Abstract:
:In this paper, we present a novel decentralized robust methodology for control of quiet upright posture during arm-free paraplegic standing using functional electrical stimulation (FES). Each muscle-joint complex is considered as a subsystem and individual controllers are designed for each one. Each controller operates solely on its associated subsystem, with no exchange of information between them, and the interaction between the subsystems are taken as external disturbances. In order to achieve robustness with respect to external disturbances, unmodeled dynamics, model uncertainty and time-varying properties of muscle-joint dynamics, a robust control framework is proposed. The method is based on the synergistic combination of an adaptive nonlinear compensator with sliding mode control (SMC). Fuzzy logic system is used to represent unknown system dynamics for implementing SMC and an adaptive updating law is designed for online estimating the system parameters such that the global stability and asymptotic convergence to zero of tracking errors is guaranteed. The proposed controller requires no prior knowledge about the dynamics of system to be controlled and no offline learning phase. The results of experiments on three paraplegic subjects show that the proposed control strategy is able to maintain the vertical standing posture using only FES control of ankle dorsiflexion and plantarflexion without using upper limbs for support and to compensate the effect of external disturbances and muscle fatigue.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Kobravi HR,Erfanian Adoi
10.1016/j.medengphy.2011.06.013subject
Has Abstractpub_date
2012-01-01 00:00:00pages
28-37issue
1eissn
1350-4533issn
1873-4030pii
S1350-4533(11)00151-2journal_volume
34pub_type
杂志文章abstract::Contact interactions between the hand and handle, such as the contact surface softness and contact surface curvature, will affect both physical effort and musculoskeletal fatigue, thereby the comfort and safety of power tool operations. Previous models of hand gripping can be categorized into two groups: multi-body dy...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.03.007
更新日期:2014-07-01 00:00:00
abstract::The liquid ventilation (LV) technique was previously demonstrated to be a valuable alternative to ordinary gas ventilation, particularly for newborn patients with severely distressed lungs. This work describes a mathematical model of gas transfer phenomena occurring within the lungs of a preterm newborn baby ventilate...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00041-0
更新日期:1997-03-01 00:00:00
abstract::CT data has been widely used in the finite element modeling of bone. It can provide useful information on the geometrical topology and material properties of bone. Based on CT data, the assignment of bone material properties to finite element meshes is a fundamental step in the model generation. Most work done in this...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.06.003
更新日期:2006-04-01 00:00:00
abstract::Different probes are used in dermato-cosmetic research to measure the electrical properties of the skin. The principle governing the choice of the geometry and material of the measuring probe is not well defined in the literature and some device's measuring principles are not accessible for the scientific community. T...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.02.008
更新日期:2012-12-01 00:00:00
abstract::In this study, we applied multi-channel mechanomyographic (MMG) recordings in combination with linear and nonlinear analyses to investigate muscular and musculotendinous effects of high intensity eccentric exercise. Twelve accelerometers arranged in a 3 × 4 matrix over the dominant elbow muscles were used to detect MM...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.09.003
更新日期:2014-12-01 00:00:00
abstract::Children with severe physical disabilities often require a range of technological devices to aid them with the fundamental tasks carried out in everyday life. These tasks areas may include mobility, communication, environment control and computer access for education. The most efficient, and often the most cost-effect...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(94)90043-4
更新日期:1994-05-01 00:00:00
abstract::Recently, surgeons have begun to treat serious congenital craniofacial deformities including craniosynostoses with mechanical devices that gradually distract the skull. As a prospective means of treatment planning for such complex deformities, FE models derived from routine preoperative CT scans (CT/FEA) would provide...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00053-8
更新日期:1998-11-01 00:00:00
abstract::We developed a device for an objective measurement of non-nutritive sucking (NNS). NNS is newborns' spontaneous action that is a predictor of their neural system development and can be adopted as an intervention to train oral feeding skills in preterms. Two miniaturized digital pressure sensors were embedded into a co...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.12.013
更新日期:2016-04-01 00:00:00
abstract::This work proposes the use of miniature wireless inertial sensors as an objective tool for the diagnosis of ADHD. The sensors, consisting of both accelerometers and gyroscopes to measure linear and rotational movement, respectively, are used to characterize the motion of subjects in the setting of a psychiatric consul...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.02.023
更新日期:2014-07-01 00:00:00
abstract::This article reviews the role of cavitation in the therapeutic applications of ultrasound and laser surgery, and the cavitation effects in mechanical heart valves. Whenever laser pulses are used to ablate or disrupt tissue in a liquid environment, cavitation bubbles are produced which interact with the tissue. The int...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2009.03.007
更新日期:2009-09-01 00:00:00
abstract::The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influen...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.10.015
更新日期:2017-02-01 00:00:00
abstract::Long distance travel is associated with increased risk of deep vein thrombosis (DVT). There is an increased risk of travel related DVT in passengers with a predisposition to thrombosis. Assisting blood circulation in the lower limb will reduce the risk of DVT. Leg exercises are recommended as a DVT preventative measur...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.02.002
更新日期:2005-10-01 00:00:00
abstract::Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and d...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.09.007
更新日期:2014-01-01 00:00:00
abstract::Frozen clamps can hold tendons and ligaments tightly and transmit high loads, from 4 kN to 13 kN, without slippage, yet they are complex and expensive. The existing non-frozen serrated jaw clamp is simple to fabricate and use, but the maximal tensile force it can sustain is only about 2.5 kN, which is not enough in ma...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.11.019
更新日期:2012-05-01 00:00:00
abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00020-0
更新日期:2001-03-01 00:00:00
abstract::Sclerosis rim surrounding the necrotic area is commonly found in necrotic femoral head, but the biomechanical function of sclerosis rim has received relatively little attention. Little is known about the formation and natural history of sclerosis rim. In the present work, we assume that the necrotic change may trigger...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.09.005
更新日期:2015-12-01 00:00:00
abstract::Right ventricle ejection fraction (RVEF) is clinically used to evaluate right ventricular function. The thermodilution method can be modified to estimate the RVEF. However, this method requires a thermistor with a fast time response in order to yield correct estimates. Digital signal processing techniques that were de...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00026-7
更新日期:2002-06-01 00:00:00
abstract::Computational fluid dynamics (CFD) simulations quantifying thoracic aortic flow patterns have not included disturbances from the aortic valve (AoV). 80% of patients with aortic coarctation (CoA) have a bicuspid aortic valve (BAV) which may cause adverse flow patterns contributing to morbidity. Our objectives were to d...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.07.015
更新日期:2013-06-01 00:00:00
abstract::The standard camera- and force plate-based set-up for motion analysis suffers from the disadvantage of being limited to laboratory settings. Since adaptive algorithms are able to learn the connection between known inputs and outputs and generalise this knowledge to unknown data, these algorithms can be used to leverag...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.10.001
更新日期:2020-12-01 00:00:00
abstract::Easy insertion of the implant and stable bone purchase is essential for an ideal dental implantation. At the implant tip, the cutting flutes and conical profile are respectively designed to reduce insertion resistance and facilitate the initial insertion. However, the tapered tip might reduce the self-tapping and bone...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.09.021
更新日期:2012-09-01 00:00:00
abstract::This study presents a theoretical model of the general stress state found in helical implantable leads in bending. The model accurately predicts stress in large filarity coils made from clad wire. The stress is predicted using flexural rigidity of the coil and is developed to include the effects of coil pitch and the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00022-7
更新日期:1997-10-01 00:00:00
abstract::The construction and performance of a 5.4 m3 combined direct and indirect calorimeter for human subjects is described. The calorimeter was constructed for studies on human subjects primarily undergoing fast alterations in heat production and heat losses, e.g. after a meal or during physical exercise. A heat sink and a...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00037-x
更新日期:1998-06-01 00:00:00
abstract::On the computational basis of a neurodynamical cortical model, we investigate a specific top-down visual cognitive impairment in brain-damaged patients known as visual spatial neglect. The computational cortical model accounts the neurodynamics underlying selective visual attention, is based on the "biased competition...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2004.06.011
更新日期:2004-11-01 00:00:00
abstract::The potential for a simple, non-invasive measure of respiratory effort based on the pulse oximeter signal - the photoplethysmogram or 'pleth' - was investigated in a pilot study. Several parameters were developed based on a variety of manifestations of respiratory effort in the signal, including modulation changes in ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.12.010
更新日期:2017-03-01 00:00:00
abstract::Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.10.015
更新日期:2014-02-01 00:00:00
abstract::The investigation of patellar tendon reflex involves development of a reflex hammer holder, kinematic data collection and analysis of patellar reflex responses using motion analysis techniques. The main aim of this research is to explore alternative means of assessing reflexes as a part of routine clinical diagnosis. ...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/j.medengphy.2010.11.002
更新日期:2011-05-01 00:00:00
abstract::Recent approaches to the in vitro experimental study of cardiac fluid mechanics involve the use of whole biological structures to investigate in the lab novel therapeutic approaches for the treatment of heart pathologies. To enhance reliability and repeatability, the influence of the actuation strategy of the experime...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.01.007
更新日期:2016-04-01 00:00:00
abstract::Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR effi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.02.005
更新日期:2017-05-01 00:00:00
abstract::Core decompression is the most common procedure for treatment of the early stages of osteonecrosis of the femoral head. The purpose of this study was to compare the biomechanical performance of four different bone graft substitutes combined with core decompression. Subject-specific finite element models generated from...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.05.008
更新日期:2016-09-01 00:00:00
abstract::Successful treatment of tumors with motion-adaptive radiotherapy requires accurate prediction of respiratory motion, ideally with a prediction horizon larger than the latency in radiotherapy system. Accurate prediction of respiratory motion is however a non-trivial task due to the presence of irregularities and intra-...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.04.021
更新日期:2016-08-01 00:00:00