Three-dimensional localisation based on projectional and tomographic image correlation: an application for digital tomosynthesis.

Abstract:

:Accurate three-dimensional tumor localisation in Radiotherapy, is critical to the treatment outcome, particularly when high dose gradients are present. A number of techniques have been proposed for the localisation of anatomical structures or markers. The present study proposes an approach to a concurrent maximisation of localisation accuracy and efficiency by correlation of tomographic and projectional images. The method introduces an element of direct verification and interactive optimisation of the process. Tomographic images are used for the identification of a point of interest. Its position is computed within the treatment co-ordinate system and verification of this position is achieved by obtaining the beam's eye view of the identified point on two projection radiographs. The key element of the approach is that all images used should be part of one single image data set. The implementation of this localisation method, as part of the functionality of a Digital Tomosynthesis prototype, has provided an integrated facility for localisation, of optimised accuracy and precision, while easy and efficient to use. The considerations are general and apply in principle to any imaging system that can augment tomographic images with projections.

journal_name

Med Eng Phys

authors

Messaris G,Kolitsi Z,Badea C,Pallikarakis N

doi

10.1016/s1350-4533(99)00015-6

subject

Has Abstract

pub_date

1999-03-01 00:00:00

pages

101-9

issue

2

eissn

1350-4533

issn

1873-4030

pii

S1350453399000156

journal_volume

21

pub_type

杂志文章
  • Validation of a finite element model of a unilateral external fixator in a rabbit tibia defect model.

    abstract::In case of large segmental defects in load-bearing bones, an external fixator is used to provide mechanical stability to the defect site. The overall stiffness of the bone-fixator system is determined not only by the fixator design but also by the way the fixator is mounted to the bone. This stiffness is an important ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.006

    authors: Karunratanakul K,Kerckhofs G,Lammens J,Vanlauwe J,Schrooten J,Van Oosterwyck H

    更新日期:2013-07-01 00:00:00

  • A nonparametric feature for neonatal EEG seizure detection based on a representation of pseudo-periodicity.

    abstract::Automated methods of neonatal EEG seizure detection attempt to highlight the evolving, stereotypical, pseudo-periodic, nature of EEG seizure while rejecting the nonstationary, modulated, coloured stochastic background in the presence of various EEG artefacts. An important aspect of neonatal seizure detection is, there...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.08.001

    authors: Stevenson NJ,O'Toole JM,Rankine LJ,Boylan GB,Boashash B

    更新日期:2012-05-01 00:00:00

  • Estimation of pulsatile cerebral arterial blood volume based on transcranial doppler signals.

    abstract:OBJECTIVE:Mathematical modeling of cerebral hemodynamics by descriptive equations can estimate the underlying pulsatile component of cerebral arterial blood volume (CaBV). This way, clinical monitoring of changes in cerebral compartmental compliances becomes possible. Our aim is to validate the most adequate method of ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.019

    authors: Calviello LA,Zeiler FA,Donnelly J,Uryga A,de Riva N,Smielewski P,Czosnyka M

    更新日期:2019-12-01 00:00:00

  • Computation of the elastic properties of a resin impregnated wire mesh by the means of a homogenisation procedure.

    abstract::The present paper presents a homogenisation technique applied to the problem of calculating equivalent material properties of a resin impregnated wire mesh. Although this type of material can be expected to possess, in general, a four-fold axis of rotational symmetry, it was found that a transversally isotropic model ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00065-5

    authors: Hübsch PF,Middleton J,Knox J

    更新日期:2000-09-01 00:00:00

  • The integrated design of mechanical bi-leaflet prosthetic heart valves.

    abstract::A flow model utilizing an irrotational, inviscid algorithm of vortex-ring elements simulating the leaflets and source/sink elements simulating the aortic root coupled with a boundary layer model has been developed to model the internal flow phenomena of bi-leaflet mechanical heart valves implanted in the aortic root. ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00075-5

    authors: David T,Hsu CH

    更新日期:1996-09-01 00:00:00

  • Use of charged membranes to control interference by body chemicals in a glucose biosensor.

    abstract::The prerequisite for the continuous in vivo monitoring of glucose concentration is the development of an implantable glucose sensor with long-term stability. A new enzyme electrode concept featuring fluid-state glucose oxidase modified carbon powder along with a cross-linked glucose oxidase enzyme layer has been devel...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(90)90008-v

    authors: Vaidya R,Wilkins E

    更新日期:1994-09-01 00:00:00

  • Application of time-varying analysis to diagnostic needle electromyography.

    abstract::Quantification in clinical, diagnostic electromyography (EMG) currently includes motor unit action potential (MUAP) analysis and interference pattern analysis. Early efforts to examine the frequency/power spectra of the interference pattern showed modest value but the technique was not developed further. This paper re...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.07.017

    authors: Sheean GL

    更新日期:2012-03-01 00:00:00

  • Envelopment filter and K-means for the detection of QRS waveforms in electrocardiogram.

    abstract::The electrocardiogram (ECG) is a well-established technique for determining the electrical activity of the heart and studying its diseases. One of the most common pieces of information that can be read from the ECG is the heart rate (HR) through the detection of its most prominent feature: the QRS complex. This paper ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.03.019

    authors: Merino M,Gómez IM,Molina AJ

    更新日期:2015-06-01 00:00:00

  • Real time monitoring of muscular fatigue from dynamic surface myoelectric signals using a complex covariance approach.

    abstract::A method aimed at the real-time monitoring of muscular fatigue was implemented and optimized. The method is based on an estimate of the complex covariance function in order to evaluate, in real time, the mean frequency of the myoelectric signal spectrum. Real-time implementation is guaranteed by a recursive computatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00049-1

    authors: Conforto S,D'Alessio T

    更新日期:1999-05-01 00:00:00

  • Kinematics of the human pelvis following open book injury.

    abstract::The objective of this study is to determine the three dimensional kinematics of the human pelvis including both sacroiliac joints following a simulated open book injury induced on cadavers by applying anterior-posterior compressive loads to the pelvis. An electromagnetic digitizing and motion tracking system was utili...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00196-0

    authors: Hefzy MS,Ebraheim N,Mekhail A,Caruntu D,Lin H,Yeasting R

    更新日期:2003-05-01 00:00:00

  • Computed tomography (CT)-compatible remote center of motion needle steering robot: Fusing CT images and electromagnetic sensor data.

    abstract::Lung cancer is the most common cause of cancer-related death, and early detection can reduce the mortality rate. Patients with lung nodules greater than 10 mm usually undergo a computed tomography (CT)-guided biopsy. However, aligning the needle with the target is difficult and the needle tends to deflect from a strai...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.04.009

    authors: Shahriari N,Heerink W,van Katwijk T,Hekman E,Oudkerk M,Misra S

    更新日期:2017-07-01 00:00:00

  • Design of a biodegradable plate for femoral shaft fracture fixation.

    abstract::Biodegradable materials have been generating increasing bit of interest in biomedical applications and associated research. The evolution of implants made up of such materials (Mg-alloys, etc.) has the potential to be a game changer in fracture surgeries. These implants are essentially made up of a plate and a number ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.05.010

    authors: Chandra G,Pandey A,Pandey S

    更新日期:2020-07-01 00:00:00

  • Effect of different inertial parameter sets on joint moment calculation during stair ascending and descending.

    abstract::The reliability of internal joint moment calculation in gait analysis during daily living activities is fundamental for clinical decisions based on joint function. This calculation, obtained by means of the inverse dynamics, depends on several modelling factors, such as assumptions on the segments and on the relevant ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.12.002

    authors: Fantozzi S,Stagni R,Cappello A,Leardini A

    更新日期:2005-07-01 00:00:00

  • A complete, non-lumped, and verifiable set of upper body segment parameters for three-dimensional dynamic modeling.

    abstract::Dynamic models of the human trunk have been extensively used to investigate the biomechanics of lower back pain and postural instability in different populations. Despite their diverse applications, previous models rely on intrinsic upper body segment parameters (UBSP), e.g., each segment's mass-inertia characteristic...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.09.008

    authors: Vette AH,Yoshida T,Thrasher TA,Masani K,Popovic MR

    更新日期:2011-01-01 00:00:00

  • Measurement of thermal conductivity of bovine cortical bone.

    abstract::The thermal conductivity of cortical bone was characterized experimentally. Specimens were taken from the mid-diaphysis of bovine femora, and the rate of heat transfer was measured in three orthogonal directions. The conductivity was found to be 0.58+/-0.018 W/mK in the longitudinal direction, 0.53+/-0.030 W/mK in the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00003-0

    authors: Davidson SR,James DF

    更新日期:2000-12-01 00:00:00

  • In-vitro validation of a non-invasive dual fluoroscopic imaging technique for measurement of the hip kinematics.

    abstract::Measurement of accurate in vivo hip joint kinematics in 6-DOF is difficult. Few studies have reported non-invasive measurements of the hip kinematics. The objective of this study was to validate a non-invasive dual fluoroscopic imaging system (DFIS) for measurement of hip kinematics. Bi-lateral hip joints of a cadaver...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.004

    authors: Lin H,Wang S,Tsai TY,Li G,Kwon YM

    更新日期:2013-03-01 00:00:00

  • How measurement artifacts affect cerebral autoregulation outcomes: A technical note on transfer function analysis.

    abstract::Cerebral autoregulation (CA) is the mechanism that aims to maintain adequate cerebral perfusion during changes in blood pressure (BP). Transfer function analysis (TFA), the most reported method in literature to quantify CA, shows large between-study variability in outcomes. The aim of this study is to investigate the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.001

    authors: Meel-van den Abeelen AS,de Jong DL,Lagro J,Panerai RB,Claassen JA

    更新日期:2016-05-01 00:00:00

  • Modelization of a self-opening peripheral neural interface: a feasibility study.

    abstract::In this paper a self-opening intrafascicular neural interface (SELINE) has been modeled using both a theoretical approach and a Finite Element (FE) analysis. This innovative self opening interface has several potential advantages such as: higher selectivity due to its three-dimensional structure and efficient anchorag...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.001

    authors: Cutrone A,Sergi PN,Bossi S,Micera S

    更新日期:2011-12-01 00:00:00

  • Development of a home ankle exerciser.

    abstract::A portable, lightweight home ankle exerciser was designed and built by the Biomedical Engineering Department of University Hospital in London, Ontario, Canada. The ankle exerciser incorporates several unique features that overcomes the drawbacks of exercise equipment presently available. For optimal muscle strengtheni...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00057-7

    authors: Petrosenko RD,Vandervoort AA,Chesworth BM,Porter MM,Campbell GJ

    更新日期:1996-06-01 00:00:00

  • An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones.

    abstract::Subject-specific FE-models of human long bones have to predict mechanical parameters with sufficient accuracy to be applicable in a clinical setting. One of the main aspects in subject-specific FE-models of bones regarding accuracy is the modeling of the material inhomogeneity. The goal of this study was therefore to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.022

    authors: Eberle S,Göttlinger M,Augat P

    更新日期:2013-07-01 00:00:00

  • Pilot study of a surgical robot system for zygomatic implant placement.

    abstract::Zygomatic implant technology has been regarded as an alternative treatment to massive grafting surgery in the severe atrophic maxillary. Nowadays, the assistant method with a real-time surgical navigation has been applied to reduce the risks of zygomatic implant placement. However, the accuracy of the complex operatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.020

    authors: Cao Z,Qin C,Fan S,Yu D,Wu Y,Qin J,Chen X

    更新日期:2020-01-01 00:00:00

  • Functional evaluation of natural sensory feedback incorporated in a hand grasp neuroprosthesis.

    abstract::We investigated whether automatic control of a hand grasp neuroprosthesis by means of signals from natural sensors in the skin of the index finger can mimic the natural control of grasp force in an important task of daily living, namely eating. We designed a simulated eating task with the same ratio of rest and activi...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.03.002

    authors: Inmann A,Haugland M

    更新日期:2004-07-01 00:00:00

  • A fast responding combined direct and indirect calorimeter for human subjects.

    abstract::The construction and performance of a 5.4 m3 combined direct and indirect calorimeter for human subjects is described. The calorimeter was constructed for studies on human subjects primarily undergoing fast alterations in heat production and heat losses, e.g. after a meal or during physical exercise. A heat sink and a...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00037-x

    authors: Faber P,Lammert O,Johansen O,Garby L

    更新日期:1998-06-01 00:00:00

  • Predicting fracture using 2D finite element modelling.

    abstract::A decrease in bone density at the hip or spine has been shown to increase the risk of fracture. A limitation of the bone mineral density (BMD) measurement is that it provides only a measure of a bone sample's average density when projected onto a 2D surface. Effectively, what determines bone fracture is whether an app...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.08.008

    authors: MacNeil JA,Adachi JD,Goltzman D,Josse RG,Kovacs CS,Prior JC,Olszynski W,Davison KS,Kaiser SM,CaMos Research Group.

    更新日期:2012-05-01 00:00:00

  • Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems.

    abstract::Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Ti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.011

    authors: Jauch SY,Coles LG,Ng LV,Miles AW,Gill HS

    更新日期:2014-09-01 00:00:00

  • Electrochemistry of nanoscale DNA surface films on carbon.

    abstract::A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2006.05.009

    authors: Oliveira-Brett AM,Paquim AM,Diculescu VC,Piedade JA

    更新日期:2006-12-01 00:00:00

  • Suspension microarrays for the identification of the response patterns in hyperinflammatory diseases.

    abstract::Miniaturized and parallelized sandwich immunoassays allow the simultaneous analysis of a variety of parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. To study inflammatory diseases, protein arrays can be used to an...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.01.003

    authors: Hsu HY,Wittemann S,Schneider EM,Weiss M,Joos TO

    更新日期:2008-10-01 00:00:00

  • Measurement of the chondrocyte membrane permeability to Me2SO, glycerol and 1,2-propanediol.

    abstract::The addition of cryopreservative agents (CPAs) to chondrocytes and natural and engineered cartilage is critical to protect the cells and tissues from freezing damage during cryopreservation, but this may cause cell damage, e.g. by osmotic shock. The damage could be minimized by the control of the cell volume excursion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00073-0

    authors: Xu X,Cui Z,Urban JP

    更新日期:2003-09-01 00:00:00

  • A computational assessment of the hemodynamic effects of crossed and non-crossed bifurcated stent-graft devices for the treatment of abdominal aortic aneurysms.

    abstract::There are several issues attributed with abdominal aortic aneurysm endovascular repair. The positioning of bifurcated stent-grafts (SG) may affect SG hemodynamics. The hemodynamics and geometrical parameters of crossing or non-crossing graft limbs have not being totally accessed. Eight patient-specific SG devices and ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.011

    authors: Stefanov F,McGloughlin T,Morris L

    更新日期:2016-12-01 00:00:00

  • A decentralized adaptive fuzzy robust strategy for control of upright standing posture in paraplegia using functional electrical stimulation.

    abstract::In this paper, we present a novel decentralized robust methodology for control of quiet upright posture during arm-free paraplegic standing using functional electrical stimulation (FES). Each muscle-joint complex is considered as a subsystem and individual controllers are designed for each one. Each controller operate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.013

    authors: Kobravi HR,Erfanian A

    更新日期:2012-01-01 00:00:00