A novel parameter for the prediction of pedicle screw fixation in cancellous bone - A biomechanical study on synthetic foam.

Abstract:

:Pedicle screw loosening is still observed in clinical practice. Therefore, the understanding of the interaction between screw and bone is evermore subject of research. However, complex relationships between screw design and anchorage are rarely examined. For this reason, it is investigated whether screw fixation is predictable by a parameter that maps the thread. Two types of pedicle screws, 6.5 mm and 7.5 mm in major diameter, respectively, are pulled out from synthetic polyurethane foam. Representative design parameters were evaluated with regard to their influence on the insertion torque and pull-out strength. A correlation between the insertion torque and the degree of compacting of the bone was observed. In addition, the pull-out strength was found to be related to the contact area of the bone-screw interface, the bone volume displaced during screwing, and the displaced diameter. The relationship between insertion torque and pull-out strength was also linear. In addition, a relational equation was derived for the pull-out strength versus the insertion torque with the major diameter as scaling factor. Thus, the pull-out strength from cancellous bone is predictable by a representative design parameter. Furthermore, the derived relation equation opens a new perspective for the evaluation of screw fixation.

journal_name

Med Eng Phys

authors

Weidling M,Oefner C,Schoenfelder S,Heyde CE

doi

10.1016/j.medengphy.2020.03.001

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

44-51

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(20)30036-9

journal_volume

79

pub_type

杂志文章
  • Electrochemistry of nanoscale DNA surface films on carbon.

    abstract::A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2006.05.009

    authors: Oliveira-Brett AM,Paquim AM,Diculescu VC,Piedade JA

    更新日期:2006-12-01 00:00:00

  • Partial potentials of selected cardiac muscle regions and heart activity model based on single fibres.

    abstract::We present single fibre heart activity model (SFHAM) based on the current flow through the five bunches of fibres of the cardiac muscle (CM). The five effective fibres are identified and assigned to the appropriate segments of CM. Analytical functions describing ionic flows along the fibres are derived and proposed. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.007

    authors: Janicki JS,Leoński W,Jagielski J

    更新日期:2009-12-01 00:00:00

  • Shape-memory-alloy-based smart knee spacer for total knee arthroplasty: 3D CAD modelling and a computational study.

    abstract::This study introduced a shape memory alloy (SMA)-based smart knee spacer for total knee arthroplasty (TKA). Subsequently, a 3D CAD model of a smart tibial component of TKA was designed in Solidworks software, and verified using a finite element analysis in ANSYS Workbench. The two major properties of the SMA (NiTi), t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.03.001

    authors: Gautam A,Callejas MA,Acharyya A,Acharyya SG

    更新日期:2018-05-01 00:00:00

  • Number and localization of the implants for the fixed prosthetic reconstructions: on the strain in the anterior maxillary region.

    abstract::Resorption following tooth loss and poor bone quality affect the success of implants in the anterior maxilla. Inappropriate planning can cause implant loss and aesthetics problems that are difficult to resolve. There is a limited literature on the optimum number and location of implants in anterior maxilla for fabrica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.004

    authors: Bölükbaşı N,Yeniyol S

    更新日期:2015-04-01 00:00:00

  • Detection of cardiac late potentials in nonstationary noise.

    abstract::An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00069-0

    authors: Atarius R,Sörnmo L

    更新日期:1997-04-01 00:00:00

  • Sensorized pacifier to evaluate non-nutritive sucking in newborns.

    abstract::We developed a device for an objective measurement of non-nutritive sucking (NNS). NNS is newborns' spontaneous action that is a predictor of their neural system development and can be adopted as an intervention to train oral feeding skills in preterms. Two miniaturized digital pressure sensors were embedded into a co...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.013

    authors: Grassi A,Cecchi F,Sgherri G,Guzzetta A,Gagliardi L,Laschi C

    更新日期:2016-04-01 00:00:00

  • Reconstruction of dental ultrasonic scaler 3D vibration patterns from phase-related data.

    abstract::Ultrasonic scalers are used in dentistry for removing mineralised plaque, known as calculus, from tooth surfaces. Though there is much information relating to the longitudinal vibrations of scaler probes, corresponding lateral data is limited. Understanding the lateral motion of ultrasonic probes is essential as, when...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.02.010

    authors: Lea SC,Landini G

    更新日期:2010-07-01 00:00:00

  • Accurate segmentation of respiration waveforms from infants enabling identification and classification of irregular breathing patterns.

    abstract::Although the precise causes of Sudden Infant Death Syndrome (SIDS) are still unclear there is evidence to suggest that hypoxaemia may be a contributory factor. Transcutaneous oxygen monitors can be used but are unsatisfactory for young babies in the home. As an alternative approach, respiratory patterns can be studied...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90005-1

    authors: Wilks PA,English MJ

    更新日期:1994-01-01 00:00:00

  • Mechanical performance of Anatomic-Functional-Geometry dental treatments: A computational study.

    abstract::In this paper the biomechanical response of a novel dental preparation technique, referred to as the Anatomic-Functional-Geometry treatment (AFG), is investigated through a 3D nonlinear finite-element modelling approach. A comparative investigation against a standard technique employed in dental clinical practice is c...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.10.016

    authors: Gaziano P,Lorenzi C,Bianchi D,Monaldo E,Dolci A,Vairo G

    更新日期:2020-12-01 00:00:00

  • Sonomyography: monitoring morphological changes of forearm muscles in actions with the feasibility for the control of powered prosthesis.

    abstract::Electromyography (EMG) has been widely used for the assessment of musculoskeletal functions and the control of electrical prostheses, which make use of the EMG signal generated by the contraction of the residual muscles. In spite of the successful applications of EMG in different fields, it has some inherent limitatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.07.012

    authors: Zheng YP,Chan MM,Shi J,Chen X,Huang QH

    更新日期:2006-06-01 00:00:00

  • Comparison of different methods for the determination of the true wave propagation coefficient, in rubber tubes and the canine thoracic aorta.

    abstract::The results from studies of wave propagation in large arteries carried out over the last 25 years have shown that there is a good agreement among values of the imaginary part of the complex propagation coefficient, as expressed by pressure or flow-rate wave propagation velocity. However, there is considerable disparit...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00073-2

    authors: Bertram CD,Gow BS,Greenwald SE

    更新日期:1997-04-01 00:00:00

  • A new MR-compatible loading device to study in vivo muscle damage development in rats due to compressive loading.

    abstract::To study the aetiology of pressure ulcers an MR-compatible loading device was developed. Magnetic resonance imaging provides the possibility of non-invasive evaluation of muscle tissue after compressive loading. Pressure was applied to the tibialis anterior region of rats by means of an indenter. The developed MR-comp...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.07.005

    authors: Stekelenburg A,Oomens CW,Strijkers GJ,de Graaf L,Bader DL,Nicolay K

    更新日期:2006-05-01 00:00:00

  • Relationship between architectural parameters and sample volume of human cancellous bone in micro-CT scanning.

    abstract::Truly representative architectural parameters of trabeculea can be extremely difficult to achieve based on scanning images because of variable porosity and distribution of trabeculae within the specific overall scanned volume of bone. Accordingly, in present study different selective volume of interests, measured from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.01.014

    authors: Yan YB,Qi W,Wang J,Liu LF,Teo EC,Tianxia Q,Ba JJ,Lei W

    更新日期:2011-07-01 00:00:00

  • A method for determining the heat transfer and water vapour permeability of patient support systems.

    abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00003-5

    authors: Nicholson GP,Scales JT,Clark RP,de Calcina-Goff ML

    更新日期:1999-12-01 00:00:00

  • Assessment of gait sensitivity norm as a predictor of risk of falling during walking in a neuromusculoskeletal model.

    abstract::Quantifying the risk of falling (falls risk) would be helpful in treating people with gait disorders. The gait sensitivity norm (GSN) is a stability measure that correlates well to risk of falling in passive dynamic walkers but has not been evaluated on humans or human-like walking models. We assessed the correlation ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.018

    authors: Thangal SN,Talaty M,Balasubramanian S

    更新日期:2013-10-01 00:00:00

  • Development and assessment of a Microsoft Kinect based system for imaging the breast in three dimensions.

    abstract::Three-dimensional surface imaging technologies have been used in the planning and evaluation of breast reconstructive and cosmetic surgery. The aim of this study was to develop a 3D surface imaging system based on the Microsoft Kinect and assess the accuracy and repeatability with which the system could image the brea...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.018

    authors: Wheat JS,Choppin S,Goyal A

    更新日期:2014-06-01 00:00:00

  • Automatic detection of EEG artefacts arising from head movements using EEG and gyroscope signals.

    abstract::Contamination of EEG signals by artefacts arising from head movements has been a serious obstacle in the deployment of automatic neurological event detection systems in ambulatory EEG. In this paper, we present work on categorizing these head-movement artefacts as one distinct class and on using support vector machine...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.017

    authors: O'Regan S,Faul S,Marnane W

    更新日期:2013-07-01 00:00:00

  • Porcine carotid arterial material property alterations with induced atheroma: an in vivo study.

    abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.014

    authors: Nagaraj A,Kim H,Hamilton AJ,Mun JH,Smulevitz B,Kane BJ,Yan LL,Roth SI,McPherson DD,Chandran KB

    更新日期:2005-03-01 00:00:00

  • Hemodynamic aspects of the Budd-Chiari syndrome of the liver: A computational model study.

    abstract::Budd-Chiari syndrome (BCS) is a rare liver disease characterised by the obstruction of draining hepatic veins, and subsequent reduced blood return to the heart. Although many clinical BCS studies have been reported, few studies have quantified the associated changes that occur in the entire hepatic circulation. In thi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.04.010

    authors: Ho H,Qiu C

    更新日期:2019-07-01 00:00:00

  • Application of soft tissue modelling to image-guided surgery.

    abstract::The deformation of soft tissue compromises the accuracy of image-guided surgery based on preoperative images, and restricts its applicability to surgery on or near bony structures. One way to overcome these limitations is to combine biomechanical models with sparse intraoperative data, in order to realistically warp t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2005.10.005

    authors: Carter TJ,Sermesant M,Cash DM,Barratt DC,Tanner C,Hawkes DJ

    更新日期:2005-12-01 00:00:00

  • Linear and nonlinear analyses of multi-channel mechanomyographic recordings reveal heterogeneous activation of wrist extensors in presence of delayed onset muscle soreness.

    abstract::In this study, we applied multi-channel mechanomyographic (MMG) recordings in combination with linear and nonlinear analyses to investigate muscular and musculotendinous effects of high intensity eccentric exercise. Twelve accelerometers arranged in a 3 × 4 matrix over the dominant elbow muscles were used to detect MM...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.003

    authors: Madeleine P,Hansen EA,Samani A

    更新日期:2014-12-01 00:00:00

  • Computational fluid dynamic simulations of cavopulmonary connections with an extracardiac lateral conduit.

    abstract::Complex congenital heart defects due to the absence of a ventricular chamber can often be treated by the Fontan surgical procedure. The objective of this work was to quantify the haemodynamics in the Fontan operation (cavopulmonary connection) with extracardiac lateral conduit. Four different models based on the finit...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00042-9

    authors: Migliavacca F,de Leval MR,Dubini G,Pietrabissa R,Fumero R

    更新日期:1999-04-01 00:00:00

  • Pilot study of a surgical robot system for zygomatic implant placement.

    abstract::Zygomatic implant technology has been regarded as an alternative treatment to massive grafting surgery in the severe atrophic maxillary. Nowadays, the assistant method with a real-time surgical navigation has been applied to reduce the risks of zygomatic implant placement. However, the accuracy of the complex operatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.020

    authors: Cao Z,Qin C,Fan S,Yu D,Wu Y,Qin J,Chen X

    更新日期:2020-01-01 00:00:00

  • Physiological simulation of blood flow in the aorta: comparison of hemodynamic indices as predicted by 3-D FSI, 3-D rigid wall and 1-D models.

    abstract::Interest in patient-specific blood-flow circulation modeling has increased substantially in recent years. The availability of clinical data for geometric and elastic properties together with efficient numerical methods has now made model rendering feasible. This work uses 3-D fluid-structure interaction (FSI) to provi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.009

    authors: Reymond P,Crosetto P,Deparis S,Quarteroni A,Stergiopulos N

    更新日期:2013-06-01 00:00:00

  • Computation of the elastic properties of a resin impregnated wire mesh by the means of a homogenisation procedure.

    abstract::The present paper presents a homogenisation technique applied to the problem of calculating equivalent material properties of a resin impregnated wire mesh. Although this type of material can be expected to possess, in general, a four-fold axis of rotational symmetry, it was found that a transversally isotropic model ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00065-5

    authors: Hübsch PF,Middleton J,Knox J

    更新日期:2000-09-01 00:00:00

  • Precision test apparatus for evaluating the heating pattern of radiofrequency ablation devices.

    abstract::Radiofrequency has established itself as a useful technique for managing cardiac arrhythmias and treating soft tissue tumors. However, despite its pervasive use, many of the biophysical principals needed to fully understand and optimize the radiofrequency ablation technique have not been explored. We have designed a t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00044-9

    authors: Chang I,Beard B

    更新日期:2002-11-01 00:00:00

  • On-line analysis of middle latency auditory evoked potentials (MLAEP) for monitoring depth of anaesthesia in laboratory rats.

    abstract::In laboratory animals as well as in human beings a depth of anaesthesia, where the subject has no pain or recall of events from the surgery, should be provided. Haemodynamic parameters such as heart rate and blood pressure are not a guarantee for an optimal depth of anaesthesia, especially when using neuromuscular blo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00089-7

    authors: Jensen EW,Nygaard M,Henneberg SW

    更新日期:1998-12-01 00:00:00

  • A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries.

    abstract::The investigation presented in this paper has attempted to study, from a fluid dynamics point of view, the consequences of the presence of a stent on the flow of blood. The method adopted is mainly by numerical simulation using a finite element technique, but visualization experiments and an analytical study have also...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00072-2

    authors: Natarajan S,Mokhtarzadeh-Dehghan MR

    更新日期:2000-10-01 00:00:00

  • Identification of lower arm motions using the EMG signals of shoulder muscles.

    abstract::This investigation explored pattern recognition of EMG signals produced by shoulder area muscles to identify the performance of a select number of lower arm motions. The signals were modelled as fourth-order autoregressive processes with the parameters of the models used to classify the different motions. The recorded...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90024-8

    authors: Latwesen A,Patterson PE

    更新日期:1994-03-01 00:00:00

  • Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems.

    abstract::Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Ti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.011

    authors: Jauch SY,Coles LG,Ng LV,Miles AW,Gill HS

    更新日期:2014-09-01 00:00:00