Viscoelastic characterization of thin tissues using acoustic radiation force and model-based inversion.

Abstract:

:By means of the viscoelastodynamic model for a two-layer solid-fluid system and a detailed account of the locally induced acoustic radiation force, a rational analytical and computational framework is established for the viscoelastic characterization of thin tissues from high-frequency ultrasound (HFUS) measurements. For practical applications, the back-analysis is set up to interpret the frequency response function, signifying the tissue's axial displacement (captured by the imaging transducer) per squared voltage driving the 'pushing' transducer, as experimental input. On parametrizing the tissue's viscoelastic behavior in terms of the standard linear model, the proposed methodology is applied to a set of measurements performed on tissue-mimicking phantom constructs with thicknesses ranging from 0.5 to 4 mm. The results demonstrate that the model-based inversion, which carefully mimics the local boundary conditions and applied ultrasound excitation, yields viscoelastic properties for the phantom that are virtually invariant over the range of specimen thicknesses tested. Beyond its immediate application to in vitro viscoelastic characterization of thin excised tissues and tissue constructs, the proposed methodology may also find use in the characterization of skin or skin lesions over bone in vivo.

journal_name

Phys Med Biol

authors

Guzina BB,Tuleubekov K,Liu D,Ebbini ES

doi

10.1088/0031-9155/54/13/009

subject

Has Abstract

pub_date

2009-07-07 00:00:00

pages

4089-112

issue

13

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(09)91295-7

journal_volume

54

pub_type

杂志文章
  • Computational dosimetry for grounded and ungrounded human models due to contact current.

    abstract::This study presents the computational dosimetry of contact currents for grounded and ungrounded human models. The uncertainty of the quasi-static (QS) approximation of the in situ electric field induced in a grounded/ungrounded human body due to the contact current is first estimated. Different scenarios of cylindrica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/15/5153

    authors: Chan KH,Hattori J,Laakso I,Hirata A,Taki M

    更新日期:2013-08-07 00:00:00

  • Development of an MR-compatible gamma probe for combined MR/RI guided surgery.

    abstract::We have developed and tested an MR-compatible gamma probe to simultaneously obtain anatomical information and functional information during surgery. The probe consists of a probe head, an optical fibre bundle and a photo-multiplier tube (PMT). The NaI(T1) scintillator contained in the probe head is connected to a 7 m ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/15/005

    authors: Yamamoto S,Kuroda K,Senda M

    更新日期:2004-08-07 00:00:00

  • Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms (MRCPs).

    abstract::Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advanta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcdb

    authors: Lee H,Yeom YS,Nguyen TT,Choi C,Han H,Shin B,Zhang X,Kim CH,Chung BS,Zankl M

    更新日期:2019-02-05 00:00:00

  • Fricke dosimetry: the difference between G(Fe3+) for 60Co gamma-rays and high-energy x-rays.

    abstract::A calibration of the Fricke dosimeter is a measurement of epsilon G(Fe3+). Although G(Fe3+) is expected to be approximately energy independent for all low-LET radiation, existing data are not adequate to rule out the possibility of changes of a few per cent with beam quality. When a high-precision Fricke dosimeter, wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/303

    authors: Klassen NV,Shortt KR,Seuntjens J,Ross CK

    更新日期:1999-07-01 00:00:00

  • Spectral x-ray imaging: Conditions under which propagation-based phase-contrast is beneficial.

    abstract::Energy-resolved attenuation data in spectral x-ray imaging enables material decomposition, in which the different materials inside an object can be identified and separated virtually. Material decomposition has the drawback of increased noise in the resulting material images relative to the measured images. Recently, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba318

    authors: Schaff F,Morgan KS,Paganin DM,Kitchen MJ

    更新日期:2020-10-07 00:00:00

  • A motion-incorporated reconstruction method for gated PET studies.

    abstract::Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/15/012

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi OR

    更新日期:2006-08-07 00:00:00

  • Analytical description of dose profile behaviour in Gamma Knife radiosurgery.

    abstract::Stereotactic Gamma Knife radiosurgery utilizes ionizing beams from (60)Co sources and relies on a combination of collimator sizes, weighting, etc to generate a high-dose region that is conformal with a designated target volume. Dose computation is typically performed by computer, but in this paper, single collimator d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/8/003

    authors: Fenner J,Gwilliam M,Mehrem R,Bird A,Walton L

    更新日期:2008-04-21 00:00:00

  • Distributed three-dimensional simulation of B-mode ultrasound imaging using a first-order k-space method.

    abstract::Computational modeling is an important tool in ultrasound imaging research, but realistic three-dimensional (3D) simulations can exceed the capabilities of serial computers. This paper uses a 3D simulator based on a k-space method that incorporates relaxation absorption and nonreflecting boundary conditions. The simul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/17/007

    authors: Daoud MI,Lacefield JC

    更新日期:2009-09-07 00:00:00

  • Trimmer sequencing time minimization during dynamically collimated proton therapy using a colony of cooperating agents.

    abstract::The dynamic collimation system (DCS) can be combined with pencil beam scanning proton therapy to deliver highly conformal treatment plans with unique collimation at each energy layer. This energy layer-specific collimation is accomplished through the synchronized motion of four trimmer blades that intercept the proton...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab416d

    authors: Smith BR,Hyer DE,Flynn RT,Hill PM,Culberson WS

    更新日期:2019-10-21 00:00:00

  • Automated sonographic evaluation of testicular perfusion.

    abstract::Contrast-enhanced ultrasound (US) imaging is potentially applicable to the investigation of vascular disorders of the testis. We investigated the ability of two automated computer algorithms to analyse contrast-enhanced pulse inversion US data in a rabbit model of unilateral testicular ischaemia and to correctly deter...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/14/010

    authors: Thierman JS,Clement GT,Kalish LA,O'Kane PL,Frauscher F,Paltiel HJ

    更新日期:2006-07-21 00:00:00

  • Quantification of the trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy by using a dual-energy (SPECT/)CT.

    abstract::A complete characterization of spongiosa (bone marrow plus trabecular bone) is required to calculate the absorbed dose to active bone marrow. Due to the complex microanatomy, it is necessary to apply non-conventional imaging methods in nuclear medicine. The aim of this study is validating a phantomless quantification ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4476

    authors: Salas-Ramirez M,Tran-Gia J,Gbureck U,Kosmala A,Lassmann M

    更新日期:2019-10-16 00:00:00

  • Linear dimension reduction of sequences of medical images: I. Optimal inner products.

    abstract::A general theory is presented for minimizing noise in linear dimension reduction of sequences of medical images when the factors and the covariance matrix and mean of the noise are given. A dimension reduction is optimal when all diagonal elements in the covariance matrix of the noise in the signal (factor) space are ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/11/010

    authors: Hermansen F,Lammertsma AA

    更新日期:1995-11-01 00:00:00

  • Clinical ultraviolet dosimetry with a CCD monochromator array spectroradiometer.

    abstract::Single monochromator charge-coupled device (CCD) array spectroradiometers have the advantage of ease of use and speed compared with double grating instruments. Their inherently inferior stray-light rejection, however, can critically affect their accuracy in phototherapy and research-related dosimetry applications. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/026

    authors: Coleman A,Sarkany R,Walker S

    更新日期:2008-09-21 00:00:00

  • SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms.

    abstract::This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa77ea

    authors: Cros M,Joemai RMS,Geleijns J,Molina D,Salvadó M

    更新日期:2017-07-17 00:00:00

  • Dosimetry comparison and characterisation of an Al K ultrasoft x-ray beam from an MRC cold-cathode source.

    abstract::Ultrasoft x-rays of 0.3-5 keV have provided a unique tool for the investigation of intracellular mechanisms of radiation action in biological organisms, including mammalian cells. However, their use presents unique practical problems in dosimetry and experimental design. Detailed interpretation of the biological resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/10/002

    authors: Hoshi M,Goodhead DT,Brenner DJ,Bance DA,Chmielewski JJ,Paciotti MA,Bradbury JN

    更新日期:1985-10-01 00:00:00

  • Leveraging multi-layer imager detector design to improve low-dose performance for megavoltage cone-beam computed tomography.

    abstract::While megavoltage cone-beam computed tomography (CBCT) using an electronic portal imaging device (EPID) provides many advantages over kilovoltage (kV) CBCT, clinical adoption is limited by its high doses. Multi-layer imager (MLI) EPIDs increase DQE(0) while maintaining high resolution. However, even well-designed, hig...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa160

    authors: Hu YH,Rottmann J,Fueglistaller R,Myronakis M,Wang A,Huber P,Shedlock D,Morf D,Baturin P,Star-Lack J,Berbeco R

    更新日期:2018-01-30 00:00:00

  • Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors.

    abstract::In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6571

    authors: Roncali E,Phipps JE,Marcu L,Cherry SR

    更新日期:2012-10-21 00:00:00

  • In vivo and in vitro dielectric properties of feline tissues at low radiofrequencies.

    abstract::The dielectric constant and conductivity of muscle, liver, spleen and kidney of cats in vivo and in situ immediately following the animal's death were measured at frequencies from 10 kHz to 100 MHz. A novel multi-ring capacitive sensor and a computer-controlled automatic network analyser (ANA) were employed. The resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/8/007

    authors: Surowiec A,Stuchly SS,Keaney M,Swarup A

    更新日期:1986-08-01 00:00:00

  • Ultrasound transmission tomography image reconstruction with a fully convolutional neural network.

    abstract::Image reconstruction of ultrasound computed tomography based on the wave equation is able to show much more structural details than simpler ray-based image reconstruction methods. However, to invert the wave-based forward model is computationally demanding. To address this problem, we develop an efficient fully learne...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb5c3

    authors: Zhao W,Wang H,Gemmeke H,van Dongen KWA,Hopp T,Hesser J

    更新日期:2020-11-27 00:00:00

  • Respiratory motion prediction by using the adaptive neuro fuzzy inference system (ANFIS).

    abstract::The quality of radiation therapy delivered for treating cancer patients is related to set-up errors and organ motion. Due to the margins needed to ensure adequate target coverage, many breast cancer patients have been shown to develop late side effects such as pneumonitis and cardiac damage. Breathing-adapted radiatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/19/020

    authors: Kakar M,Nyström H,Aarup LR,Nøttrup TJ,Olsen DR

    更新日期:2005-10-07 00:00:00

  • Photothermal effects of laser tissue soldering.

    abstract::Low-strength anastomoses and thermal damage of tissue are major concerns in laser tissue welding techniques where laser energy is used to induce thermal changes in the molecular structure of the tissues being joined, hence allowing them to bond together. Laser tissue soldering, on the other hand, is a bonding techniqu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/4/013

    authors: McNally KM,Sorg BS,Welch AJ,Dawes JM,Owen ER

    更新日期:1999-04-01 00:00:00

  • Improving single-event proton CT by removing nuclear interaction events within the energy/range detector.

    abstract::Data filtering is crucial for accurate relative stopping power (RSP) reconstruction in proton CT (pCT). In this work, we assess different filters and their performance for the US pCT collaboration prototype pCT system in Monte Carlo (MC) simulations. The potential of using the recently proposed [Formula: see text]-E f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2671

    authors: Volz L,Piersimoni P,Johnson RP,Bashkirov VA,Schulte RW,Seco J

    更新日期:2019-08-01 00:00:00

  • Comparison of Geant4 multiple Coulomb scattering models with theory for radiotherapy protons.

    abstract::Usually, Monte Carlo models are validated against experimental data. However, models of multiple Coulomb scattering (MCS) in the Gaussian approximation are exceptional in that we have theories which are probably more accurate than the experiments which have, so far, been done to test them. In problems directly sensiti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6ce3

    authors: Makarova A,Gottschalk B,Sauerwein W

    更新日期:2017-07-06 00:00:00

  • Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization.

    abstract::Reducing radiation dose in dual energy computed tomography (DECT) is highly desirable but it may lead to excessive noise in the filtered backprojection (FBP) reconstructed DECT images, which can inevitably increase the diagnostic uncertainty. To obtain clinically acceptable DECT images from low-mAs acquisitions, in th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7122

    authors: Zhang H,Zeng D,Lin J,Zhang H,Bian Z,Huang J,Gao Y,Zhang S,Zhang H,Feng Q,Liang Z,Chen W,Ma J

    更新日期:2017-07-07 00:00:00

  • An age-dependent series of eye models for radiation dosimetry.

    abstract::Several studies have been appeared, up to now, that indicate the effect of accurate simulation on dose received by different substructures of the eye, irradiated by external beams of short-range radiation such as electron. Different representations of the eye have consequently been introduced. Their accuracies depend ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2059

    authors: Vejdani-Noghreiyan A,Ebrahimi-Khankook A

    更新日期:2019-07-02 00:00:00

  • Cascaded systems analysis of anatomic noise in digital mammography and dual-energy digital mammography.

    abstract::In x-ray based imaging of the breast, contrast between fibroglandular (Fg) tissue and adipose (Ad) tissue is a source of anatomic noise. The goal of this work was to validate by simulation and experiment a mathematical framework for modelling the Fg component of anatomic noise in digital mammograpy (DM) and dual-energ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3fcd

    authors: Tanguay J,Lalonde R,Bjarnason TA,Yang CJ

    更新日期:2019-10-23 00:00:00

  • Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.

    abstract::We present the results of utilizing aligned anatomical information from CT images to locally adjust image smoothness during the reconstruction of three-dimensional (3D) whole-body positron emission tomography (PET) data. The ability of whole-body PET imaging to detect malignant neoplasms is becoming widely recognized....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/1/301

    authors: Comtat C,Kinahan PE,Fessler JA,Beyer T,Townsend DW,Defrise M,Michel C

    更新日期:2002-01-07 00:00:00

  • The Akaike information criterion in DCE-MRI: does it improve the haemodynamic parameter estimates?

    abstract::The Akaike information criterion and the associated Akaike weights (AW) rank pharmacokinetic models on the basis of goodness-of-fit and number of parameters. The usefulness of this information for improving the haemodynamic parameter estimates from DCE-MRI was investigated through two examples. In each of these, the e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3609

    authors: Luypaert R,Ingrisch M,Sourbron S,de Mey J

    更新日期:2012-06-07 00:00:00

  • An investigation and explanation of the fall-off of x-ray tube current during an exposure.

    abstract::It was observed that the radiation output of x-ray tubes falls off exponentially during an exposure with a time constant of about 120 ms. The equilibrium value is approximately 15% lower than that at the beginning of the exposure. The clinically noticeable consequences are discrepancies in x-ray generator calibration,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/2/004

    authors: Brezovich IA,Barnes GT

    更新日期:1980-03-01 00:00:00

  • Simulation of small-angle x-ray scattering from collagen fibrils and comparison with experimental patterns.

    abstract::Simulation of small-angle x-ray scattering from collagen in healthy and cancerous breast tissue may reveal detailed information on the structural changes in collagen. Collagen fibril is modelled as a cylinder with axially periodic step-function electron density, and packing is approximated by placing the cylinders in ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/22/012

    authors: Suhonen H,Fernández M,Serimaa R,Suortti P

    更新日期:2005-11-21 00:00:00