A comparative study on different methods of automatic mesh generation of human femurs.

Abstract:

:The aim of this study was to evaluate comparatively five methods for automating mesh generation (AMG) when used to mesh a human femur. The five AMG methods considered were: mapped mesh, which provides hexahedral elements through a direct mapping of the element onto the geometry; tetra mesh, which generates tetrahedral elements from a solid model of the object geometry; voxel mesh which builds cubic 8-node elements directly from CT images; and hexa mesh that automatically generated hexahedral elements from a surface definition of the femur geometry. The various methods were tested against two reference models: a simplified geometric model and a proximal femur model. The first model was useful to assess the inherent accuracy of the meshes created by the AMG methods, since an analytical solution was available for the elastic problem of the simplified geometric model. The femur model was used to test the AMG methods in a more realistic condition. The femoral geometry was derived from a reference model (the "standardized femur") and the finite element analyses predictions were compared to experimental measurements. All methods were evaluated in terms of human and computer effort needed to carry out the complete analysis, and in terms of accuracy. The comparison demonstrated that each tested method deserves attention and may be the best for specific situations. The mapped AMG method requires a significant human effort but is very accurate and it allows a tight control of the mesh structure. The tetra AMG method requires a solid model of the object to be analysed but is widely available and accurate. The hexa AMG method requires a significant computer effort but can also be used on polygonal models and is very accurate. The voxel AMG method requires a huge number of elements to reach an accuracy comparable to that of the other methods, but it does not require any pre-processing of the CT dataset to extract the geometry and in some cases may be the only viable solution.

journal_name

Med Eng Phys

authors

Viceconti M,Bellingeri L,Cristofolini L,Toni A

doi

10.1016/s1350-4533(97)00049-0

subject

Has Abstract

pub_date

1998-01-01 00:00:00

pages

1-10

issue

1

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(97)00049-0

journal_volume

20

pub_type

杂志文章
  • Detection of cardiac late potentials in nonstationary noise.

    abstract::An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00069-0

    authors: Atarius R,Sörnmo L

    更新日期:1997-04-01 00:00:00

  • Power spectra accuracy improvement by a method for leakage effect reduction.

    abstract::A method for leakage effect reduction by a modification of the classical spectra obtained Discrete Fourier Transform is proposed. The properties of the new method are investigated analytically and validated through synthesized signals, processed by the developed complete computational procedure. This combines the prop...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(97)00006-4

    authors: Mitov IP

    更新日期:1997-07-01 00:00:00

  • Effect of wheelchair mass, tire type and tire pressure on physical strain and wheelchair propulsion technique.

    abstract::The purpose of this study was to evaluate the effect of wheelchair mass, solid vs. pneumatic tires and tire pressure on physical strain and wheelchair propulsion technique. 11 Able-bodied participants performed 14 submaximal exercise blocks on a treadmill with a fixed speed (1.11 m/s) within 3 weeks to determine the e...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2013.03.019

    authors: de Groot S,Vegter RJ,van der Woude LH

    更新日期:2013-10-01 00:00:00

  • Development and validation of a robotic system for ankle joint testing.

    abstract::Ankle sprains are the most common sports injury. Gaining a better understanding of ankle mechanics will help improve current treatments, enabling a better quality of life for patients following surgery. In this paper, the development of a robotic system for ankle joint testing is presented. It is composed of an indust...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.10.002

    authors: El Daou H,Calder JD,Stephen JM

    更新日期:2018-12-01 00:00:00

  • Pre-surgical CT/FEA for craniofacial distraction: I. Methodology, development, and validation of the cranial finite element model.

    abstract::Recently, surgeons have begun to treat serious congenital craniofacial deformities including craniosynostoses with mechanical devices that gradually distract the skull. As a prospective means of treatment planning for such complex deformities, FE models derived from routine preoperative CT scans (CT/FEA) would provide...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00053-8

    authors: Remmler D,Olson L,Ekstrom R,Duke D,Matamoros A,Matthews D,Ullrich CG

    更新日期:1998-11-01 00:00:00

  • A four-parameter linear model for analysing cardiorespiratory data in post-operative cardiac patients.

    abstract::This paper investigates the possibility of characterizing the differences between normal- and high-risk postoperative cardiac patients on the basis of four parameters related to a simple linear model of cardiorespiratory performances. The model comprises three subsystems representing cardiac, vascular and respiratory ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/1350-4533(94)90073-6

    authors: Artioli E,Avanzolini G,Barbini P,Gnudi G

    更新日期:1994-11-01 00:00:00

  • A novel parameter for the prediction of pedicle screw fixation in cancellous bone - A biomechanical study on synthetic foam.

    abstract::Pedicle screw loosening is still observed in clinical practice. Therefore, the understanding of the interaction between screw and bone is evermore subject of research. However, complex relationships between screw design and anchorage are rarely examined. For this reason, it is investigated whether screw fixation is pr...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.03.001

    authors: Weidling M,Oefner C,Schoenfelder S,Heyde CE

    更新日期:2020-05-01 00:00:00

  • Comparison of calibration methods for accelerometers used in human motion analysis.

    abstract::In the fields of medicine and biomechanics, MEMS accelerometers are increasingly used to perform activity recognition by directly measuring acceleration; to calculate speed and position by numerical integration of the signal; or to estimate the orientation of body parts in combination with gyroscopes. For some of thes...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2016.08.004

    authors: Nez A,Fradet L,Laguillaumie P,Monnet T,Lacouture P

    更新日期:2016-11-01 00:00:00

  • Effects of a multi-sensory environment on brain-injured patients: assessment of spectral patterns.

    abstract::Snoezelen(®) multi-sensory (SMS) environment has been commonly applied as a therapeutic strategy to alleviate the symptoms associated to a wide variety of pathologies. Despite most studies have reported a wide range of positive revealed short-term changes associated to SMS intervention, little has been done to systema...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.001

    authors: Poza J,Gómez C,Gutiérrez MT,Mendoza N,Hornero R

    更新日期:2013-03-01 00:00:00

  • A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant.

    abstract::This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired wi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.006

    authors: Pan MC,Zhuang HB,Chen CS,Wu JW,Lee SY

    更新日期:2013-12-01 00:00:00

  • Comparison of Ho:YAG laser and coblation for interface tissue removal in minimally invasive hip refixation procedures.

    abstract::Aseptic loosening is the major failure mode for hip prostheses. Currently, loosened prostheses are revised during open surgery. Because of a high complication rate, this demanding procedure cannot be performed in patients with a poor general health. We are developing an alternative minimally invasive refixation proced...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.07.029

    authors: Kraaij G,Malan DF,van der Heide HJ,Dankelman J,Nelissen RG,Valstar ER

    更新日期:2012-04-01 00:00:00

  • Evaluation of four blood pump geometries: fluorescent particle flow visualisation technique.

    abstract::Artificial blood pumps play an increasingly important role in the treatment of end-stage cardiac failure. The fluid dynamics of blood flow through such devices crucially affects their clinical effectiveness. Specifically, if the flow of blood stagnates or slowly re-circulates thrombus formation can occur and the avoid...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00023-0

    authors: Rose ML,Mackay TG,Wheatley DJ

    更新日期:2000-04-01 00:00:00

  • Numerical simulation of the flow of aqueous humor in the Schlemm's canal.

    abstract::Schlemm's canal (SC) is a ring structure responsible for maintaining fluid homeostasis in the anterior chamber of the eye by draining aqueous humor (AH) from the trabecular meshwork (TM) into the collecting channel (CC). Obstruction of the AH flow in this conventional pathway leads to an elevation of intraocular press...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.12.005

    authors: Guo JM,Chen ZQ,Chen W,Yan XQ,Zhang H,Wang JM

    更新日期:2021-02-01 00:00:00

  • Design of tissue engineering scaffolds based on hyperbolic surfaces: structural numerical evaluation.

    abstract::Tissue engineering represents a new field aiming at developing biological substitutes to restore, maintain, or improve tissue functions. In this approach, scaffolds provide a temporary mechanical and vascular support for tissue regeneration while tissue in-growth is being formed. These scaffolds must be biocompatible,...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.05.006

    authors: Almeida HA,Bártolo PJ

    更新日期:2014-08-01 00:00:00

  • Characterizing atypical patterns of Heart Rate before Paroxysmal Ventricular Tachycardia.

    abstract::Results of a comparative analysis between Heart Rate (HR) patterns occurring before the onset of Paroxysmal Ventricular Tachycardia (PVT) and from healthy subjects are shown. Two study groups were made after electrocardiographic dynamical monitoring (Holter) of volunteers. The first group includes 100h from 27 healthy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.004

    authors: Alvarez E,Jiménez J,Moleiro F,Rodríguez A

    更新日期:2010-12-01 00:00:00

  • Electrochemistry of nanoscale DNA surface films on carbon.

    abstract::A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2006.05.009

    authors: Oliveira-Brett AM,Paquim AM,Diculescu VC,Piedade JA

    更新日期:2006-12-01 00:00:00

  • Model-based physiomarkers of cerebral hemodynamics in patients with mild cognitive impairment.

    abstract::In our previous studies, we have introduced model-based "functional biomarkers" or "physiomarkers" of cerebral hemodynamics that hold promise for improved diagnosis of early-stage Alzheimer's disease (AD). The advocated methodology utilizes subject-specific data-based dynamic nonlinear models of cerebral hemodynamics ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.025

    authors: Marmarelis VZ,Shin DC,Orme ME,Zhang R

    更新日期:2014-05-01 00:00:00

  • Reconstruction of dental ultrasonic scaler 3D vibration patterns from phase-related data.

    abstract::Ultrasonic scalers are used in dentistry for removing mineralised plaque, known as calculus, from tooth surfaces. Though there is much information relating to the longitudinal vibrations of scaler probes, corresponding lateral data is limited. Understanding the lateral motion of ultrasonic probes is essential as, when...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.02.010

    authors: Lea SC,Landini G

    更新日期:2010-07-01 00:00:00

  • Parametric study on the interface pullout strength of the vertebral body replacement cage using FEM-based Taguchi methods.

    abstract::Improper design of vertebral body cages may seriously affect the interface strength and cause the lose of fixation for a vertebral body replacement. This research used a FEM-based Taguchi method to investigate the effects of various factors to find the robust design of the body cage. Three-dimensional finite element m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.07.001

    authors: Hsu WH,Chao CK,Hsu HC,Lin J,Hsu CC

    更新日期:2009-04-01 00:00:00

  • Minimization of the knee shear joint load in leg-extension equipment.

    abstract::We developed an analytical biomechanical model for leg-extension equipment and the associated knee-extension/flexion exercises. The shear component, phi(t), of the tibiofemoral joint load was calculated taking into account all the fundamental elements of the equipment mechanics (resistance pad placement, cam/pulley sy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.12.012

    authors: Biscarini A

    更新日期:2008-10-01 00:00:00

  • Measurement of compliance of infusion device consumable elements using an analytical weighing balance.

    abstract::The value of compliance of disposable elements such as infusion lines and syringes can significantly affect the performance characteristics of infusion devices. In a technique used to determine the compliance of infusion lines, the item under test is placed in a semi sealed water filled enclosure and the volume of flu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.016

    authors: Clarkson DM,Barbosa R

    更新日期:2014-11-01 00:00:00

  • Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects.

    abstract::Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and comple...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.015

    authors: Luo D,Rong Q,Chen Q

    更新日期:2017-09-01 00:00:00

  • Sensitivity analysis of the position of the intervertebral centres of reaction in upright standing--a musculoskeletal model investigation of the lumbar spine.

    abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.003

    authors: Zander T,Dreischarf M,Schmidt H

    更新日期:2016-03-01 00:00:00

  • Effect of different inertial parameter sets on joint moment calculation during stair ascending and descending.

    abstract::The reliability of internal joint moment calculation in gait analysis during daily living activities is fundamental for clinical decisions based on joint function. This calculation, obtained by means of the inverse dynamics, depends on several modelling factors, such as assumptions on the segments and on the relevant ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.12.002

    authors: Fantozzi S,Stagni R,Cappello A,Leardini A

    更新日期:2005-07-01 00:00:00

  • Surgical instrumentation for the in vivo determination of human lumbar spinal segment stiffness and viscoelasticity.

    abstract::The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechan...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.07.002

    authors: Ambrosetti-Giudici S,Pfenniger A,Krenn MH,Piotrowski WP,Ferguson SJ,Burger J

    更新日期:2009-11-01 00:00:00

  • Cardiovascular cavitation.

    abstract::This article reviews the role of cavitation in the therapeutic applications of ultrasound and laser surgery, and the cavitation effects in mechanical heart valves. Whenever laser pulses are used to ablate or disrupt tissue in a liquid environment, cavitation bubbles are produced which interact with the tissue. The int...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2009.03.007

    authors: Brujan EA

    更新日期:2009-09-01 00:00:00

  • Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six different state-of-the-art meshes.

    abstract:BACKGROUND:An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. METHOD...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.022

    authors: Konerding MA,Chantereau P,Delventhal V,Holste JL,Ackermann M

    更新日期:2012-09-01 00:00:00

  • Penetration of an artificial arterial thromboembolism in a live animal using an intravascular therapeutic microrobot system.

    abstract::The biomedical applications of wireless robots are an active area of study. In addition to moving to a target lesion, wireless locomotive robots can deliver a therapeutic drug for a specific disease. Thus, they hold great potential as therapeutic devices in blood vessel diseases, such as thrombi and occlusions, and in...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.01.001

    authors: Jeong S,Choi H,Go G,Lee C,Lim KS,Sim DS,Jeong MH,Ko SY,Park JO,Park S

    更新日期:2016-04-01 00:00:00

  • A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries.

    abstract::The investigation presented in this paper has attempted to study, from a fluid dynamics point of view, the consequences of the presence of a stent on the flow of blood. The method adopted is mainly by numerical simulation using a finite element technique, but visualization experiments and an analytical study have also...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00072-2

    authors: Natarajan S,Mokhtarzadeh-Dehghan MR

    更新日期:2000-10-01 00:00:00

  • Surface-based modeling of muscles: Functional simulation of the shoulder.

    abstract::Musculoskeletal simulations are an essential tool for studying functional implications of pathologies and of potential surgical outcomes, e.g., for the complex shoulder anatomy. Most shoulder models rely on line-segment approximation of muscles with potential limitations. Comprehensive shoulder models based on continu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.04.010

    authors: Péan F,Goksel O

    更新日期:2020-08-01 00:00:00