Abstract:
:In electron beam dosimetry using parallel-plate chambers solid phantoms are sometimes necessary. To obtain the dose to water from the ionization obtained in the solid phantom, fluence correction factors and perturbation factors have to be applied. In this study fluence factors in a perturbation free geometry have been determined experimentally for common phantom materials. Wall perturbation factors for simulated Attix, NACP, and Roos chambers have also been determined for the same materials. Comparative Monte Carlo calculations have been performed using the EGS4 Monte Carlo code. Comparison with data in newly published protocols such as IAEA and IPEMB shows an agreement with the results obtained in this paper to within 1%, demonstrating that the data published in these protocols may be used with reasonable accuracy if recommended phantoms are used. The results also show that if unsuitable phantom materials are used, the wall perturbation factors may differ for different chambers and for different phantom materials by more than 3% and perturbation factors have to be considered in order to obtain a high accuracy in the dose determination.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Nilsson B,Montelius A,Andreo P,Johansson Jdoi
10.1088/0031-9155/42/11/007subject
Has Abstractpub_date
1997-11-01 00:00:00pages
2101-18issue
11eissn
0031-9155issn
1361-6560journal_volume
42pub_type
杂志文章abstract::We propose a regularized least-squares method for reconstructing 2D velocity vector fields within the left ventricular cavity from single-view color Doppler echocardiographic images. Vector flow mapping is formulated as a quadratic optimization problem based on an [Formula: see text]-norm minimization of a cost functi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa7fe7
更新日期:2017-08-11 00:00:00
abstract::At the UMC Utrecht a prototype MR-linac has been installed. The system consists of an 8 MV Elekta linear accelerator and a 1.5 T Philips MRI system. This paper investigates the performance of the IC PROFILER™, a multi-axis ionization chamber array, in a 1.5 T magnetic field. The influence of the magnetic field on the ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/7/1845
更新日期:2014-04-07 00:00:00
abstract::The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/15/003
更新日期:2005-08-07 00:00:00
abstract::An open-ended coaxial probe is often used for investigating the dielectric properties of biological tissues. The present study indicates that in addition to the probe size, the penetration of the electromagnetic (EM) fields of an open-ended coaxial probe in contact with the skin is dependent on the applied frequency b...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/7/404
更新日期:1999-07-01 00:00:00
abstract::Most existing spatiotemporal multi-dipole approaches for MEG/EEG source localization assume that the dipoles are active for the full time range being analysed. If the actual time range of activity of sources is significantly shorter than the time range being analysed, the detectability, localization and time-course de...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/10/004
更新日期:2006-05-21 00:00:00
abstract::Brain stereotactic radiosurgery (SRS) treatments require multiple quality assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear accelerator is crucial. In this study, a novel...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab8534
更新日期:2020-06-10 00:00:00
abstract::Gel dosimetry based on magnetic resonance imaging (MRI) has previously been shown to provide verification of calculated dose distributions in soft tissue equivalent homogeneous phantoms. This study demonstrates how measurements of dose distribution can also be achieved in a phantom containing porous, lung-equivalent, ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/10/303
更新日期:2000-10-01 00:00:00
abstract::The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead o...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/11/002
更新日期:2011-06-07 00:00:00
abstract::The UK, European and IAEA protocols for breast dosimetry in mammography use tabulations of conversion factors, which relate measurements of incident air kerma to the mean glandular dose to the breast. To supplement the existing tabulations, a Monte Carlo computer program has been used to calculate conversion factors f...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/9/2127
更新日期:2014-05-07 00:00:00
abstract::The aim of this work was to evaluate the accuracy of dose predicted in heterogeneous media by a pencil beam (PB), a collapsed cone (CC) and a Monte Carlo (MC) algorithm. For this purpose, a simple multi-layer phantom composed of Styrofoam and white polystyrene was irradiated with 10 x 10 cm2 as well as 20 x 20 cm2 ope...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/5/010
更新日期:2005-03-07 00:00:00
abstract::In modern radiotherapy, it is vitally important to monitor the performance of all linac components including the collimation system. In this study, a simple measurement method and accurate algorithm are introduced for investigation of the secondary and tertiary collimator sag during radiotherapy arc treatments. The me...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/12/N209
更新日期:2012-06-21 00:00:00
abstract:PURPOSE:A system for long-length intraoperative imaging is reported based on longitudinal motion of an O-arm gantry featuring a multi-slot collimator. We assess the utility of long-length tomosynthesis and the geometric accuracy of 3D image registration for surgical guidance and evaluation of long spinal constructs. M...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abde96
更新日期:2021-01-21 00:00:00
abstract::We show how the spectral imaging framework should be modified to account for a high fraction of Compton interactions in low Z detector materials such as silicon. Using this framework, where deposited energies differ from actual photon energies, we compare the performance of a silicon strip detector, including the infl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/7/014
更新日期:2010-04-07 00:00:00
abstract::The aim of the study is to determine PTV margin for inter-observer variability in the volumetric modulated arc therapy (VMAT) prostate radiotherapy with high-dose volumetric CT (HDVCT) and conventional helical CT (CCT) for planning. Secondly to investigate the impact of geometric (PTV expansion) and dosimetric (confor...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab050f
更新日期:2019-03-14 00:00:00
abstract::We investigate the effect of multiple scattering on the optical coherence tomography (OCT) signal and the Doppler OCT signal of flowing blood. Doppler OCT measurements at 1300 nm are performed on flowing diluted porcine blood with hematocrit ranging between 0% and 15%. Measured blood hematocrit and mean red blood cell...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/7/1907
更新日期:2012-04-07 00:00:00
abstract::A micro-multileaf collimator (microMLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the microMLC does not allow 'direct'...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/15/305
更新日期:2003-08-07 00:00:00
abstract::Planning of radiotherapy is often difficult due to restrictions on morphological images. New imaging techniques enable the integration of biological information into treatment planning and help to improve the detection of vital and aggressive tumour areas. This might improve clinical outcome. However, nowadays morphol...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/17/020
更新日期:2005-09-07 00:00:00
abstract::Many of the inadequacies of the system presently used for surveying environments containing penetrating radiation stem from the impossibility of defining a radiation parameter which is additive, measurable and closely related to peak dose equivalent in the body. Many of the present conceptual difficulties would be eli...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/20/6/012
更新日期:1975-11-01 00:00:00
abstract::Complex intra-fractional motion and deformation of the liver significantly impacts the accuracy of delivered dose in radiotherapy. It limits margin reduction, dose escalation and normal tissue sparing. A critical component of motion management is to accurately reconstruct tumor motion. In this study, we developed a si...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab4c0d
更新日期:2019-11-21 00:00:00
abstract::Earlier work on the dielectric properties of cryoprotectant agents is extended using a modified measuring cell and method of data reduction yielding results more efficiently over a temperature range from -75 to +25 degrees C at frequencies from 27 MHz to 3 GHz. Dimethyl sulphoxide and butanediol are investigated at lo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/10/011
更新日期:1998-10-01 00:00:00
abstract::Input functions required for positron emission tomography (PET) tracer kinetic modeling are often obtained from arterial blood. In some situations, using short-lived radiotracers, e.g. [(15)O]water, rapid sample handling is required. A method used at several facilities is to pump blood through a detector system at a c...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/2/003
更新日期:2008-01-21 00:00:00
abstract::Prenatal events such as intrauterine growth restriction and increased cardiovascular risk in later life have been shown to be associated with an increased intima-media thickness (aIMT) of the abdominal aorta in the fetus. In order to assess and manage atherosclerosis and cardiovascular disease risk in adults and child...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0022-3727/59/21/6355
更新日期:2014-11-07 00:00:00
abstract::Recent studies of the minute morphology of the skin by optical coherence tomography revealed that the sweat ducts in human skin are helically shaped tubes, filled with a conductive aqueous solution. This, together with the fact that the dielectric permittivity of the dermis is higher than that of the epidermis, brings...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/11/005
更新日期:2009-06-07 00:00:00
abstract::Curves relating beam energy, scattering foil thickness, central-axis depth-dose, and beam flatness have been generated using data taken on a Siemens 200A betatron. The curve set allows a single combination of tungsten foil thickness and electron beam energy to be chosen that will provide the optimum depth-dose distrib...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/26/3/007
更新日期:1981-05-01 00:00:00
abstract::In recent years there has been a large amount of research into the potential use of radiation sensitive gels for three-dimensional verification of clinical radiotherapy doses. In this paper we report the use of a MAGIC gel dosimeter (Fong et al 2001 Phys. Med. Biol. 46 3105) for the verification of a specific patient'...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/9/003
更新日期:2004-05-07 00:00:00
abstract::In positron emission tomography (PET), there is an increasing interest in studying not only the regional mean tracer concentration, but its variation arising from local differences in physiology, the tissue heterogeneity. However, in reconstructed images this physiological variation is shadowed by a large reconstructi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/14/4849
更新日期:2013-07-21 00:00:00
abstract::Enabling automated pipelines, image analysis and big data methodology in cancer clinics requires thorough understanding of the data. Automated quality assurance steps could improve the efficiency and robustness of these methods by verifying possible data biases. In particular, in head and neck (H&N) computed-tomograph...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab5427
更新日期:2020-01-10 00:00:00
abstract::Image-guided radiation therapy using implanted fiducial markers is a common solution for prostate localization to improve targeting accuracy. However, fiducials that are typically used for conventional photon radiotherapy cause large dose perturbations in patients who receive proton radiotherapy. A proposed solution h...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/23/S13
更新日期:2010-12-07 00:00:00
abstract::The variety of treatment options for cancer patients has increased significantly in recent years. Not only do we combine radiation with surgery and chemotherapy, new therapeutic approaches such as immunotherapy and targeted therapies are starting to play a bigger role. Physics has made significant contributions to rad...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/21/R344
更新日期:2016-11-07 00:00:00
abstract::A Geiger-mode avalanche photodiode (Si-PM) is a promising photodetector for PET, especially for use in a magnetic resonance imaging (MRI) system, because it has high gain and is less sensitive to a static magnetic field. We developed a Si-PM-based depth-of-interaction (DOI) PET system for small animals. Hamamatsu 4 × ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/19/013
更新日期:2010-10-07 00:00:00