Optimizing functional parameter accuracy for breath-hold DCE-MRI of liver tumours.

Abstract:

:Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is a valuable tool for assessing treatment response to novel cancer therapeutics. With appropriate data acquisition, quantitative functional parameter estimates can be obtained by fitting a model to the data. This research focuses on applying a dual-input single-compartment pharmacokinetic model to breath-hold DCE-MRI imaging of the liver. In this paper, the use of two breath-holds, providing greater temporal information, is compared with a single breath-hold approach. Computer simulations are used to assess the accuracy, precision and sensitivity to input function errors obtained for parameters estimated from the two imaging protocols. Data from ten patients were analysed to assess the noise statistics obtained from the two breath-hold protocols. The noise statistics were used with a pharmacokinetic liver model to simulate data, from which the estimation accuracy, precision and sensitivity for the two protocols were assessed. Data from the ten patients were also analysed, and the estimates were compared with literature values. This work demonstrates the feasibility of obtaining functional liver perfusion estimates over a 3D volume using a sequential breath-hold protocol. The simulation results show that the protocol consisting of two images per breath-hold is to be preferred as it requires identical patient co-operation, but provides parameter estimates that have superior accuracy and precision.

journal_name

Phys Med Biol

authors

Orton MR,Miyazaki K,Koh DM,Collins DJ,Hawkes DJ,Atkinson D,Leach MO

doi

10.1088/0031-9155/54/7/023

subject

Has Abstract

pub_date

2009-04-07 00:00:00

pages

2197-215

issue

7

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(09)88220-1

journal_volume

54

pub_type

杂志文章
  • Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis.

    abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5452

    authors: Tyagi N,Fontenla S,Zhang J,Cloutier M,Kadbi M,Mechalakos J,Zelefsky M,Deasy J,Hunt M

    更新日期:2017-04-21 00:00:00

  • Analysis on reversible/irreversible electroporation region in lung adenocarcinoma cell modelin vitrowith electric pulses delivered by needle electrodes.

    abstract::Irreversible electroporation (IRE) is a minimally invasive tumor therapy using pulsed electric field with high intensity while the important tissues such as blood vessel, bile duct, and nerve are preserved. In addition to ablation area, reversible electroporation (RE) region is also generated using needle electrodes f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc12e

    authors: Lv Y,Tang X,Peng W,Cheng X,Chen S,Yao C

    更新日期:2020-10-14 00:00:00

  • Effective dose conversion coefficient for gamma ray exposure from an overhead plume.

    abstract::The external radiation exposure from an overhead plume containing gamma emitting radionuclides can contribute substantial dose to the ground receptor during normal operations as well as accidental release conditions of nuclear facilities. In order to estimate the effective dose conversion coefficients (DCCs) directly,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2c92

    authors: Dey R,Patni HK,Deo Singh K,Kulkarni MS,Anand S

    更新日期:2019-08-01 00:00:00

  • Characterization of cardiovascular liver motion for the eventual application of elasticity imaging to the liver in vivo.

    abstract::Elastography, which uses ultrasound to image the tissue strain that results from an applied displacement, can display tumours and heat-ablated tissue with high contrast. However, its application to liver in vivo may be problematic due to the presence of respiratory and cardiovascular sources of displacement. The aim o...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/49/18/001

    authors: Kolen AF,Miller NR,Ahmed EE,Bamber JC

    更新日期:2004-09-21 00:00:00

  • Radiation damage, repopulation and cell recovery analysis of in vitro tumour cell megacolony culture data using a non-Poissonian cell repopulation TCP model.

    abstract::The effects of radiation damage, tumour repopulation and cell sublethal damage repair and the possibility of extracting information about the model parameters describing them are investigated in this work. Previously published data on two different cultured cell lines were analysed with the help of a tumour control pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/13/006

    authors: Stavrev P,Weldon M,Warkentin B,Stavreva N,Fallone BG

    更新日期:2005-07-07 00:00:00

  • Absorbed dose determination at short distance from 60Co and 192Ir brachytherapy sources.

    abstract::This paper presents two methods for absorbed dose determination with ionization chambers at short distance from 60Co and 192Ir brachytherapy sources. The methods are modifications of the Bragg-Gray and large cavity principles given in the IAEA code of practice for high- and medium-energy photon beams. A non-uniformity...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/11/002

    authors: Tölli H,Johansson KA

    更新日期:1998-11-01 00:00:00

  • A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study.

    abstract::It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/001

    authors: Dharmakumar R,Plewes DB,Wright GA

    更新日期:2005-10-21 00:00:00

  • ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy.

    abstract::Task group 43 (TG43)-based dosimetry algorithms are efficient for brachytherapy dose calculation in water. However, human tissues have chemical compositions and densities different than water. Moreover, the mutual shielding effect of seeds on each other (interseed attenuation) is neglected in the TG43-based dosimetry ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3273

    authors: Afsharpour H,Landry G,D'Amours M,Enger S,Reniers B,Poon E,Carrier JF,Verhaegen F,Beaulieu L

    更新日期:2012-06-07 00:00:00

  • Development and implementation in the Monte Carlo code PENELOPE of a new virtual source model for radiotherapy photon beams and portal image calculation.

    abstract::This work aims at developing a generic virtual source model (VSM) preserving all existing correlations between variables stored in a Monte Carlo pre-computed phase space (PS) file, for dose calculation and high-resolution portal image prediction. The reference PS file was calculated using the PENELOPE code, after the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/14/5215

    authors: Chabert I,Barat E,Dautremer T,Montagu T,Agelou M,Croc de Suray A,Garcia-Hernandez JC,Gempp S,Benkreira M,de Carlan L,Lazaro D

    更新日期:2016-07-21 00:00:00

  • Comments on 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy'.

    abstract::By analyzing the radiobiological model, and the equations derived from the model, it is shown that the main results of the article 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy' by Wiklund et al (2011 Phys. Med. Biol. 56 7585-600) are valid only under the condition...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/58/18/6585

    authors: Grusell E

    更新日期:2013-09-21 00:00:00

  • Monte Carlo study of x-ray detection configurations for benchtop x-ray fluorescence computed tomography of gold nanoparticle-loaded objects.

    abstract::Over the last decade, the performance of benchtop x-ray fluorescence computed tomography (XFCT) systems has been significantly enhanced through hardware and software optimizations. Recent studies have indicated the need of energy-resolving pixelated/array detectors in the x-ray detection component to further improve t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9774

    authors: Moktan H,Ahmed MF,Jayarathna S,Deng L,Cho SH

    更新日期:2020-08-31 00:00:00

  • Low-frequency conductivity tensor imaging with a single current injection using DT-MREIT.

    abstract::Diffusion tensor - magnetic resonance electrical impedance tomography (DT-MREIT) is an imaging modality to obtain low-frequency anisotropic conductivity distribution employing diffusion tensor imaging (DTI) and magnetic resonance electrical impedance tomography (MREIT) techniques. DT-MREIT is based on the linear relat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abddcf

    authors: Sadighi M,Sisman M,Acikgoz BC,Eroglu HH,Eyuboglu BM

    更新日期:2021-01-20 00:00:00

  • Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples.

    abstract::The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brach...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/020

    authors: O'Hagan JJ,Samani A

    更新日期:2009-04-21 00:00:00

  • Changes in lung tumor shape during respiration.

    abstract::Evidence that some lung tumors change shape during respiration is derived from respiratory gated CT data by statistical shape modeling and image manipulation. Some tumors behave as rigid objects while others show systematic shape changes. Two views of lung motion are presented to allow analysis of the results. In the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/4/919

    authors: Kyriakou E,McKenzie DR

    更新日期:2012-02-21 00:00:00

  • Ionization chamber correction factors for MR-linacs.

    abstract::Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to system...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac4f2

    authors: Pojtinger S,Dohm OS,Kapsch RP,Thorwarth D

    更新日期:2018-06-07 00:00:00

  • Sensitivity of different dose scoring methods on organ-specific neutron dose calculations in proton therapy.

    abstract::Scattered doses, e.g. neutron doses in proton therapy, are of concern in radiation therapy. Although measured data are the gold standard, Monte Carlo simulations allow a more realistic consideration of patient anatomy via whole-body phantoms. When calculating neutron doses with Monte Carlo techniques, the dose can be ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/17/004

    authors: Jarlskog CZ,Paganetti H

    更新日期:2008-09-07 00:00:00

  • Influence of beam characteristics and detector size in negative-pion dose studies.

    abstract::Dose calculations were performed for a tissue phantom irradiated by uniform circular beams of negative pions with an assumed gaussian momentum distribution. The mean momentum of the pions was varied from 104.4 to 171.5 MeV/c (mean range 5-20 cm in unit-density tissue) and the momentum spread from 0 to 5% of the mean. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/3/012

    authors: Hamm RN,Wright HA,Turner JE

    更新日期:1979-05-01 00:00:00

  • A new column-generation-based algorithm for VMAT treatment plan optimization.

    abstract::We study the treatment plan optimization problem for volumetric modulated arc therapy (VMAT). We propose a new column-generation-based algorithm that takes into account bounds on the gantry speed and dose rate, as well as an upper bound on the rate of change of the gantry speed, in addition to MLC constraints. The alg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4569

    authors: Peng F,Jia X,Gu X,Epelman MA,Romeijn HE,Jiang SB

    更新日期:2012-07-21 00:00:00

  • Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner.

    abstract::An accurate, low noise estimate of photon attenuation in the subject is required for quantitative microPET studies of molecular tracer distributions in vivo. In this work, several transmission-based measurement techniques were compared, including coincidence mode with and without rod windowing, singles mode with two d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/16/008

    authors: Lehnert W,Meikle SR,Siegel S,Newport D,Banati RB,Rosenfeld AB

    更新日期:2006-08-21 00:00:00

  • On the development of a VIPARnd radiotherapy 3D polymer gel dosimeter.

    abstract::This work presents an improvement of the VIPARnd ('nd' stands for 'normoxic, double', or VIP) polymer gel dosimeter. The gel composition was altered by increasing the concentration of the monomeric components, N-vinylpyrrolidone (NVP) and N,N'-methylenebisacrylamide (MBA), in co-solvent solutions. The optimal composit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5089

    authors: Kozicki M,Jaszczak M,Maras P,Dudek M,Cłapa M

    更新日期:2017-02-07 00:00:00

  • Noise reduction and convergence of Bayesian algorithms with blobs based on the Huber function and median root prior.

    abstract::Iterative image reconstruction algorithms have the potential to produce low noise images. Early stopping of the iteration process is problematic because some features of the image may converge slowly. On the other hand, there may be noise build-up with increased number of iterations. Therefore, we examined the stabili...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/20/004

    authors: Chlewicki W,Hermansen F,Hansen SB

    更新日期:2004-10-21 00:00:00

  • 1D dynamic beam modulation: methods to counteract inertia effects.

    abstract::Dynamic modulation can be affected by inaccuracies when the required acceleration is larger than the highest allowed by the mechanical characteristics of the whole apparatus. In this study, inertia effects have been investigated with regard to the single absorber 1D modulation, analysing primarily how the acceleration...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/11/401

    authors: Corletto D,Broggi S,Fiorino C,Mangili P,Calandrino R,Lev A,Gennari D,Rudello F

    更新日期:1999-11-01 00:00:00

  • Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules.

    abstract::This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa610

    authors: Gong J,Liu JY,Sun XW,Zheng B,Nie SD

    更新日期:2018-02-05 00:00:00

  • The effect of motion correction on pharmacokinetic parameter estimation in dynamic-contrast-enhanced MRI.

    abstract::A dynamic-contrast-enhanced magnetic resonance imaging (DCE-MRI) dataset consists of many imaging frames, often acquired both before and after contrast injection. Due to the length of time spent acquiring images, patient motion is likely and image re-alignment or registration is required before further analysis such a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/24/001

    authors: Melbourne A,Hipwell J,Modat M,Mertzanidou T,Huisman H,Ourselin S,Hawkes DJ

    更新日期:2011-12-21 00:00:00

  • Iterative reconstruction of SiPM light response functions in a square-shaped compact gamma camera.

    abstract::Compact gamma cameras with a square-shaped monolithic scintillator crystal and an array of silicon photomultipliers (SiPMs) are actively being developed for applications in areas such as small animal imaging, cancer diagnostics and radiotracer guided surgery. Statistical methods of position reconstruction, which are p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6029

    authors: Morozov A,Alves F,Marcos J,Martins R,Pereira L,Solovov V,Chepel V

    更新日期:2017-05-07 00:00:00

  • Clinical ultraviolet dosimetry with a CCD monochromator array spectroradiometer.

    abstract::Single monochromator charge-coupled device (CCD) array spectroradiometers have the advantage of ease of use and speed compared with double grating instruments. Their inherently inferior stray-light rejection, however, can critically affect their accuracy in phototherapy and research-related dosimetry applications. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/026

    authors: Coleman A,Sarkany R,Walker S

    更新日期:2008-09-21 00:00:00

  • The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp.

    abstract::In recent years there has been a large amount of research into the potential use of radiation sensitive gels for three-dimensional verification of clinical radiotherapy doses. In this paper we report the use of a MAGIC gel dosimeter (Fong et al 2001 Phys. Med. Biol. 46 3105) for the verification of a specific patient'...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/9/003

    authors: Trapp JV,Partridge M,Hansen VN,Childs P,Bedford J,Warrington AP,Leach MO,Webb S

    更新日期:2004-05-07 00:00:00

  • Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility.

    abstract::Reliable treatment planning of highly conformal scanned ion beam therapy demands accurate tools for the determination and characterization of the individual pencil-like beams building up the integral dose delivery and related mixed radiation field. At present, clinically practicable inverse treatment planning systems ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3759

    authors: Parodi K,Mairani A,Brons S,Hasch BG,Sommerer F,Naumann J,Jäkel O,Haberer T,Debus J

    更新日期:2012-06-21 00:00:00

  • Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering.

    abstract::This paper addresses fundamental issues that underlie the interpretation of images acquired from turbid tissues by optical-coherence tomography (OCT). The attenuation and backscattering properties of freshly excised rat arteries and their dependence on the focusing and collection optics of the OCT system were measured...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/10/013

    authors: Schmitt JM,Knüttel A,Yadlowsky M,Eckhaus MA

    更新日期:1994-10-01 00:00:00

  • Uncertainties in Monte Carlo-based absorbed dose calculations for an experimental benchmark.

    abstract::There is a need to verify the accuracy of general purpose Monte Carlo codes like EGSnrc, which are commonly employed for investigations of dosimetric problems in radiation therapy. A number of experimental benchmarks have been published to compare calculated values of absorbed dose to experimentally determined values....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/19/7637

    authors: Renner F,Wulff J,Kapsch RP,Zink K

    更新日期:2015-10-07 00:00:00