Sensorized pacifier to evaluate non-nutritive sucking in newborns.

Abstract:

:We developed a device for an objective measurement of non-nutritive sucking (NNS). NNS is newborns' spontaneous action that is a predictor of their neural system development and can be adopted as an intervention to train oral feeding skills in preterms. Two miniaturized digital pressure sensors were embedded into a commercial pacifier and the two signals were simultaneously acquired using the Inter-Integrated circuit (I²C) interface. This solution traced a complete pressures profile of the sucking pattern in order to better understand the functional aspects of the two NNS phases, the suction and the expression. Experimental tests with nine newborns confirmed that the sensorized pacifier is an adequate tool for measuring NNS burst-pause patterns. The identified parameters related to the suction/expression rhythmicity could be used as indicators of the NNS ability. This device might be used both for exploring the possible diagnostic data contained in NNS pattern and for monitoring the sucking skills of premature infants.

journal_name

Med Eng Phys

authors

Grassi A,Cecchi F,Sgherri G,Guzzetta A,Gagliardi L,Laschi C

doi

10.1016/j.medengphy.2015.12.013

subject

Has Abstract

pub_date

2016-04-01 00:00:00

pages

398-402

issue

4

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(16)00010-2

journal_volume

38

pub_type

杂志文章
  • Three-dimensional localisation based on projectional and tomographic image correlation: an application for digital tomosynthesis.

    abstract::Accurate three-dimensional tumor localisation in Radiotherapy, is critical to the treatment outcome, particularly when high dose gradients are present. A number of techniques have been proposed for the localisation of anatomical structures or markers. The present study proposes an approach to a concurrent maximisation...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00015-6

    authors: Messaris G,Kolitsi Z,Badea C,Pallikarakis N

    更新日期:1999-03-01 00:00:00

  • Can a 15m-overground wheelchair sprint be used to assess wheelchair-specific anaerobic work capacity?

    abstract:OBJECTIVE:To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint (WAnT). METHODS:Able-bodie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.003

    authors: van der Scheer JW,de Groot S,Vegter RJ,Veeger DH,van der Woude LH

    更新日期:2014-04-01 00:00:00

  • Development of a small wireless device for perspiration monitoring.

    abstract::A small and wireless device that can capture the temporal pattern of perspiration by a novel structure of water vapor collection combined with reusable desiccant has been developed. The novel device consists of a small cylindrical case with a temperature/relative humidity sensor, battery-driven data logger, and silica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.009

    authors: Ogai K,Fukuoka M,Kitamura K,Uchide K,Nemoto T

    更新日期:2016-04-01 00:00:00

  • Loosening detection of the femoral component of hip prostheses with extracorporeal shockwaves: a pilot study.

    abstract::The diagnosis of aseptic loosening of hip implants is often challenging. A vibrational analysis of the bone-implant interface could be an alternative method to analyze the fixation of endoprostheses. We assessed an innovative and new approach for excitation by using extracorporeal shockwaves in this study. In three ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.11.011

    authors: Rieger JS,Jaeger S,Kretzer JP,Rupp R,Bitsch RG

    更新日期:2015-02-01 00:00:00

  • Current development in non-invasive glucose monitoring.

    abstract::Painless control of blood glycemic levels could improve life quality of diabetes patients, enabling a better regulation of hyper- and hypoglycaemia episodes and thereby avoiding physiological complications. Although research groups have been trying for decades to separate non-invasive glucose information from interfer...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2007.06.003

    authors: Ferrante do Amaral CE,Wolf B

    更新日期:2008-06-01 00:00:00

  • A practical technique for measuring human biofluid conductivity using high gain-frequency characteristics.

    abstract::Currently, the study of ion composition and performance in human biofluids plays an important role in biomedical engineering research and technology. This field may become universal for human diagnostics; it allows early detection of different diseases in humans by measuring changes in ion behaviour in human biofluids...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.007

    authors: Al-Nabulsi JI,Aloquili O,Ausheva V,Yuldashev ZM

    更新日期:2011-11-01 00:00:00

  • Partial potentials of selected cardiac muscle regions and heart activity model based on single fibres.

    abstract::We present single fibre heart activity model (SFHAM) based on the current flow through the five bunches of fibres of the cardiac muscle (CM). The five effective fibres are identified and assigned to the appropriate segments of CM. Analytical functions describing ionic flows along the fibres are derived and proposed. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.007

    authors: Janicki JS,Leoński W,Jagielski J

    更新日期:2009-12-01 00:00:00

  • Reconstruction of proximal humeral fractures with a reduced number of screws and a reinforced bone substitute.

    abstract::Multi-fragmented fractures of the proximal humerus are difficult to treat, especially in the case of osteoporotic bone. Intra-operative risks include cartilage damage when inserting multiple screws. A common post-operative complication is distal-varus collapse of the head. The aim of this study was to investigate if a...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.06.002

    authors: Cristofolini L,Morellato K,Cavallo M,Guerra E

    更新日期:2020-08-01 00:00:00

  • Computed tomography (CT)-compatible remote center of motion needle steering robot: Fusing CT images and electromagnetic sensor data.

    abstract::Lung cancer is the most common cause of cancer-related death, and early detection can reduce the mortality rate. Patients with lung nodules greater than 10 mm usually undergo a computed tomography (CT)-guided biopsy. However, aligning the needle with the target is difficult and the needle tends to deflect from a strai...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.04.009

    authors: Shahriari N,Heerink W,van Katwijk T,Hekman E,Oudkerk M,Misra S

    更新日期:2017-07-01 00:00:00

  • Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit-stand transfers and step-up transfers: Comparison with an optoelectronic motion capture system.

    abstract::An inertial measurement unit (IMU) allows kinematic evaluation of human motion with fewer operational constraints than a gold standard optoelectronic motion capture (MOCAP) system. The study's aim was to compare IMU and MOCAP measurements of dynamic pelvic orientation angles during different activities of daily life (...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.11.009

    authors: Bolink SA,Naisas H,Senden R,Essers H,Heyligers IC,Meijer K,Grimm B

    更新日期:2016-03-01 00:00:00

  • A microfluidic device for continuous manipulation of biological cells using dielectrophoresis.

    abstract::The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate no...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.010

    authors: Das D,Biswas K,Das S

    更新日期:2014-06-01 00:00:00

  • Probabilistic analysis of an uncemented total hip replacement.

    abstract::This paper describes the application of probabilistic design methods to the analysis of the behaviour of an uncemented total hip replacement femoral component implanted in a proximal femur. Probabilistic methods allow variations in factors which control the behaviour of the implanted femur (the input parameters) to be...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.01.002

    authors: Dopico-González C,New AM,Browne M

    更新日期:2009-05-01 00:00:00

  • Contrary to basic kinematic modelling, during tight turns, wheelchairs can slide sideways by non-negligible magnitudes: Collision risks may be increased.

    abstract::Small spaces make collision-free turns difficult for wheelchair users. Contrary to basic kinematic wheelchair modelling and not considered previously by engineers; when wheelchairs turn in small spaces, could lateral drift (sideways slipping) increase the risk of collisions with surrounding structures such as walls an...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.11.012

    authors: Abraham BB

    更新日期:2021-01-01 00:00:00

  • Numerical analysis and experimental observation of guidewire motion in a blood vessel model.

    abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.012

    authors: Takashima K,Tsuzuki S,Ooike A,Yoshinaka K,Yu K,Ohta M,Mori K

    更新日期:2014-12-01 00:00:00

  • Optimised analytical models of the dielectric properties of biological tissue.

    abstract::The interaction of electromagnetic fields with the human body is quantified by the dielectric properties of biological tissues. These properties are incorporated into complex numerical simulations using parametric models such as Debye and Cole-Cole, for the computational investigation of electromagnetic wave propagati...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.01.017

    authors: Salahuddin S,Porter E,Krewer F,O' Halloran M

    更新日期:2017-05-01 00:00:00

  • In vitro model of intravenous fluid administration: analysis of vein resistance to rapid fluid delivery.

    abstract::Rapid fluid administration is the cornerstone of successful trauma resuscitation of patients in a state of shock. Intravenous (IV) fluid delivery is a physical intrusion into a vein which results in a complex interaction between the rigid catheter and the compliant vein. We present an experimental model of IV infusion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00046-1

    authors: Yaniv S,Halpern P,Aladgem D,Zaretsky U,Elad D

    更新日期:2000-07-01 00:00:00

  • Quantitative characterisation of impaction events during femoral broaching in total hip arthroplasty.

    abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.12.004

    authors: Preutenborbeck M,Reuter J,Ferrari E

    更新日期:2020-02-01 00:00:00

  • An impedance sensor to monitor and control cerebral ventricular volume.

    abstract::This paper presents a sensor for monitoring and controlling the volume of the cerebrospinal fluid-filled ventricles of the brain. The measurement principle of the sensor exploits electrical conductivity differences between the cerebrospinal fluid and the brain tissue. The electrical contrast was validated using dog br...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.03.011

    authors: Linninger A,Basati S,Dawe R,Penn R

    更新日期:2009-09-01 00:00:00

  • A comparative study on different methods of automatic mesh generation of human femurs.

    abstract::The aim of this study was to evaluate comparatively five methods for automating mesh generation (AMG) when used to mesh a human femur. The five AMG methods considered were: mapped mesh, which provides hexahedral elements through a direct mapping of the element onto the geometry; tetra mesh, which generates tetrahedral...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(97)00049-0

    authors: Viceconti M,Bellingeri L,Cristofolini L,Toni A

    更新日期:1998-01-01 00:00:00

  • Physiological simulation of blood flow in the aorta: comparison of hemodynamic indices as predicted by 3-D FSI, 3-D rigid wall and 1-D models.

    abstract::Interest in patient-specific blood-flow circulation modeling has increased substantially in recent years. The availability of clinical data for geometric and elastic properties together with efficient numerical methods has now made model rendering feasible. This work uses 3-D fluid-structure interaction (FSI) to provi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.009

    authors: Reymond P,Crosetto P,Deparis S,Quarteroni A,Stergiopulos N

    更新日期:2013-06-01 00:00:00

  • Numerical simulation of the flow of aqueous humor in the Schlemm's canal.

    abstract::Schlemm's canal (SC) is a ring structure responsible for maintaining fluid homeostasis in the anterior chamber of the eye by draining aqueous humor (AH) from the trabecular meshwork (TM) into the collecting channel (CC). Obstruction of the AH flow in this conventional pathway leads to an elevation of intraocular press...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.12.005

    authors: Guo JM,Chen ZQ,Chen W,Yan XQ,Zhang H,Wang JM

    更新日期:2021-02-01 00:00:00

  • A four-parameter linear model for analysing cardiorespiratory data in post-operative cardiac patients.

    abstract::This paper investigates the possibility of characterizing the differences between normal- and high-risk postoperative cardiac patients on the basis of four parameters related to a simple linear model of cardiorespiratory performances. The model comprises three subsystems representing cardiac, vascular and respiratory ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/1350-4533(94)90073-6

    authors: Artioli E,Avanzolini G,Barbini P,Gnudi G

    更新日期:1994-11-01 00:00:00

  • Intramedullary femoral nails: one or two lag screws? A preliminary study.

    abstract::Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00081-3

    authors: Wang CJ,Brown CJ,Yettram AL,Procter P

    更新日期:2000-11-01 00:00:00

  • Development and assessment of a Microsoft Kinect based system for imaging the breast in three dimensions.

    abstract::Three-dimensional surface imaging technologies have been used in the planning and evaluation of breast reconstructive and cosmetic surgery. The aim of this study was to develop a 3D surface imaging system based on the Microsoft Kinect and assess the accuracy and repeatability with which the system could image the brea...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.018

    authors: Wheat JS,Choppin S,Goyal A

    更新日期:2014-06-01 00:00:00

  • A method for determining the heat transfer and water vapour permeability of patient support systems.

    abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00003-5

    authors: Nicholson GP,Scales JT,Clark RP,de Calcina-Goff ML

    更新日期:1999-12-01 00:00:00

  • The kinetic model and simulation of blood coagulation--the kinetic influence of activated protein C.

    abstract::The paper described a limited part of the coagulation pathway, and in particular the inhibitory effects of activated protein C in the context of thrombin production. This is a computational modeling study with various assumption made of kinetic rates laws and their summation. The level of complexity and assumed parame...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.01.003

    authors: Qiao YH,Xu CQ,Zeng YJ,Xu XH,Zhao H,Xu H

    更新日期:2004-05-01 00:00:00

  • Monolithic superelastic rods with variable flexural stiffness for spinal fusion: modeling of the processing-properties relationship.

    abstract::The concept of a monolithic Ti-Ni spinal rod with variable flexural stiffness is proposed to reduce the risks associated with spinal fusion. The variable stiffness is conferred to the rod using the Joule-heating local annealing technique. The annealing temperature and the mechanical properties' distributions resulted ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.012

    authors: Facchinello Y,Brailovski V,Petit Y,Mac-Thiong JM

    更新日期:2014-11-01 00:00:00

  • Hemodynamic aspects of the Budd-Chiari syndrome of the liver: A computational model study.

    abstract::Budd-Chiari syndrome (BCS) is a rare liver disease characterised by the obstruction of draining hepatic veins, and subsequent reduced blood return to the heart. Although many clinical BCS studies have been reported, few studies have quantified the associated changes that occur in the entire hepatic circulation. In thi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.04.010

    authors: Ho H,Qiu C

    更新日期:2019-07-01 00:00:00

  • Combining ultrasonic and computed tomography scanning to characterize mechanical properties of cancellous bone in necrotic human femoral heads.

    abstract::Image-based finite element modelling has been commonly used to determine the biomechanical behaviours of human femora, particularly for the diagnosis of femoral head necrosis. One of the fundamental aspects of biomechanical modelling is the relationship between bone density, which is obtained from images, and elastic ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.02.002

    authors: Yue Y,Yang H,Li Y,Zhong H,Tang Q,Wang J,Wang R,He H,Chen W,Chen D

    更新日期:2019-04-01 00:00:00

  • Development and evaluation of a semi-automatic technique for determining the bilateral symmetry plane of the facial skeleton.

    abstract::During reconstructive surgery of the face, one side may be used as a template for the other, exploiting assumed bilateral facial symmetry. The best method to calculate this plane, however, is debated. A new semi-automatic technique for calculating the symmetry plane of the facial skeleton is presented here that uses s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.06.006

    authors: Willing RT,Roumeliotis G,Jenkyn TR,Yazdani A

    更新日期:2013-12-01 00:00:00