Radiofrequency heating effects around resonant lengths of wire in MRI.

Abstract:

:Several recent reports agree that the potentially dangerous heating around extended wires or coaxial cables inside the bodycoil of a magnetic resonance imager is related to resonant effects. No quantitative description of this idea has been given so far. We analyse a simplified situation, where a straight metallic wire is completely surrounded by a large volume of homogeneous dielectric with a small conductivity. If it has the correct length, the wire acts as a receiving-and-retransmission antenna, changing the axial symmetry of the incoming electric field into a radially outgoing electric field near the wire ends. The latter field points into the conducting surroundings, causing dissipation. Some simple experiments on geometries related to this theoretical model provide support to the main conclusions. These suggest that under actual imaging conditions resonant effects might be avoided by choosing a wire length of about 2 m. However, more experimental work remains to be done to validate this suggestion.

journal_name

Phys Med Biol

authors

Pictet J,Meuli R,Wicky S,van der Klink JJ

doi

10.1088/0031-9155/47/16/312

subject

Has Abstract

pub_date

2002-08-21 00:00:00

pages

2973-85

issue

16

eissn

0031-9155

issn

1361-6560

journal_volume

47

pub_type

杂志文章
  • Soft-tissue phase-contrast tomography with an x-ray tube source.

    abstract::We report the first experimental soft-tissue phase-contrast tomography results using a conventional x-ray tube source, with a millimeter-sized focal spot. The setup is based on a Talbot-Lau grating interferometer operated at a mean energy of 28 keV. We present three-dimensional ex vivo images of a chicken heart sample...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/010

    authors: Bech M,Jensen TH,Feidenhans'l R,Bunk O,David C,Pfeiffer F

    更新日期:2009-05-07 00:00:00

  • NEMA NU 4-2008 validation and applications of the PET-SORTEO Monte Carlo simulations platform for the geometry of the Inveon PET preclinical scanner.

    abstract::Monte Carlo-based simulation of positron emission tomography (PET) data plays a key role in the design and optimization of data correction and processing methods. Our first aim was to adapt and configure the PET-SORTEO Monte Carlo simulation program for the geometry of the widely distributed Inveon PET preclinical sca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/19/6749

    authors: Boisson F,Wimberley CJ,Lehnert W,Zahra D,Pham T,Perkins G,Hamze H,Gregoire MC,Reilhac A

    更新日期:2013-10-07 00:00:00

  • Investigation of practical approaches to evaluating cumulative dose for cone beam computed tomography (CBCT) from standard CT dosimetry measurements: a Monte Carlo study.

    abstract::A function called Gx(L) was introduced by the International Commission on Radiation Units and Measurements (ICRU) Report-87 to facilitate measurement of cumulative dose for CT scans within long phantoms as recommended by the American Association of Physicists in Medicine (AAPM) TG-111. The Gx(L) function is equal to t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/14/5413

    authors: Abuhaimed A,Martin CJ,Sankaralingam M,Gentle DJ

    更新日期:2015-07-21 00:00:00

  • Characterization of diffraction-enhanced imaging contrast in breast cancer.

    abstract::Diffraction-enhanced imaging (DEI) is a new x-ray imaging modality that has been shown to enhance contrast between normal and cancerous breast tissues. In this study, diffraction-enhanced imaging in computed tomography (DEI-CT) mode was used to quantitatively characterize the refraction contrasts of the organized stru...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/019

    authors: Kao T,Connor D,Dilmanian FA,Faulconer L,Liu T,Parham C,Pisano ED,Zhong Z

    更新日期:2009-05-21 00:00:00

  • Influence of the SURLAS applicator on radiation dose distributions during simultaneous thermoradiotherapy with helical tomotherapy.

    abstract::Simultaneous thermoradiotherapy has been shown to maximize the effect of hyperthermia as a radiation sensitizer in cancer treatment. Here we follow our previous work on feasibility of thermoradiotherapy with the scanning ultrasound reflector linear array system (SURLAS) and TomoTherapy HiArt treatment system, and inve...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/10/004

    authors: Novák P,Peñagarícano JA,Nahirnyak V,Corry P,Moros EG

    更新日期:2008-05-21 00:00:00

  • Assessment of induced radio-frequency electromagnetic fields in various anatomical human body models.

    abstract::The reference levels for testing compliance of human exposure with radio-frequency (RF) safety limits have been derived from very simplified models of the human. In order to validate these findings for anatomical models, we investigated the absorption characteristics for various anatomies ranging from 6 year old child...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/004

    authors: Kühn S,Jennings W,Christ A,Kuster N

    更新日期:2009-02-21 00:00:00

  • A modified lead attenuation method to determine the fast neutron sensitivity kU of a photon dosemeter.

    abstract::Various lead attenuation techniques to determine the fast neutron sensitivity kU of a photon dosemeter are reviewed and a modified method is proposed to determine the kU value of a commercially available Geiger--Müller detector. The dependence on the 'effective' photon energy of the gamma-component of the mixed n--gam...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/4/005

    authors: Hough JH

    更新日期:1979-07-01 00:00:00

  • The reproducibility of polyacrylamide gel dosimetry applied to stereotactic conformal radiotherapy.

    abstract::The reproducibility of polyacrylamide gel (PAG) dosimetry has been evaluated when used to verify two radiotherapy treatment plans of increasing complexity. The plans investigated were a three-field coplanar arrangement, using the linac jaws for field shaping, and a four-field, conformal, non-coplanar plan using precis...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/5/309

    authors: Cosgrove VP,Murphy PS,McJury M,Adams EJ,Warrington AP,Leach MO,Webb S

    更新日期:2000-05-01 00:00:00

  • Regularized image reconstruction with an anatomically adaptive prior for positron emission tomography.

    abstract::The incorporation of accurately aligned anatomical information as a prior to guide reconstruction and noise regularization in positron emission tomography (PET) has been suggested in many previous studies. However, the advantages of this approach can only be realized if the exact lesion outline is also available. In p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/24/009

    authors: Chan C,Fulton R,Feng DD,Meikle S

    更新日期:2009-12-21 00:00:00

  • Low-frequency conductivity tensor imaging with a single current injection using DT-MREIT.

    abstract::Diffusion tensor - magnetic resonance electrical impedance tomography (DT-MREIT) is an imaging modality to obtain low-frequency anisotropic conductivity distribution employing diffusion tensor imaging (DTI) and magnetic resonance electrical impedance tomography (MREIT) techniques. DT-MREIT is based on the linear relat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abddcf

    authors: Sadighi M,Sisman M,Acikgoz BC,Eroglu HH,Eyuboglu BM

    更新日期:2021-01-20 00:00:00

  • Determination of some parameters for pion radiobiology studies.

    abstract::An experimental investigation of the central axis depth-dose and stopping rate distribution of the SIN biomedical pion beam is reported. The pion stopping rate in a thin disc of tissue-equivalent plastic was determined using a counter telescope. The dose rate at the position of this dic 'target' was measured using a s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/3/007

    authors: Nordell B,Baarli J,Sullivan AH,Zielczynski M

    更新日期:1977-05-01 00:00:00

  • Energy-resolved computed tomography: first experimental results.

    abstract::First experimental results with energy-resolved computed tomography (CT) are reported. The contrast-to-noise ratio (CNR) in CT has been improved with x-ray energy weighting for the first time. Further, x-ray energy weighting improved the CNR in material decomposition CT when applied to CT projections prior to dual-ene...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/20/002

    authors: Shikhaliev PM

    更新日期:2008-10-21 00:00:00

  • Evaluating and comparing algorithms for respiratory motion prediction.

    abstract::In robotic radiosurgery, it is necessary to compensate for systematic latencies arising from target tracking and mechanical constraints. This compensation is usually achieved by means of an algorithm which computes the future target position. In most scientific works on respiratory motion prediction, only one or two a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/11/3911

    authors: Ernst F,Dürichen R,Schlaefer A,Schweikard A

    更新日期:2013-06-07 00:00:00

  • Understanding the limitations of ultrasonic backscatter measurements from microbubble populations.

    abstract::Despite over ten years of in vitro investigations of ultrasound contrast agents, the level of understanding of their behaviour in ultrasound fields is limited. Several problems associated with these investigations, particular to the nature of contrast agents, are discussed. Using a commercial scanner the RF normalized...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/23/313

    authors: Sboros V,Ramnarine KV,Moran CM,Pye SD,McDicken WN

    更新日期:2002-12-07 00:00:00

  • Improved correction for the tissue fraction effect in lung PET/CT imaging.

    abstract::Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this 'tissue fraction effect' (TFE). In this paper, we extend ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7387

    authors: Holman BF,Cuplov V,Millner L,Hutton BF,Maher TM,Groves AM,Thielemans K

    更新日期:2015-09-21 00:00:00

  • Improved accuracy of markerless motion tracking on bone suppression images: preliminary study for image-guided radiation therapy (IGRT).

    abstract::The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images obtained by the dual-energy subtraction technique. This study was performed to evaluate the usefulness of bone suppression image processing in image-guided radiation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/n209

    authors: Tanaka R,Sanada S,Sakuta K,Kawashima H

    更新日期:2015-05-21 00:00:00

  • Accurate helical cone-beam CT reconstruction with redundant data.

    abstract::We present a new image reconstruction algorithm for helical cone-beam computed tomography (CT). This algorithm is designed for data collected at or near maximum pitch, and provides a theoretically exact and stable reconstruction while beneficially using all measured data. The main operations involved are a differentia...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/15/001

    authors: Schöndube H,Stierstorfer K,Noo F

    更新日期:2009-08-07 00:00:00

  • Superpixel-based and boundary-sensitive convolutional neural network for automated liver segmentation.

    abstract::Segmentation of liver in abdominal computed tomography (CT) is an important step for radiation therapy planning of hepatocellular carcinoma. Practically, a fully automatic segmentation of liver remains challenging because of low soft tissue contrast between liver and its surrounding organs, and its highly deformable s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabd19

    authors: Qin W,Wu J,Han F,Yuan Y,Zhao W,Ibragimov B,Gu J,Xing L

    更新日期:2018-05-04 00:00:00

  • Evaluation of a ferrous benzoic xylenol orange transparent PVA cryogel radiochromic dosimeter.

    abstract::A stable cryogel dosimeter was prepared using ferrous benzoic xylenol orange (FBX) in a transparent poly-(vinyl alcohol) (PVA) cryogel matrix. Dose response was evaluated for different numbers of freeze-thaw cycles (FTCs), different concentrations of PVA, and ratios of water/dimethyl sulfoxide. Linear relationships be...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1773

    authors: Eyadeh MM,Farrell TJ,Diamond KR

    更新日期:2014-04-07 00:00:00

  • Estimating photon interaction coefficients from single energy x-ray CT.

    abstract::Single energy x-ray analysis is explored in the context of computed tomography (CT), whereby Hounsfield numbers (HN) are used to estimate electron density N(e) and parameters that describe composition. We examine measurements with tissue substitute materials and theoretical HN for a broad range of tissues. Results are...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/23/8079

    authors: Midgley SM

    更新日期:2012-12-07 00:00:00

  • Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS).

    abstract::In stereotactic radiosurgery, a seven-irradiation film was used to define any discrepancy between the beam and target centres. A mathematical model based on the linac alignment and target set-up was developed to diagnose the discrepancies of the seven-irradiation film between the beam and simulation target centres. Fr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/9/003

    authors: Tsai JS

    更新日期:1996-09-01 00:00:00

  • A complete distortion correction for MR images: II. Rectification of static-field inhomogeneities by similarity-based profile mapping.

    abstract::Radiotherapy treatment planning relies on the use of geometrically correct images. This paper presents a fully automatic tool for correcting MR images for the effects of B(0) inhomogeneities. The post-processing method is based on the gradient-reversal technique of Chang and Fitzpatrick (1992 IEEE Trans. Med. Imaging ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/11/014

    authors: Reinsberg SA,Doran SJ,Charles-Edwards EM,Leach MO

    更新日期:2005-06-07 00:00:00

  • Image-guidance for surgical procedures.

    abstract::Contemporary imaging modalities can now provide the surgeon with high quality three- and four-dimensional images depicting not only normal anatomy and pathology, but also vascularity and function. A key component of image-guided surgery (IGS) is the ability to register multi-modal pre-operative images to each other an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/14/R01

    authors: Peters TM

    更新日期:2006-07-21 00:00:00

  • Evaluation of the basic properties of the BANGkit gel dosimeter.

    abstract::We evaluated the basic properties of a commercially available BANGkit gel dosimeter, which is a normoxic type of BANG gel. This gel-kit has the same composition as the BANG 3 gel, but is fully oxygenated. To exclude oxygen, oxygen scavenging ascorbic acid and copper sulfate as a catalyst are used. The properties that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/8/017

    authors: Murakami Y,Nakashima T,Watanabe Y,Akimitsu T,Matsuura K,Kenjo M,Kaneyasu Y,Wadasaki K,Hirokawa Y,Ito K

    更新日期:2007-04-21 00:00:00

  • Beam angle selection incorporation of anatomical heterogeneities for pencil beam scanning charged-particle therapy.

    abstract::In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. The sensitivity of a PBS plan to lateral tissue heterogeneities can be reduced by selecting appropriate beam angles. The purpose of this study is...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8664

    authors: Toramatsu C,Inaniwa T

    更新日期:2016-12-21 00:00:00

  • Optimizing functional parameter accuracy for breath-hold DCE-MRI of liver tumours.

    abstract::Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is a valuable tool for assessing treatment response to novel cancer therapeutics. With appropriate data acquisition, quantitative functional parameter estimates can be obtained by fitting a model to the data. This research focuses on applying a dual-input ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/7/023

    authors: Orton MR,Miyazaki K,Koh DM,Collins DJ,Hawkes DJ,Atkinson D,Leach MO

    更新日期:2009-04-07 00:00:00

  • SiPM signal readout for inter-crystal scatter event identification in PET detectors.

    abstract::In positron emission tomography (PET) with pixelated detectors, a significant number of annihilation photons interact with scintillation crystals through single or multiple Compton scattering events. When these partial energy depositions occur across multiple crystal elements, we call them inter-crystal scatter (ICS) ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba8b4

    authors: Park H,Lee JS

    更新日期:2020-10-21 00:00:00

  • A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode.

    abstract::Respiratory gating based on external surrogates is performed in many clinics. We have developed a new technique for treatment verification using an electronic portal imaging device (EPID) in cine mode for gated 3D conformal therapy. Implanted radiopaque fiducial markers inside or near the target are required for this ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/16/002

    authors: Berbeco RI,Neicu T,Rietzel E,Chen GT,Jiang SB

    更新日期:2005-08-21 00:00:00

  • Analysis of a large number of clinical studies for breast cancer radiotherapy: estimation of radiobiological parameters for treatment planning.

    abstract::Numerous studies of early-stage breast cancer treated with breast conserving surgery (BCS) and radiotherapy (RT) have been published in recent years. Both external beam radiotherapy (EBRT) and/or brachytherapy (BT) with different fractionation schemes are currently used. The present RT practice is largely based on emp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,meta分析

    doi:10.1088/0031-9155/48/20/004

    authors: Guerrero M,Li XA

    更新日期:2003-10-21 00:00:00

  • Denoising of multi b-value diffusion-weighted MR images using deep image prior.

    abstract::The clinical value of multiple b-value diffusion-weighted (DW) magnetic resonance imaging (MRI) has been shown in many studies. However, DW-MRI often suffers from low signal-to-noise ratio, especially at high b-values. To address this limitation, we present an image denoising method based on the concept of deep image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8105

    authors: Lin YC,Huang HM

    更新日期:2020-05-11 00:00:00