Comparison of dosimetric standards of USA and France for HDR brachytherapy.

Abstract:

:A bilateral comparison of national dosimetric standards for high dose rate brachytherapy has been conducted between the Laboratoire National Henri Becquerel and the University of Wisconsin Accredited Dosimetry Calibration Laboratory. A complete overview of the methods that are currently in use to establish the two national standards is given. The comparison has been carried out using well-type transfer ionization chambers. Three units have been calibrated in both laboratories, and calibration coefficients have been compared. The discrepancies between the two measurements are within 0.3%.

journal_name

Phys Med Biol

authors

Douysset G,Gouriou J,Delaunay F,DeWerd L,Stump K,Micka J,Laboratoire National Henri Becquerel.,University of Wisconsin Accredited Dosimetry Calibration Laboratory.

doi

10.1088/0031-9155/50/9/003

subject

Has Abstract

pub_date

2005-05-07 00:00:00

pages

1961-78

issue

9

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(05)93805-0

journal_volume

50

pub_type

杂志文章,多中心研究
  • Evaluation of 209At as a theranostic isotope for 209At-radiopharmaceutical development using high-energy SPECT.

    abstract::The development of alpha-emitting radiopharmaceuticals using 211At requires quantitative determination of the time-dependent nature of the 211At biodistribution. However, imaging-based methods for acquiring this information with 211At have not found wide-spread use because of its low abundance of decay emissions suita...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaaa95

    authors: Crawford JR,Robertson AKH,Yang H,Rodríguez-Rodríguez C,Esquinas PL,Kunz P,Blinder S,Sossi V,Schaffer P,Ruth TJ

    更新日期:2018-02-21 00:00:00

  • Dosimetric accuracy of planning and delivering small proton therapy fields.

    abstract::A detailed Monte Carlo model of a proton therapy treatment head was commissioned to simulate the delivery of small field proton treatments. Small fields are challenging in the planning and quality assurance process because of aperture scattering and dosimetric disequilibrium. Four patients with small fields used in al...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/003

    authors: Bednarz B,Daartz J,Paganetti H

    更新日期:2010-12-21 00:00:00

  • CT reconstruction algorithm for a dental panoramic x-ray unit.

    abstract::A variable Jacobian and weighted backprojection algorithm, used for medical CT, was adapted to perform CT reconstructions on data obtained with a dental panoramic x-ray unit. A detector array, fitted to the unit for the purpose of acquiring digital panoramic radiographs, was used to collect the data. Compensations wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/12/001

    authors: Lee MD,Waggener RG,McDavid WD,Dove SB,Welander U,Tronje G

    更新日期:1992-12-01 00:00:00

  • Correlation between dosimetric effect and intrafraction motion during prostate treatments delivered with helical tomotherapy.

    abstract::The dosimetric impact of intrafraction prostate motion was investigated for helical tomotherapy treatments. Measured motion tracks were used to calculate the dosimetric impact on delivered target dose distributions. A dynamic dose calculation engine was developed to facilitate this evaluation. It was found that the D9...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/24/005

    authors: Langen KM,Lu W,Ngwa W,Willoughby TR,Chauhan B,Meeks SL,Kupelian PA,Olivera G

    更新日期:2008-12-21 00:00:00

  • Automatic bi-objective parameter tuning for inverse planning of high-dose-rate prostate brachytherapy.

    abstract::We present an automatic bi-objective parameter-tuning approach for inverse planning methods for high-dose-rate prostate brachytherapy, which aims to overcome the difficult and time-consuming manual parameter tuning that is currently required to obtain patient-specific high-quality treatment plans. We modelled treatmen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7362

    authors: Maree SC,Bosman PAN,van Wieringen N,Niatsetski Y,Pieters BR,Bel A,Alderliesten T

    更新日期:2020-04-02 00:00:00

  • Predicting voxel-level dose distributions for esophageal radiotherapy using densely connected network with dilated convolutions.

    abstract::This work aims to develop a voxel-level dose prediction framework by integrating distance information between PTV and OARs, as well as image information, into a densely-connected network (DCNN). Firstly, a four-channel feature map, consisting of a PTV image, an OAR image, a CT image, and a distance image, is construct...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba87b

    authors: Zhang J,Liu S,Yan H,Li T,Mao R,Liu J

    更新日期:2020-10-21 00:00:00

  • A comparison of 60 Hz uniform magnetic and electric induction in the human body.

    abstract::High-resolution computations of induced fields are used to assess equivalent source levels for human exposure to uniform low-frequency electric and magnetic fields. These results pertain to 60 Hz foot-to-head electric excitation of the body in three positions with respect to a ground plane, and to magnetic excitation ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/001

    authors: Dawson TW,Caputa K,Stuchly MA

    更新日期:1997-12-01 00:00:00

  • Dosimetric characterization of a new miniature multileaf collimator.

    abstract::The dosimetrical characteristics of a new miniature multileaf collimator (ModuLeaf MLC, MRC Systems GmbH, Heidelberg, Germany) attached to the accessory holder of a Siemens accelerator with 6 MV x-rays (PRIMUS, Siemens OCS, Concord, California, USA) have been investigated. In particular, those parameters which are imp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/12/402

    authors: Hartmann GH,Föhlisch F

    更新日期:2002-06-21 00:00:00

  • Accuracy of quantitative reconstructions in SPECT/CT imaging.

    abstract::The goal of this study was to determine the quantitative accuracy of our OSEM-APDI reconstruction method based on SPECT/CT imaging for Tc-99m, In-111, I-123, and I-131 isotopes. Phantom studies were performed on a SPECT/low-dose multislice CT system (Infinia-Hawkeye-4 slice, GE Healthcare) using clinical acquisition p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/17/009

    authors: Shcherbinin S,Celler A,Belhocine T,Vanderwerf R,Driedger A

    更新日期:2008-09-07 00:00:00

  • Developing a 'multiPatchPET' system in GATE for a PET system design with irregular geometries.

    abstract::This work modified the commonly used Monte Carlo tool package GATE by developing a new 'multiPatchPET' system so that GATE users can easily simulate PET systems with irregular geometries. The motivation was to design a brain PET scanner with high sensitivity. It is known that compact PET scanners with a large solid co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad8fd

    authors: Chen G,Weng F,Hong X,Tao W,Zhao Z,Peng Q,Huang Q

    更新日期:2018-09-06 00:00:00

  • An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery.

    abstract::Brain stereotactic radiosurgery (SRS) treatments require multiple quality assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear accelerator is crucial. In this study, a novel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8534

    authors: Capaldi DPI,Skinner LB,Dubrowski P,Yu AS

    更新日期:2020-06-10 00:00:00

  • Effect of fiducial marker localization on stereotactic target coordinate calculation in CT slices and radiographs.

    abstract::Novel methods are presented which allow the estimation of the effect of stereotactic fiducial marker localization on target localization in a stereotactic surgery planning program based on the integration of image data from various modalities. The results of simulations are presented. A method for the evaluation of th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/11/008

    authors: Lemieux L,Jagoe R

    更新日期:1994-11-01 00:00:00

  • Using surface markers for MRI guided breast conserving surgery: a feasibility survey.

    abstract::Breast MRI is frequently performed prior to breast conserving surgery in order to assess the location and extent of the lesion. Ideally, the surgeon should also be able to use the image information during surgery to guide the excision and this requires that the MR image is co-registered to conform to the patient's pos...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1589

    authors: Ebrahimi M,Siegler P,Modhafar A,Holloway CM,Plewes DB,Martel AL

    更新日期:2014-04-07 00:00:00

  • Is it necessary to plan with safety margins for actively scanned proton therapy?

    abstract::In radiation therapy, a plan is robust if the calculated and the delivered dose are in agreement, even in the case of different uncertainties. The current practice is to use safety margins, expanding the clinical target volume sufficiently enough to account for treatment uncertainties. This, however, might not be idea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/011

    authors: Albertini F,Hug EB,Lomax AJ

    更新日期:2011-07-21 00:00:00

  • Symmetries of the 2D magnetic particle imaging system matrix.

    abstract::In magnetic particle imaging (MPI), the relation between the particle distribution and the measurement signal can be described by a linear system of equations. For 1D imaging, it can be shown that the system matrix can be expressed as a product of a convolution matrix and a Chebyshev transformation matrix. For multidi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/4033

    authors: Weber A,Knopp T

    更新日期:2015-05-21 00:00:00

  • A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.

    abstract::Quantitative Yttrium-90 ((90)Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging has shown great potential to provide reliable estimates of (90)Y activity distribution for targeted radionuclide therapy dosimetry applications. One factor that potentially affects the reliability of the activity ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3711

    authors: Rong X,Du Y,Frey EC

    更新日期:2012-06-21 00:00:00

  • An adaptive technique for digital noise suppression in on-line portal imaging.

    abstract::Two complementary approaches to the noise suppression problem in on-line portal imaging have been analysed. Temporal filtering by image summation can substantially reduce the amount of noise in an image. In many cases, however, movements of the patient or the radiation source limit the time period over which the avera...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/3/011

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1990-03-01 00:00:00

  • Evaluation of the induced electric field and compliance procedure for a wireless power transfer system in an electrical vehicle.

    abstract::In this study, an induced electric field in a human body is evaluated for the magnetic field leaked from a wireless power transfer system for charging an electrical vehicle. The magnetic field from the wireless power transfer system is modelled computationally, and its effectiveness is confirmed by comparison with the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/21/7583

    authors: Laakso I,Hirata A

    更新日期:2013-11-07 00:00:00

  • Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: single-detector size and sampling step width.

    abstract::The spatial resolution of 2D detector arrays equipped with ionization chambers or diodes, used for the dose verification of IMRT treatment plans, is limited by the size of the single detector and the centre-to-centre distance between the detectors. Optimization criteria with regard to these parameters have been develo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/019

    authors: Poppe B,Djouguela A,Blechschmidt A,Willborn K,Rühmann A,Harder D

    更新日期:2007-05-21 00:00:00

  • Scattering kernels for fast neutron therapy treatment planning.

    abstract::The University of Washington (UW) Clinical Neutron Therapy System (CNTS) has been used to treat over 3300 patients. Treatment planning for these patients is currently performed using an MV x-ray model in Pinnacle® adapted to fit measurements of fast neutron output factors, wedge factors, depth-dose and lateral profile...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9a85

    authors: Moffitt GB,Wootton LS,Hårdemark B,Sandison GA,Laramore GE,Parvathaneni U,Stewart RD

    更新日期:2020-08-31 00:00:00

  • Introducing the Jacobian-volume-histogram of deforming organs: application to parotid shrinkage evaluation.

    abstract::The Jacobian of the deformation field of elastic registration between images taken during radiotherapy is a measure of inter-fraction local deformation. The histogram of the Jacobian values (Jac) within an organ was introduced (JVH-Jacobian-volume-histogram) and first applied in quantifying parotid shrinkage. MVCTs of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/11/008

    authors: Fiorino C,Maggiulli E,Broggi S,Liberini S,Cattaneo GM,Dell'oca I,Faggiano E,Di Muzio N,Calandrino R,Rizzo G

    更新日期:2011-06-07 00:00:00

  • 4D image reconstruction for emission tomography.

    abstract::An overview of the theory of 4D image reconstruction for emission tomography is given along with a review of the current state of the art, covering both positron emission tomography and single photon emission computed tomography (SPECT). By viewing 4D image reconstruction as a matter of either linear or non-linear par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/22/R371

    authors: Reader AJ,Verhaeghe J

    更新日期:2014-11-21 00:00:00

  • Effect on tumour control of time interval between surgery and postoperative radiotherapy: an empirical approach using Monte Carlo simulation.

    abstract::In this work, a procedure, based on Monte Carlo techniques, to analyse the effect on the tumour control probability of the time interval between surgery and postoperative radiotherapy is presented. The approach includes the tumour growth as well as the survival of tumour cells undergoing fractionated radiotherapy. Bot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/13/005

    authors: Al-Dweri FM,Guirado D,Lallena AM,Pedraza V

    更新日期:2004-07-07 00:00:00

  • On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution.

    abstract::The performance of a light sharing and recirculation mechanism that allows the extraction of depth of interaction (DOI) are investigated in this paper, with a particular focus on timing. In parallel, a method to optimize the coincidence time resolution (CTR) of PET detectors by use of the DOI information is proposed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2cb0

    authors: Pizzichemi M,Polesel A,Stringhini G,Gundacker S,Lecoq P,Tavernier S,Paganoni M,Auffray E

    更新日期:2019-08-07 00:00:00

  • Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.

    abstract::A method to measure the detector-to-object distance from the images obtained with stationary high-spatial-resolution gamma-ray cameras for in vivo studies has been developed. It exploits the shift of the imaged object in the image plane, obtained at a certain tilt of the parallel-hole collimator. A linear dependence o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/N04

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Bollini D,de Notaristefani F

    更新日期:2006-05-07 00:00:00

  • A determination by an analysis of X-ray attenuation in aluminium of the intesity distribution at its point of origin in a thick tungsten target of bremsstrahlung excited by constant potentials of 60-140 kV.

    abstract::A recently described, computer aided method of attenuation analysis has been applied to free-air chamber measurements of the attenuation by up to 30mm A1 of the exposure rate of a narrow beam of X-radiation excited at a thick W target in a Be window tube by constant potentials of 60, 80, 100, 120 and 140 kV. It has ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/2/001

    authors: Soole BW

    更新日期:1977-03-01 00:00:00

  • Segmented attenuation correction using artificial neural networks in positron tomography.

    abstract::The measured attenuation correction technique is widely used in cardiac positron tomographic studies. However, the success of this technique is limited because of insufficient counting statistics achievable in practical transmission scan times, and of the scattered radiation in transmission measurement which leads to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/10/024

    authors: Yu SK,Nahmias C

    更新日期:1996-10-01 00:00:00

  • Anatomically-aided PET reconstruction using the kernel method.

    abstract::This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporate...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6668

    authors: Hutchcroft W,Wang G,Chen KT,Catana C,Qi J

    更新日期:2016-09-21 00:00:00

  • A preclinical simulated dataset of S-values and investigation of the impact of rescaled organ masses using the MOBY phantom.

    abstract::Nuclear medicine and radiation therapy, although well established, are still rapidly evolving, by exploiting animal models, aiming to define precise dosimetry in molecular imaging protocols. The purpose of the present study was to create a dataset based on the MOBY phantom for the calculation of organ-to-organ S-value...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/6/2333

    authors: Kostou T,Papadimitroulas P,Loudos G,Kagadis GC

    更新日期:2016-03-21 00:00:00

  • Energy response of optically stimulated luminescent dosimeters for non-reference measurement locations in a 6 MV photon beam.

    abstract::Optically stimulated luminescent dosimeters (OSLDs) are becoming increasingly popular for measuring an absorbed dose in clinical radiotherapy. OSLDs have known energy dependence, and this is accounted for by either calibrating the OSLD with a specific nominal energy, or using a standard energy correction factor to acc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2505

    authors: Scarboro SB,Followill DS,Kerns JR,White RA,Kry SF

    更新日期:2012-05-07 00:00:00