Estimation of prenatal aorta intima-media thickness from ultrasound examination.

Abstract:

:Prenatal events such as intrauterine growth restriction and increased cardiovascular risk in later life have been shown to be associated with an increased intima-media thickness (aIMT) of the abdominal aorta in the fetus. In order to assess and manage atherosclerosis and cardiovascular disease risk in adults and children, in recent years the measurement of abdominal and carotid artery thickness has gained a growing appeal. Nevertheless, no computer aided method has been proposed for the analysis of prenatal vessels from ultrasound data, yet. To date, these measurements are being performed manually on ultrasound fetal images by skilled practitioners. The aim of the presented study is to introduce an automatic algorithm that identifies abdominal aorta and estimates its diameter and aIMT from routine third trimester ultrasonographic fetal data.The algorithm locates the aorta, then segments it and, by modeling the arterial wall longitudinal sections by means of a gaussian mixture, derives a set of measures of the aorta diameter (aDiam) and of the intima-media thickness (aIMT). After estimating the cardiac cycle, the mean diameter and the aIMT at the end-diastole phase are computed.Considering the aIMT value for each subject, the correlation between automatic and manual end-diastolic aIMT measurements is 0.91 in a range of values 0.44-1.10 mm, corresponding to both normal and pathological conditions. The automatic system yields a mean relative error of 19%, that is similar to the intra-observer variability (14%) and much lower that the inter-observer variability (42%).The correlation between manual and automatic measurements and the small error confirm the ability of the proposed system to reliably estimate aIMT values in prenatal ultrasound sequences, reducing measurement variability and suggesting that it can be used for an automatic assessment of aIMT.

journal_name

Phys Med Biol

authors

Veronese E,Tarroni G,Visentin S,Cosmi E,Linguraru MG,Grisan E

doi

10.1088/0022-3727/59/21/6355

subject

Has Abstract

pub_date

2014-11-07 00:00:00

pages

6355-71

issue

21

eissn

0031-9155

issn

1361-6560

journal_volume

59

pub_type

杂志文章
  • Segmented attenuation correction using artificial neural networks in positron tomography.

    abstract::The measured attenuation correction technique is widely used in cardiac positron tomographic studies. However, the success of this technique is limited because of insufficient counting statistics achievable in practical transmission scan times, and of the scattered radiation in transmission measurement which leads to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/10/024

    authors: Yu SK,Nahmias C

    更新日期:1996-10-01 00:00:00

  • A robust procedure for verifying TomoTherapy Hi-Art™ source models for small fields.

    abstract::The dosimetric measurement and modeling of small radiation treatment fields (<2 × 2 cm2) are difficult to perform and prone to error. Measurements of small fields are often adversely influenced by the properties of the detectors used to make them. The dosimetric properties of small fields have been difficult to accura...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/12/015

    authors: Hundertmark B,Sterpin E,Mackie T

    更新日期:2011-06-21 00:00:00

  • Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy.

    abstract::The combined build-up and attenuation factor, B exp (-mu r), of point isotropic photon sources in a water medium has been calculated using the Monte Carlo method, for energies (20-1500 keV) and distances (1-10 cm) relevant in brachytherapy. For the transport of photons and electrons, up-to-date and self-consistent tot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/005

    authors: Angelopoulos A,Perris A,Sakellariou K,Sakelliou L,Sarigiannis K,Zarris G

    更新日期:1991-06-01 00:00:00

  • Effect of dominant features on neural network performance in the classification of mammographic lesions.

    abstract::Two different classifiers, an artificial neural network (ANN) and a hybrid system (one step rule-based method followed by an artificial neural network) have been investigated to merge computer-extracted features in the task of differentiating between malignant and benign masses. A database consisting of 65 cases (38 m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/10/315

    authors: Huo Z,Giger ML,Metz CE

    更新日期:1999-10-01 00:00:00

  • The role of trapped bubbles in kidney stone detection with the color Doppler ultrasound twinkling artifact.

    abstract::The color Doppler ultrasound twinkling artifact, which highlights kidney stones with rapidly changing color, has the potential to improve stone detection; however, its inconsistent appearance has limited its clinical utility. Recently, it was proposed stable crevice bubbles on the kidney stone surface cause twinkling;...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9a2f

    authors: Simon JC,Sapozhnikov OA,Kreider W,Breshock M,Williams JC,Bailey MR

    更新日期:2018-01-09 00:00:00

  • Analytical propagation of errors in dynamic SPECT: estimators, degrading factors, bias and noise.

    abstract::Dynamic SPECT is a relatively new technique that may potentially benefit many imaging applications. Though similar to dynamic PET, the accuracy and precision of dynamic SPECT parameter estimates are degraded by factors that differ from those encountered in PET. In this work we formulate a methodology for analytically ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/8/311

    authors: Kadrmas DJ,DiBella EV,Huesman RH,Gullberg GT

    更新日期:1999-08-01 00:00:00

  • Real-time prediction and gating of respiratory motion using an extended Kalman filter and Gaussian process regression.

    abstract::Motion-adaptive radiotherapy aims to deliver a conformal dose to the target tumour with minimal normal tissue exposure by compensating for tumour motion in real time. The prediction as well as the gating of respiratory motion have received much attention over the last two decades for reducing the targeting error of th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/1/233

    authors: Bukhari W,Hong SM

    更新日期:2015-01-07 00:00:00

  • Absorbed dose determination at short distance from 60Co and 192Ir brachytherapy sources.

    abstract::This paper presents two methods for absorbed dose determination with ionization chambers at short distance from 60Co and 192Ir brachytherapy sources. The methods are modifications of the Bragg-Gray and large cavity principles given in the IAEA code of practice for high- and medium-energy photon beams. A non-uniformity...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/11/002

    authors: Tölli H,Johansson KA

    更新日期:1998-11-01 00:00:00

  • Influence of vascular normalization on interstitial flow and delivery of liposomes in tumors.

    abstract::Elevated interstitial fluid pressure is one of the barriers of drug delivery in solid tumors. Recent studies have shown that normalization of tumor vasculature by anti-angiogenic factors may improve the delivery of conventional cytotoxic drugs, possibly by increasing blood flow, decreasing interstitial fluid pressure,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/4/1477

    authors: Ozturk D,Yonucu S,Yilmaz D,Unlu MB

    更新日期:2015-02-21 00:00:00

  • Medical staff extremity dosimetry in CT fluoroscopy: an anthropomorphic hand voxel phantom study.

    abstract::This work aims to contribute to the study of the radiation dose distribution delivered to the hands of medical staff members during a general computed tomographic (CT) fluoroscopic guided procedure. In this study, both Monte Carlo simulations and measurements were performed. For free-in-air and computed tomography dos...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/16/5433

    authors: Figueira C,Becker F,Blunck C,DiMaria S,Baptista M,Esteves B,Paulo G,Santos J,Teles P,Vaz P

    更新日期:2013-08-21 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • PBS machine interlocks using EWMA.

    abstract::Delivery of pencil beam scanning (PBS) requires the on-line measurement of several beam parameters. If the measurement is outside of specified tolerances and a binary threshold algorithm is used, the beam will be paused. Given instrumentation and statistical noise such a system can lead to many pauses which could incr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/400

    authors: Clasie BM,Kooy HM,Flanz JB

    更新日期:2016-01-07 00:00:00

  • Metal artifact reduction method based on a constrained beam-hardening estimator for polychromatic x-ray CT.

    abstract::Beam hardening is inevitable due to the polychromatic X-ray spectrum and energy-dependent attenuation coefficients of materials, leading to the underestimation of artifacts arising from projection data, especially on metal regions. State-of-the-art research on beam-hardening artifacts is based on a numerical method th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe026

    authors: Hur J,Kim D,Shin YG,Lee H

    更新日期:2021-01-26 00:00:00

  • Experimental pencil beam kernels derivation for 3D dose calculation in flattening filter free modulated fields.

    abstract::This paper presents a method to obtain the pencil-beam kernels that characterize a megavoltage photon beam generated in a flattening filter free (FFF) linear accelerator (linac) by deconvolution from experimental measurements at different depths. The formalism is applied to perform independent dose calculations in mod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/50

    authors: Azcona JD,Barbés B,Wang L,Burguete J

    更新日期:2016-01-07 00:00:00

  • Relative determination of W-values for alpha particles in tissue-equivalent and other gases.

    abstract::W (the average energy to form an ion pair) for 5.4 MeV 241Am alpha particles in a Rossi-type tissue-equivalent (TE) gas, argon and methane was determined to an accuracy better than 0.2% using a new automated data handling system. A vibrating reed electrometer and current digitiser were used to measure the current prod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/005

    authors: Krieger GL,Baum JW,Varma MN,Beach JL

    更新日期:1979-03-01 00:00:00

  • Why should breast tumour detection go three dimensional?

    abstract::Although x-ray mammography is widely developed for breast tumour detection, it suffers from spatial superposition in its two-dimensional (2D) representation of a three-dimensional (3D) breast structure. Accordingly, 3D breast imaging, such as cone-beam computed tomography (CT), arises at the historic moment. In this p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/14/312

    authors: Chen Z,Ning R

    更新日期:2003-07-21 00:00:00

  • Truncation artifact suppression in cone-beam radionuclide transmission CT using maximum likelihood techniques: evaluation with human subjects.

    abstract::Transverse image truncation can be a serious problem for human imaging using cone-beam transmission CT (CB-CT) implemented on a conventional rotating gamma camera. If this problem can be solved, CB-CT will be useful for attenuation compensation of SPECT images. This paper presents a reconstruction method to reduce or ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/3/004

    authors: Manglos SH

    更新日期:1992-03-01 00:00:00

  • Real-time tracking of tumor motions and deformations along the leaf travel direction with the aid of a synchronized dynamic MLC leaf sequencer.

    abstract::Advanced radiotherapeutical techniques like intensity-modulated radiation therapy (IMRT) are based on an accurate knowledge of the location of the radiation target. An accurate dose delivery, therefore, requires a method to account for the inter- and intrafractional target motion and the target deformation occurring d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/22/N01

    authors: Tacke M,Nill S,Oelfke U

    更新日期:2007-11-21 00:00:00

  • Investigation of patient, tumour and treatment variables affecting residual motion for respiratory-gated radiotherapy.

    abstract::Respiratory gating can reduce the apparent respiratory motion during imaging and treatment; however, residual motion within the gating window remains. Respiratory training can improve respiratory reproducibility and, therefore, the efficacy of respiratory-gated radiotherapy. This study was conducted to determine wheth...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/20/015

    authors: George R,Ramakrishnan V,Siebers JV,Chung TD,Keall PJ

    更新日期:2006-10-21 00:00:00

  • Kill painting of hypoxic tumors with multiple ion beams.

    abstract::We report on a novel method for simultaneous biological optimization of treatment plans for hypoxic tumors using multiple ion species. Our previously introduced kill painting approach, where the overall cell killing is optimized on biologically heterogeneous targets, was expanded with the capability of handling differ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafe40

    authors: Sokol O,Krämer M,Hild S,Durante M,Scifoni E

    更新日期:2019-02-08 00:00:00

  • Multi-isotope SPECT imaging of the 225Ac decay chain: feasibility studies.

    abstract::Effective use of the [Formula: see text] decay chain in targeted internal radioimmunotherapy requires the retention of both [Formula: see text] and progeny isotopes at the target site. Imaging-based pharmacokinetic tests of these pharmaceuticals must therefore separately yet simultaneously image multiple isotopes that...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6a99

    authors: Robertson AKH,Ramogida CF,Rodríguez-Rodríguez C,Blinder S,Kunz P,Sossi V,Schaffer P

    更新日期:2017-06-07 00:00:00

  • Experimental verification of a model for predicting transient temperature distributions by focused ultrasound.

    abstract::A thermal model for predicting time-dependent temperature distributions during ultrasound heating was tested quantitatively. The relevant thermal processes incorporated in the model are heat conduction and ultrasound power absorption, and the required input parameters include the absolute ultrasound power, the shape a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/9/001

    authors: Chin RB,Zagzebski JA,Madsen EL

    更新日期:1991-09-01 00:00:00

  • Spectra from 2.5-15 microm of tissue phantom materials, optical clearing agents and ex vivo human skin: implications for depth profiling of human skin.

    abstract::Infrared measurements have been used to profile or image biological tissue, including human skin. Usually, analysis of such measurements has assumed that infrared absorption is due to water and collagen. Such an assumption may be reasonable for soft tissue, but introduction of exogenous agents into skin or the measure...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/2/402

    authors: Viator JA,Choi B,Peavy GM,Kimel S,Nelson JS

    更新日期:2003-01-21 00:00:00

  • Medical personnel and patient dosimetry during coronary angiography and intervention.

    abstract::Percutaneous coronary interventions are associated with increased radiation exposure compared to most radiological examinations. This prospective study aimed at (1) measuring entrance doses for all in-room personnel, (2) performing an assessment of patient effective dose and intracoronary doses, (3) investigating the ...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/48/18/307

    authors: Efstathopoulos EP,Makrygiannis SS,Kottou S,Karvouni E,Giazitzoglou E,Korovesis S,Tzanalaridou E,Raptou PD,Katritsis DG

    更新日期:2003-09-21 00:00:00

  • Direct aperture optimization for a variable aperture collimator for intensity-modulated radiation therapy.

    abstract::In this note a technique is described for direct aperture optimization of components deliverable by a variable aperture collimator (VAC) for intensity-modulated radiation therapy. The first key result found was that, provided a large number of VAC components were selected for optimization, the resulting fluence profil...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/5/n02

    authors: Webb S

    更新日期:2004-03-07 00:00:00

  • On differences in radiosensitivity estimation: TCP experiments versus survival curves. A theoretical study.

    abstract::We have compared two methods of estimating the cellular radiosensitivity of a heterogeneous tumour, namely, via cell-survival and via tumour control probability (TCP) pseudo-experiments. It is assumed that there exists intra-tumour variability in radiosensitivity and that the tumour consists predominantly of radiosens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/15/N293

    authors: Stavrev P,Stavreva N,Ruggieri R,Nahum A

    更新日期:2015-08-07 00:00:00

  • Monte Carlo and water calorimetric determination of kilovoltage beam radiotherapy ionization chamber correction factors.

    abstract::The in-phantom calibration method for radiotherapy kilovoltage x-ray beams requires ionization chamber correction factors. The overall ionization chamber correction factor accounts for changes in the chamber response due to the displacement of water by the chamber cavity and wall, the presence of the stem and the chan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab82e7

    authors: Bancheri J,Ketelhut S,Büermann L,Seuntjens J

    更新日期:2020-05-11 00:00:00

  • Towards using a focussed phased array of millimetre length scale elements for ultrasound imaging.

    abstract::Sparse phased array ultrasound transducers with millimetre length scale elements have previously been proposed for generating hyperthermia but not for imaging. Numerical simulation with a pseudospectral solver was used to investigate: (a) how the position of the maximum pressure in the focal region changed with elemen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aace07

    authors: Wilson AJ

    更新日期:2018-07-16 00:00:00

  • Robust principal component analysis-based four-dimensional computed tomography.

    abstract::The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/11/002

    authors: Gao H,Cai JF,Shen Z,Zhao H

    更新日期:2011-06-07 00:00:00

  • Characteristics of boron-dose enhancer dependent on dose protocol and 10B concentration for BNCT using near-threshold 7Li(p,n)7Be direct neutrons.

    abstract::The dependence of boron-dose enhancer (BDE) characteristics on dose protocol and 10B concentration was evaluated for BNCT using near-threshold 7Li(p,n)7Be direct neutrons. The treatable protocol depth (TPD) was utilized as an evaluation index. MCNP calculations were performed for near-threshold 7Li(p,n)7Be at a proton...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/1/013

    authors: Tanaka K,Kobayashi T,Bengua G,Nakagawa Y,Endo S,Hoshi M