Modified sector-integration method for predicting the output factors of electron beams including extended source to surface distance.

Abstract:

:A modified sector-integration method is presented that can predict the output factors of irregular shaped electron fields even in the case of extended source to surface distance (SSD). The model takes as input measured output factors for circular inserts of various radii. These circular fields were measured at SSDs of 100, 105 and 110 cm to determine the effective source distance as a function of radius (ESD(r)). For an arbitrary electron field at any SSD, the shape is divided into small sectors, and the contribution calculated from the radius and ESD(r). The calculated output factors were verified by direct measurements of various types of electron fields mainly based on clinical use. The energies modelled were 8, 10 and 12 MeV for applicator sizes of 10 cm x 10 cm and 14 cm x 14 cm (defined at 95 cm). The calculated values agreed with the measured data within 1% for the various rectangular cutouts including extended source to surface distance. We retrospectively modelled 97 patient inserts of irregular shape, and found agreement within 2% of measured values.

journal_name

Phys Med Biol

authors

Choi DR,Wolters J,Mason D,Baillie A

doi

10.1088/0031-9155/45/11/318

subject

Has Abstract

pub_date

2000-11-01 00:00:00

pages

3367-72

issue

11

eissn

0031-9155

issn

1361-6560

journal_volume

45

pub_type

杂志文章
  • Optimization of a depth of interaction encoding PET block detector for a PET/MRI insert.

    abstract::Preclinical positron emission tomography, combined with magnetic resonance imaging (PET/MRI), is increasingly used as a tool to simultaneously characterize functional processes in vivo. Many emerging preclinical applications, however, are limited by PET detection sensitivity, especially when generating short imaging f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaef59

    authors: Selfridge AR,Cherry SR,Judenhofer MS

    更新日期:2018-12-06 00:00:00

  • Local hydrogen clearance as a method for the measurement of capillary blood flow.

    abstract::A hydrogen clearance technique for the measurement of capillary blood flow in skeletal muscle (both resting and working) and the beating heart in experimental animals is described. Various methods for introducing the hydrogen into the region of measurement are compared, together with the appropriate methods for evalua...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/005

    authors: Harrison DK,Kessler M

    更新日期:1989-10-01 00:00:00

  • A low cost method for hard x-ray grating interferometry.

    abstract::Grating interferometry is advantageous over conventional x-ray absorption imaging because it enables the detection of samples constituted by low atomic number elements (low-Z materials). Therefore, it has a potential application in biological science and medical diagnostics. The grating interferometry has some critica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/23/8266

    authors: Du Y,Lei Y,Liu X,Huang J,Zhao Z,Guo J,Li J,Niu H

    更新日期:2016-12-07 00:00:00

  • Reduction of scatter in breast CT yields improved microcalcification visibility.

    abstract::The inadequate visibility of microcalcifications-small calcium deposits that cue radiologists to early stages of cancer-is a major limitation in current designs of dedicated breast computed tomography (bCT). This limitation has previously been attributed to the constituent components, spatial resolution, and utilized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abae07

    authors: Ghazi P

    更新日期:2020-12-04 00:00:00

  • The Fokker-Planck equation for coupled Brown-Néel-rotation.

    abstract::Calculating the dynamic properties of magnetization of single-domain particles is of great importance for the tomographic imaging modality known as magnetic particle imaging (MPI). Although the assumption of instantaneous thermodynamic equilibrium (Langevin function) after application of time-dependent magnetic fields...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa186

    authors: Weizenecker J

    更新日期:2018-01-22 00:00:00

  • Trimmer sequencing time minimization during dynamically collimated proton therapy using a colony of cooperating agents.

    abstract::The dynamic collimation system (DCS) can be combined with pencil beam scanning proton therapy to deliver highly conformal treatment plans with unique collimation at each energy layer. This energy layer-specific collimation is accomplished through the synchronized motion of four trimmer blades that intercept the proton...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab416d

    authors: Smith BR,Hyer DE,Flynn RT,Hill PM,Culberson WS

    更新日期:2019-10-21 00:00:00

  • Correction for 'artificial' electron disequilibrium due to cone-beam CT density errors: implications for on-line adaptive stereotactic body radiation therapy of lung.

    abstract::Cone-beam computed tomography (CBCT) has rapidly become a clinically useful imaging modality for image-guided radiation therapy. Unfortunately, CBCT images of the thorax are susceptible to artefacts due to scattered photons, beam hardening, lag in data acquisition, and respiratory motion during a slow scan. These limi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/4157

    authors: Disher B,Hajdok G,Wang A,Craig J,Gaede S,Battista JJ

    更新日期:2013-06-21 00:00:00

  • An automated method for adaptive radiation therapy for prostate cancer patients using continuous fiducial-based tracking.

    abstract::Electromagnetic tracking technology is primarily used for continuous prostate localization during radiotherapy, but offers potential value for evaluation of dosimetric coverage and adequacy of treatment for dynamic targets. We developed a highly automated method for daily computation of cumulative dosimetric effects o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/005

    authors: Noel CE,Santanam L,Olsen JR,Baker KW,Parikh PJ

    更新日期:2010-01-07 00:00:00

  • Post-processing noise removal algorithm for magnetic resonance imaging based on edge detection and wavelet analysis.

    abstract::A post-processing noise suppression technique for biomedical MRI images is presented. The described procedure recovers both sharp edges and smooth surfaces from a given noisy MRI image; it does not blur the edges and does not introduce spikes or other artefacts. The fine details of the image are also preserved. The pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/13/310

    authors: Placidi G,Alecci M,Sotgiu A

    更新日期:2003-07-07 00:00:00

  • Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR Penta-Guide phantom.

    abstract::For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of det...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/19/002

    authors: Sykes JR,Lindsay R,Dean CJ,Brettle DS,Magee DR,Thwaites DI

    更新日期:2008-10-07 00:00:00

  • Meshless reconstruction technique for digital tomosynthesis.

    abstract::A novel meshless reconstruction algorithm for digital tomosynthesis (DT) is presented and assessed against experimental data. The algorithm does not require a three-dimensional grid or mesh allocation and performs a slice-by-slice reconstruction where each slice position can be chosen at runtime. The methodology is ba...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7685

    authors: Soloviev VY,Renforth KL,Dirckx CJ,Wells SG

    更新日期:2020-04-20 00:00:00

  • Numerical study of oxygen transport in a carotid bifurcation.

    abstract::This study investigates the oxygen mass transport in the region around the human carotid bifurcation, particularly addressing the effects of bifurcation geometry and pulsatile blood flow on the oxygen transport between the blood flow and artery wall tissue, coupled with the metabolic oxygen consumption and oxygen diff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/004

    authors: Tada S

    更新日期:2010-07-21 00:00:00

  • Large blood vessel cooling in heated tissues: a numerical study.

    abstract::Large blood vessels can produce steep temperature gradients in heated tissues leading to inadequate tissue temperatures during hyperthermia. This paper utilizes a finite difference scheme to solve the basic equations of heat transfer and fluid flow to model blood vessel cooling. Unlike previous formulations, heat tran...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/4/001

    authors: Kolios MC,Sherar MD,Hunt JW

    更新日期:1995-04-01 00:00:00

  • Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector.

    abstract::The signal-to-noise ratio (SNR) in x-ray imaging can be increased using a photon counting detector which could allow for rejecting electronics noise and for weighting x-ray photons according to their energies. This approach, however, was not feasible for a long time because photon counting x-ray detectors with very hi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/16/009

    authors: Shikhaliev PM

    更新日期:2009-08-21 00:00:00

  • Verification of absolute dose rates for intravascular brachytherapy beta sources.

    abstract::The absolute dose rate around beta sources for intravascular brachytherapy was measured with thin thermoluminescent (TL) dosimeters and radiochromic film. The calibration of these dosimeters was performed at the dose maximum in a 6 MeV electron beam of a linear accelerator. Compared to the values given by the manufact...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/8/311

    authors: Piessens M,Reynaert N

    更新日期:2000-08-01 00:00:00

  • The effect of authentic metallic implants on the SAR distribution of the head exposed to 900, 1800 and 2450 MHz dipole near field.

    abstract::As the use of radiofrequency (RF) electromagnetic (EM) fields has increased along with increased use of wireless communication, the possible related health risks have also been widely discussed. One safety aspect is the interaction of medical implants and RF devices like mobile phones. In the literature, effects on ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/001

    authors: Virtanen H,Keshvari J,Lappalainen R

    更新日期:2007-03-07 00:00:00

  • Quantitative x-ray dark-field computed tomography.

    abstract::The basic principles of x-ray image formation in radiology have remained essentially unchanged since Röntgen first discovered x-rays over a hundred years ago. The conventional approach relies on x-ray attenuation as the sole source of contrast and draws exclusively on ray or geometrical optics to describe and interpre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/017

    authors: Bech M,Bunk O,Donath T,Feidenhans'l R,David C,Pfeiffer F

    更新日期:2010-09-21 00:00:00

  • An age-dependent series of eye models for radiation dosimetry.

    abstract::Several studies have been appeared, up to now, that indicate the effect of accurate simulation on dose received by different substructures of the eye, irradiated by external beams of short-range radiation such as electron. Different representations of the eye have consequently been introduced. Their accuracies depend ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2059

    authors: Vejdani-Noghreiyan A,Ebrahimi-Khankook A

    更新日期:2019-07-02 00:00:00

  • Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy.

    abstract::The purpose of this study is to develop an adaptive prior knowledge guided image estimation technique to reduce the scan angle needed in the limited-angle intrafraction verification (LIVE) system for 4D-CBCT reconstruction. The LIVE system has been previously developed to reconstruct 4D volumetric images on-the-fly du...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6913

    authors: Zhang Y,Yin FF,Zhang Y,Ren L

    更新日期:2017-05-07 00:00:00

  • A dedicated phantom design for positron emission mammography performance evaluation.

    abstract::A standard protocol for performance evaluation of positron emission mammography (PEM) systems has not yet been established. In this work we propose a methodology based on the design of specific phantoms for this imaging modality with component dimensions in accordance with typical breast lesion sizes together with the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba7d1

    authors: Torres-Urzúa LF,Alva-Sanchez H,Martinez-Davalos A,García-Pérez FO,Peruyero-Rivas RM,Rodriguez-Villafuerte M

    更新日期:2020-07-21 00:00:00

  • Optimization of multiply acquired magnetic flux density B(z) using ICNE-Multiecho train in MREIT.

    abstract::The aim of magnetic resonance electrical impedance tomography (MREIT) is to visualize the electrical properties, conductivity or current density of an object by injection of current. Recently, the prolonged data acquisition time when using the injected current nonlinear encoding (ICNE) method has been advantageous for...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/9/021

    authors: Nam HS,Kwon OI

    更新日期:2010-05-07 00:00:00

  • A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans.

    abstract::A circular scanning trajectory is and will likely remain a popular choice of trajectory in computed tomography (CT) imaging because it is easy to implement and control. Filtered-backprojection (FBP)-based algorithms have been developed previously for approximate and exact reconstruction of the entire image or a region...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/18/011

    authors: Pan X,Xia D,Zou Y,Yu L

    更新日期:2004-09-21 00:00:00

  • The GSF family of voxel phantoms.

    abstract::Voxel phantoms are human models based on computed tomographic or magnetic resonance images obtained from high-resolution scans of a single individual. They consist of a huge number of volume elements (voxels) and are at the moment the most precise representation of the human anatomy. The purpose of this paper is to in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/47/1/307

    authors: Petoussi-Henss N,Zanki M,Fill U,Regulla D

    更新日期:2002-01-07 00:00:00

  • Inverse planning for functional image-guided intensity-modulated radiation therapy.

    abstract::Radiation therapy is an image-guided process whose success critically depends on the imaging modality used for treatment planning and the level of integration of the available imaging information. In this work, we establish a dose optimization framework for incorporating metabolic information from functional imaging m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/20/301

    authors: Xing L,Cotrutz C,Hunjan S,Boyer AL,Adalsteinsson E,Spielman D

    更新日期:2002-10-21 00:00:00

  • The design of anisotropic diffusion phantoms for the validation of diffusion weighted magnetic resonance imaging.

    abstract::Diffusion weighted magnetic resonance imaging offers a non-invasive tool to explore the three-dimensional structure of brain white matter in clinical practice. Anisotropic diffusion hardware phantoms are useful for the quantitative validation of this technique. This study provides guidelines on how to manufacture anis...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/19/009

    authors: Fieremans E,De Deene Y,Delputte S,Ozdemir MS,Achten E,Lemahieu I

    更新日期:2008-10-07 00:00:00

  • Optimizing spectral CT parameters for material classification tasks.

    abstract::In this work, we propose a framework for optimizing spectral CT imaging parameters and hardware design with regard to material classification tasks. Compared with conventional CT, many more parameters must be considered when designing spectral CT systems and protocols. These choices will impact material classification...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4599

    authors: Rigie DS,La Rivière PJ

    更新日期:2016-06-21 00:00:00

  • Full-field speckle interferometry for non-contact photoacoustic tomography.

    abstract::A full-field speckle interferometry method for non-contact and prospectively high speed Photoacoustic Tomography is introduced and evaluated as proof of concept. Thermoelastic pressure induced changes of the objects topography are acquired in a repetitive mode without any physical contact to the object. In order to ob...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/4045

    authors: Horstmann J,Spahr H,Buj C,Münter M,Brinkmann R

    更新日期:2015-05-21 00:00:00

  • Simulated lesion, human observer performance comparison between thin-section dedicated breast CT images versus computed thick-section simulated projection images of the breast.

    abstract::The objective of this study was to compare the lesion detection performance of human observers between thin-section computed tomography images of the breast, with thick-section (>40 mm) simulated projection images of the breast. Three radiologists and six physicists each executed a two alterative force choice (2AFC) s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/8/3347

    authors: Chen L,Boone JM,Abbey CK,Hargreaves J,Bateni C,Lindfors KK,Yang K,Nosratieh A,Hernandez A,Gazi P

    更新日期:2015-04-21 00:00:00

  • Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u (12)C beam.

    abstract::The radiation used in hadrontherapy treatments interacts with the patient body producing secondary particles, either neutral or charged, that can be used for dose and Bragg peak monitoring and to provide a fast feedback on the treatment plans. Recent results obtained from the authors on simplified setups (mono-energet...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1857

    authors: Piersanti L,Bellini F,Bini F,Collamati F,De Lucia E,Durante M,Faccini R,Ferroni F,Fiore S,Iarocci E,La Tessa C,Marafini M,Mattei I,Patera V,Ortega PG,Sarti A,Schuy C,Sciubba A,Vanstalle M,Voena C

    更新日期:2014-04-07 00:00:00

  • Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner.

    abstract::Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSE...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/N35

    authors: Poon JK,Dahlbom ML,Casey ME,Qi J,Cherry SR,Badawi RD

    更新日期:2015-02-07 00:00:00