Abstract:
:The accurate determination of mean ionization potential (I m) has the potential to reduce range uncertainty based margins and therefore allow for more focal treatments in proton radiotherapy. Many methods have been proposed to reduce uncertainty in I m and stopping power ratios (SPR), each with varying degrees of accuracy and issues. In this work, we present a simple parameterized model to determine I m in human biological tissue, allowing for the computation of patient-specific I m at the voxel level using magnetic resonance imaging (MRI). The model requires the measurement of three parameters by MRI, with only two parameters, mass percent water content and mass percent hydrogen content in organic molecules, required for the special case of soft tissues. The accuracy of this I m determination method was evaluated in available 'standard' (ICRU Report #44, (ICRU 1989 Tissue Substitutes in Radiation Dosimetry and Measurement (Bethesda, MD: International Commission on Radiation Units and Measurements))) human tissues. The sensitivity of this I m determination method to in vivo perturbations was also tested by calculating the effect of 10% variations in the experimentally measurable parameters on I m and SPR. For the human tissues modeled in this work, a high level of accuracy with low susceptibility to perturbations in measurement error was achieved in the prediction of I m. Root-mean-square errors in I m were within 0.77% and 1.8% for both soft and bony tissues, and were 0.09% and 0.2% for the SPR of soft and bony tissues, respectively, assuming knowledge of electron density. Proof of principle MR measurements and model-based computations of I m and SPR were taken in phantom for a series of hydrogenous solutions and compared against expected I m and SPR calculations from known elemental composition. MR determined I m and SPR values in a known composition solution were determined to within 5% and 0.52%, respectively. We present a novel model to accurately calculate mean ionization potential from measurements acquirable by MRI and show its feasibility in a phantom.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Sudhyadhom Adoi
10.1088/1361-6560/aa8d9esubject
Has Abstractpub_date
2017-10-27 00:00:00pages
8521-8535issue
22eissn
0031-9155issn
1361-6560journal_volume
62pub_type
杂志文章abstract::We propose a completely automated algorithm for the detection of the spinal centreline and the centres of vertebral bodies and intervertebral discs in images acquired by computed tomography (CT) and magnetic resonance (MR) imaging. The developed methods are based on the analysis of the geometry of spinal structures an...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/1/015
更新日期:2010-01-07 00:00:00
abstract::The origin of photons emitted in optical fibres under proton irradiation has been attributed to either entirely Čerenkov radiation or light consisting of fluorescence with a substantial amount of Čerenkov radiation. The source of the light emission is assessed in order to understand why the signal from optical fibres ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaafad
更新日期:2018-03-09 00:00:00
abstract::Determination of the cardiorespiratory phase of the heart has numerous applications during cardiac imaging. In this article we propose a novel view-angle independent near-real time cardiorespiratory motion gating and coronary sinus (CS) catheter tracking technique for x-ray fluoroscopy images that are used to guide ca...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/20/8087
更新日期:2015-10-21 00:00:00
abstract::Temperature distributions resulting from hyperthermia treatments on isolated perfused bovine tongues were compared with simulations by a treatment planning system. The aim was to test whether the discrete vessel model used for the treatment planning is able to predict correct generic temperature distributions. Tongues...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/5/011
更新日期:1998-05-01 00:00:00
abstract::Respiratory motion in emission tomography leads to reduced image quality. Developed correction methodology has been concentrating on the use of respiratory synchronized acquisitions leading to gated frames. Such frames, however, are of low signal-to-noise ratio as a result of containing reduced statistics. In this wor...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/17/006
更新日期:2007-09-07 00:00:00
abstract::The measurand relevant for the dosimetry for radiation therapy is the absorbed dose to water, DW. The Physikalisch-Technische Bundesanstalt (PTB) is establishing a secondary standard for DW for high-energy photon and electron radiation based on electron spin resonance (ESR) of the amino acid alanine. For practical app...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/5/006
更新日期:2008-03-07 00:00:00
abstract::Computer tomographic (CT) scans are used to correct for tissue inhomogeneities in radiotherapy treatment planning. In order to guarantee a precise treatment, it is important to obtain the relationship between CT Hounsfield units and electron densities (or proton stopping powers for proton radiotherapy), which is the b...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/41/1/009
更新日期:1996-01-01 00:00:00
abstract::The aim of this study is to calculate realistic dose distributions that include the continuous deformation of organs and continuous motion of machine using 4D Monte Carlo methods for both volumetric modulated arc therapy and helical tomotherapy treatments. As part of a previous study, we presented a method to perform ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/9/2807
更新日期:2013-05-07 00:00:00
abstract::Pediatric patients who received radiation therapy are at risk of developing side effects such as radiogenic second cancer. We compared proton and photon therapies in terms of the predicted risk of second cancers for a 4 year old medulloblastoma patient receiving craniospinal irradiation (CSI). Two CSI treatment plans ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/4/807
更新日期:2013-02-21 00:00:00
abstract::In modern radiotherapy the verification of complex treatments plans is often performed in inhomogeneous or even anthropomorphic phantoms. For dose verification small detectors are necessary and therefore alanine detectors are most suitable. Though the response of alanine for a wide range of clinical photon energies in...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/3/N70
更新日期:2016-02-07 00:00:00
abstract::The dose-response of LiF:Mg,Ti (TLD-100) exposed to 15 and 35 kVp (8.0 +/- 0.1 and 8.1 +/- 0.1 keV effective energy respectively) x-rays and 60Co gamma-rays has been measured in the dose interval from (1.2-5.4) x 10(3) Gy for x-rays, and from 0.14 to 850 Gy for gamma-rays. In both cases the total TL signal and glow cu...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/8/006
更新日期:1998-08-01 00:00:00
abstract::In stereotactic radiosurgery, a seven-irradiation film was used to define any discrepancy between the beam and target centres. A mathematical model based on the linac alignment and target set-up was developed to diagnose the discrepancies of the seven-irradiation film between the beam and simulation target centres. Fr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/41/9/003
更新日期:1996-09-01 00:00:00
abstract::A number of heating sources are available for minimally invasive thermal therapy of tumours. The purpose of this work was to compare, theoretically, the heating characteristics of interstitial microwave, laser and ultrasound sources in three tissue sites: breast, brain and liver. Using a numerical method, the heating ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/12/011
更新日期:1998-12-01 00:00:00
abstract::A micro-multileaf collimator (microMLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the microMLC does not allow 'direct'...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/15/305
更新日期:2003-08-07 00:00:00
abstract::Breast-conserving surgery is a standard option for the treatment of patients with early-stage breast cancer. This form of surgery may result in incomplete excision of the tumor. Iodine-125 labeled titanium seeds are currently used in clinical practice to reduce the number of incomplete excisions. It seems likely that ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/19/7655
更新日期:2015-10-07 00:00:00
abstract::Beta emitting 106Ru-applicators are used to treat choroidal melanoma. In order to improve the accuracy and simplify the dosimetry of these applicators, the suitability of using a p-type silicon semiconductor detector has been investigated. The detector is calibrated in a low energy electron beam. An important property...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/36/7/005
更新日期:1991-07-01 00:00:00
abstract::Automatic cell cycle analysis (DNA histograms) is usually performed with flow cytometry. In cases when only few cells are available, the DNA content has to be measured with a fluorescence microscope combined with sensitive camera systems (SIT, MCP, cooled CCDs) and a frame grabber for image analysis. The fluorescent c...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/41/3/013
更新日期:1996-03-01 00:00:00
abstract::The aim of the study is to determine PTV margin for inter-observer variability in the volumetric modulated arc therapy (VMAT) prostate radiotherapy with high-dose volumetric CT (HDVCT) and conventional helical CT (CCT) for planning. Secondly to investigate the impact of geometric (PTV expansion) and dosimetric (confor...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab050f
更新日期:2019-03-14 00:00:00
abstract::Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (q...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/14/4683
更新日期:2012-07-21 00:00:00
abstract::The weak absorption of shortwave infrared light by skin tissues between 700 and 1500 nm offers an important window for diagnosis by optical means. The strong scattering of shortwave infrared light by the skin, however, presents a challenge to the modelling of light propagation through the skin and the understanding of...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/1/312
更新日期:2001-01-01 00:00:00
abstract::During image-guided cancer radiation treatment, three-dimensional (3D) tumor volumetric information is important for treatment success. However, it is typically not feasible to image a patient's 3D tumor continuously in real time during treatment due to concern over excessive patient radiation dose. We present a new i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa56b2
更新日期:2017-02-21 00:00:00
abstract::Prompt γ-ray imaging with a knife-edge shaped slit camera provides the possibility of verifying proton beam range in tumor therapy. Dedicated experiments regarding the characterization of the camera system have been performed previously. Now, we aim at implementing the prototype into clinical application of monitoring...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/22/7881
更新日期:2016-11-21 00:00:00
abstract::Image reconstruction of ultrasound computed tomography based on the wave equation is able to show much more structural details than simpler ray-based image reconstruction methods. However, to invert the wave-based forward model is computationally demanding. To address this problem, we develop an efficient fully learne...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abb5c3
更新日期:2020-11-27 00:00:00
abstract::We report on a novel method for simultaneous biological optimization of treatment plans for hypoxic tumors using multiple ion species. Our previously introduced kill painting approach, where the overall cell killing is optimized on biologically heterogeneous targets, was expanded with the capability of handling differ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aafe40
更新日期:2019-02-08 00:00:00
abstract::This study investigated the integration of the Calypso real-time tracking system, based on implanted ferromagnetic transponders and a detector array, into the current process for image-guided radiation treatment (IGRT) of prostate cancer at our institution. The current IGRT process includes magnetic resonance imaging ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/17/N03
更新日期:2009-09-07 00:00:00
abstract::Pulsed nuclear magnetic resonance imaging (NMRI) apparatus has developed very quickly. On the other hand, the development of apparatus for pulsed electron paramagnetic resonance imaging (EPRI) has been very slow. This fact is due to the extremely reduced relaxation times of the paramagnetic probes. EPR linewidths are ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/6/409
更新日期:1999-06-01 00:00:00
abstract::In robotic radiosurgery, it is necessary to compensate for systematic latencies arising from target tracking and mechanical constraints. This compensation is usually achieved by means of an algorithm which computes the future target position. In most scientific works on respiratory motion prediction, only one or two a...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/11/3911
更新日期:2013-06-07 00:00:00
abstract::In this study, the quantitative accuracy of different attenuation correction strategies presently available for the High Resolution Research Tomograph (HRRT) was investigated. These attenuation correction methods differ in reconstruction and processing (segmentation) algorithms used for generating a micro-image from m...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/1/007
更新日期:2008-01-07 00:00:00
abstract::Maximum likelihood estimation (MLE) is presented as a statistical tool to evaluate the contribution of measurement error to any measurement series where the same quantity is measured using different independent methods. The technique was tested against artificial data sets; generated for values of underlying variation...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/20/6019
更新日期:2014-10-21 00:00:00
abstract::We experimentally investigated the SPECT recovery of I-131 activity in multiple spheres located simultaneously at different locations within a cylindrical phantom that had an elliptical cross section. The sphere volumes ranged from 209 cc down to 4.2 cc. A Prism 3000 camera and two types of parallel-hexagonal-hole col...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/3/017
更新日期:2007-02-07 00:00:00