due to organ movement or the inter/intra observer variability in target definition. Different approaches to incorporate uncertainties into IMRT optimization have been proposed. In this note, we point out...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/N04

    authors: Unkelbach J,Oelfke U

    更新日期:2006-12-07 00:00:00

  • The validation of tomotherapy dose calculations in low-density lung media.

    abstract::The dose-calculation accuracy of the tomotherapy Hi-Art II(R) (Tomotherapy, Inc., Madison, WI) treatment planning system (TPS) in the presence of low-density lung media was investigated. In this evaluation, a custom-designed heterogeneous phantom mimicking the mediastinum geometry was used. Gammex LN300 and balsa wood...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/004

    authors: Chaudhari SR,Pechenaya OL,Goddu SM,Mutic S,Rangaraj D,Bradley JD,Low D

    更新日期:2009-04-21 00:00:00

  • Modelling pencil-beam divergence with the electron pencil-beam redefinition algorithm.

    abstract::The electron pencil-beam redefinition algorithm (PBRA), which is used to calculate electron beam dose distributions, assumes that the virtual source of each pencil beam is identical to that of the broad beam incident on the patient. In the present work, a virtual source specific for each pencil beam is modelled by inc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/11/306

    authors: Boyd RA,Hogstrom KR,White RA,Starkschall G

    更新日期:2001-11-01 00:00:00

  • Magnetic resonance electrical property mapping at 21.1 T: a study of conductivity and permittivity in phantoms, ex vivo tissue and in vivo ischemia.

    abstract::Electrical properties (EP), namely conductivity and permittivity, can provide endogenous contrast for tissue characterization. Using electrical property tomography (EPT), maps of EP can be generated from conventional MRI data. This report investigates the feasibility and accuracy of EPT at 21.1 T for multiple RF coils...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3259

    authors: Amouzandeh G,Mentink-Vigier F,Helsper S,Bagdasarian FA,Rosenberg JT,Grant SC

    更新日期:2020-02-28 00:00:00

  • A method for estimating radiation interaction coefficients for tissues from single energy CT.

    abstract::A parametric model for the x-ray linear attenuation coefficient is used to describe the compositional dependence of Hounsfield numbers measured by medical CT scanners. Measurements with materials of known density and composition, that span and evenly sample the compositional range of tissues, are written as linear sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/23/7479

    authors: Midgley SM

    更新日期:2014-12-07 00:00:00