Automated detection of clustered microcalcifications on mammograms: CAD system application to MIAS database.

Abstract:

:To investigate the detection performance of our automated detection scheme for clustered microcalcifications on mammograms, we applied our computer-aided diagnosis (CAD) system to the database of the Mammographic Image Analysis Society (MIAS) in the UK. Forty-three mammograms from this database were used in this study. In our scheme, the breast regions were firstly extracted by determining the skinline. Histograms of the original images were used to extract the high-density area within the breast region as the segmentation from the fatty area around the skinline. Then the contrast correction technique was employed. Gradient vectors of the image density were calculated on the contrast corrected images. To extract the specific features of the pattern of the microcalcifications, triple-ring filter analysis was employed. A variable-ring filter was used for more accurate detection after the triple-ring filter. The features of the detected candidate areas were then characterized by feature analysis. The areas which satisfied the characteristics and specific terms were classified and displayed as clusters. As a result, the sensitivity was 95.8% with the false-positive rate at 1.8 clusters per image. This demonstrates that the automated detection of clustered microcalcifications in our CAD system is reliable as an aid to radiologists.

journal_name

Phys Med Biol

authors

Ibrahim N,Fujita H,Hara T,Endo T

doi

10.1088/0031-9155/42/12/021

subject

Has Abstract

pub_date

1997-12-01 00:00:00

pages

2577-89

issue

12

eissn

0031-9155

issn

1361-6560

journal_volume

42

pub_type

杂志文章
  • Effect of microscopic modeling of skin in electrical and thermal analysis of transcranial direct current stimulation.

    abstract::Transcranial direct current stimulation (tDCS) is a neuromodulation scheme where a small current is delivered to the brain via two electrodes attached to the scalp. The electrode design is an important topic, not only as regards efficacy, but also from a safety perspective, as tDCS may be related to skin lesions that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8825

    authors: Gomez-Tames J,Sugiyama Y,Laakso I,Tanaka S,Koyama S,Sadato N,Hirata A

    更新日期:2016-12-21 00:00:00

  • PDT dose dosimetry for Photofrin-mediated pleural photodynamic therapy (pPDT).

    abstract::Photosensitizer fluorescence excited by photodynamic therapy (PDT) treatment light can be used to monitor the in vivo concentration of the photosensitizer and its photobleaching. The temporal integral of the product of in vivo photosensitizer concentration and light fluence is called PDT dose, which is an important do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9874

    authors: Ong YH,Kim MM,Finlay JC,Dimofte A,Singhal S,Glatstein E,Cengel KA,Zhu TC

    更新日期:2017-12-29 00:00:00

  • The use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics.

    abstract::Monte Carlo (MC) simulations are often at the heart of the testing procedure in biomedical optics. One of the critical points in MC simulations is to define the new photon direction after each scattering event. One of the most popular solutions is to use the Henyey-Greenstein phase function or some linear combinations...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/17/N04

    authors: Binzoni T,Leung TS,Gandjbakhche AH,Rüfenacht D,Delpy DT

    更新日期:2006-09-07 00:00:00

  • The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp.

    abstract::In recent years there has been a large amount of research into the potential use of radiation sensitive gels for three-dimensional verification of clinical radiotherapy doses. In this paper we report the use of a MAGIC gel dosimeter (Fong et al 2001 Phys. Med. Biol. 46 3105) for the verification of a specific patient'...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/9/003

    authors: Trapp JV,Partridge M,Hansen VN,Childs P,Bedford J,Warrington AP,Leach MO,Webb S

    更新日期:2004-05-07 00:00:00

  • THz time domain spectroscopy of biomolecular conformational modes.

    abstract::We discuss the use of terahertz time domain spectroscopy for studies of conformational flexibility and conformational change in biomolecules. Protein structural dynamics are vital to biological function with protein flexibility affecting enzymatic reaction rates and sensory transduction cycling times. Conformational m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/21/318

    authors: Markelz A,Whitmire S,Hillebrecht J,Birge R

    更新日期:2002-11-07 00:00:00

  • Laser shaping of corneal transplants in vitro: area ablation with small overlapping laser spots produced by a pulsed scanning laser beam using an optimizing ablation algorithm.

    abstract::Area laser lathing and trephination of donor corneas is used to produce different types of grafts for human transplantation. 193 nm (ArF excimer) laser radiation is used, since this is known to give a non-thermal laser-tissue interaction with a minimal zone of tissue damage. To guarantee the highest degree of flexibil...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/5/005

    authors: Homolka P,Biowski R,Kaminski S,Barisani T,Husinsky W,Bergmann H,Grabner G

    更新日期:1999-05-01 00:00:00

  • Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system.

    abstract::The purpose of this work was to use Monte Carlo simulations to verify the accuracy of the dose distributions from a commercial treatment planning optimization system (Corvus, Nomos Corp., Sewickley, PA) for intensity-modulated radiotherapy (IMRT). A Monte Carlo treatment planning system has been implemented clinically...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/9/303

    authors: Ma CM,Pawlicki T,Jiang SB,Li JS,Deng J,Mok E,Kapur A,Xing L,Ma L,Boyer AL

    更新日期:2000-09-01 00:00:00

  • An iodine-125 thyroid measurement method.

    abstract::A two-probe technique has been developed to measure 125I in the thyroid. In this technique simultaneous emissions from a source are detected as coincidence events between two probes rather than as a sum peak in a single probe (the sum peak method). The background count rate when counting coincidence events between pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/3/004

    authors: Burns PA,Peggie JR

    更新日期:1980-05-01 00:00:00

  • Kernel-based curve-fitting method with spatial regularization for generation of parametric images in dynamic PET.

    abstract::Due to high levels of noise in pixel-wise time-activity curves, the indirect method that generates kinetic parametric images from dynamic positron emission tomography (PET) images often results in poor parametric image quality. We have demonstrated that the quality of parametric images can be improved by denoising dyn...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb1d8

    authors: Huang HM

    更新日期:2020-11-17 00:00:00

  • Image reconstruction.

    abstract::We give an overview of the role of Physics in Medicine and Biology in the development of tomographic reconstruction algorithms. We focus on imaging modalities involving ionizing radiation, CT, PET and SPECT, and cover a wide spectrum of reconstruction problems, starting with classical 2D tomography in the 1970s up to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R09

    authors: Defrise M,Gullberg GT

    更新日期:2006-07-07 00:00:00

  • Computed LET distributions in the build-up region of tissue for 14 MeV neutrons.

    abstract::Experimental radiobiological investigations of fast neutron beams involve irradiation of thin cell layers. The irradiation of cells is done either in free air or with a material such as graphite, TE plastic or bone-equivalent plastic covering the cells. This paper discusses the computed dose distributions in LET at sh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/5/007

    authors: Bhatia DP,Nagarajan PS

    更新日期:1979-09-01 00:00:00

  • Anatomically-aided PET reconstruction using the kernel method.

    abstract::This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporate...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6668

    authors: Hutchcroft W,Wang G,Chen KT,Catana C,Qi J

    更新日期:2016-09-21 00:00:00

  • A point kernel algorithm for microbeam radiation therapy.

    abstract::Microbeam radiation therapy (MRT) is a treatment approach in radiation therapy where the treatment field is spatially fractionated into arrays of a few tens of micrometre wide planar beams of unusually high peak doses separated by low dose regions of several hundred micrometre width. In preclinical studies, this treat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8d63

    authors: Debus C,Oelfke U,Bartzsch S

    更新日期:2017-10-19 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • A validated Geant4 model of a whole-body PET scanner with four-layer DOI detectors.

    abstract::The purpose of this work is to develop a validated Geant4 simulation model of a whole-body prototype PET scanner constructed from the four-layer depth-of-interaction detectors developed at the National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Japan. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa24

    authors: Ahmed AM,Chacon A,Rutherford H,Akamatsu G,Mohammadi A,Nishikido F,Tashima H,Yoshida E,Yamaya T,Franklin DR,Rosenfeld A,Guatelli S,Safavi-Naeini M

    更新日期:2020-12-18 00:00:00

  • Comparison of in vivo scintillation probes and gamma cameras for detection of small, deep tumours.

    abstract::An in vivo probe was compared with a gamma camera for the task of detecting radiolabelled tumour models in a water phantom. The probe, which contained a 1 cm diameter NaI(T1) detector, was designed and used by us for surgical staging studies of gynaecological patients. Tumours were spherical sources of different sizes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/6/008

    authors: Barber HB,Barrett HH,Woolfenden JM,Myers KJ,Hickernell TS

    更新日期:1989-06-01 00:00:00

  • Markerless positional verification using template matching and triangulation of kV images acquired during irradiation for lung tumors treated in breath-hold.

    abstract::Lung tumors treated in breath-hold are subject to inter- and intra-breath-hold variations, which makes tumor position monitoring during each breath-hold important. A markerless technique is desirable, but limited tumor visibility on kV images makes this challenging. We evaluated if template matching  +  triangulation ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac1a9

    authors: Hazelaar C,Dahele M,Mostafavi H,van der Weide L,Slotman B,Verbakel W

    更新日期:2018-05-29 00:00:00

  • Self-adaptive ultrasonic beam amplifiers: application to transcostal shock wave therapy.

    abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9b5

    authors: Robin J,Simon A,Arnal B,Tanter M,Pernot M

    更新日期:2018-09-06 00:00:00

  • Preliminary evaluation of biomechanical modeling of lung deflation during minimally invasive surgery using pneumothorax computed tomography scans.

    abstract::During minimally invasive surgery (MIS) for lung tumor resection, the localization of tumors or nodules relies on visual inspection of the deflated lung on intra-procedural video. For patients with tumors or nodules located deeper in the lung, this localization is not possible without prior invasive marking techniques...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb6ba

    authors: Lesage AJ,Rajaram R,Tam AL,Rigaud BS,Brock KK,Rice DC,Cazoulat G

    更新日期:2020-09-09 00:00:00

  • Bulk optical properties of healthy female breast tissue.

    abstract::We have measured the bulk optical properties of healthy female breast tissues in vivo in the parallel plate, transmission geometry. Fifty-two volunteers were measured. Blood volume and blood oxygen saturation were derived from the optical property data using a novel method that employed a priori spectral information t...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/47/16/302

    authors: Durduran T,Choe R,Culver JP,Zubkov L,Holboke MJ,Giammarco J,Chance B,Yodh AG

    更新日期:2002-08-21 00:00:00

  • On the importance of body posture and skin modelling with respect to in situ electric field strengths in magnetic field exposure scenarios.

    abstract::The reference levels and maximum permissible exposure values for magnetic fields that are currently used have been derived from basic restrictions under the assumption of upright standing body models in a standard posture, i.e. with arms laterally down and without contact with metallic objects. Moreover, if anatomical...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4412

    authors: Schmid G,Hirtl R

    更新日期:2016-06-21 00:00:00

  • A theoretical model for respiratory motion artifacts in free-breathing CT scans.

    abstract::Successful radiotherapy treatment depends heavily upon the accuracy of patient geometry captured during treatment simulation using computed tomography (CT) scans. Radiotherapy patients are often scanned under free breathing, and respiratory motion can cause severe artifacts in CT scans, including shortening, elongatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/3/018

    authors: Lewis JH,Jiang SB

    更新日期:2009-02-07 00:00:00

  • Performance of a multi-axis ionization chamber array in a 1.5 T magnetic field.

    abstract::At the UMC Utrecht a prototype MR-linac has been installed. The system consists of an 8 MV Elekta linear accelerator and a 1.5 T Philips MRI system. This paper investigates the performance of the IC PROFILER™, a multi-axis ionization chamber array, in a 1.5 T magnetic field. The influence of the magnetic field on the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1845

    authors: Smit K,Kok JG,Lagendijk JJ,Raaymakers BW

    更新日期:2014-04-07 00:00:00

  • Variability among polysulphone calibration curves.

    abstract::Within an epidemiological study regarding the correlation between skin pathologies and personal ultraviolet (UV) exposure due to solar radiation, 14 field campaigns using polysulphone (PS) dosemeters were carried out at three different Italian sites (urban, semi-rural and rural) in every season of the year. A polysulp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/17/019

    authors: Casale GR,Borra M,Colosimo A,Colucci M,Militello A,Siani AM,Sisto R

    更新日期:2006-09-07 00:00:00

  • A comprehensive study of the use of temporal moments in time-resolved diffuse optical tomography: part I. Theoretical material.

    abstract::The problem of fluorescence diffuse optical tomography consists in localizing fluorescent markers from near-infrared light measurements. Among the different available acquisition modalities, the time-resolved modality is expected to provide measurements of richer information content. To extract this information, the m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/23/004

    authors: Ducros N,Hervé L,Da Silva A,Dinten JM,Peyrin F

    更新日期:2009-12-07 00:00:00

  • Comparison of risk of radiogenic second cancer following photon and proton craniospinal irradiation for a pediatric medulloblastoma patient.

    abstract::Pediatric patients who received radiation therapy are at risk of developing side effects such as radiogenic second cancer. We compared proton and photon therapies in terms of the predicted risk of second cancers for a 4 year old medulloblastoma patient receiving craniospinal irradiation (CSI). Two CSI treatment plans ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/807

    authors: Zhang R,Howell RM,Giebeler A,Taddei PJ,Mahajan A,Newhauser WD

    更新日期:2013-02-21 00:00:00

  • An in silico framework to analyze the anisotropic shear wave mechanics in cardiac shear wave elastography.

    abstract::Shear wave elastography (SWE) is a potential tool to non-invasively assess cardiac muscle stiffness. This study focused on the effect of the orthotropic material properties and mechanical loading on the performance of cardiac SWE, as it is known that these factors contribute to complex 3D anisotropic shear wave propag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaaffe

    authors: Caenen A,Pernot M,Peirlinck M,Mertens L,Swillens A,Segers P

    更新日期:2018-03-23 00:00:00

  • A quantitative assessment of the depth sensitivity of an optical topography system using a solid dynamic tissue-phantom.

    abstract::A solid dynamic phantom with tissue-like optical properties is presented, which contains seven discrete targets impregnated with thermochromic pigment located at different depths from the surface. Changes in absorption are obtained in response to localized heating of the targets, simulating haemodynamic changes occurr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/20/016

    authors: Correia T,Banga A,Everdell NL,Gibson AP,Hebden JC

    更新日期:2009-10-21 00:00:00

  • An automated method for adaptive radiation therapy for prostate cancer patients using continuous fiducial-based tracking.

    abstract::Electromagnetic tracking technology is primarily used for continuous prostate localization during radiotherapy, but offers potential value for evaluation of dosimetric coverage and adequacy of treatment for dynamic targets. We developed a highly automated method for daily computation of cumulative dosimetric effects o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/005

    authors: Noel CE,Santanam L,Olsen JR,Baker KW,Parikh PJ

    更新日期:2010-01-07 00:00:00

  • Temperature simulations in tissue with a realistic computer generated vessel network.

    abstract::The practical use of a discrete vessel thermal model for hyperthermia treatment planning requires a number of choices with respect to the unknown part of the patient's vasculature. This work presents a study of the thermal effects of blood flow in a simple tissue geometry with a detailed artificial vessel network. The...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/4/317

    authors: Van Leeuwen GM,Kotte AN,Raaymakers BW,Lagendijk JJ

    更新日期:2000-04-01 00:00:00