Abstract:
:We investigated whether automatic control of a hand grasp neuroprosthesis by means of signals from natural sensors in the skin of the index finger can mimic the natural control of grasp force in an important task of daily living, namely eating. We designed a simulated eating task with the same ratio of rest and activity as was found on average in a video analysis of three meals consumed in a social environment. An instrumented fork measured grasp force as well as the force in the long axis and perpendicular to the long axis at the tip of the fork. The simulated eating task was performed by a tetraplegic volunteer using a hand grasp neuroprosthesis both with and without use of feedback from the natural sensors. Further, 10 able-bodied volunteers performed the task with the same (lateral) grasp as the tetraplegic volunteer to obtain measures for improving the control strategy of the hand grasp neuroprosthesis. We have shown that a hand grasp neuroprosthesis incorporating natural sensory feedback can to some extent mimic the natural application of grasp force on a fork during simulated eating. The mean grasp force during active phases was higher than the mean grasp force during inactive phases. The mean grasp force applied during a simulated eating task was reduced by using the system with sensory feedback compared to using the system without sensory feedback.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Inmann A,Haugland Mdoi
10.1016/j.medengphy.2004.03.002subject
Has Abstractpub_date
2004-07-01 00:00:00pages
439-47issue
6eissn
1350-4533issn
1873-4030pii
S1350453304000396journal_volume
26pub_type
临床试验,杂志文章abstract::Surface electromyography (sEMG) has dominated upper-limb prosthesis control for decades due to its simplicity and effectiveness [1-3]. However, the inherent variability of EMG signal hinders the flexible and accurate control of advanced multi-functional prosthesis. This study is an attempt to use ultrasonography (US) ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.11.005
更新日期:2020-01-01 00:00:00
abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00003-5
更新日期:1999-12-01 00:00:00
abstract::Multi-fragmented fractures of the proximal humerus are difficult to treat, especially in the case of osteoporotic bone. Intra-operative risks include cartilage damage when inserting multiple screws. A common post-operative complication is distal-varus collapse of the head. The aim of this study was to investigate if a...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.06.002
更新日期:2020-08-01 00:00:00
abstract::We present single fibre heart activity model (SFHAM) based on the current flow through the five bunches of fibres of the cardiac muscle (CM). The five effective fibres are identified and assigned to the appropriate segments of CM. Analytical functions describing ionic flows along the fibres are derived and proposed. T...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.08.007
更新日期:2009-12-01 00:00:00
abstract::It is important to be able to quantify changes in gait pattern accurately in order to understand the clinical implications of surgery or rehabilitation. Although supervised feed-forward backpropagation neural networks are very efficient in many pattern-recognition tasks, the genetic algorithm neural network (GANN), wh...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00011-4
更新日期:2000-01-01 00:00:00
abstract::To better understand the mechanisms underlying distal radius fracture we have developed finite element models to predict radius bone strain and fracture strength under loading conditions simulating a fall. This study compares experimental surface strains and fracture loads of the distal radius with specimen-specific f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.07.016
更新日期:2012-04-01 00:00:00
abstract::A method for leakage effect reduction by a modification of the classical spectra obtained Discrete Fourier Transform is proposed. The properties of the new method are investigated analytically and validated through synthesized signals, processed by the developed complete computational procedure. This combines the prop...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(97)00006-4
更新日期:1997-07-01 00:00:00
abstract::Successful treatment of tumors with motion-adaptive radiotherapy requires accurate prediction of respiratory motion, ideally with a prediction horizon larger than the latency in radiotherapy system. Accurate prediction of respiratory motion is however a non-trivial task due to the presence of irregularities and intra-...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.04.021
更新日期:2016-08-01 00:00:00
abstract::We present a finite element based simulation and analysis method to describe the spatial extent of stimulation and the effects of electrode-tissue interactions in subretinal prostheses. In particular, we estimate the threshold stimulation current needed to depolarise and evoke action potentials in the ganglion cells t...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.01.015
更新日期:2011-07-01 00:00:00
abstract::In contrast enhanced magnetic resonance imaging (MRI) and computed tomography (CT), the equilibrium distribution of anionic contrast agent is expected to reflect the fixed charged density (FCD) of articular cartilage. Diffusion is mainly responsible for the transport of contrast agents into cartilage. In osteoarthriti...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.06.002
更新日期:2010-10-01 00:00:00
abstract::The purpose of this study is to demonstrate a new MRI compatible loading device capable of reconstructing realistic loading scenarios of the human foot for research in the field of foot biomechanics. This device has two different configurations: one used to compress the forefoot and one to bend the metatarsophalangeal...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.06.006
更新日期:2014-09-01 00:00:00
abstract::This study introduced a shape memory alloy (SMA)-based smart knee spacer for total knee arthroplasty (TKA). Subsequently, a 3D CAD model of a smart tibial component of TKA was designed in Solidworks software, and verified using a finite element analysis in ANSYS Workbench. The two major properties of the SMA (NiTi), t...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2018.03.001
更新日期:2018-05-01 00:00:00
abstract::Observational balance tests (e.g., Berg Balance Scale) are used to evaluate fall-risk. However, they tend to be subjective, and their reliability and sensitivity can be limited. The use of in-lab equipment for objective balance evaluation has not been common in clinical practice, due to the requirement of an equipped ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.10.018
更新日期:2020-03-01 00:00:00
abstract::In the fields of medicine and biomechanics, MEMS accelerometers are increasingly used to perform activity recognition by directly measuring acceleration; to calculate speed and position by numerical integration of the signal; or to estimate the orientation of body parts in combination with gyroscopes. For some of thes...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2016.08.004
更新日期:2016-11-01 00:00:00
abstract::Investigations into the effects of sterilization on a new biomechanical pressure sensor are necessary before contemplating in vivo use. Ten, designated Experimental, "K-Scan" digital pressure sensor arrays were sterilized with ethylene oxide gas (EtO), and their ability to accurately and reproducibly measure an applie...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(03)00119-x
更新日期:2003-11-01 00:00:00
abstract::The aim of this study was to evaluate comparatively five methods for automating mesh generation (AMG) when used to mesh a human femur. The five AMG methods considered were: mapped mesh, which provides hexahedral elements through a direct mapping of the element onto the geometry; tetra mesh, which generates tetrahedral...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(97)00049-0
更新日期:1998-01-01 00:00:00
abstract:BACKGROUND:Verified and validated CT-based high-order finite element (FE) methods were developed that predict accurately the mechanical response of patient-specific intact femurs. Here we extend these capabilities to human femurs undergoing a total hip replacement using cemented prostheses. METHODS:A fresh-frozen huma...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.09.007
更新日期:2013-07-01 00:00:00
abstract::Artificial blood pumps play an increasingly important role in the treatment of end-stage cardiac failure. The fluid dynamics of blood flow through such devices crucially affects their clinical effectiveness. Specifically, if the flow of blood stagnates or slowly re-circulates thrombus formation can occur and the avoid...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00023-0
更新日期:2000-04-01 00:00:00
abstract::This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms m...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.09.009
更新日期:2016-11-01 00:00:00
abstract::Fetal movement is one index of fetal well-being. We designed and built a new recorder based on fetal movement acceleration measurement (FMAM). The FMAM recorder has a newly developed, capacitive acceleration sensor that can detect the oscillations of the maternal abdominal wall caused by fetal movements. In this study...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.09.001
更新日期:2012-06-01 00:00:00
abstract::Bone-attached robots and microstereotactic frames, intended for deep brain stimulation and minimally invasive cochlear implantation, typically attach to a patient's skull via bone anchors. A rigid and reliable link between such devices and the skull is mandatory in order to fulfill the high accuracy demands of minimal...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.02.012
更新日期:2015-05-01 00:00:00
abstract::The pulse pressure waveform has, for long, been known as a fundamental biomedical signal and its analysis is recognized as a non-invasive, simple, and resourceful technique for the assessment of arterial vessels condition observed in several diseases. In the current paper, waveforms from non-invasive optical probe tha...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.07.014
更新日期:2014-11-01 00:00:00
abstract::This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The we...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00004-6
更新日期:1998-04-01 00:00:00
abstract::Finite element analysis (FEA) of bones scanned with Quantitative Computed Tomography (QCT) can improve early detection of osteoporosis. The accuracy of these models partially depends on the assigned material properties, but anisotropy of the trabecular bone cannot be fully captured due to insufficient resolution of QC...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.08.010
更新日期:2016-11-01 00:00:00
abstract::A numerical model was developed to predict the dynamics of a solid particle in a poststenotic blood vessel region. The flow through a 3D axisymmetric stenosis with 75% reduction in cross-section area was considered for inlet Reynolds numbers of 500 and 1000, which corresponds to typical values for the blood flow in hu...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.11.003
更新日期:2012-09-01 00:00:00
abstract::Understanding morphological features that characterize normal hip joint is critical and necessary for a more comprehensive definition of pathological presentations, such as femoroacetabular impingement and hip dysplasia. Based on anatomical observations that articular surfaces of synovial joints are better represented...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2018.07.001
更新日期:2018-09-01 00:00:00
abstract::The purpose of this study was to determine the accuracy of a radiographic model-based tracking technique that measures the three-dimensional in vivo motion of the tibio-femoral joint during running. Tantalum beads were implanted into the femur and tibia of three subjects and computed tomography (CT) scans were acquire...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/j.medengphy.2008.03.003
更新日期:2009-01-01 00:00:00
abstract::In laboratory animals as well as in human beings a depth of anaesthesia, where the subject has no pain or recall of events from the surgery, should be provided. Haemodynamic parameters such as heart rate and blood pressure are not a guarantee for an optimal depth of anaesthesia, especially when using neuromuscular blo...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00089-7
更新日期:1998-12-01 00:00:00
abstract::Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00081-3
更新日期:2000-11-01 00:00:00
abstract::We developed an analytical biomechanical model for leg-extension equipment and the associated knee-extension/flexion exercises. The shear component, phi(t), of the tibiofemoral joint load was calculated taking into account all the fundamental elements of the equipment mechanics (resistance pad placement, cam/pulley sy...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2007.12.012
更新日期:2008-10-01 00:00:00