The electromagnetic response of human skin in the millimetre and submillimetre wave range.

Abstract:

:Recent studies of the minute morphology of the skin by optical coherence tomography revealed that the sweat ducts in human skin are helically shaped tubes, filled with a conductive aqueous solution. This, together with the fact that the dielectric permittivity of the dermis is higher than that of the epidermis, brings forward the supposition that as electromagnetic entities, the sweat ducts could be regarded as low Q helical antennas. The implications of this statement were further investigated by electromagnetic simulation and experiment of the in vivo reflectivity of the skin of subjects under varying physiological conditions (Feldman et al 2008 Phys. Rev. Lett. 100 128102). The simulation and experimental results are in a good agreement and both demonstrate that sweat ducts in the skin could indeed behave as low Q antennas. Thus, the skin spectral response in the sub-Terahertz region is governed by the level of activity of the perspiration system and shows the minimum of reflectivity at some frequencies in the frequency band of 75-110 GHz. It is also correlated to physiological stress as manifested by the pulse rate and the systolic blood pressure. As such, it has the potential to become the underlying principle for remote sensing of the physiological parameters and the mental state of the examined subject.

journal_name

Phys Med Biol

authors

Feldman Y,Puzenko A,Ben Ishai P,Caduff A,Davidovich I,Sakran F,Agranat AJ

doi

10.1088/0031-9155/54/11/005

subject

Has Abstract

pub_date

2009-06-07 00:00:00

pages

3341-63

issue

11

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(09)01713-8

journal_volume

54

pub_type

杂志文章
  • Intraventricular vector flow mapping-a Doppler-based regularized problem with automatic model selection.

    abstract::We propose a regularized least-squares method for reconstructing 2D velocity vector fields within the left ventricular cavity from single-view color Doppler echocardiographic images. Vector flow mapping is formulated as a quadratic optimization problem based on an [Formula: see text]-norm minimization of a cost functi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7fe7

    authors: Assi KC,Gay E,Chnafa C,Mendez S,Nicoud F,Abascal JFPJ,Lantelme P,Tournoux F,Garcia D

    更新日期:2017-08-11 00:00:00

  • Intensity of the flash associated with laser-induced plasma in the eye.

    abstract::A bright flash of light is emitted by the plasma formed at the focus of an ophthalmic Nd: YAG laser. The purpose of this investigation is to determine whether the plasma flash constitutes a hazard to the operator. The intensity of the flash at the slit lamp eyepiece was measured and the experimentally derived value wa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/9/009

    authors: Moseley H,Allan D

    更新日期:1987-09-01 00:00:00

  • UWB pulse propagation into human tissues.

    abstract::In this paper the propagation of a UWB pulse into a layered model of the human body is studied to characterize absorption and reflection of the UWB signal due to the different body tissues. Several time behaviours for the incident UWB pulse are considered and compared with reference to the feasibility of breath and he...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/24/8689

    authors: Cavagnaro M,Pittella E,Pisa S

    更新日期:2013-12-21 00:00:00

  • 4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior.

    abstract::A 4D ordered-subsets maximum a posteriori (OSMAP) algorithm for dynamic SPECT is described which uses a temporal prior that constrains each voxel's behaviour in time to conform to a compartmental model. No a priori limitations on kinetic parameters are applied; rather, the parameter estimates evolve as the algorithm i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/5/315

    authors: Kadrmas DJ,Gullberg GT

    更新日期:2001-05-01 00:00:00

  • Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging.

    abstract::Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/7/310

    authors: Zaidi H,Diaz-Gomez M,Boudraa A,Slosman DO

    更新日期:2002-04-07 00:00:00

  • Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms (MRCPs).

    abstract::Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advanta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcdb

    authors: Lee H,Yeom YS,Nguyen TT,Choi C,Han H,Shin B,Zhang X,Kim CH,Chung BS,Zankl M

    更新日期:2019-02-05 00:00:00

  • A Monte Carlo investigation of contaminant electrons due to a novel in vivo transmission detector.

    abstract::A novel transmission detector (IBA Dosimetry, Germany) developed as an IMRT quality assurance tool, intended for in vivo patient dose measurements, is studied here. The goal of this investigation is to use Monte Carlo techniques to characterize treatment beam parameters in the presence of the detector and to compare t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/4/020

    authors: Asuni G,Jensen JM,McCurdy BM

    更新日期:2011-02-21 00:00:00

  • Prospects for in vivo Raman spectroscopy.

    abstract::Raman spectroscopy is a potentially important clinical tool for real-time diagnosis of disease and in situ evaluation of living tissue. The purpose of this article is to review the biological and physical basis of Raman spectroscopy of tissue, to assess the current status of the field and to explore future directions....

    journal_title:Physics in medicine and biology

    pub_type: 传,历史文章,杂志文章,评审

    doi:10.1088/0031-9155/45/2/201

    authors: Hanlon EB,Manoharan R,Koo TW,Shafer KE,Motz JT,Fitzmaurice M,Kramer JR,Itzkan I,Dasari RR,Feld MS

    更新日期:2000-02-01 00:00:00

  • Characterization of cardiovascular liver motion for the eventual application of elasticity imaging to the liver in vivo.

    abstract::Elastography, which uses ultrasound to image the tissue strain that results from an applied displacement, can display tumours and heat-ablated tissue with high contrast. However, its application to liver in vivo may be problematic due to the presence of respiratory and cardiovascular sources of displacement. The aim o...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/49/18/001

    authors: Kolen AF,Miller NR,Ahmed EE,Bamber JC

    更新日期:2004-09-21 00:00:00

  • Influence of the SURLAS applicator on radiation dose distributions during simultaneous thermoradiotherapy with helical tomotherapy.

    abstract::Simultaneous thermoradiotherapy has been shown to maximize the effect of hyperthermia as a radiation sensitizer in cancer treatment. Here we follow our previous work on feasibility of thermoradiotherapy with the scanning ultrasound reflector linear array system (SURLAS) and TomoTherapy HiArt treatment system, and inve...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/10/004

    authors: Novák P,Peñagarícano JA,Nahirnyak V,Corry P,Moros EG

    更新日期:2008-05-21 00:00:00

  • 4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry.

    abstract::When dosimetric effects in time-dependent geometries are studied, usually either the results of individual three-dimensional (3D) calculations are combined or probability-based approaches are applied. These methods may become cumbersome and time-consuming if high time resolution is required or if the geometry is compl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/5/020

    authors: Paganetti H,Jiang H,Trofimov A

    更新日期:2005-03-07 00:00:00

  • A new column-generation-based algorithm for VMAT treatment plan optimization.

    abstract::We study the treatment plan optimization problem for volumetric modulated arc therapy (VMAT). We propose a new column-generation-based algorithm that takes into account bounds on the gantry speed and dose rate, as well as an upper bound on the rate of change of the gantry speed, in addition to MLC constraints. The alg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4569

    authors: Peng F,Jia X,Gu X,Epelman MA,Romeijn HE,Jiang SB

    更新日期:2012-07-21 00:00:00

  • Alanine dosimetry in strong magnetic fields: use as a transfer standard in MRI-guided radiotherapy.

    abstract::Reference dosimetry in the presence of a strong magnetic field is challenging. Ionisation chambers have shown to be strongly affected by magnetic fields. There is a need for robust and stable detectors in MRI-guided radiotherapy (MRIgRT). This study investigates the behaviour of the alanine dosimeter in magnetic field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8148

    authors: Billas I,Bouchard H,Oelfke U,Shipley D,Gouldstone C,Duane S

    更新日期:2020-06-03 00:00:00

  • Physics considerations in MV-CBCT multi-layer imager design.

    abstract::Megavoltage (MV) cone-beam computed tomography (CBCT) using an electronic portal imaging (EPID) offers advantageous features, including 3D mapping, treatment beam registration, high-z artifact suppression, and direct radiation dose calculation. Adoption has been slowed by image quality limitations and concerns about i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac8c6

    authors: Hu YH,Fueglistaller R,Myronakis M,Rottmann J,Wang A,Shedlock D,Morf D,Baturin P,Huber P,Star-Lack J,Berbeco R

    更新日期:2018-06-20 00:00:00

  • The ArcCHECK diode array for dosimetric verification of HybridArc.

    abstract::The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/021

    authors: Petoukhova AL,van Egmond J,Eenink MG,Wiggenraad RG,van Santvoort JP

    更新日期:2011-08-21 00:00:00

  • Experimental validation of Monte Carlo calculations with a voxelized Rando-Alderson phantom: a study on influence parameters.

    abstract::The development and improvement of techniques for an accurate dose assessment in medical physics is an important task. In this study, we focus on the validation of Monte Carlo calculations, by comparing organ doses assessed experimentally with thermoluminescent detectors in the Rando-Alderson phantom with doses calcul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/20/018

    authors: Struelens L,Vanhavere F,Smans K

    更新日期:2008-10-21 00:00:00

  • Pulsed EPR imaging: image reconstruction using selective acquisition sequences.

    abstract::Pulsed nuclear magnetic resonance imaging (NMRI) apparatus has developed very quickly. On the other hand, the development of apparatus for pulsed electron paramagnetic resonance imaging (EPRI) has been very slow. This fact is due to the extremely reduced relaxation times of the paramagnetic probes. EPR linewidths are ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/6/409

    authors: Di Giuseppe S,Placidi G,Brivati JA,Alecci M,Sotgiu A

    更新日期:1999-06-01 00:00:00

  • Developing a new case based computer-aided detection scheme and an adaptive cueing method to improve performance in detecting mammographic lesions.

    abstract::The purpose of this study is to evaluate a new method to improve performance of computer-aided detection (CAD) schemes of screening mammograms with two approaches. In the first approach, we developed a new case based CAD scheme using a set of optimally selected global mammographic density, texture, spiculation, and st...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5081

    authors: Tan M,Aghaei F,Wang Y,Zheng B

    更新日期:2017-01-21 00:00:00

  • A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field.

    abstract::Existing studies have suggested some debate on whether the quality of radiation that delivers dose outside of the primary field of a radiotherapy photon beam can be considered the same as that inside the primary field. We used a Monte Carlo approach to simulate the electron fluence differential in energy inside a wate...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/12/015

    authors: Kirkby C,Field C,MacKenzie M,Syme A,Fallone BG

    更新日期:2007-06-21 00:00:00

  • Influence of trace elements in human tissue in low-energy photon brachytherapy dosimetry.

    abstract::The aim of this paper is to determine the dosimetric impact of trace elements in human tissues for low-energy photon sources used in brachytherapy. Monte Carlo dose calculations were used to investigate the dosimetric effect of trace elements present in normal or cancerous human tissues. The effect of individual trace...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3585

    authors: White SA,Landry G,van Gils F,Verhaegen F,Reniers B

    更新日期:2012-06-07 00:00:00

  • Direct determination of cone-beam geometric parameters using the helical phantom.

    abstract::Estimation of a set of parameters that describe the geometry of the cone-beam computed tomography system plays an important role in the geometrical calibration. In the calibration process, the helical phantom consisting of spherical markers arranged on a helical trajectory has been widely applied. To directly determin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/19/5667

    authors: Xu M,Zhang C,Liu X,Li D

    更新日期:2014-10-07 00:00:00

  • Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation.

    abstract::A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI(vol) for an eigh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6309

    authors: Schlattl H,Zankl M,Becker J,Hoeschen C

    更新日期:2012-10-21 00:00:00

  • Dielectric properties of porcine glands, gonads and body fluids.

    abstract::Dielectric properties of porcine glandular tissues and gonads (in vivo) and body fluids (in vitro) have been obtained in the frequency range of 50 MHz to 20 GHz. The experimental data were fitted to a two term Cole-Cole expression. The data presented complement the available dielectric properties of tissues in the lit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/N339

    authors: Peyman A,Gabriel C

    更新日期:2012-10-07 00:00:00

  • Full-field speckle interferometry for non-contact photoacoustic tomography.

    abstract::A full-field speckle interferometry method for non-contact and prospectively high speed Photoacoustic Tomography is introduced and evaluated as proof of concept. Thermoelastic pressure induced changes of the objects topography are acquired in a repetitive mode without any physical contact to the object. In order to ob...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/4045

    authors: Horstmann J,Spahr H,Buj C,Münter M,Brinkmann R

    更新日期:2015-05-21 00:00:00

  • The quality of ionising radiations emitted by radionuclides incorporated into mammalian cells.

    abstract::Radionuclides which decay by electron capture accompanied by Auger electron cascades, or by beta emission are thought to be excessively damaging when incorporated into the molecular structure of mammalian cell nuclei and thereby pose a radiation hazard which is not assessable by conventional dosimetry. Survival data, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/7/003

    authors: Younis AR,Watt DE

    更新日期:1989-07-01 00:00:00

  • Proof-of-concept delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac.

    abstract::In this work we present the first delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac. The machine's current IMRT based control system was modified suitably to enable dynamic delivery of radiation, for the purpose of exploring MRI-guided radiation therapy adaptation modes in a research setti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abd66d

    authors: Kontaxis C,Woodhead PL,Bol GH,Lagendijk JJW,Raaymakers BW

    更新日期:2020-12-23 00:00:00

  • The effective attenuation coefficient of soft tissue in the presence of Compton scattering from bone: experiments on models.

    abstract::Calibration methods are investigated for the determination of bone density by the Compton scattering method. The scattered radiation from materials of different densities and dimensions is measured for this purpose. A function for the dependence of the intensity on these parameters is derived and compared with the exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/4/009

    authors: Leichter I,Weinreb A,Hazan G

    更新日期:1980-07-01 00:00:00

  • Quantification and normalization of x-ray mammograms.

    abstract::The analysis of (x-ray) mammograms remains qualitative, relying on the judgement of clinicians. We present a novel method to compute a quantitative, normalized measure of tissue radiodensity traversed by the primary beam incident on each pixel of a mammogram, a measure we term the standard attenuation rate (SAR). SAR ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6519

    authors: Tromans CE,Cocker MR,Brady SM

    更新日期:2012-10-21 00:00:00

  • Image reconstruction and scan configurations enabled by optimization-based algorithms in multispectral CT.

    abstract::Optimization-based algorithms for image reconstruction in multispectral (or photon-counting) computed tomography (MCT) remains a topic of active research. The challenge of optimization-based image reconstruction in MCT stems from the inherently non-linear data model that can lead to a non-convex optimization program f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a4b

    authors: Chen B,Zhang Z,Sidky EY,Xia D,Pan X

    更新日期:2017-11-02 00:00:00

  • A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3D PET.

    abstract::This paper presents a Fourier rebinning algorithm for three-dimensional image reconstruction in PET that incorporates the concept of spectral transfer function. It suggests the need for discarding low-frequency components in the rebinning. It also includes the correction for rebinning efficiency which was evaluated by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/4/004

    authors: Tanaka E,Amo Y

    更新日期:1998-04-01 00:00:00