Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction.

Abstract:

:Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image reconstruction. A trade-off has to be made regarding the size of the ECG-gating window. A large temporal window is desirable to avoid undersampling. However, residual motion will occur in a large window, causing motion artefacts. We present an algorithm to correct for residual motion. Our approach is based on a deformable 2D-2D registration between the forward projection of an initial, ECG-gated reconstruction, and the original projection data. The approach is fully automatic and does not require any complex segmentation of vasculature, or landmarks. The estimated motion is compensated for during the backprojection step of a subsequent reconstruction. We evaluated the method using the publicly available CAVAREV platform and on six human clinical datasets. We found a better visibility of structure, reduced motion artefacts, and increased sharpness of the vessels in the compensated reconstructions compared to the initial reconstructions. At the time of writing, our algorithm outperforms the leading result of the CAVAREV ranking list. For the clinical datasets, we found an average reduction of motion artefacts by 13 ± 6%. Vessel sharpness was improved by 25 ± 12% on average.

journal_name

Phys Med Biol

authors

Schwemmer C,Rohkohl C,Lauritsch G,Müller K,Hornegger J

doi

10.1088/0031-9155/58/11/3717

subject

Has Abstract

pub_date

2013-06-07 00:00:00

pages

3717-37

issue

11

eissn

0031-9155

issn

1361-6560

journal_volume

58

pub_type

杂志文章
  • Modeling the radiation-induced cell death in a therapeutic proton beam using thermoluminescent detectors and radiation transport simulations.

    abstract::Changes in the relative biological effectiveness (RBE) of the radiation-induced cell killing of human salivary glands (HSG) were assessed along the Bragg peak of a 60 MeV clinical proton beam by means of coupling biophysical models with the results of Monte Carlo radiation transport simulations and experimental measur...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab491f

    authors: Parisi A,Olko P,Swakoń J,Horwacik T,Jabłoński H,Malinowski L,Nowak T,Struelens L,Vanhavere F

    更新日期:2020-01-10 00:00:00

  • Direct 4D reconstruction of parametric images incorporating anato-functional joint entropy.

    abstract::We developed an anatomy-guided 4D closed-form algorithm to directly reconstruct parametric images from projection data for (nearly) irreversible tracers. Conventional methods consist of individually reconstructing 2D/3D PET data, followed by graphical analysis on the sequence of reconstructed image frames. The propose...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/15/005

    authors: Tang J,Kuwabara H,Wong DF,Rahmim A

    更新日期:2010-08-07 00:00:00

  • Perturbation correction for alanine dosimeters in different phantom materials in high-energy photon beams.

    abstract::In modern radiotherapy the verification of complex treatments plans is often performed in inhomogeneous or even anthropomorphic phantoms. For dose verification small detectors are necessary and therefore alanine detectors are most suitable. Though the response of alanine for a wide range of clinical photon energies in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/3/N70

    authors: von Voigts-Rhetz P,Anton M,Vorwerk H,Zink K

    更新日期:2016-02-07 00:00:00

  • The unique determination of the primary current by MEG and EEG.

    abstract::In this paper, we use a more realistic head model with ovoid geometry for approximation of a human head. By inverting the Geselowitz equation, some analytic results on the inverse MEG problem are presented in homogenous ovoid geometry. On one hand, some information about the components of primary current is shown by t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/21/012

    authors: Peng L,Cheng J,Jin L

    更新日期:2006-11-07 00:00:00

  • A new approach to account for the medium-dependent effect in model-based dose calculations for kilovoltage x-rays.

    abstract::This study presents a new approach to accurately account for the medium-dependent effect in model-based dose calculations for kilovoltage (kV) x-rays. This approach is based on the hypothesis that the correction factors needed to convert dose from model-based dose calculations to absorbed dose-to-medium depend on both...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/011

    authors: Pawlowski JM,Ding GX

    更新日期:2011-07-07 00:00:00

  • In-bore setup and software for 3T MRI-guided transperineal prostate biopsy.

    abstract::MRI-guided prostate biopsy in conventional closed-bore scanners requires transferring the patient outside the bore during needle insertion due to the constrained in-bore space, causing a safety hazard and limiting image feedback. To address this issue, we present our custom-made in-bore setup and software to support M...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/18/5823

    authors: Tokuda J,Tuncali K,Iordachita I,Song SE,Fedorov A,Oguro S,Lasso A,Fennessy FM,Tempany CM,Hata N

    更新日期:2012-09-21 00:00:00

  • Torsion measurement of catheters using polarized light in a single glass fibre.

    abstract::Several types of intravascular ultrasound (IVUS) catheters are connected to a motor at their proximal end, in order to let the catheter rotate around its length axis. However, the rotation of the distal axis tip does not follow exactly the rotation of the motor, since the catheter axis is not completely torsion-free a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/5/001

    authors: Konings MK,van Leeuwen TG,Mali WP,Viergever MA

    更新日期:1998-05-01 00:00:00

  • Towards a gold standard for quantitative coronary arteriography.

    abstract::Densitometric quantification of coronary artery stenoses in angiographic images can be problematic for two reasons: (i) the x-rays are inadequately oriented with respect to the vessel segments of interest at image acquisition; (ii) non-linear effects due for instance to beam hardening, scattered radiation and veiling ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/011

    authors: Doriot PA,Dorsaz PA,Dorsaz L,Bodenmann JJ

    更新日期:1997-12-01 00:00:00

  • A complete distortion correction for MR images: II. Rectification of static-field inhomogeneities by similarity-based profile mapping.

    abstract::Radiotherapy treatment planning relies on the use of geometrically correct images. This paper presents a fully automatic tool for correcting MR images for the effects of B(0) inhomogeneities. The post-processing method is based on the gradient-reversal technique of Chang and Fitzpatrick (1992 IEEE Trans. Med. Imaging ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/11/014

    authors: Reinsberg SA,Doran SJ,Charles-Edwards EM,Leach MO

    更新日期:2005-06-07 00:00:00

  • Local organ dose conversion coefficients for angiographic examinations of coronary arteries.

    abstract::New organ dose conversion coefficients for coronary angiographic interventions are presented, as well as dose distributions and resulting maximal local dose conversion coefficients in the relevant organs. For the Monte Carlo based simulations, voxel models of the human anatomy were employed which represent the average...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/15/003

    authors: Schlattl H,Zankl M,Hausleiter J,Hoeschen C

    更新日期:2007-08-07 00:00:00

  • A compact and high sensitivity positron detector using dual-layer thin GSO scintillators for a small animal PET blood sampling system.

    abstract::For quantitative measurements of small animals such as mice or rats, a compact and high sensitivity continuous blood sampling detector is required because their blood sampling volume is limited. For this purpose we have developed and tested a new positron detector. The positron detector uses a pair of dual-layer thin ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/13/016

    authors: Yamamoto S,Imaizumi M,Shimosegawa E,Kanai Y,Sakamoto Y,Minato K,Shimizu K,Senda M,Hatazawa J

    更新日期:2010-07-07 00:00:00

  • Deep learning networks on chronic liver disease assessment with fine-tuning of shear wave elastography image sequences.

    abstract::Chronic liver disease (CLD) is currently one of the major causes of death worldwide. If not treated, it may lead to cirrhosis, hepatic carcinoma and death. Ultrasound (US) shear wave elastography (SWE) is a relatively new, popular, non-invasive technique among radiologists. Although many studies have been published va...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abae06

    authors: Kagadis GC,Drazinos P,Gatos I,Tsantis S,Papadimitroulas P,Spiliopoulos S,Karnabatidis D,Theotokas I,Zoumpoulis P,Hazle JD

    更新日期:2020-11-05 00:00:00

  • A preclinical simulated dataset of S-values and investigation of the impact of rescaled organ masses using the MOBY phantom.

    abstract::Nuclear medicine and radiation therapy, although well established, are still rapidly evolving, by exploiting animal models, aiming to define precise dosimetry in molecular imaging protocols. The purpose of the present study was to create a dataset based on the MOBY phantom for the calculation of organ-to-organ S-value...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/6/2333

    authors: Kostou T,Papadimitroulas P,Loudos G,Kagadis GC

    更新日期:2016-03-21 00:00:00

  • Characterization of the secondary neutron field produced during treatment of an anthropomorphic phantom with x-rays, protons and carbon ions.

    abstract::Short- and long-term side effects following the treatment of cancer with radiation are strongly related to the amount of dose deposited to the healthy tissue surrounding the tumor. The characterization of the radiation field outside the planned target volume is the first step for estimating health risks, such as devel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/8/2111

    authors: Tessa CL,Berger T,Kaderka R,Schardt D,Burmeister S,Labrenz J,Reitz G,Durante M

    更新日期:2014-04-21 00:00:00

  • Monitor unit calculation on the beam axis of open and wedged asymmetric high-energy photon beams.

    abstract::An ESTRO booklet and a report of the Netherlands Commission on Radiation Dosimetry have been published recently describing empirical methods for monitor unit (MU) calculations in symmetrical high-energy photon beams. Both documents support the same basic ideas; firstly the separation of head scatter and volume scatter...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/12/310

    authors: Georg D

    更新日期:1999-12-01 00:00:00

  • Evaluation of deformable image registration and a motion model in CT images with limited features.

    abstract::Deformable image registration (DIR) is increasingly used in radiotherapy applications and provides the basis for a previously described model of patient-specific respiratory motion. We examine the accuracy of a DIR algorithm and a motion model with respiration-correlated CT (RCCT) images of software phantom with known...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2539

    authors: Liu F,Hu Y,Zhang Q,Kincaid R,Goodman KA,Mageras GS

    更新日期:2012-05-07 00:00:00

  • 4D image reconstruction for emission tomography.

    abstract::An overview of the theory of 4D image reconstruction for emission tomography is given along with a review of the current state of the art, covering both positron emission tomography and single photon emission computed tomography (SPECT). By viewing 4D image reconstruction as a matter of either linear or non-linear par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/22/R371

    authors: Reader AJ,Verhaeghe J

    更新日期:2014-11-21 00:00:00

  • Review of photon interaction cross section data in the medical and biological context.

    abstract::The probability of a photon (x-ray, gamma-ray, bremsstrahlung, etc) of a given energy E undergoing absorption or scattering when traversing a layer of material Z can be expressed quantitatively in terms of a linear attenuation coefficient mu (cm(-1)). Since mu is dependent on the material's density, rho (g cm(-3)), wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/44/1/001

    authors: Hubbell JH

    更新日期:1999-01-01 00:00:00

  • Determination of fractional flow reserve (FFR) based on scaling laws: a simulation study.

    abstract::Fractional flow reserve (FFR) provides an objective physiological evaluation of stenosis severity. A technique that can measure FFR using only angiographic images would be a valuable tool in the cardiac catheterization laboratory. To perform this, the diseased blood flow can be measured with a first pass distribution ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/14/017

    authors: Wong JT,Molloi S

    更新日期:2008-07-21 00:00:00

  • Tumour oxygen dynamics measured simultaneously by near-infrared spectroscopy and 19F magnetic resonance imaging in rats.

    abstract::Simultaneous near-infrared spectroscopy (NIRS) and magnetic resonance imaging (MRI) were used to investigate the correlation between tumour vascular oxygenation and tissue oxygen tension dynamics in rat breast 13762NF tumours with respect to hyperoxic gas breathing. NIRS directly detected global variations in the oxyg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/1/004

    authors: Xia M,Kodibagkar V,Liu H,Mason RP

    更新日期:2006-01-07 00:00:00

  • Haemodynamic resistance model of monochorionic twin pregnancies complicated by acardiac twinning.

    abstract::An acardiac twin is a severely malformed monochorionic twin fetus that lacks most organs, particularly a heart. It grows during pregnancy, because it is perfused by its developmentally normal co-twin (called the pump twin) via a set of placental arterioarterial and venovenous anastomoses. The pump twin dies intrauteri...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/14/n01

    authors: Umur A,van Gemert MJ,van den Wijngaard JP,Ross MG,Nikkels PG

    更新日期:2004-07-21 00:00:00

  • The energy-dependent electron loss model for pencil beam dose kernels.

    abstract::The 'monoenergetic' electron loss model was derived in a previous work to account for pathlength straggling in the Fermi-Eyges pencil beam problem. In this paper, we extend this model to account for energy-loss straggling and secondary knock-on electron transport in order to adequately predict a depth dose curve. To m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/10/313

    authors: Chvetsov AV,Sandison GA,Yeboah C

    更新日期:2000-10-01 00:00:00

  • The feasibility of using poroelastographic techniques for distinguishing between normal and lymphedematous tissues in vivo.

    abstract::Lymphedema is a common condition involving an abnormal accumulation of lymphatic fluid in the interstitial space that causes swelling, most often in the arm(s) and leg(s). Lymphedema is a significant lifelong concern that can be congenital or develop following cancer treatment or cancer metastasis. Common methods of e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/21/013

    authors: Righetti R,Garra BS,Mobbs LM,Kraemer-Chant CM,Ophir J,Krouskop TA

    更新日期:2007-11-07 00:00:00

  • Terahertz near-field imaging.

    abstract::A near-field probe is described that enables high spatial resolution imaging with terahertz (THz) pulses. The spatial resolution capabilities of the system lie in the range of few microns and we demonstrate a resolution of 7 microm using broad-banded THz pulses with an intensity maximum near 0.5 THz. We present a stud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/21/308

    authors: Federici JF,Mitrofanov O,Lee M,Hsu JW,Brener I,Harel R,Wynn JD,Pfeiffer LN,West KW

    更新日期:2002-11-07 00:00:00

  • Prototyping a large field size IORT applicator for a mobile linear accelerator.

    abstract::The treatment of large tumors such as sarcomas with intra-operative radiotherapy using a Mobetron is often complicated because of the limited field size of the primary collimator and the available applicators (max Ø100 mm). To circumvent this limitation a prototype rectangular applicator of 80 x 150 mm(2) was designed...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/8/006

    authors: Janssen RW,Faddegon BA,Dries WJ

    更新日期:2008-04-21 00:00:00

  • An FDK-like cone-beam SPECT reconstruction algorithm for non-uniform attenuated projections acquired using a circular trajectory.

    abstract::In this paper, Novikov's inversion formula of the attenuated two-dimensional (2D) Radon transform is applied to the reconstruction of attenuated fan-beam projections acquired with equal detector spacing and of attenuated cone-beam projections acquired with a flat planar detector and circular trajectory. The derivation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/10/010

    authors: Huang Q,Zeng GL,You J,Gullberg GT

    更新日期:2005-05-21 00:00:00

  • Correlation between human and model observer performance for discrimination task in CT.

    abstract::Although physical metrics can objectively characterize computed tomography (CT) image quality, quantitative approaches to predict human observer performance are more accurate and clinically relevant. This study compared a modified channelized Hotelling model observer (CHO) with human observers in a shape discriminatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/13/3389

    authors: Zhang Y,Leng S,Yu L,Carter RE,McCollough CH

    更新日期:2014-07-07 00:00:00

  • A robust optimization method for weighted-layer-stacking proton beam therapy.

    abstract::The layer-stacking method can provide three-dimensional conformal dose distributions to the target based on a passive scattering method using mini-spread-out Bragg peak (SOBP). The purpose of this work is to demonstrate the effectiveness of a new weight optimization algorithm that can enhance the robustness of dose di...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9efd

    authors: Sakamoto Y,Maeda Y,Yamada Y,Ikeda M,Tameshige Y,Sasaki M,Shibata S,Yamamoto K

    更新日期:2020-09-28 00:00:00

  • Posture-specific phantoms representing female and male adults in Monte Carlo-based simulations for radiological protection.

    abstract::Does the posture of a patient have an effect on the organ and tissue absorbed doses caused by x-ray examinations? This study aims to find the answer to this question, based on Monte Carlo (MC) simulations of commonly performed x-ray examinations using adult phantoms modelled to represent humans in standing as well as ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/15/014

    authors: Cassola VF,Kramer R,Brayner C,Khoury HJ

    更新日期:2010-08-07 00:00:00

  • Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator.

    abstract::A new component module (CM), designated DYNVMLC, was developed to fully model the geometry of the Varian Millennium 120 leaf collimator using the BEAMnrc Monte Carlo code. The model includes details such as the leaf driving screw hole, support railing groove and leaf tips. Further modifications also allow sampling of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/004

    authors: Heath E,Seuntjens J

    更新日期:2003-12-21 00:00:00