Porcine carotid arterial material property alterations with induced atheroma: an in vivo study.

Abstract:

OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudation and high cholesterol diet. The images at base line and 8 weeks after denudation were obtained using intravascular ultrasound (IVUS) imaging along with hemodynamic data. Finite element analysis (FEA) along with optimization was employed to assess regional alterations in elastic modulus in the presence of atheroma confirmed by histology. RESULTS:In animals with 8 weeks of induced atherosclerosis, the elastic modulus increased-(elastic modulus-all values x 10(4) Pa, mean+/-S.D.) normal elements (9.34+/-0.36) compared to abnormal elements (9.52+/-0.36) (p<0.05 versus normal elements). Wall thickness increased with atheroma formation. These data demonstrate stiffening vascular wall elastic modulus with lesion progression. This is different from the behavior of femoral arteries, where the elastic modulus decreases with early stages of atheroma development followed by an increase as lesions progress. CONCLUSIONS:This methodology permits determination of areas with early atheroma development, follow atheroma progression, and potentially evaluate interventions aimed at decreasing atheroma load and normalizing vascular material properties.

journal_name

Med Eng Phys

authors

Nagaraj A,Kim H,Hamilton AJ,Mun JH,Smulevitz B,Kane BJ,Yan LL,Roth SI,McPherson DD,Chandran KB

doi

10.1016/j.medengphy.2004.09.014

subject

Has Abstract

pub_date

2005-03-01 00:00:00

pages

147-56

issue

2

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(04)00177-8

journal_volume

27

pub_type

杂志文章
  • Can a 15m-overground wheelchair sprint be used to assess wheelchair-specific anaerobic work capacity?

    abstract:OBJECTIVE:To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint (WAnT). METHODS:Able-bodie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.003

    authors: van der Scheer JW,de Groot S,Vegter RJ,Veeger DH,van der Woude LH

    更新日期:2014-04-01 00:00:00

  • Minimal haemodynamic system model including ventricular interaction and valve dynamics.

    abstract::Characterising circulatory dysfunction and choosing a suitable treatment is often difficult and time consuming, and can result in a deterioration in patient condition, or unsuitable therapy choices. A stable minimal model of the human cardiovascular system (CVS) is developed with the ultimate specific aim of assisting...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2003.10.001

    authors: Smith BW,Chase JG,Nokes RI,Shaw GM,Wake G

    更新日期:2004-03-01 00:00:00

  • Accurate segmentation of respiration waveforms from infants enabling identification and classification of irregular breathing patterns.

    abstract::Although the precise causes of Sudden Infant Death Syndrome (SIDS) are still unclear there is evidence to suggest that hypoxaemia may be a contributory factor. Transcutaneous oxygen monitors can be used but are unsatisfactory for young babies in the home. As an alternative approach, respiratory patterns can be studied...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90005-1

    authors: Wilks PA,English MJ

    更新日期:1994-01-01 00:00:00

  • Mechanical behaviour of DNA molecules--elasticity and migration.

    abstract::A novel multi-scale simulation method developed to describe mesoscale phenomena occurring in biofluidic devices is presented. The approach combines the macro-scale modelling of the carrier fluid and the micro-scale description of the transported macromolecules or compounds. Application of the approach is demonstrated ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.003

    authors: Benke M,Shapiro E,Drikakis D

    更新日期:2011-09-01 00:00:00

  • Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    abstract::The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.02.006

    authors: Jiang S,Gan RZ

    更新日期:2018-04-01 00:00:00

  • Finite element analysis of side branch access during bifurcation stenting.

    abstract::Stent implantation has become a widely accepted endovascular intervention for the treatment of stenosed arteries. This minimally invasive technique has shown excellent results in unbranched arteries. However, stenting bifurcation lesions remains a challenge in coronary intervention as it is associated with a lower suc...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.11.013

    authors: Mortier P,De Beule M,Van Loo D,Verhegghe B,Verdonck P

    更新日期:2009-05-01 00:00:00

  • Loosening detection of the femoral component of hip prostheses with extracorporeal shockwaves: a pilot study.

    abstract::The diagnosis of aseptic loosening of hip implants is often challenging. A vibrational analysis of the bone-implant interface could be an alternative method to analyze the fixation of endoprostheses. We assessed an innovative and new approach for excitation by using extracorporeal shockwaves in this study. In three ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.11.011

    authors: Rieger JS,Jaeger S,Kretzer JP,Rupp R,Bitsch RG

    更新日期:2015-02-01 00:00:00

  • Effects of aqueous humor hydrodynamics on human eye heat transfer under external heat sources.

    abstract::The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-d...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.011

    authors: Tiang KL,Ooi EH

    更新日期:2016-08-01 00:00:00

  • New product development processes within the UK medical device industry.

    abstract::This paper reports on the findings of an extensive survey investigating practising design engineers' perceptions of new product development within the UK medical device industry. The design activity recorded was predominantly the small-scale development of low volume products. Explicit formal procedures were rarely us...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00021-5

    authors: Glen JM,Lord M

    更新日期:1996-12-01 00:00:00

  • In vivo estimation of normal left ventricular stiffness and contractility based on routine cine MR acquisition.

    abstract::Post-myocardial infarction remodeling process is known to alter the mechanical properties of the heart. Biomechanical parameters, such as tissue stiffness and contractility, would be useful for clinicians to better assess the severity of the diseased heart. However, these parameters are difficult to obtain in the curr...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.09.003

    authors: Rumindo GK,Ohayon J,Croisille P,Clarysse P

    更新日期:2020-11-01 00:00:00

  • A new method for long-term home monitoring of fetal movement by pregnant women themselves.

    abstract::Fetal movement is one index of fetal well-being. We designed and built a new recorder based on fetal movement acceleration measurement (FMAM). The FMAM recorder has a newly developed, capacitive acceleration sensor that can detect the oscillations of the maternal abdominal wall caused by fetal movements. In this study...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.001

    authors: Ryo E,Nishihara K,Matsumoto S,Kamata H

    更新日期:2012-06-01 00:00:00

  • Mechanical testing and modelling of the Universal 2 implant.

    abstract::Understanding the load mechanics of orthopaedic implants is important to be able to predict their behaviour in-vivo. Much research, both mechanical and clinical, has been carried out on hip and knee implants, but less has been written about the mechanics of wrist implants. In this paper, the load mechanics of the Univ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.008

    authors: Gislason MK,Foster E,Main D,Fusiek G,Niewczas P,Bransby-Zachary M,Nash DH

    更新日期:2016-06-01 00:00:00

  • Extended Central Tendency Measure and difference plot for heart rate variability analysis.

    abstract::Heart rate variability (HRV) is a non-invasive alternative to analyze the role of the autonomic nervous system (ANS) on heart functioning. Many tools have been developed to analyze collected cardiac data. Among them, the Central Tendency Measure (CTM) is a quantitative method for variability analysis of RR intervals. ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.024

    authors: Belfort RAU,Treccossi SPC,Silva JLF,Pillat VG,Freitas CBN,Dos Santos L

    更新日期:2019-12-01 00:00:00

  • A method for assessment and processing of biomedical signals containing trend and periodic components.

    abstract::A method for assessment and second-order polynomial detrending of signals containing periodic components is proposed. The analytically derived properties of this method are validated with synthesized signals, processed by the computational procedure developed. It is shown that, in addition to accurate detrending, the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00077-0

    authors: Mitov IP

    更新日期:1998-11-01 00:00:00

  • Surface-based modeling of muscles: Functional simulation of the shoulder.

    abstract::Musculoskeletal simulations are an essential tool for studying functional implications of pathologies and of potential surgical outcomes, e.g., for the complex shoulder anatomy. Most shoulder models rely on line-segment approximation of muscles with potential limitations. Comprehensive shoulder models based on continu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.04.010

    authors: Péan F,Goksel O

    更新日期:2020-08-01 00:00:00

  • Modelization of a self-opening peripheral neural interface: a feasibility study.

    abstract::In this paper a self-opening intrafascicular neural interface (SELINE) has been modeled using both a theoretical approach and a Finite Element (FE) analysis. This innovative self opening interface has several potential advantages such as: higher selectivity due to its three-dimensional structure and efficient anchorag...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.001

    authors: Cutrone A,Sergi PN,Bossi S,Micera S

    更新日期:2011-12-01 00:00:00

  • Validated computational framework for efficient systematic evaluation of osteoporotic fracture fixation in the proximal humerus.

    abstract::The high rate of fixation failure in osteoporotic proximal humerus fractures indicate the need for improved solutions. Computer simulations may help to overcome the limitations of the gold standard biomechanical testing in evaluating the performance of new implants and enhance the effectivity and outcome of the design...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.04.011

    authors: Varga P,Inzana JA,Gueorguiev B,Südkamp NP,Windolf M

    更新日期:2018-07-01 00:00:00

  • Computational analysis on the mechanical interaction between a thrombus and red blood cells: possible causes of membrane damage of red blood cells at microvessels.

    abstract::Previous studies investigating thrombus formation have not focused on the physical interaction between red blood cells (RBCs) and thrombus, although they have been speculated that some pathological conditions such as microangiopathic hemolytic anemia (MAHA) stem from interactions between RBCs and thrombi. In this stud...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.01.003

    authors: Kamada H,Imai Y,Nakamura M,Ishikawa T,Yamaguchi T

    更新日期:2012-12-01 00:00:00

  • Clinical relevance of augmented statistical shape model of the scapula in the glenoid region.

    abstract:OBJECTIVE:To illustrate (a) whether a statistical shape model (SSM) augmented with anatomical landmark set(s) performs better fitting and provides improved clinical relevance over non-augmented SSM and (b) which anatomical landmark set provides the best augmentation strategy for predicting the glenoid region of the sca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.007

    authors: Salhi A,Burdin V,Brochard S,Mutsvangwa TE,Borotikar B

    更新日期:2020-02-01 00:00:00

  • Intramedullary femoral nails: one or two lag screws? A preliminary study.

    abstract::Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00081-3

    authors: Wang CJ,Brown CJ,Yettram AL,Procter P

    更新日期:2000-11-01 00:00:00

  • Femur finite element model instantiation from partial anatomies using statistical shape and appearance models.

    abstract::Accurate models of bone shapes are essential for orthopaedic reconstructions. The commonly used methods of using the contralateral side requires an intact bone and anatomical symmetry. Recent studies have shown that statistical shape and appearance models (SSAMs) as an alternative can predict accurate geometric models...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.03.007

    authors: Nolte D,Bull AMJ

    更新日期:2019-05-01 00:00:00

  • Recurrence quantification analysis as a tool for nonlinear exploration of nonstationary cardiac signals.

    abstract::The complexity, nonlinearity and nonstationarity of the cardiovascular system typically defy comprehensive and deterministic mathematical modeling, except from a statistical perspective. Living systems are governed by numerous, continuously changing, interacting variables in the presence of noise. Cardiovascular signa...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00112-6

    authors: Zbilut JP,Thomasson N,Webber CL

    更新日期:2002-01-01 00:00:00

  • Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite.

    abstract::In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the poten...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.09.009

    authors: Biddiss E,Chau T

    更新日期:2006-07-01 00:00:00

  • Model-based physiomarkers of cerebral hemodynamics in patients with mild cognitive impairment.

    abstract::In our previous studies, we have introduced model-based "functional biomarkers" or "physiomarkers" of cerebral hemodynamics that hold promise for improved diagnosis of early-stage Alzheimer's disease (AD). The advocated methodology utilizes subject-specific data-based dynamic nonlinear models of cerebral hemodynamics ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.025

    authors: Marmarelis VZ,Shin DC,Orme ME,Zhang R

    更新日期:2014-05-01 00:00:00

  • Predicting fracture using 2D finite element modelling.

    abstract::A decrease in bone density at the hip or spine has been shown to increase the risk of fracture. A limitation of the bone mineral density (BMD) measurement is that it provides only a measure of a bone sample's average density when projected onto a 2D surface. Effectively, what determines bone fracture is whether an app...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.08.008

    authors: MacNeil JA,Adachi JD,Goltzman D,Josse RG,Kovacs CS,Prior JC,Olszynski W,Davison KS,Kaiser SM,CaMos Research Group.

    更新日期:2012-05-01 00:00:00

  • LES of non-Newtonian physiological blood flow in a model of arterial stenosis.

    abstract::Large Eddy Simulation (LES) is performed to study the physiological pulsatile transition-to-turbulent non-Newtonian blood flow through a 3D model of arterial stenosis by using five different blood viscosity models: (i) Power-law, (ii) Carreau, (iii) Quemada, (iv) Cross and (v) modified-Casson. The computational domain...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.013

    authors: Molla MM,Paul MC

    更新日期:2012-10-01 00:00:00

  • Application of time-varying analysis to diagnostic needle electromyography.

    abstract::Quantification in clinical, diagnostic electromyography (EMG) currently includes motor unit action potential (MUAP) analysis and interference pattern analysis. Early efforts to examine the frequency/power spectra of the interference pattern showed modest value but the technique was not developed further. This paper re...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.07.017

    authors: Sheean GL

    更新日期:2012-03-01 00:00:00

  • Assessment of body composition in adolescent subjects with anorexia nervosa by bioimpedance.

    abstract::Our main goal was to test various impedance methods for measuring body composition in adolescents with anorexia nervosa (AN) during refeeding therapy. A specific objective was to compare the information provided by a foot-to-foot impedancemeter (FFI) with that supplied by a medical multifrequency impedancemeter and by...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.09.005

    authors: Moreno MV,Djeddi DD,Jaffrin MY

    更新日期:2008-07-01 00:00:00

  • Pre-surgical CT/FEA for craniofacial distraction: I. Methodology, development, and validation of the cranial finite element model.

    abstract::Recently, surgeons have begun to treat serious congenital craniofacial deformities including craniosynostoses with mechanical devices that gradually distract the skull. As a prospective means of treatment planning for such complex deformities, FE models derived from routine preoperative CT scans (CT/FEA) would provide...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00053-8

    authors: Remmler D,Olson L,Ekstrom R,Duke D,Matamoros A,Matthews D,Ullrich CG

    更新日期:1998-11-01 00:00:00

  • Pulse transit time in paediatric respiratory sleep studies.

    abstract::Pulse transit time (PTT) has emerged over the recent decades as a simple and non-invasive measure to quantify inspiratory effort changes in adults with sleep disordered breathing (SDB). Hence, this shows promise to be an effective screening tool for the paediatrics. However, little is known about its utility and suita...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2006.01.006

    authors: Foo JY

    更新日期:2007-01-01 00:00:00