A novel geometry-dosimetry label fusion method in multi-atlas segmentation for radiotherapy: a proof-of-concept study.

Abstract:

:Multi-atlas segmentation (MAS) has been widely used to automate the delineation of organs at risk (OARs) for radiotherapy. Label fusion is a crucial step in MAS to cope with the segmentation variabilities among multiple atlases. However, most existing label fusion methods do not consider the potential dosimetric impact of the segmentation result. In this proof-of-concept study, we propose a novel geometry-dosimetry label fusion method for MAS-based OAR auto-contouring, which evaluates the segmentation performance in terms of both geometric accuracy and the dosimetric impact of the segmentation accuracy on the resulting treatment plan. Differently from the original selective and iterative method for performance level estimation (SIMPLE), we evaluated and rejected the atlases based on both Dice similarity coefficient and the predicted error of the dosimetric endpoints. The dosimetric error was predicted using our previously developed geometry-dosimetry model. We tested our method in MAS-based rectum auto-contouring on 20 prostate cancer patients. The accuracy in the rectum sub-volume close to the planning tumor volume (PTV), which was found to be a dosimetric sensitive region of the rectum, was greatly improved. The mean absolute distance between the obtained contour and the physician-drawn contour in the rectum sub-volume 2 mm away from PTV was reduced from 3.96 mm to 3.36 mm on average for the 20 patients, with the maximum decrease found to be from 9.22 mm to 3.75 mm. We also compared the dosimetric endpoints predicted for the obtained contours with those predicted for the physician-drawn contours. Our method led to smaller dosimetric endpoint errors than the SIMPLE method in 15 patients, comparable errors in 2 patients, and slightly larger errors in 3 patients. These results indicated the efficacy of our method in terms of considering both geometric accuracy and dosimetric impact during label fusion. Our algorithm can be applied to different tumor sites and radiation treatments, given a specifically trained geometry-dosimetry model.

journal_name

Phys Med Biol

authors

Chang J,Tian Z,Lu W,Gu X,Chen M,Jiang SB

doi

10.1088/1361-6560/aa5ed9

subject

Has Abstract

pub_date

2017-05-07 00:00:00

pages

3656-3667

issue

9

eissn

0031-9155

issn

1361-6560

journal_volume

62

pub_type

杂志文章
  • Relative determination of W-values for alpha particles in tissue-equivalent and other gases.

    abstract::W (the average energy to form an ion pair) for 5.4 MeV 241Am alpha particles in a Rossi-type tissue-equivalent (TE) gas, argon and methane was determined to an accuracy better than 0.2% using a new automated data handling system. A vibrating reed electrometer and current digitiser were used to measure the current prod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/005

    authors: Krieger GL,Baum JW,Varma MN,Beach JL

    更新日期:1979-03-01 00:00:00

  • Optimization of magnetic flux density measurement using multiple RF receiver coils and multi-echo in MREIT.

    abstract::Magnetic Resonance Electrical Impedance Tomography (MREIT) is an MRI method that enables mapping of internal conductivity and/or current density via measurements of magnetic flux density signals. The MREIT measures only the z-component of the induced magnetic flux density B = (Bx, By, Bz) by external current injection...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4827

    authors: Jeong WC,Chauhan M,Sajib SZ,Kim HJ,Serša I,Kwon OI,Woo EJ

    更新日期:2014-09-07 00:00:00

  • Computational fluid dynamics modelling of perfusion measurements in dynamic contrast-enhanced computed tomography: development, validation and clinical applications.

    abstract::Dynamic contrast-enhanced computed tomography (DCE-CT) is an imaging tool that aids in evaluating functional characteristics of tissue at different stages of disease management: diagnostic, radiation treatment planning, treatment effectiveness, and monitoring. Clinical validation of DCE-derived perfusion parameters re...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/6111

    authors: Peladeau-Pigeon M,Coolens C

    更新日期:2013-09-07 00:00:00

  • Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.

    abstract::Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/012

    authors: Torres-Espallardo I,Rafecas M,Spanoudaki V,McElroy DP,Ziegler SI

    更新日期:2008-05-07 00:00:00

  • The distribution of trace elements Ca, Fe, Cu and Zn and the determination of copper oxidation state in breast tumour tissue using muSRXRF and muXANES.

    abstract::A micro beam synchrotron x-ray fluorescence (muSRXRF) technique has been used to determine the localization of metals in primary invasive ductal carcinoma of breast. Nine samples were examined, all of which were formalin fixed tissues arranged as micro arrays of 1.0 mm diameter and 10 microm thickness. Cu was the part...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/11/018

    authors: Farquharson MJ,Al-Ebraheem A,Falkenberg G,Leek R,Harris AL,Bradley DA

    更新日期:2008-06-07 00:00:00

  • A double-tuned (1)H/(23)Na dual resonator system for tissue sodium concentration measurements in the rat brain via Na-MRI.

    abstract::A method for quantifying the tissue sodium concentration (TSC) in the rat brain from ²³Na-MR images was developed. TSC is known to change in a variety of common human diseases and holds considerable potential to contribute to their study; however, its accurate measurement in small laboratory animals has been hindered ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/019

    authors: Wetterling F,Tabbert M,Junge S,Gallagher L,Macrae IM,Fagan AJ

    更新日期:2010-12-21 00:00:00

  • On the correction, perturbation and modification of small field detectors in relative dosimetry.

    abstract::The purpose of this study was to derive a complete set of correction and perturbation factors for output factors (OF) and dose profiles. Modern small field detectors were investigated including a plastic scintillator (Exradin W1, SI), a liquid ionization chamber (microLion 31018, PTW), an unshielded diode (Exradin D1V...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/19/5937

    authors: Papaconstadopoulos P,Tessier F,Seuntjens J

    更新日期:2014-10-07 00:00:00

  • Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems.

    abstract::Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa307

    authors: Wood TJ,Moore CS,Saunderson JR,Beavis AW

    更新日期:2018-01-16 00:00:00

  • A comprehensive study of the use of temporal moments in time-resolved diffuse optical tomography: part I. Theoretical material.

    abstract::The problem of fluorescence diffuse optical tomography consists in localizing fluorescent markers from near-infrared light measurements. Among the different available acquisition modalities, the time-resolved modality is expected to provide measurements of richer information content. To extract this information, the m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/23/004

    authors: Ducros N,Hervé L,Da Silva A,Dinten JM,Peyrin F

    更新日期:2009-12-07 00:00:00

  • Optimization of attenuation correction for positron emission tomography studies of thorax and pelvis using count-based transmission scans.

    abstract::The quality of thorax and pelvis transmission scans and therefore of attenuation correction in PET depends on patient thickness and transmission rod source strength. The purpose of the present study was to assess the feasibility of using count-based transmission scans, thereby guaranteeing more consistent image qualit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/4/n01

    authors: Boellaard R,van Lingen A,van Balen SC,Lammertsma AA

    更新日期:2004-02-21 00:00:00

  • The fast Padé transform in magnetic resonance spectroscopy for potential improvements in early cancer diagnostics.

    abstract::The convergence rates of the fast Padé transform (FPT) and the fast Fourier transform (FFT) are compared. These two estimators are used to process a time-signal encoded at 4 T by means of one-dimensional magnetic resonance spectroscopy (MRS) for healthy human brain. It is found systematically that at any level of trun...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/18/010

    authors: Belkić D,Belkić K

    更新日期:2005-09-21 00:00:00

  • Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine.

    abstract::In this paper we present the results of a dosimetric evaluation of a 2D ionization chamber array with the objective of its implementation for quality assurance in clinical routine. The pixel ionization chamber MatriXX (Scanditronix Wellhofer, Germany) consists of 32x32 chambers with a distance of 7.6 mm between chambe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/4/023

    authors: Herzen J,Todorovic M,Cremers F,Platz V,Albers D,Bartels A,Schmidt R

    更新日期:2007-02-21 00:00:00

  • A new method to reconstruct intra-fractional prostate motion in volumetric modulated arc therapy.

    abstract::Intra-fractional motion is a concern during prostate radiation therapy, as it may cause deviations between planned and delivered radiation doses. Because accurate motion information during treatment delivery is critical to address dose deviation, we developed the projection marker matching method (PM3), a novel method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e37

    authors: Chi Y,Rezaeian NH,Shen C,Zhou Y,Lu W,Yang M,Hannan R,Jia X

    更新日期:2017-07-07 00:00:00

  • Real-time motion-adaptive-optimization (MAO) in TomoTherapy.

    abstract::IMRT delivery follows a planned leaf sequence, which is optimized before treatment delivery. However, it is hard to model real-time variations, such as respiration, in the planning procedure. In this paper, we propose a negative feedback system of IMRT delivery that incorporates real-time optimization to account for i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/14/003

    authors: Lu W,Chen M,Ruchala KJ,Chen Q,Langen KM,Kupelian PA,Olivera GH

    更新日期:2009-07-21 00:00:00

  • Ionization chamber volume determination and quality assurance using micro-CT imaging.

    abstract::Ion chamber dosimetry requires a high degree of precision, at all steps within the dosimetric process, in order to ensure accurate dose measurements. This work presents a novel technique for ion chamber volume determination and quality assurance, using micro-computed tomography (micro-CT). Four nominally identical Exr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/012

    authors: McNiven AL,Umoh J,Kron T,Holdsworth DW,Battista JJ

    更新日期:2008-09-21 00:00:00

  • Radiofrequency and microwave dielectric properties of aqueous cryoprotectant agents: dimethyl sulphoxide and 2,3-butanediol.

    abstract::Earlier work on the dielectric properties of cryoprotectant agents is extended using a modified measuring cell and method of data reduction yielding results more efficiently over a temperature range from -75 to +25 degrees C at frequencies from 27 MHz to 3 GHz. Dimethyl sulphoxide and butanediol are investigated at lo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/10/011

    authors: Evans S,bin Azeman A

    更新日期:1998-10-01 00:00:00

  • Reply to Comment: 'A novel method for fast and robust estimation of fluorescence decay dynamics using constrained least-square deconvolution with Laguerre expansion'.

    abstract::In this response we underscore that the instrumentation described in the original publication (Liu et al 2012 Phys. Med. Biol. 57 843-65) was based on pulse-sampling technique, while the comment by Zhang et al is based on the assumption that a time-correlated single photon counting (TCSPC) instrumentation was used. Th...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章

    doi:10.1088/1361-6560/aa5231

    authors: Ma D,Liu J,Qi J,Marcu L

    更新日期:2017-02-21 00:00:00

  • Evaluation of a commercial radiochromatography module as an arterial blood activity monitor.

    abstract::Input functions required for positron emission tomography (PET) tracer kinetic modeling are often obtained from arterial blood. In some situations, using short-lived radiotracers, e.g. [(15)O]water, rapid sample handling is required. A method used at several facilities is to pump blood through a detector system at a c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/2/003

    authors: Laymon CM,Sashin D,Carney JP,Ruszkiewicz J,Altenburger D,Becker CR,Lopresti BJ,Mason NS,Mountz JM,Price JC,Schavey R,Mathis CA

    更新日期:2008-01-21 00:00:00

  • An analytical reconstruction model of the spread-out Bragg peak using laser-accelerated proton beams.

    abstract::With the development of laser technology, laser-driven proton acceleration provides a new method for proton tumor therapy. However, it has not been applied in practice because of the wide and decreasing energy spectrum of laser-accelerated proton beams. In this paper, we propose an analytical model to reconstruct the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6fce

    authors: Tao L,Zhu K,Zhu J,Xu X,Lin C,Ma W,Lu H,Zhao Y,Lu Y,Chen JE,Yan X

    更新日期:2017-07-07 00:00:00

  • The impact of calibration phantom errors on dual-energy digital mammography.

    abstract::Microcalcification is one of the earliest and main indicators of breast cancer. Because dual-energy digital mammography could suppress the contrast between the adipose and glandular tissues of the breast, it is considered a promising technique that will improve the detection of microcalcification. In dual-energy digit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/004

    authors: Mou X,Chen X,Sun L,Yu H,Ji Z,Zhang L

    更新日期:2008-11-21 00:00:00

  • Calculation of water equivalent ratios for various materials at proton energies ranging 10-500 MeV using MCNP, FLUKA, and GEANT4 Monte Carlo codes.

    abstract::Dosimetry of proton beams is generally evaluated in liquid water, or alternatively in solid phantoms via water equivalent ratios (WER). WER is defined as the ratio of proton range in liquid water to that in a phantom of certain material. Presently, WER is not available in the literature neither for a wide range of ene...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad0bd

    authors: Safigholi H,Song WY

    更新日期:2018-07-27 00:00:00

  • High-resolution fluence verification for treatment plan specific QA in ion beam radiotherapy.

    abstract::Ion beam radiotherapy exploits the finite range of ion beams and the increased dose deposition of ions toward the end of their range in material. This results in high dose conformation to the target region, which can be further increased using scanning ion beams. The standard method for patient-plan verification in io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/6/1725

    authors: Martišíková M,Brons S,Hesse BM,Jäkel O

    更新日期:2013-03-21 00:00:00

  • The IPEM code of practice for determination of the reference air kerma rate for HDR (192)Ir brachytherapy sources based on the NPL air kerma standard.

    abstract::This paper contains the recommendations of the high dose rate (HDR) brachytherapy working party of the UK Institute of Physics and Engineering in Medicine (IPEM). The recommendations consist of a Code of Practice (COP) for the UK for measuring the reference air kerma rate (RAKR) of HDR (192)Ir brachytherapy sources. I...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/11/011

    authors: Bidmead AM,Sander T,Locks SM,Lee CD,Aird EG,Nutbrown RF,Flynn A,IPEM Working Party.

    更新日期:2010-06-07 00:00:00

  • The modelling of biological systems in three dimensions using the time domain finite-difference method: I. The implementation of the model.

    abstract::A computer method has been developed which uses the time domain finite-difference (TDFD) algorithm to calculate the deposition of the electromagnetic (EM) field in three-dimensional biological models. This, the first of two papers, describes the algorithm and the computer programs developed. The method is demonstrated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/11/006

    authors: Lau RW,Sheppard RJ

    更新日期:1986-11-01 00:00:00

  • Optimizing wavelength choice for quantitative optoacoustic imaging using the Cramer-Rao lower bound.

    abstract::Several papers have recently addressed the issue of estimating chromophore concentration in optoacoustic imaging (OAI) using multiple wavelengths. The choice of wavelengths obviously affects the accuracy and precision of the estimates. One might assume that the wavelengths that maximize the extinction coefficients of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/23/004

    authors: Modgil D,La Riviére PJ

    更新日期:2010-12-07 00:00:00

  • Depth of ionization chamber in water.

    abstract::The device developed by the authors and described here enables the user to measure the depth from the water surface to the point of measurement for a cylindrical ion chamber with a waterproof plastic cap in a water phantom, free of surface-tension error with a high precision. The device seeks vertical orientation and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/8/007

    authors: Tailor RC,Tello VM

    更新日期:1995-08-01 00:00:00

  • A method to reconstruct intra-fractional liver motion in rotational radiotherapy using linear fiducial markers.

    abstract::Complex intra-fractional motion and deformation of the liver significantly impacts the accuracy of delivered dose in radiotherapy. It limits margin reduction, dose escalation and normal tissue sparing. A critical component of motion management is to accurately reconstruct tumor motion. In this study, we developed a si...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4c0d

    authors: Chi Y,Shen C,Li B,Zhang Y,Yang M,Folkert M,Jia X

    更新日期:2019-11-21 00:00:00

  • Development and evaluation of a deep learning based artificial intelligence for automatic identification of gold fiducial markers in an MRI-only prostate radiotherapy workflow.

    abstract::Identification of prostate gold fiducial markers in magnetic resonance imaging (MRI) images is challenging when CT images are not available, due to misclassifications from intra-prostatic calcifications. It is also a time consuming task and automated identification methods have been suggested as an improvement for bot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb0f9

    authors: Gustafsson CJ,Swärd J,Adalbjörnsson SI,Jakobsson A,Olsson LE

    更新日期:2020-11-12 00:00:00

  • Comparison of a finite-element multigroup discrete-ordinates code with Monte Carlo for radiotherapy calculations.

    abstract::Radiotherapy calculations often involve complex geometries such as interfaces between materials of vastly differing atomic number, such as lung, bone and/or air interfaces. Monte Carlo methods have been used to calculate accurately the perturbation effects of the interfaces. However, these methods can be computational...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/010

    authors: Gifford KA,Horton JL,Wareing TA,Failla G,Mourtada F

    更新日期:2006-05-07 00:00:00

  • Modelling pencil-beam divergence with the electron pencil-beam redefinition algorithm.

    abstract::The electron pencil-beam redefinition algorithm (PBRA), which is used to calculate electron beam dose distributions, assumes that the virtual source of each pencil beam is identical to that of the broad beam incident on the patient. In the present work, a virtual source specific for each pencil beam is modelled by inc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/11/306

    authors: Boyd RA,Hogstrom KR,White RA,Starkschall G

    更新日期:2001-11-01 00:00:00