A convolution-subtraction scatter correction method for 3D PET.

Abstract:

:3D acquisition and reconstruction in positron emission tomography (PET) produce data with improved signal-to-noise ratios compared with conventional 2D slice-oriented methods. However, the sensitivity increase is accompanied by an increase in the number of scattered photons and random coincidences detected. This paper presents a scatter correction technique for 3D PET data where an estimate of the scattered photon distribution is subtracted from the data before reconstruction. The scatter distribution is estimated by iteratively convolving the photopeak projections with a mono-exponential kernel. The method accounts for the 3D acquisition geometry and nature of scatter by performing the scatter estimation on 2D projections. The assumptions of the method have been investigated by measuring the variation in the scatter fraction and the scatter function at different positions in a cylinder. Both parameters were found to vary by up to 50% from the centre to the edge of a large water-filled cylinder. Despite this, in a uniform cylinder containing water with different concentrations of radioactivity, scatter was reduced from 25% in a non-radioactive region to less than 5% using the convolution-subtraction method. In addition, the relative concentration of a cylinder containing an increased concentration, which was underestimated by almost 50% without scatter correction, was within 5% of the true concentration after correction.

journal_name

Phys Med Biol

authors

Bailey DL,Meikle SR

doi

10.1088/0031-9155/39/3/009

subject

Has Abstract

pub_date

1994-03-01 00:00:00

pages

411-24

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

39

pub_type

杂志文章
  • A method for determining the diffusion coefficient in Fe(II/III) radiation dosimetry gels using finite elements.

    abstract::Magnetic resonance imaging (MRI) may be used to image three-dimensional dose distributions of ionizing radiation in tissue equivalent gels infused with ferrous sulphate solutions, commonly known as Fricke gels. In this technique, ferrous (Fe2+) ions are oxidized to ferric (Fe3+) ions by free radicals produced by ioniz...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/9/013

    authors: Harris PJ,Piercy A,Baldock C

    更新日期:1996-09-01 00:00:00

  • FPGA-based distributed coincidence processor for high count-rate online PET coincidence data acquisition.

    abstract::For PET online data acquisition, a centralized coincidence processor (CCP) with a single-thread data processing has been used to select coincidence events for many PET scanners. CCP has the advantage of highly integrated circuit, compact connection between detector front-end and system electronics, and centralized con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abde85

    authors: Cheng X,Hu K,Yang D,Shao Y

    更新日期:2021-01-21 00:00:00

  • A strategy to minimize errors from differential intrafraction organ motion using a single configuration for a 'breathing' multileaf collimator.

    abstract::Intensity-modulated radiation therapy (IMRT) can be delivered by the 'sliding-leaves' dynamic multileaf collimator (DMLC) technique. Intrafraction organ motion can be accommodated by arranging an identical tracking motion for 'breathing leaves'. However, this is only possible for very specific circumstances such as re...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/18/005

    authors: Webb S,Binnie DM

    更新日期:2006-09-21 00:00:00

  • ICRP Publication 116--the first ICRP/ICRU application of the male and female adult reference computational phantoms.

    abstract::ICRP Publication 116 on 'Conversion coefficients for radiological protection quantities for external radiation exposures', provides fluence-to-dose conversion coefficients for organ-absorbed doses and effective dose for various types of external exposures (ICRP 2010 ICRP Publication 116). The publication supersedes th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/18/5209

    authors: Petoussi-Henss N,Bolch WE,Eckerman KF,Endo A,Hertel N,Hunt J,Menzel HG,Pelliccioni M,Schlattl H,Zankl M

    更新日期:2014-09-21 00:00:00

  • Navigated non-contact fluorescence tomography.

    abstract::A non-contact approach for diffuse optical tomography (DOT) has been developed for on-demand image updates using surgical navigation technology. A stereoscopic optical tracker provides real-time localization of reflective spheres mounted to a laser diode and near-infrared camera. Standard camera calibration is combine...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1f33

    authors: Daly MJ,Wilson BC,Irish JC,Jaffray DA

    更新日期:2019-07-05 00:00:00

  • Monte Carlo calculations of the energy response of lithium dosemeters to high energy electrons (less than 30 MeV).

    abstract::Monte Carlo calculations of the energy response of LiF dosemeters have been carried out to help resolve the discrepancy between the measurements of Holt, Edelstein and Clark (1975) and those of Paliwal and Almond (1975) and others. It is concluded that the assumptions used by Holt et al. are largely responsible. They ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/5/003

    authors: O'Brien K

    更新日期:1977-09-01 00:00:00

  • Thermoluminescent response and relative efficiency of TLD-100 exposed to low-energy x-rays.

    abstract::The dose-response of LiF:Mg,Ti (TLD-100) exposed to 15 and 35 kVp (8.0 +/- 0.1 and 8.1 +/- 0.1 keV effective energy respectively) x-rays and 60Co gamma-rays has been measured in the dose interval from (1.2-5.4) x 10(3) Gy for x-rays, and from 0.14 to 850 Gy for gamma-rays. In both cases the total TL signal and glow cu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/006

    authors: Gamboa-deBuen I,Buenfil AE,Ruiz CG,Rodríguez-Villafuerte M,Flores A,Brandan ME

    更新日期:1998-08-01 00:00:00

  • Physics considerations in MV-CBCT multi-layer imager design.

    abstract::Megavoltage (MV) cone-beam computed tomography (CBCT) using an electronic portal imaging (EPID) offers advantageous features, including 3D mapping, treatment beam registration, high-z artifact suppression, and direct radiation dose calculation. Adoption has been slowed by image quality limitations and concerns about i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac8c6

    authors: Hu YH,Fueglistaller R,Myronakis M,Rottmann J,Wang A,Shedlock D,Morf D,Baturin P,Huber P,Star-Lack J,Berbeco R

    更新日期:2018-06-20 00:00:00

  • Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy.

    abstract::A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/4/001

    authors: Kezerashvili M,Bednarek DR,Rudin S

    更新日期:1997-04-01 00:00:00

  • Towards patient specific thermal modelling of the prostate.

    abstract::The application of thermal modelling for hyperthermia and thermal ablation is severely hampered by lack of information about perfusion and vasculature. However, recently, with the advent of sophisticated angiography and dynamic contrast enhanced (DCE) imaging techniques, it has become possible to image small vessels a...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/51/4/004

    authors: Van den Berg CA,Van de Kamer JB,De Leeuw AA,Jeukens CR,Raaymakers BW,van Vulpen M,Lagendijk JJ

    更新日期:2006-02-21 00:00:00

  • Lateral variations of radiobiological properties of therapeutic fields of 1H, 4He, 12C and 16O ions studied with Geant4 and microdosimetric kinetic model.

    abstract::As known, in cancer therapy with ion beams the relative biological effectiveness (RBE) of ions changes in the course of their propagation in tissues. Such changes are caused not only by increasing the linear energy transfer (LET) of beam particles with the penetration depth towards the Bragg peak, but also by nuclear ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa75b2

    authors: Dewey S,Burigo L,Pshenichnov I,Mishustin I,Bleicher M

    更新日期:2017-06-27 00:00:00

  • Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.

    abstract::A method to measure the detector-to-object distance from the images obtained with stationary high-spatial-resolution gamma-ray cameras for in vivo studies has been developed. It exploits the shift of the imaged object in the image plane, obtained at a certain tilt of the parallel-hole collimator. A linear dependence o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/N04

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Bollini D,de Notaristefani F

    更新日期:2006-05-07 00:00:00

  • Reduction of scatter in breast CT yields improved microcalcification visibility.

    abstract::The inadequate visibility of microcalcifications-small calcium deposits that cue radiologists to early stages of cancer-is a major limitation in current designs of dedicated breast computed tomography (bCT). This limitation has previously been attributed to the constituent components, spatial resolution, and utilized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abae07

    authors: Ghazi P

    更新日期:2020-12-04 00:00:00

  • Construction of a biomechanical head and neck motion model as a guide to evaluation of deformable image registration.

    abstract::The use of deformable image registration methods in the context of adaptive radiotherapy leads to uncertainties in the simulation of the administered dose distributions during the treatment course. Evaluation of these methods is a prerequisite to decide if a plan adaptation will improve the individual treatment. Curre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa69b6

    authors: Teske H,Bartelheimer K,Meis J,Bendl R,Stoiber EM,Giske K

    更新日期:2017-06-21 00:00:00

  • Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator.

    abstract::A new component module (CM), designated DYNVMLC, was developed to fully model the geometry of the Varian Millennium 120 leaf collimator using the BEAMnrc Monte Carlo code. The model includes details such as the leaf driving screw hole, support railing groove and leaf tips. Further modifications also allow sampling of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/004

    authors: Heath E,Seuntjens J

    更新日期:2003-12-21 00:00:00

  • Inclusion of thin target and source regions in alimentary and respiratory tract systems of mesh-type ICRP adult reference phantoms.

    abstract::It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5b72

    authors: Kim HS,Yeom YS,Nguyen TT,Choi C,Han MC,Lee JK,Kim CH,Zankl M,Petoussi-Henss N,Bolch WE,Lee C,Qiu R,Eckerman K,Chung BS

    更新日期:2017-03-21 00:00:00

  • Metal artifact reduction method based on a constrained beam-hardening estimator for polychromatic x-ray CT.

    abstract::Beam hardening is inevitable due to the polychromatic X-ray spectrum and energy-dependent attenuation coefficients of materials, leading to the underestimation of artifacts arising from projection data, especially on metal regions. State-of-the-art research on beam-hardening artifacts is based on a numerical method th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe026

    authors: Hur J,Kim D,Shin YG,Lee H

    更新日期:2021-01-26 00:00:00

  • In vivo real-time cavitation imaging in moving organs.

    abstract::The stochastic nature of cavitation implies visualization of the cavitation cloud in real-time and in a discriminative manner for the safe use of focused ultrasound therapy. This visualization is sometimes possible with standard echography, but it strongly depends on the quality of the scanner, and is hindered by diff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa4fe8

    authors: Arnal B,Baranger J,Demene C,Tanter M,Pernot M

    更新日期:2017-02-07 00:00:00

  • Directional dependence in film dosimetry: radiographic and radiochromic film.

    abstract::The trend towards conformal, intensity modulated radiotherapy treatments has established the need for a true integrating dosimeter. In traditional radiotherapy, radiographic film dosimetry is commonly used. The accuracy and reproducibility of film optical density as an indicator of dose is influenced by several variab...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/5/305

    authors: Suchowerska N,Hoban P,Butson M,Davison A,Metcalfe P

    更新日期:2001-05-01 00:00:00

  • Clinical evaluation of 4D PET motion compensation strategies for treatment verification in ion beam therapy.

    abstract::A clinical trial named PROMETHEUS is currently ongoing for inoperable hepatocellular carcinoma (HCC) at the Heidelberg Ion Beam Therapy Center (HIT, Germany). In this framework, 4D PET-CT datasets are acquired shortly after the therapeutic treatment to compare the irradiation induced PET image with a Monte Carlo PET p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4141

    authors: Gianoli C,Kurz C,Riboldi M,Bauer J,Fontana G,Baroni G,Debus J,Parodi K

    更新日期:2016-06-07 00:00:00

  • Adaptive treatment-length optimization in spatiobiologically integrated radiotherapy.

    abstract::Recent theoretical research on spatiobiologically integrated radiotherapy has focused on optimization models that adapt fluence-maps to the evolution of tumor state, for example, cell densities, as observed in quantitative functional images acquired over the treatment course. We propose an optimization model that adap...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab4b6

    authors: Ajdari A,Ghate A,Kim M

    更新日期:2018-03-27 00:00:00

  • Improved dose-calculation accuracy in proton treatment planning using a simplified Monte Carlo method verified with three-dimensional measurements in an anthropomorphic phantom.

    abstract::Treatment planning for proton tumor therapy requires a fast and accurate dose-calculation method. We have implemented a simplified Monte Carlo (SMC) method in the treatment planning system of the National Cancer Center Hospital East for the double-scattering beam delivery scheme. The SMC method takes into account the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/018

    authors: Hotta K,Kohno R,Takada Y,Hara Y,Tansho R,Himukai T,Kameoka S,Matsuura T,Nishio T,Ogino T

    更新日期:2010-06-21 00:00:00

  • Concentrations of Fe, Cu and Zn in breast tissue: a synchrotron XRF study.

    abstract::An x-ray fluorescence system with a synchrotron radiation source was used to quantify the levels of iron, copper and zinc in breast tissue specimens. Healthy tissue and breast carcinomas were investigated as an aid to understanding the mechanisms of breast cancer and as a possible complementary diagnostic tool. Eighty...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/13/310

    authors: Geraki K,Farquharson MJ,Bradley DA

    更新日期:2002-07-07 00:00:00

  • A new treatment planning approach accounting for prompt gamma range verification and interfractional anatomical changes.

    abstract::Prompt gamma (PG) imaging is widely investigated for spot-by-spot in vivo range verification for proton therapy. Previous studies pointed out that the accuracy of prompt gamma imaging is affected by the statistics (number of protons delivered per pencil beam) of the proton beams and the conformity between prompt gamma...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7d15

    authors: Tian L,Landry G,Dedes G,Pinto M,Kamp F,Belka C,Parodi K

    更新日期:2020-04-29 00:00:00

  • The effect of authentic metallic implants on the SAR distribution of the head exposed to 900, 1800 and 2450 MHz dipole near field.

    abstract::As the use of radiofrequency (RF) electromagnetic (EM) fields has increased along with increased use of wireless communication, the possible related health risks have also been widely discussed. One safety aspect is the interaction of medical implants and RF devices like mobile phones. In the literature, effects on ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/001

    authors: Virtanen H,Keshvari J,Lappalainen R

    更新日期:2007-03-07 00:00:00

  • Tomographic sensing and localization of fluorescently labeled circulating cells in mice in vivo.

    abstract::Sensing and enumeration of specific types of circulating cells in small animals is an important problem in many areas of biomedical research. Microscopy-based fluorescence in vivo flow cytometry methods have been developed previously, but these are typically limited to sampling of very small blood volumes, so that ver...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4627

    authors: Zettergren E,Swamy T,Runnels J,Lin CP,Niedre M

    更新日期:2012-07-21 00:00:00

  • Microwave tomography for functional imaging of extremity soft tissues: feasibility assessment.

    abstract::It is important to assess the viability of extremity soft tissues, as this component is often the determinant of the final outcome of fracture treatment. Microwave tomography (MWT) and sensing might be able to provide a fast and mobile assessment of such properties. MWT imaging of extremities possesses a complicated, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/18/015

    authors: Semenov S,Kellam J,Althausen P,Williams T,Abubakar A,Bulyshev A,Sizov Y

    更新日期:2007-09-21 00:00:00

  • A static beam delivery device for fast scanning proton arc-therapy.

    abstract::Arc-therapy is a dose delivery technique regularly applied in photon radiation therapy, and is currently subject of great interest for proton therapy as well. In this technique, proton beams are aimed at a tumor from different continuous ranges of incident directions (so called "arcs"). This technique can potentially ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe02b

    authors: Nesteruk KP,Bolsi A,Lomax AJ,Meer D,van de Water S,Schippers JM

    更新日期:2021-01-26 00:00:00

  • Head scatter modelling for irregular field shaping and beam intensity modulation.

    abstract::Scattered radiation from within the treatment head can contribute significant dose to all parts of a radiotherapy treatment field. A multileaf collimator may be used to create an arbitrarily shaped field, and may also be used, under dynamic control, to modulate the beam intensity over the field. This method of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/9/006

    authors: Hounsell AR,Wilkinson JM

    更新日期:1997-09-01 00:00:00

  • Three-dimensional performance of a small-diameter positron emission tomograph.

    abstract::Recently, the initial 2D physical characterization of a small-diameter positron emission tomograph, designed specifically for scanning of small laboratory animals, was reported. The physical characteristics of the tomograph operating in 3D mode have now been measured and compared to those obtained in 2D mode. In 3D, t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/2/010

    authors: Bloomfield PM,Myers R,Hume SP,Spinks TJ,Lammertsma AA,Jones T

    更新日期:1997-02-01 00:00:00