Intramedullary femoral nails: one or two lag screws? A preliminary study.

Abstract:

:Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the different types of fracture were investigated. The results show that in order to share the load evenly between two lag screws, a good configuration seems to be to have a slightly larger screw above the lower screw. This also ameliorates stresses in the nail at the lag screw insertion holes. However, using two screws in this way can lead to large stresses in the cancellous bone in the femoral head, and these stresses may be significant in the initiation of cut-out.

journal_name

Med Eng Phys

authors

Wang CJ,Brown CJ,Yettram AL,Procter P

doi

10.1016/s1350-4533(00)00081-3

subject

Has Abstract

pub_date

2000-11-01 00:00:00

pages

613-24

issue

9

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(00)00081-3

journal_volume

22

pub_type

杂志文章
  • Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects.

    abstract::Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and comple...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.015

    authors: Luo D,Rong Q,Chen Q

    更新日期:2017-09-01 00:00:00

  • Liquid ventilation: a mathematical model of gas diffusion in the premature lung.

    abstract::The liquid ventilation (LV) technique was previously demonstrated to be a valuable alternative to ordinary gas ventilation, particularly for newborn patients with severely distressed lungs. This work describes a mathematical model of gas transfer phenomena occurring within the lungs of a preterm newborn baby ventilate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00041-0

    authors: Costantino ML,Fiore GB

    更新日期:1997-03-01 00:00:00

  • Comparison of the bending performance of solid and cannulated spinal pedicle screws using finite element analyses and biomechanical tests.

    abstract::Spinal pedicle screw fixations have been used extensively to treat fracture, tumor, infection, or degeneration of the spine. Cannulated spinal pedicle screws with bone cement augmentation might be a useful method to ameliorate screw loosening. However, cannulated spinal pedicle screws might also increase the risk of s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.06.008

    authors: Shih KS,Hsu CC,Hou SM,Yu SC,Liaw CK

    更新日期:2015-09-01 00:00:00

  • Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    abstract::The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.02.006

    authors: Jiang S,Gan RZ

    更新日期:2018-04-01 00:00:00

  • The effect of compressive deformations on the rate of build-up of oxygen in isolated skeletal muscle cells.

    abstract::In this study we integrated between confocal-based cell-specific finite element (FE) modeling and Virtual Cell (VC) transport simulations in order to determine trends of relationship between externally applied compressive deformations and build-up rates of oxygen in myoblast cells, and to further test how mild culture...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.008

    authors: Leopold E,Sopher R,Gefen A

    更新日期:2011-11-01 00:00:00

  • Measurement of the chondrocyte membrane permeability to Me2SO, glycerol and 1,2-propanediol.

    abstract::The addition of cryopreservative agents (CPAs) to chondrocytes and natural and engineered cartilage is critical to protect the cells and tissues from freezing damage during cryopreservation, but this may cause cell damage, e.g. by osmotic shock. The damage could be minimized by the control of the cell volume excursion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00073-0

    authors: Xu X,Cui Z,Urban JP

    更新日期:2003-09-01 00:00:00

  • Effects of sterilization on the Tekscan digital pressure sensor.

    abstract::Investigations into the effects of sterilization on a new biomechanical pressure sensor are necessary before contemplating in vivo use. Ten, designated Experimental, "K-Scan" digital pressure sensor arrays were sterilized with ethylene oxide gas (EtO), and their ability to accurately and reproducibly measure an applie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00119-x

    authors: Agins HJ,Harder VS,Lautenschlager EP,Kudrna JC

    更新日期:2003-11-01 00:00:00

  • Baseline drift removal and denoising of MCG data using EEMD: role of noise amplitude and the thresholding effect.

    abstract::We adopt the Ensemble Empirical Mode Decomposition (EEMD) method, with an appropriate thresholding on the Intrinsic Mode Functions (IMFs), to denoise the magnetocardiography (MCG) signal. To this end, we discuss the two associated problems that relate to: (i) the amplitude of noise added to the observed signal in the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.023

    authors: Mariyappa N,Sengottuvel S,Parasakthi C,Gireesan K,Janawadkar MP,Radhakrishnan TS,Sundar CS

    更新日期:2014-10-01 00:00:00

  • Modelization of a self-opening peripheral neural interface: a feasibility study.

    abstract::In this paper a self-opening intrafascicular neural interface (SELINE) has been modeled using both a theoretical approach and a Finite Element (FE) analysis. This innovative self opening interface has several potential advantages such as: higher selectivity due to its three-dimensional structure and efficient anchorag...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.001

    authors: Cutrone A,Sergi PN,Bossi S,Micera S

    更新日期:2011-12-01 00:00:00

  • Comparison of algorithms to quantify muscle fatigue in upper limb muscles based on sEMG signals.

    abstract::This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.009

    authors: Kahl L,Hofmann UG

    更新日期:2016-11-01 00:00:00

  • In vivo soft tissue damage assessment for applications in surgery.

    abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.04.002

    authors: Famaey N,Verbeken E,Vinckier S,Willaert B,Herijgers P,Vander Sloten J

    更新日期:2010-06-01 00:00:00

  • Characterization of crackles from patients with fibrosis, heart failure and pneumonia.

    abstract::The spectral analysis of crackles sounds has been carried out based on the assumption that they are stationary signals, and the majority of the work on the crackles was accomplished before the publication of the Computerized Respiratory Sound Analysis (CORSA) guidelines. This works characterizes crackles acquired from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.009

    authors: Ponte DF,Moraes R,Hizume DC,Alencar AM

    更新日期:2013-04-01 00:00:00

  • Reconstruction of dental ultrasonic scaler 3D vibration patterns from phase-related data.

    abstract::Ultrasonic scalers are used in dentistry for removing mineralised plaque, known as calculus, from tooth surfaces. Though there is much information relating to the longitudinal vibrations of scaler probes, corresponding lateral data is limited. Understanding the lateral motion of ultrasonic probes is essential as, when...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.02.010

    authors: Lea SC,Landini G

    更新日期:2010-07-01 00:00:00

  • Ultrasonography and electromyography based hand motion intention recognition for a trans-radial amputee: A case study.

    abstract::Surface electromyography (sEMG) has dominated upper-limb prosthesis control for decades due to its simplicity and effectiveness [1-3]. However, the inherent variability of EMG signal hinders the flexible and accurate control of advanced multi-functional prosthesis. This study is an attempt to use ultrasonography (US) ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.005

    authors: Wang Z,Fang Y,Zhou D,Li K,Cointet C,Liu H

    更新日期:2020-01-01 00:00:00

  • Can a 15m-overground wheelchair sprint be used to assess wheelchair-specific anaerobic work capacity?

    abstract:OBJECTIVE:To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint (WAnT). METHODS:Able-bodie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.003

    authors: van der Scheer JW,de Groot S,Vegter RJ,Veeger DH,van der Woude LH

    更新日期:2014-04-01 00:00:00

  • A predictive study of the mechanical behaviour of coronary stents by computer modelling.

    abstract::Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent expansion is an important factor to define the effectiveness of the surgical procedure: it depends on the stent geometry and includes large displacements and deformat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.08.012

    authors: Migliavacca F,Petrini L,Montanari V,Quagliana I,Auricchio F,Dubini G

    更新日期:2005-01-01 00:00:00

  • Measurement of thermal conductivity of bovine cortical bone.

    abstract::The thermal conductivity of cortical bone was characterized experimentally. Specimens were taken from the mid-diaphysis of bovine femora, and the rate of heat transfer was measured in three orthogonal directions. The conductivity was found to be 0.58+/-0.018 W/mK in the longitudinal direction, 0.53+/-0.030 W/mK in the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00003-0

    authors: Davidson SR,James DF

    更新日期:2000-12-01 00:00:00

  • A model of lung parenchyma stress relaxation using fractional viscoelasticity.

    abstract::Some pulmonary diseases and injuries are believed to correlate with lung viscoelasticity changes. Hence, a better understanding of lung viscoelastic models could provide new perspectives on the progression of lung pathology and trauma. In the presented study, stress relaxation measurements were performed to quantify r...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.05.003

    authors: Dai Z,Peng Y,Mansy HA,Sandler RH,Royston TJ

    更新日期:2015-08-01 00:00:00

  • Stress free configuration of the human eye.

    abstract::Numerical simulations of eye globes often rely on topographies that have been measured in vivo using devices such as the Pentacam or OCT. The topographies, which represent the form of the already stressed eye under the existing intraocular pressure, introduce approximations in the analysis. The accuracy of the simulat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.09.006

    authors: Elsheikh A,Whitford C,Hamarashid R,Kassem W,Joda A,Büchler P

    更新日期:2013-02-01 00:00:00

  • Assessment of the initial viscoelastic properties of a critical segmental long bone defect reconstructed with impaction bone grafting and intramedullary nailing.

    abstract:INTRODUCTION:This study compared the initial viscoelastic properties of a segmental tibial defect stabilized with intramedullary nailing and impaction bone grafting to that of a transverse fracture stabilized with intramedullary nailing. MATERIALS AND METHODS:Seven sheep tibiae were tested in compression (1000N), bend...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.003

    authors: Costi JJ,Stanley RM,Ding B,Solomon LB

    更新日期:2014-01-01 00:00:00

  • Design of a biodegradable plate for femoral shaft fracture fixation.

    abstract::Biodegradable materials have been generating increasing bit of interest in biomedical applications and associated research. The evolution of implants made up of such materials (Mg-alloys, etc.) has the potential to be a game changer in fracture surgeries. These implants are essentially made up of a plate and a number ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.05.010

    authors: Chandra G,Pandey A,Pandey S

    更新日期:2020-07-01 00:00:00

  • A novel ultrasonic aerosol generator.

    abstract::An ultrasonic aerosol generator constructed from a domestic humidifier is described which has been used to produce liquid aerosols for physiological investigations. The instrument was constructed from a Pifco domestic humidifier modified to include an energy guide to direct the oscillations of the transducer through t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)97320-o

    authors: Davies A,Hudson N,Pirie L

    更新日期:1995-07-01 00:00:00

  • In vivo measurements of the elastic mechanical properties of human skin by indentation tests.

    abstract::Knowledge about the human skin mechanical properties is essential in several domains, particularly for dermatology, cosmetic or to detect some cutaneous pathology. This study proposes a new method to determine the human skin mechanical properties in vivo using the indentation test. Usually, the skin mechanical paramet...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.06.011

    authors: Pailler-Mattei C,Bec S,Zahouani H

    更新日期:2008-06-01 00:00:00

  • Three-dimensional analysis and visualization of regional MR signal intensity distribution of articular cartilage.

    abstract::The aim of this study was to develop a technique for analyzing and visualizing the regional, three-dimensional signal intensity distribution of articular cartilage in MR images, as a potential surrogate marker of structural or biochemical alterations in early osteoarthritis. Exemplary MR-images of human patellae were ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00006-1

    authors: Hohe J,Faber S,Muehlbauer R,Reiser M,Englmeier KH,Eckstein F

    更新日期:2002-04-01 00:00:00

  • Effect of the stiffness of bone substitutes on the biomechanical behaviour of femur for core decompression.

    abstract::Core decompression is the most common procedure for treatment of the early stages of osteonecrosis of the femoral head. The purpose of this study was to compare the biomechanical performance of four different bone graft substitutes combined with core decompression. Subject-specific finite element models generated from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.008

    authors: Tran TN,Kowalczyk W,Hohn HP,Jäger M,Landgraeber S

    更新日期:2016-09-01 00:00:00

  • Quantitative characterisation of impaction events during femoral broaching in total hip arthroplasty.

    abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.12.004

    authors: Preutenborbeck M,Reuter J,Ferrari E

    更新日期:2020-02-01 00:00:00

  • Biomechanical design using in-vitro finite element modeling of distal femur fracture plates made from semi-rigid materials versus traditional metals for post-operative toe-touch weight-bearing.

    abstract::This proof-of-concept study designs distal femur fracture plates from semi-rigid materials vs. traditional metals for toe-touch weight-bearing recommended to patients immediately after surgery. The two-fold goal was to (a) reduce stress shielding (SS) by increasing cortical bone stress thereby reducing the risk of bon...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.11.015

    authors: Gee A,Bougherara H,Schemitsch EH,Zdero R

    更新日期:2021-01-01 00:00:00

  • A portable monitoring system for measuring weight-bearing during tibial fracture healing.

    abstract::An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal par...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00061-7

    authors: Aranzulla PJ,Muckle DS,Cunningham JL

    更新日期:1998-10-01 00:00:00

  • A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries.

    abstract::The investigation presented in this paper has attempted to study, from a fluid dynamics point of view, the consequences of the presence of a stent on the flow of blood. The method adopted is mainly by numerical simulation using a finite element technique, but visualization experiments and an analytical study have also...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00072-2

    authors: Natarajan S,Mokhtarzadeh-Dehghan MR

    更新日期:2000-10-01 00:00:00

  • Effects of aqueous humor hydrodynamics on human eye heat transfer under external heat sources.

    abstract::The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-d...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.011

    authors: Tiang KL,Ooi EH