Radiation dose factors for alpha-emitters in osteons and some considerations on dose non-uniformity ratios and relative distribution factors.

Abstract:

:Dose factors for locations within a tissue-filled cylindrical cavity bounded by an infinite medium of bone labelled with an alpha-emitter are calculated by means of a Monte Carlo procedure. The calculational approach is general and allows us to determine dose factors for specific distances or target volumes defined by concentric cylinders, as well as various source geometries including surface sources, buried surface sources, infinite and bounded volume sources, and also comprises plane (trabecular) surfaces as a limiting case. Values for the dose factors and the contribution of cross-fire traversals are calculated mainly for 239Pu and 226Ra and a typical Haversian canal diameter of 30 microns in beagles and 70 microns in humans. Also tables are given that allow dose factors to be derived for the relevant range of alpha-particle energies, diameters and target distances. The dose non-uniformity factors (local dose rate/average skeletal dose rate) for 239Pu are 27.2 in humans and 14.0 in beagles. The corresponding values for 226Ra are in the ranges 1.18-1.26 (humans) and 0.90-0.97 (beagles) for a 222Rn retention between 10-30%. The relative distribution factors 239Pu/226Ra are 21.5-23.0 for humans and 14.5-15.6 for dogs. General expressions for calculating non-uniformity factors and relative distribution factors are derived and implications are discussed in the light of some experimental findings.

journal_name

Phys Med Biol

authors

Polig E

doi

10.1088/0031-9155/34/3/007

subject

Has Abstract

pub_date

1989-03-01 00:00:00

pages

353-67

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

34

pub_type

杂志文章
  • On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations.

    abstract::A comparative study was performed to reveal differences and relative figures of merit of seven different calculation algorithms for photon beams when applied to inhomogeneous media. The following algorithms were investigated: Varian Eclipse: the anisotropic analytical algorithm, and the pencil beam with modified Batho...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/011

    authors: Fogliata A,Vanetti E,Albers D,Brink C,Clivio A,Knöös T,Nicolini G,Cozzi L

    更新日期:2007-03-07 00:00:00

  • Modulated photon radiotherapy (XMRT): an algorithm for the simultaneous optimization of photon beamlet energy and intensity in external beam radiotherapy (EBRT) planning.

    abstract::This is a proof of principle study on an algorithm for optimizing external beam radiotherapy in terms of both photon beamlet energy and fluence. This simultaneous beamlet energy and fluence optimization is denoted modulated photon radiotherapy (XMRT). XMRT is compared with single-energy intensity modulated radiotherap...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/1476

    authors: McGeachy P,Villarreal-Barajas JE,Zinchenko Y,Khan R

    更新日期:2016-02-21 00:00:00

  • Imaging placental function: current technology, clinical needs, and emerging modalities.

    abstract::The function of the placenta is challenging to characterize and as a result is understudied, despite the growing awareness of the impact of the placental environment on human health and development. Medical imaging has the potential to improve our ability to screen for diseases associated with placental insufficiency,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6560/aaccd9

    authors: Wu C,Bayer CL

    更新日期:2018-07-09 00:00:00

  • Comment on 'the use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics'.

    abstract::In this letter the authors highlight the presence of an error appearing in the discussion of the note 'The use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics' previously published by them (Binzoni et al 2006 Phys. Med. Biol. 51 N313). In the light of this error, the discussion ...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/51/22/L01

    authors: Binzoni T,Leung TS,Gandjbakhche AH,Rüfenacht D,Delpy DT

    更新日期:2006-11-21 00:00:00

  • A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy.

    abstract::RapidArc, recently released by Varian Medical Systems, is a novel extension of IMRT in which an optimized 3D dose distribution may be delivered in a single gantry rotation of 360 degrees or less. The purpose of this study was to investigate the accuracy of the analytical anisotropic algorithm (AAA), the sole algorithm...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/24/011

    authors: Gagne IM,Ansbacher W,Zavgorodni S,Popescu C,Beckham WA

    更新日期:2008-12-21 00:00:00

  • Strategies to improve 3D whole-body PET image reconstruction.

    abstract::An algorithm is described for three-dimensional whole-body (3DWB) image reconstruction in positron emission tomography. For whole-body applications, improvements to the popular fixed-axial-acceptance-angle technique are achieved by combining axially adjacent projection data available with a long-axis data set. Time-co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/8/013

    authors: Cutler PD,Xu M

    更新日期:1996-08-01 00:00:00

  • Accurate helical cone-beam CT reconstruction with redundant data.

    abstract::We present a new image reconstruction algorithm for helical cone-beam computed tomography (CT). This algorithm is designed for data collected at or near maximum pitch, and provides a theoretically exact and stable reconstruction while beneficially using all measured data. The main operations involved are a differentia...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/15/001

    authors: Schöndube H,Stierstorfer K,Noo F

    更新日期:2009-08-07 00:00:00

  • Suitability of EBT3 GafChromic film for quality assurance in MR-guided radiotherapy at 0.35 T with and without real-time MR imaging.

    abstract::The 0.35 T 60Co MRIdian system (ViewRay Inc., Mountain View) has been in clinical use in our institution since May 2016. For quality assurance (QA) of dose delivery and end-to-end testing for this machine, a reliable dosimeter is required. However, it is possible that a magnetic field may cause perturbations to dosime...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad58d

    authors: Barten DLJ,Hoffmans D,Palacios MA,Heukelom S,van Battum LJ

    更新日期:2018-08-20 00:00:00

  • Medical personnel and patient dosimetry during coronary angiography and intervention.

    abstract::Percutaneous coronary interventions are associated with increased radiation exposure compared to most radiological examinations. This prospective study aimed at (1) measuring entrance doses for all in-room personnel, (2) performing an assessment of patient effective dose and intracoronary doses, (3) investigating the ...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/48/18/307

    authors: Efstathopoulos EP,Makrygiannis SS,Kottou S,Karvouni E,Giazitzoglou E,Korovesis S,Tzanalaridou E,Raptou PD,Katritsis DG

    更新日期:2003-09-21 00:00:00

  • EPR dosimetry of radiotherapy photon beams in inhomogeneous media using alanine films.

    abstract::In the current work, EPR (electron paramagnetic resonance) dosimetry using alanine films (134 microm thick) was utilized for dose measurements in inhomogeneous phantoms irradiated with radiotherapy photon beams. The main phantom material was PMMA, while either Styrofoam or aluminium was introduced as an inhomogeneity....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/24/003

    authors: Osterås BH,Hole EO,Olsen DR,Malinen E

    更新日期:2006-12-21 00:00:00

  • Optimization and performance study of a proton CT system for pre-clinical small animal imaging.

    abstract::Proton computed tomography (pCT) promises to reduce or even eliminate range uncertainties inherent in the conversion of Hounsfield units into relative stopping power (RSP) for proton therapy treatment planning. This is of particular interest for proton irradiation studies in animal models due to the high precision req...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8afc

    authors: Meyer S,Bortfeldt J,Lämmer P,Englbrecht FS,Pinto M,Schnürle K,Würl M,Parodi K

    更新日期:2020-08-13 00:00:00

  • Enhancement of subharmonic emission from encapsulated microbubbles by using a chirp excitation technique.

    abstract::Subharmonic contrast imaging promises to improve ultrasound-imaging quality by taking advantage of an increased contrast to tissue signal. However, acoustic pressures beyond the subharmonic generation threshold using common ultrasound pulses may induce significant contrast microbubble destruction. In this work, a chir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/18/005

    authors: Zhang D,Gong Y,Gong X,Liu Z,Tan K,Zheng H

    更新日期:2007-09-21 00:00:00

  • Study of the PTW microLion chamber temperature dependence.

    abstract::The use of liquid ionization chambers in radiotherapy has grown during the past few years. While for air ionization chambers the k(TP) correction for air mass density due to pressure and temperature variations is well known, less work has been done on the case of liquid ionization chambers, where there is still the ne...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2705

    authors: Gómez F,González-Castaño D,Díaz-Botana P,Pardo-Montero J

    更新日期:2014-06-07 00:00:00

  • Photon detection efficiency of laboratory-based x-ray phase contrast imaging techniques for mammography: a Monte Carlo study.

    abstract::An important challenge in real-world biomedical applications of x-ray phase contrast imaging (XPCI) techniques is the efficient use of the photon flux generated by an incoherent and polychromatic x-ray source. This efficiency can directly influence dose and exposure time and ideally should not affect the superior cont...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7a92

    authors: Saghamanesh S,Aghamiri SM,Kamali-Asl A,Yashiro W

    更新日期:2017-09-01 00:00:00

  • Influence of the surface averaging procedure of the current density in assessing compliance with the ICNIRP low-frequency basic restrictions by means of numerical techniques.

    abstract::Although the calculation of the surface average of the low-frequency current density distribution over a cross-section of 1 cm2 is required by ICNIRP guidelines, no reference averaging algorithm is indicated, neither in the ICNIRP guidelines nor in the Directive 2004/40/EC that is based on them. The lack of a general ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/15/013

    authors: Zoppetti N,Andreuccetti D

    更新日期:2009-08-07 00:00:00

  • Comparison of SAR and induced current densities in adults and children exposed to electromagnetic fields from electronic article surveillance devices.

    abstract::Electronic article surveillance (EAS) devices are widely used in most stores as anti-theft systems. In this work, the compliance with international guidelines in the human exposure to these devices is analysed by using the finite-difference time-domain (FDTD) method. Two sets of high resolution numerical phantoms of d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/009

    authors: Martínez-Búrdalo M,Sanchis A,Martín A,Villar R

    更新日期:2010-02-21 00:00:00

  • The effect of authentic metallic implants on the SAR distribution of the head exposed to 900, 1800 and 2450 MHz dipole near field.

    abstract::As the use of radiofrequency (RF) electromagnetic (EM) fields has increased along with increased use of wireless communication, the possible related health risks have also been widely discussed. One safety aspect is the interaction of medical implants and RF devices like mobile phones. In the literature, effects on ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/001

    authors: Virtanen H,Keshvari J,Lappalainen R

    更新日期:2007-03-07 00:00:00

  • Correction factors for parallel-plate chambers used in plastic phantoms in electron dosimetry.

    abstract::In electron beam dosimetry using parallel-plate chambers solid phantoms are sometimes necessary. To obtain the dose to water from the ionization obtained in the solid phantom, fluence correction factors and perturbation factors have to be applied. In this study fluence factors in a perturbation free geometry have been...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/11/007

    authors: Nilsson B,Montelius A,Andreo P,Johansson J

    更新日期:1997-11-01 00:00:00

  • Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

    abstract::A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4353

    authors: van Hoof SJ,Granton PV,Landry G,Podesta M,Verhaegen F

    更新日期:2012-07-07 00:00:00

  • Dosimetric accuracy of planning and delivering small proton therapy fields.

    abstract::A detailed Monte Carlo model of a proton therapy treatment head was commissioned to simulate the delivery of small field proton treatments. Small fields are challenging in the planning and quality assurance process because of aperture scattering and dosimetric disequilibrium. Four patients with small fields used in al...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/003

    authors: Bednarz B,Daartz J,Paganetti H

    更新日期:2010-12-21 00:00:00

  • Predicting voxel-level dose distributions for esophageal radiotherapy using densely connected network with dilated convolutions.

    abstract::This work aims to develop a voxel-level dose prediction framework by integrating distance information between PTV and OARs, as well as image information, into a densely-connected network (DCNN). Firstly, a four-channel feature map, consisting of a PTV image, an OAR image, a CT image, and a distance image, is construct...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba87b

    authors: Zhang J,Liu S,Yan H,Li T,Mao R,Liu J

    更新日期:2020-10-21 00:00:00

  • New materials for dielectric simulation of tissues.

    abstract::Two novel materials have been developed to simulate the dielectric properties of human muscle and fat at 1000 MHz. These materials, which are based on ethanediol set with gelatine, are easily made and have good mechanical properties. The complex permittivity, epsilon *, of each material was measured with an open-ended...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/12/002

    authors: Robinson MP,Richardson MJ,Green JL,Preece AW

    更新日期:1991-12-01 00:00:00

  • A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode.

    abstract::Respiratory gating based on external surrogates is performed in many clinics. We have developed a new technique for treatment verification using an electronic portal imaging device (EPID) in cine mode for gated 3D conformal therapy. Implanted radiopaque fiducial markers inside or near the target are required for this ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/16/002

    authors: Berbeco RI,Neicu T,Rietzel E,Chen GT,Jiang SB

    更新日期:2005-08-21 00:00:00

  • Diffusion coefficient for photon transport in turbid media.

    abstract::Light propagation in a turbid medium is considered using the linear transport equation. The existence of a diffusion length is proved for the Henyey-Greenstein scattering kernel for all absorption ratios. Numerical methods are given that allow accurate computation of the diffusion coefficient quite easily. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/23/012

    authors: Sahni DC,Dahl EB,Sjöstrand NG

    更新日期:2003-12-07 00:00:00

  • Investigation of systematic uncertainties in Monte Carlo-calculated beam quality correction factors.

    abstract::Modern Monte Carlo codes allow for the calculation of ion chamber specific beam quality correction factors k(Q), which are needed for dosimetry in radiotherapy. While statistical (type A) uncertainties of the calculated data can be minimized sufficiently, the influence of systematic (type B) uncertainties is mostly un...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/16/S04

    authors: Wulff J,Heverhagen JT,Zink K,Kawrakow I

    更新日期:2010-08-21 00:00:00

  • The quality of ionising radiations emitted by radionuclides incorporated into mammalian cells.

    abstract::Radionuclides which decay by electron capture accompanied by Auger electron cascades, or by beta emission are thought to be excessively damaging when incorporated into the molecular structure of mammalian cell nuclei and thereby pose a radiation hazard which is not assessable by conventional dosimetry. Survival data, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/7/003

    authors: Younis AR,Watt DE

    更新日期:1989-07-01 00:00:00

  • Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.

    abstract::We present the results of utilizing aligned anatomical information from CT images to locally adjust image smoothness during the reconstruction of three-dimensional (3D) whole-body positron emission tomography (PET) data. The ability of whole-body PET imaging to detect malignant neoplasms is becoming widely recognized....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/1/301

    authors: Comtat C,Kinahan PE,Fessler JA,Beyer T,Townsend DW,Defrise M,Michel C

    更新日期:2002-01-07 00:00:00

  • The dose--response relation for rat spinal cord paralysis analyzed in terms of the effective size of the functional subunit.

    abstract::Radiobiological models for estimating normal tissue complication probability (NTCP) are increasingly used in order to quantify or optimize the clinical outcome of radiation therapy. A good NTCP model should fulfill at least the following two requirements: (a) it should predict the sigmoid shape of the corresponding do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/016

    authors: Adamus-Górka M,Mavroidis P,Brahme A,Lind BK

    更新日期:2008-11-21 00:00:00

  • Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors.

    abstract::Beam tracking with scanned carbon ion radiotherapy achieves highly conformal target dose by steering carbon pencil beams to follow moving tumors using real-time magnetic deflection and range modulation. The purpose of this study was to evaluate the robustness of target dose coverage from beam tracking in light of posi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/4/1717

    authors: Eley JG,Newhauser WD,Richter D,Lüchtenborg R,Saito N,Bert C

    更新日期:2015-02-21 00:00:00

  • An investigation of a PRESAGE® in vivo dosimeter for brachytherapy.

    abstract::Determining accurate in vivo dosimetry in brachytherapy treatment with high dose gradients is challenging. Here we introduce, investigate, and characterize a novel in vivo dosimeter and readout technique with the potential to address this problem. A cylindrical (4 mm × 20 mm) tissue equivalent radiochromic dosimeter P...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/14/3893

    authors: Vidovic AK,Juang T,Meltsner S,Adamovics J,Chino J,Steffey B,Craciunescu O,Oldham M

    更新日期:2014-07-21 00:00:00