Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.

Abstract:

:We present the results of utilizing aligned anatomical information from CT images to locally adjust image smoothness during the reconstruction of three-dimensional (3D) whole-body positron emission tomography (PET) data. The ability of whole-body PET imaging to detect malignant neoplasms is becoming widely recognized. Potentially useful, however, is the role of whole-body PET in quantitative estimation of tracer uptake. The utility of PET in oncology is often limited by the high level of statistical noise in the images. Reduction in noise can be obtained by incorporating a priori image smoothness information from correlated anatomical information during the reconstruction of PET data. A combined PET/CT scanner allows the acquisition of accurately aligned PET and x-ray CT whole-body data. We use the Fourier rebinning algorithm (FORE) to accurately convert the 3D PET data to two-dimensional (2D) data to accelerate the image reconstruction process. The 2D datasets are reconstructed with successive over-relaxation of a penalized weighted least squares (PWLS) objective function to model the statistics of the acquisition, data corrections, and rebinning. A 3D voxel label model is presented that incorporates the anatomical information via the penalty weights of the PWLS objective function. This combination of FORE + PWLS + labels was developed as it allows for both reconstruction of 3D whole-body data sets in clinically feasible times and also the inclusion of anatomical information in such a way that convergence can be guaranteed. Since mismatches between anatomical (CT) and functional (PET) data are unavoidable in practice, the labels are 'blurred' to reflect the uncertainty associated with the anatomical information. Simulated and experimental results show the potential advantage of incorporating anatomical information by using blurred labels to calculate the penalty weights. We conclude that while the effect of this method on detection tasks is complicated and unclear, there is an improvement on the estimation task.

journal_name

Phys Med Biol

authors

Comtat C,Kinahan PE,Fessler JA,Beyer T,Townsend DW,Defrise M,Michel C

doi

10.1088/0031-9155/47/1/301

subject

Has Abstract

pub_date

2002-01-07 00:00:00

pages

1-20

issue

1

eissn

0031-9155

issn

1361-6560

journal_volume

47

pub_type

杂志文章
  • Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery.

    abstract::A micro-multileaf collimator (microMLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the microMLC does not allow 'direct'...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/15/305

    authors: Treuer H,Hoevels M,Luyken K,Hunsche S,Kocher M,Müller RP,Sturm V

    更新日期:2003-08-07 00:00:00

  • Modelling the temporal region in patients with temporal lobe epilepsy.

    abstract::EEG interictal epileptiform discharges in temporal lobe epilepsy are associated with magnetic fields. The maxima of magnetic spikes recorded over the spherical portions of the head appear fairly symmetric, whereas those over the lower temporal region often have irregular shapes. Furthermore, their magnitude is often u...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/1/009

    authors: Rose DF,Sato S,Smith PD,White J

    更新日期:1987-01-01 00:00:00

  • Kinetic filtering of [(18)F]Fluorothymidine in positron emission tomography studies.

    abstract::[(18)F]Fluorothymidine (FLT) is a cell proliferation marker that undergoes predominantly hepatic metabolism and therefore shows a high level of accumulation in the liver, as well as in rapidly proliferating tumours. Furthermore, the tracer's uptake is substantial in other organs including the heart. We present a nonli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/3/010

    authors: Gray KR,Contractor KB,Kenny LM,Al-Nahhas A,Shousha S,Stebbing J,Wasan HS,Coombes RC,Aboagye EO,Turkheimer FE,Rosso L

    更新日期:2010-02-07 00:00:00

  • In vitro double-integrating-sphere optical properties of tissues between 630 and 1064 nm.

    abstract::The optical properties (absorption and scattering coefficients and the scattering anisotropy factor) were measured in vitro for cartilage, liver, lung, muscle, myocardium, skin, and tumour (colon adenocarcinoma CC 531) at 630, 632.8, 790, 850 and 1064 nm. Rabbits, rats, piglets, goats, and dogs were used to obtain the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/11/017

    authors: Beek JF,Blokland P,Posthumus P,Aalders M,Pickering JW,Sterenborg HJ,van Gemert MJ

    更新日期:1997-11-01 00:00:00

  • Prediction of dose-volume histograms in nasopharyngeal cancer IMRT using geometric and dosimetric information.

    abstract::A method using both patient geometric and dosimetric information was proposed to predict dose-volume histograms (DVHs) of organs at risk (OARs) for a nasopharyngeal cancer (NPC) intensity-modulated radiation therapy (IMRT) plan. A total of 106 nine-field IMRT NPC plans were used in this study. Twenty-six plans were ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab50eb

    authors: Jiao SX,Chen LX,Zhu JH,Wang ML,Liu XW

    更新日期:2019-12-05 00:00:00

  • Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator.

    abstract::Multileaf collimators (MLCs) have been in clinical use for many years and meanwhile are commonly used to deliver intensity-modulated radiotherapy (IMRT) beams. For this purpose it is important to know their dosimetric properties precisely, one of them being inter- and intraleaf leakage. The Siemens 160 MLC features a ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/2/N02

    authors: Klüter S,Sroka-Perez G,Schubert K,Debus J

    更新日期:2011-01-21 00:00:00

  • Dose rate calculations around 192Ir brachytherapy sources using a Sievert integration model.

    abstract::The classical Sievert integral method is a valuable tool for dose rate calculations around brachytherapy sources, combining simplicity with reasonable computational times. However, its accuracy in predicting dose rate anisotropy around 192Ir brachytherapy sources has been repeatedly put into question. In this work, we...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/2/309

    authors: Karaiskos P,Angelopoulos A,Baras P,Rozaki-Mavrouli H,Sandilos P,Vlachos L,Sakelliou L

    更新日期:2000-02-01 00:00:00

  • Prospects for in vivo Raman spectroscopy.

    abstract::Raman spectroscopy is a potentially important clinical tool for real-time diagnosis of disease and in situ evaluation of living tissue. The purpose of this article is to review the biological and physical basis of Raman spectroscopy of tissue, to assess the current status of the field and to explore future directions....

    journal_title:Physics in medicine and biology

    pub_type: 传,历史文章,杂志文章,评审

    doi:10.1088/0031-9155/45/2/201

    authors: Hanlon EB,Manoharan R,Koo TW,Shafer KE,Motz JT,Fitzmaurice M,Kramer JR,Itzkan I,Dasari RR,Feld MS

    更新日期:2000-02-01 00:00:00

  • PET monitoring of cancer therapy with 3He and 12C beams: a study with the GEANT4 toolkit.

    abstract::We study the spatial distributions of beta(+)-activity produced by therapeutic beams of (3)He and (12)C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for heavy-ion therapy (MCHIT) based on the GEANT4 toolkit. The contributions from positron-emitting nuclei with T(1/2...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/24/007

    authors: Pshenichnov I,Larionov A,Mishustin I,Greiner W

    更新日期:2007-12-21 00:00:00

  • HeinzelCluster: accelerated reconstruction for FORE and OSEM3D.

    abstract::Using iterative three-dimensional (3D) reconstruction techniques for reconstruction of positron emission tomography (PET) is not feasible on most single-processor machines due to the excessive computing time needed, especially so for the large sinogram sizes of our high-resolution research tomograph (HRRT). In our fir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/15/307

    authors: Vollmar S,Michel C,Treffert JT,Newport DF,Casey M,Knöss C,Wienhard K,Liu X,Defrise M,Heiss WD

    更新日期:2002-08-07 00:00:00

  • Laser shaping of corneal transplants in vitro: area ablation with small overlapping laser spots produced by a pulsed scanning laser beam using an optimizing ablation algorithm.

    abstract::Area laser lathing and trephination of donor corneas is used to produce different types of grafts for human transplantation. 193 nm (ArF excimer) laser radiation is used, since this is known to give a non-thermal laser-tissue interaction with a minimal zone of tissue damage. To guarantee the highest degree of flexibil...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/5/005

    authors: Homolka P,Biowski R,Kaminski S,Barisani T,Husinsky W,Bergmann H,Grabner G

    更新日期:1999-05-01 00:00:00

  • Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis.

    abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5452

    authors: Tyagi N,Fontenla S,Zhang J,Cloutier M,Kadbi M,Mechalakos J,Zelefsky M,Deasy J,Hunt M

    更新日期:2017-04-21 00:00:00

  • On the total system error of a robotic radiosurgery system: phantom measurements, clinical evaluation and long-term analysis.

    abstract::The total system error (TSE) of a CyberKnife® system was measured using two phantom-based methods and one patient-based method. The standard radiochromic film (RCF) end-to-end (E2E) test using an anthropomorphic head and neck phantom and isocentric treatment delivery was used with the 6Dskull, Fiducial and Xsight® spi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad516

    authors: Pantelis E,Moutsatsos A,Antypas C,Zoros E,Pantelakos P,Lekas L,Romanelli P,Zourari K,Hourdakis CJ

    更新日期:2018-08-20 00:00:00

  • Ionization chamber correction factors for MR-linacs.

    abstract::Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to system...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac4f2

    authors: Pojtinger S,Dohm OS,Kapsch RP,Thorwarth D

    更新日期:2018-06-07 00:00:00

  • Feasibility of salvage interstitial microwave thermal therapy for prostate carcinoma following failed brachytherapy: studies in a tissue equivalent phantom.

    abstract::Thermal therapy is an experimental treatment to destroy solid tumours by heating them to temperatures ranging from 55 degrees C to 90 degrees C, inducing thermal coagulation and necrosis of the tumour. We are investigating the feasibility of interstitial microwave thermal therapy as a salvage treatment for prostate ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/8/306

    authors: McCann C,Kumaradas JC,Gertner MR,Davidson SR,Dolan AM,Sherar MD

    更新日期:2003-04-21 00:00:00

  • The electromagnetic response of human skin in the millimetre and submillimetre wave range.

    abstract::Recent studies of the minute morphology of the skin by optical coherence tomography revealed that the sweat ducts in human skin are helically shaped tubes, filled with a conductive aqueous solution. This, together with the fact that the dielectric permittivity of the dermis is higher than that of the epidermis, brings...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/11/005

    authors: Feldman Y,Puzenko A,Ben Ishai P,Caduff A,Davidovich I,Sakran F,Agranat AJ

    更新日期:2009-06-07 00:00:00

  • Low density contrast agents for x-ray phase contrast imaging: the use of ambient air for x-ray angiography of excised murine liver tissue.

    abstract::We report a new preparative method for providing contrast through reduction in electron density that is uniquely suited for propagation-based differential x-ray phase contrast imaging. The method, which results in an air or fluid filled vasculature, makes possible visualization of the smallest microvessels, roughly do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/23/017

    authors: Laperle CM,Hamilton TJ,Wintermeyer P,Walker EJ,Shi D,Anastasio MA,Derdak Z,Wands JR,Diebold G,Rose-Petruck C

    更新日期:2008-12-07 00:00:00

  • Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm.

    abstract::A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/1/312

    authors: Bloch P,Altschuler MD,Bjärngard BE,Kassaee A,McDonough J

    更新日期:2000-01-01 00:00:00

  • Motion induced interplay effects for VMAT radiotherapy.

    abstract::The purpose of this study was to develop a method to simulate breathing motion induced interplay effects for volumetric modulated arc therapy (VMAT), to verify the proposed method with measurements, and to use the method to investigate how interplay effects vary with different patient- and machine specific parameters....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab957

    authors: Edvardsson A,Nordström F,Ceberg C,Ceberg S

    更新日期:2018-04-19 00:00:00

  • New compensator design options for charged-particle radiotherapy.

    abstract::The purpose of this investigation is to propose new compensator design strategies for protons and heavier particles which are based on pencil-beam (PB) dose calculations and which significantly reduce the dose to tissues downstream from the target, yet provide acceptable target coverage under conditions of patient mot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/7/005

    authors: Petti PL

    更新日期:1997-07-01 00:00:00

  • High-resolution numerical model of the middle and inner ear for a detailed analysis of radio frequency absorption.

    abstract::In order to enable a detailed analysis of radio frequency (RF) absorption in the human middle and inner ear organs, a numerical model of these organs was developed at a spatial resolution of 0.1 mm, based on a real human tissue sample. The dielectric properties of the liquids (perilymph and endolymph) inside the bony ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/7/001

    authors: Schmid G,Uberbacher R,Samaras T,Jappel A,Baumgartner WD,Tschabitscher M,Mazal PR

    更新日期:2007-04-07 00:00:00

  • Use of an amorphous silicon EPID for measuring MLC calibration at varying gantry angle.

    abstract::Amorphous silicon electronic portal imaging devices (EPIDs) are used to perform routine quality control (QC) checks on the multileaf collimators (MLCs) at this centre. Presently, these checks are performed at gantry angle 0 degrees and are considered to be valid for all other angles. Since therapeutic procedures regul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/2/013

    authors: Clarke MF,Budgell GJ

    更新日期:2008-01-21 00:00:00

  • Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design.

    abstract::In this paper, we present simulation studies for the second-generation MRI compatible SPECT system, MRC-SPECT-II, based on an inverted compound eye (ICE) gamma camera concept. The MRC-SPECT-II system consists of a total of 1536 independent micro-pinhole-camera-elements (MCEs) distributed in a ring with an inner diamet...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa4fb

    authors: Lai X,Meng LJ

    更新日期:2018-02-12 00:00:00

  • Another decade of photoacoustic imaging.

    abstract::Photoacoustic imaging - a hybrid biomedical imaging modality finding its way to clinical practices. Although the photoacoustic phenomenon was known more than a century back, only in the last two decades it has been widely researched and used for biomedical imaging applications. In this review we focus on the developme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abd669

    authors: Das D,Sharma A,Rajendran P,Pramanik M

    更新日期:2020-12-23 00:00:00

  • A water calorimeter for neutron dosimetry.

    abstract::A water calorimeter has been used for the direct measurement of absorbed dose to water in a d(15) + Be neutron beam. The absorbed dose measured with the calorimeter was compared with that measured with an Exradin ionisation chamber, constructed of A-150 plastic. The doses measured by the ionisation chamber were calcul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/005

    authors: Galloway G,Greening JR,Williams JR

    更新日期:1986-04-01 00:00:00

  • Quantitation in SPECT using an effective model of the scattering.

    abstract::A new method for correcting simultaneously the attenuation, scatter and resolution effects in SPECT has been developed for the case of a homogeneous medium. It is based on an effective model of the scatter process. This model depends on only four parameters which are determined experimentally and remain independent of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/4/005

    authors: Walrand SH,van Elmbt LR,Pauwels S

    更新日期:1994-04-01 00:00:00

  • A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field.

    abstract::Existing studies have suggested some debate on whether the quality of radiation that delivers dose outside of the primary field of a radiotherapy photon beam can be considered the same as that inside the primary field. We used a Monte Carlo approach to simulate the electron fluence differential in energy inside a wate...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/12/015

    authors: Kirkby C,Field C,MacKenzie M,Syme A,Fallone BG

    更新日期:2007-06-21 00:00:00

  • Assessment of histotripsy-induced liquefaction with diagnostic ultrasound and magnetic resonance imaging in vitro and ex vivo.

    abstract::Histotripsy is a therapeutic ultrasound modality under development to liquefy tissue mechanically via bubble clouds. Image guidance of histotripsy requires both quantification of the bubble cloud activity and accurate delineation of the treatment zone. In this study, magnetic resonance (MR) and diagnostic ultrasound i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab143f

    authors: Anthony GJ,Bollen V,Hendley S,Antic T,Sammet S,Bader KB

    更新日期:2019-05-02 00:00:00

  • Segmentation and classification of thyroid follicular neoplasm using cascaded convolutional neural network.

    abstract::In this paper, we present a segmentation and classification method for thyroid follicular neoplasms based on a combination of the prior-based level set method and deep convolutional neural network. The proposed method aims to discriminate thyroid follicular adenoma (TFA) and follicular thyroid carcinoma (FTC) in ultra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc6f2

    authors: Yang B,Yan M,Yan Z,Zhu C,Xu D,Dong F

    更新日期:2020-11-02 00:00:00

  • Four-dimensional Monte Carlo simulation of time-dependent geometries.

    abstract::Dynamic radiation therapy techniques require that the treatment head setup varies in time and space during dose delivery. Examples are leaf motion in intensity modulated x-ray therapy, modulator wheel rotation in conventional proton therapy and variable magnet settings in proton beam scanning. Consequently, for Monte ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/6/n03

    authors: Paganetti H

    更新日期:2004-03-21 00:00:00