New compensator design options for charged-particle radiotherapy.

Abstract:

:The purpose of this investigation is to propose new compensator design strategies for protons and heavier particles which are based on pencil-beam (PB) dose calculations and which significantly reduce the dose to tissues downstream from the target, yet provide acceptable target coverage under conditions of patient motion. Averaging and expansion operations are provided to improve the target coverage if the patient moves slightly during treatment, and a structure-sparing option is provided to protect critical structures lying downstream from the target. The new compensator design options were evaluated for two patients who had skull-base tumours. When the patient and compensator were perfectly aligned, the new PB compensator designs provided target coverage comparable to, if not better than, standard compensator designs for both patients. Furthermore, the volume of normal tissue distal to the target which received in excess of 95% of the prescription dose was roughly a factor of two lower for the averaged PB compensators than for the expanded standard compensators. In the event of patient motion, on average, the volume of the target receiving 95% or more of the prescribed dose was 3% less for the averaged PB compensators than for the expanded standard compensators. In conclusion, the new compensator design options evaluated in this investigation provide better protection for normal tissues distal to the target volume than standard compensator designs, with only a modest decrease in target volume coverage in the event of patient motion.

journal_name

Phys Med Biol

authors

Petti PL

doi

10.1088/0031-9155/42/7/005

subject

Has Abstract

pub_date

1997-07-01 00:00:00

pages

1289-300

issue

7

eissn

0031-9155

issn

1361-6560

journal_volume

42

pub_type

杂志文章
  • Physics considerations in MV-CBCT multi-layer imager design.

    abstract::Megavoltage (MV) cone-beam computed tomography (CBCT) using an electronic portal imaging (EPID) offers advantageous features, including 3D mapping, treatment beam registration, high-z artifact suppression, and direct radiation dose calculation. Adoption has been slowed by image quality limitations and concerns about i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac8c6

    authors: Hu YH,Fueglistaller R,Myronakis M,Rottmann J,Wang A,Shedlock D,Morf D,Baturin P,Huber P,Star-Lack J,Berbeco R

    更新日期:2018-06-20 00:00:00

  • Evaluation of inverse methods and head models for EEG source localization using a human skull phantom.

    abstract::We used a real-skull phantom head to investigate the performances of representative methods for EEG source localization when considering various head models. We describe several experiments using a montage with current sources located at multiple positions and orientations inside a human skull filled with a conductive...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/1/306

    authors: Baillet S,Riera JJ,Marin G,Mangin JF,Aubert J,Garnero L

    更新日期:2001-01-01 00:00:00

  • Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means.

    abstract::The x-ray exposure to patients has become a major concern in computed tomography (CT) and minimizing the radiation exposure has been one of the major efforts in the CT field. Due to plenty high-attenuation tissues in the human chest, under low-dose scan protocols, thoracic low-dose CT (LDCT) images tend to be severely...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2667

    authors: Chen Y,Yang Z,Hu Y,Yang G,Zhu Y,Li Y,Luo L,Chen W,Toumoulin C

    更新日期:2012-05-07 00:00:00

  • The modelling of biological systems in three dimensions using the time domain finite-difference method: I. The implementation of the model.

    abstract::A computer method has been developed which uses the time domain finite-difference (TDFD) algorithm to calculate the deposition of the electromagnetic (EM) field in three-dimensional biological models. This, the first of two papers, describes the algorithm and the computer programs developed. The method is demonstrated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/11/006

    authors: Lau RW,Sheppard RJ

    更新日期:1986-11-01 00:00:00

  • Medical staff extremity dosimetry in CT fluoroscopy: an anthropomorphic hand voxel phantom study.

    abstract::This work aims to contribute to the study of the radiation dose distribution delivered to the hands of medical staff members during a general computed tomographic (CT) fluoroscopic guided procedure. In this study, both Monte Carlo simulations and measurements were performed. For free-in-air and computed tomography dos...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/16/5433

    authors: Figueira C,Becker F,Blunck C,DiMaria S,Baptista M,Esteves B,Paulo G,Santos J,Teles P,Vaz P

    更新日期:2013-08-21 00:00:00

  • Optimization of a depth of interaction encoding PET block detector for a PET/MRI insert.

    abstract::Preclinical positron emission tomography, combined with magnetic resonance imaging (PET/MRI), is increasingly used as a tool to simultaneously characterize functional processes in vivo. Many emerging preclinical applications, however, are limited by PET detection sensitivity, especially when generating short imaging f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaef59

    authors: Selfridge AR,Cherry SR,Judenhofer MS

    更新日期:2018-12-06 00:00:00

  • Optimization of the accuracy of retention and washout measurements of 99mTc-Sestamibi from breast tumours using an anthropomorphic phantom.

    abstract::Quantifying the retention or washout of (99m)Tc-Sestamibi (MIBI) in breast tumours in vivo may provide a basis for predicting the chemotherapy response. The aim of this study is to investigate the variations and limitations of the different methods used to quantify these parameters. A phantom was developed that allowe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/9/013

    authors: Marshall C,Griffiths PA

    更新日期:2005-05-07 00:00:00

  • Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system.

    abstract::The purpose of this work was to use Monte Carlo simulations to verify the accuracy of the dose distributions from a commercial treatment planning optimization system (Corvus, Nomos Corp., Sewickley, PA) for intensity-modulated radiotherapy (IMRT). A Monte Carlo treatment planning system has been implemented clinically...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/9/303

    authors: Ma CM,Pawlicki T,Jiang SB,Li JS,Deng J,Mok E,Kapur A,Xing L,Ma L,Boyer AL

    更新日期:2000-09-01 00:00:00

  • An image processing technique for the identification of contact pixels applied to x-ray CT images of implanted hip prostheses.

    abstract::Uncemented prosthetic joint implants used in orthopaedic surgery are usually coated with a porous surface to encourage bone ingrowth. Better contact between the endosteal bone and the porous surface improves ingrowth, and such contact may be increased if the joint further subsides into position in the first weeks foll...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/2/009

    authors: Berry E,Langkamer VG,Jackson PC,Snow M,Goddard PR,Wells PN

    更新日期:1993-02-01 00:00:00

  • Transport-based quantitative photoacoustic tomography: simulations and experiments.

    abstract::In this paper we describe a method for quantitative photoacoustic tomography (qPAT) based on the photon radiative transfer equation (RTE) coupled with the Helmholtz photoacoustic wave equation. Considerable simulations and tissue-like phantom experiments are conducted to evaluate transport-based qPAT in comparison wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/7/009

    authors: Yao L,Sun Y,Jiang H

    更新日期:2010-04-07 00:00:00

  • Automatic generation of time resolved motion vector fields of coronary arteries and 4D surface extraction using rotational x-ray angiography.

    abstract::Rotational coronary angiography provides a multitude of x-ray projections of the contrast agent enhanced coronary arteries along a given trajectory with parallel ECG recording. These data can be used to derive motion information of the coronary arteries including vessel displacement and pulsation. In this paper, a ful...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/004

    authors: Jandt U,Schäfer D,Grass M,Rasche V

    更新日期:2009-01-07 00:00:00

  • Evaluation of a ferrous benzoic xylenol orange transparent PVA cryogel radiochromic dosimeter.

    abstract::A stable cryogel dosimeter was prepared using ferrous benzoic xylenol orange (FBX) in a transparent poly-(vinyl alcohol) (PVA) cryogel matrix. Dose response was evaluated for different numbers of freeze-thaw cycles (FTCs), different concentrations of PVA, and ratios of water/dimethyl sulfoxide. Linear relationships be...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1773

    authors: Eyadeh MM,Farrell TJ,Diamond KR

    更新日期:2014-04-07 00:00:00

  • A quantitative assessment of the depth sensitivity of an optical topography system using a solid dynamic tissue-phantom.

    abstract::A solid dynamic phantom with tissue-like optical properties is presented, which contains seven discrete targets impregnated with thermochromic pigment located at different depths from the surface. Changes in absorption are obtained in response to localized heating of the targets, simulating haemodynamic changes occurr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/20/016

    authors: Correia T,Banga A,Everdell NL,Gibson AP,Hebden JC

    更新日期:2009-10-21 00:00:00

  • Experimental study on the influence of the central electrode in Farmer-type ionization chambers.

    abstract::In the IAEA TRS-381 protocol, k(cel) and p(cel) account for the central electrode perturbation during the air kerma chamber calibration and the in-phantom measurements. The values of these correction factors are based mainly on Monte Carlo simulations. In the present work experimental data on k(cel) and p(cel) for the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/5/315

    authors: Palm A,Mattsson O

    更新日期:1999-05-01 00:00:00

  • Prediction of lung tumor motion using nonlinear autoregressive model with exogenous input.

    abstract::The present note addresses the development of a lung tumor position predictor to be used in dynamic tumor tracking radiotherapy, abbreviated as DTT-RT. As there exists 50-500 ms positioning lag in the control of the multi-leaf collimator (MLC) of commercial medical linear accelerators, prediction of future lung tumor ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab49ea

    authors: Jiang K,Fujii F,Shiinoki T

    更新日期:2019-10-31 00:00:00

  • Comparison of blood velocity measurements between ultrasound Doppler and accelerated phase-contrast MR angiography in small arteries with disturbed flow.

    abstract::Ultrasound Doppler (UD) velocity measurements are commonly used to quantify blood flow velocities in vivo. The aim of our work was to investigate the accuracy of in vivo spectral Doppler measurements of velocity waveforms. Waveforms were derived from spectral Doppler signals and corrected for intrinsic spectral broade...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/6/015

    authors: Jiang J,Strother C,Johnson K,Baker S,Consigny D,Wieben O,Zagzebski J

    更新日期:2011-03-21 00:00:00

  • Factors affecting the repeatability of gamma camera calibration for quantitative imaging applications using a sealed source.

    abstract::Several applications in nuclear medicine require absolute activity quantification of single photon emission computed tomography images. Obtaining a repeatable calibration factor that converts voxel values to activity units is essential for these applications. Because source preparation and measurement of the source ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1325

    authors: Anizan N,Wang H,Zhou XC,Wahl RL,Frey EC

    更新日期:2015-02-07 00:00:00

  • Feasibility of salvage interstitial microwave thermal therapy for prostate carcinoma following failed brachytherapy: studies in a tissue equivalent phantom.

    abstract::Thermal therapy is an experimental treatment to destroy solid tumours by heating them to temperatures ranging from 55 degrees C to 90 degrees C, inducing thermal coagulation and necrosis of the tumour. We are investigating the feasibility of interstitial microwave thermal therapy as a salvage treatment for prostate ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/8/306

    authors: McCann C,Kumaradas JC,Gertner MR,Davidson SR,Dolan AM,Sherar MD

    更新日期:2003-04-21 00:00:00

  • A new column-generation-based algorithm for VMAT treatment plan optimization.

    abstract::We study the treatment plan optimization problem for volumetric modulated arc therapy (VMAT). We propose a new column-generation-based algorithm that takes into account bounds on the gantry speed and dose rate, as well as an upper bound on the rate of change of the gantry speed, in addition to MLC constraints. The alg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4569

    authors: Peng F,Jia X,Gu X,Epelman MA,Romeijn HE,Jiang SB

    更新日期:2012-07-21 00:00:00

  • Quantitative x-ray dark-field computed tomography.

    abstract::The basic principles of x-ray image formation in radiology have remained essentially unchanged since Röntgen first discovered x-rays over a hundred years ago. The conventional approach relies on x-ray attenuation as the sole source of contrast and draws exclusively on ray or geometrical optics to describe and interpre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/017

    authors: Bech M,Bunk O,Donath T,Feidenhans'l R,David C,Pfeiffer F

    更新日期:2010-09-21 00:00:00

  • Truncation artifact suppression in cone-beam radionuclide transmission CT using maximum likelihood techniques: evaluation with human subjects.

    abstract::Transverse image truncation can be a serious problem for human imaging using cone-beam transmission CT (CB-CT) implemented on a conventional rotating gamma camera. If this problem can be solved, CB-CT will be useful for attenuation compensation of SPECT images. This paper presents a reconstruction method to reduce or ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/3/004

    authors: Manglos SH

    更新日期:1992-03-01 00:00:00

  • Spinal pedicle screw planning using deformable atlas registration.

    abstract::Spinal screw placement is a challenging task due to small bone corridors and high risk of neurological or vascular complications, benefiting from precision guidance/navigation and quality assurance (QA). Implicit to both guidance and QA is the definition of a surgical plan-i.e. the desired trajectories and device sele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5f42

    authors: Goerres J,Uneri A,De Silva T,Ketcha M,Reaungamornrat S,Jacobson M,Vogt S,Kleinszig G,Osgood G,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-07 00:00:00

  • Modeling late rectal toxicities based on a parameterized representation of the 3D dose distribution.

    abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/013

    authors: Buettner F,Gulliford SL,Webb S,Partridge M

    更新日期:2011-04-07 00:00:00

  • The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging.

    abstract::Our aim is to investigate the impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging using a population of patient respiratory traces. A total of 1295 respiratory traces acquired during whole body PET/CT imaging were classified into three types according to the qualitative shape ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/24/007

    authors: Liu C,Pierce LA 2nd,Alessio AM,Kinahan PE

    更新日期:2009-12-21 00:00:00

  • Improved procedure for neuromagnetic localisation.

    abstract::We describe an improved algorithm for localising equivalent sources of biomagnetic fields in the human brain. The algorithm is an improvement over the sphere model in that it considers two distinct surfaces: an ellipsoid, to model the region of the skull on which the sensors are placed, and a sphere as the medium in w...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/1/017

    authors: Pistella F,Barone P,Narici L,Ocello N,Pizzella V,Romani GL

    更新日期:1987-01-01 00:00:00

  • A multi-frequency sparse hemispherical ultrasound phased array for microbubble-mediated transcranial therapy and simultaneous cavitation mapping.

    abstract::Focused ultrasound (FUS) phased arrays show promise for non-invasive brain therapy. However, the majority of them are limited to a single transmit/receive frequency and therefore lack the versatility to expose and monitor the treatment volume. Multi-frequency arrays could offer variable transmit focal sizes under a fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/24/8476

    authors: Deng L,O'Reilly MA,Jones RM,An R,Hynynen K

    更新日期:2016-12-21 00:00:00

  • Performance measurements of a high-spatial-resolution YAP camera.

    abstract::Physical properties of a position-sensitive camera for the analysis of biodistributions of gamma- and beta-emitting radiopharmaceuticals in small animals have been studied, in order to achieve optimal operating conditions. The camera consisted of a highly segmented yttrium-aluminate perovskite (YAP) scintillator, coup...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/3/n01

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Baldazzi G,Bollini D,de Notaristefani F,Mazzi U,Riondato M

    更新日期:2005-02-07 00:00:00

  • Ultrasound scattering from spherical tumours.

    abstract::The interaction of biomedical ultrasound with spherical tumours in the human body is investigated using analytic methods which predict the angular distribution of the ultrasound scattered by the tumour. Both the tumour and the surrounding tissue are considered to be lossy elastic media, which support shear-wave modes ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/11/001

    authors: Hinders MK,Collins JJ,Collins MM,Fang TM,Sandri GV

    更新日期:1992-11-01 00:00:00

  • Postirradiation effects in alanine dosimeter probes of two different suppliers.

    abstract::The measurand relevant for the dosimetry for radiation therapy is the absorbed dose to water, DW. The Physikalisch-Technische Bundesanstalt (PTB) is establishing a secondary standard for DW for high-energy photon and electron radiation based on electron spin resonance (ESR) of the amino acid alanine. For practical app...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/5/006

    authors: Anton M

    更新日期:2008-03-07 00:00:00

  • Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors.

    abstract::We are developing a three-dimensional (3D) position-sensitive detector with isotropic spatial resolution, the X'tal cube. Originally, our design consisted of a crystal block for which all six surfaces were covered with arrays of multi-pixel photon counters (MPPCs). In this paper, we examined the feasibility of reducin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/5/1361

    authors: Hirano Y,Inadama N,Yoshida E,Nishikido F,Murayama H,Watanabe M,Yamaya T

    更新日期:2013-03-07 00:00:00