Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite.

Abstract:

:In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the potential of a selection of electroactive polymers for sensory applications in hand prostheses. Candidate electroactive polymers are reviewed in terms of their relevant advantages and disadvantages, together with their current implementation in related applications. Empirical analysis of one of the most novel electroactive polymers, ionic polymer metal composites (IPMC), was conducted to demonstrate its potential for prosthetic applications. With linear responses within the operating range typical of hand prostheses, bending angles, and bending rates were accurately measured with 4.4+/-2.5 and 4.8+/-3.5% error, respectively, using the IPMC sensors. With these comparable error rates to traditional resistive bend sensors and a wide range of sensitivities and responses, electroactive polymers offer a promising alternative to more traditional sensory approaches. Their potential role in prosthetics is further heightened by their flexible and formable structure, and their ability to act as both sensors and actuators.

journal_name

Med Eng Phys

authors

Biddiss E,Chau T

doi

10.1016/j.medengphy.2005.09.009

subject

Has Abstract

pub_date

2006-07-01 00:00:00

pages

568-78

issue

6

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(05)00212-2

journal_volume

28

pub_type

杂志文章
  • Validation of a C2-C7 cervical spine finite element model using specimen-specific flexibility data.

    abstract::This study presents a specimen-specific C2-C7 cervical spine finite element model that was developed using multiblock meshing techniques. The model was validated using in-house experimental flexibility data obtained from the cadaveric specimen used for mesh development. The C2-C7 specimen was subjected to pure continu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.03.001

    authors: Kallemeyn N,Gandhi A,Kode S,Shivanna K,Smucker J,Grosland N

    更新日期:2010-06-01 00:00:00

  • A novel ultrasonic aerosol generator.

    abstract::An ultrasonic aerosol generator constructed from a domestic humidifier is described which has been used to produce liquid aerosols for physiological investigations. The instrument was constructed from a Pifco domestic humidifier modified to include an energy guide to direct the oscillations of the transducer through t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)97320-o

    authors: Davies A,Hudson N,Pirie L

    更新日期:1995-07-01 00:00:00

  • Measurement of compliance of infusion device consumable elements using an analytical weighing balance.

    abstract::The value of compliance of disposable elements such as infusion lines and syringes can significantly affect the performance characteristics of infusion devices. In a technique used to determine the compliance of infusion lines, the item under test is placed in a semi sealed water filled enclosure and the volume of flu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.016

    authors: Clarkson DM,Barbosa R

    更新日期:2014-11-01 00:00:00

  • Classification of waist-acceleration signals in a continuous walking record.

    abstract::We attempted to distinguish walking on level ground from walking on a stairway using waist acceleration signals. A triaxial accelerometer was fixed to the subject's waist and the three acceleration signals were recorded by a portable data logger at a sampling rate of 256 Hz. Twenty healthy male subjects were asked to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00041-2

    authors: Sekine M,Tamura T,Togawa T,Fukui Y

    更新日期:2000-05-01 00:00:00

  • Measurement of ejection fraction with standard thermodilution catheters.

    abstract::Right ventricle ejection fraction (RVEF) is clinically used to evaluate right ventricular function. The thermodilution method can be modified to estimate the RVEF. However, this method requires a thermistor with a fast time response in order to yield correct estimates. Digital signal processing techniques that were de...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00026-7

    authors: dos Santos I,Ferreira da Rocha A,Assis de O Nascimento F,Souza Neto J,Valvano JW

    更新日期:2002-06-01 00:00:00

  • Design and testing of a high-speed treadmill to measure ground reaction forces at the limit of human gait.

    abstract::Investigations focused on the gait and physiological limits of human speed have been on-going for more than a century. However, due to measurement limitation a kinetic understanding of the foot-ground collision and how these dynamics differ between individuals to confer speed and limit gait has only recently begun to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.04.009

    authors: Bundle MW,Powell MO,Ryan LJ

    更新日期:2015-09-01 00:00:00

  • Motion quality evaluation of upper limb target-reaching movements.

    abstract::Fitts' Law was extended in the polar coordinate system, and a set of indices for human motion evaluation is proposed. In this paper, the index of difficulty and the index of performance are introduced as the general indices for the quality measure of plane target-to-target movement. As an example, the target-reaching ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00121-7

    authors: Yang N,Zhang M,Huang C,Jin D

    更新日期:2002-03-01 00:00:00

  • Motion analysis in delirium: a discrete approach in determining physical activity for the purpose of delirium motoric subtyping.

    abstract::The purpose of this study was to determine the use and feasibility of accelerometry-based monitoring and to examine a discrete multi-resolution signal analysis technique to determine motoric subtypes in patients with DSM-IV delirium. Forty consecutive patients receiving palliative care (23 male, 17 female, mean age+/-...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2009.10.012

    authors: Godfrey A,Conway R,Leonard M,Meagher D,Olaighin GM

    更新日期:2010-03-01 00:00:00

  • Acoustic power measurement of high-intensity focused ultrasound transducer using a pressure sensor.

    abstract::The acoustic power of high-intensity focused ultrasound (HIFU) is an important parameter that should be measured prior to each treatment to guarantee effective and safe outcomes. A new calibration technique was developed that involves estimating the pressure distribution, calculating the acoustic power using an underw...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.01.014

    authors: Zhou Y

    更新日期:2015-03-01 00:00:00

  • Pulse transit time in paediatric respiratory sleep studies.

    abstract::Pulse transit time (PTT) has emerged over the recent decades as a simple and non-invasive measure to quantify inspiratory effort changes in adults with sleep disordered breathing (SDB). Hence, this shows promise to be an effective screening tool for the paediatrics. However, little is known about its utility and suita...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2006.01.006

    authors: Foo JY

    更新日期:2007-01-01 00:00:00

  • Functional evaluation of natural sensory feedback incorporated in a hand grasp neuroprosthesis.

    abstract::We investigated whether automatic control of a hand grasp neuroprosthesis by means of signals from natural sensors in the skin of the index finger can mimic the natural control of grasp force in an important task of daily living, namely eating. We designed a simulated eating task with the same ratio of rest and activi...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.03.002

    authors: Inmann A,Haugland M

    更新日期:2004-07-01 00:00:00

  • A numerical investigation into the influence of the properties of cobalt chrome cellular structures on the load transfer to the periprosthetic femur following total hip arthroplasty.

    abstract::Stress shielding of the periprosthetic femur following total hip arthroplasty is a problem that can promote the premature loosening of femoral stems. In order to reduce the need for revision surgery it is thought that more flexible implant designs need to be considered. In this work, the mechanical properties of laser...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.008

    authors: Hazlehurst KB,Wang CJ,Stanford M

    更新日期:2014-04-01 00:00:00

  • Smartphone application for emergency signal detection.

    abstract::Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). Th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.002

    authors: Figueiredo IN,Leal C,Pinto L,Bolito J,Lemos A

    更新日期:2016-09-01 00:00:00

  • Exploiting parameter sparsity in model-based reconstruction to accelerate proton density and T(2) mapping.

    abstract::T2 mapping is a powerful noninvasive technique providing quantitative biological information of the inherent tissue properties. However, its clinical usage is limited due to the relative long scanning time. This paper proposed a novel model-based method to address this problem. Typically, we directly estimated the rel...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.002

    authors: Peng X,Liu X,Zheng H,Liang D

    更新日期:2014-11-01 00:00:00

  • Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects.

    abstract::Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and comple...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.015

    authors: Luo D,Rong Q,Chen Q

    更新日期:2017-09-01 00:00:00

  • Monolithic superelastic rods with variable flexural stiffness for spinal fusion: modeling of the processing-properties relationship.

    abstract::The concept of a monolithic Ti-Ni spinal rod with variable flexural stiffness is proposed to reduce the risks associated with spinal fusion. The variable stiffness is conferred to the rod using the Joule-heating local annealing technique. The annealing temperature and the mechanical properties' distributions resulted ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.012

    authors: Facchinello Y,Brailovski V,Petit Y,Mac-Thiong JM

    更新日期:2014-11-01 00:00:00

  • Review on aspects of artificial tactile feedback in laparoscopic surgery.

    abstract::Since direct manual tissue palpation is not possible in laparoscopic surgery, feedback information on tactile tissue properties is considerably diminished. Restoring part of the surgeon's sense of touch through devices capable of providing artificial tactile feedback (ATF) is an active field of applied research and de...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2009.06.003

    authors: Schostek S,Schurr MO,Buess GF

    更新日期:2009-10-01 00:00:00

  • Automated analysis of MR image of hip: geometrical evaluation of the Legg-Calve-Perthes disease.

    abstract::This study proposes semi-automatic determination of geometrical features in hip magnetic resonance (MR) images in order to evaluate the Legg-Calvé-Perthes disease (LCPD). Nine anatomical points on a hip image are selected by a clinician; then eight geometrical indexes of the hip joint are calculated: acetabulum head i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.10.003

    authors: Pouletaut P,Claude I,Winzenrieth R,Ho Ba Tho MC,Sebag G

    更新日期:2005-06-01 00:00:00

  • Precise and fast calculation of the motor unit potentials detected by a point and rectangular plate electrode.

    abstract::To reduce the time of computation of a motor unit potential (MUP), the shape of intracellular action potential (IAP) and (or) MU anatomy are generally simplified. A method of MUP presentation is suggested. It provides accuracy of the MUPs calculated for any distance and size of rectangular electrodes together with con...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00014-9

    authors: Dimitrov GV,Dimitrova NA

    更新日期:1998-07-01 00:00:00

  • Improving the detection of evoked responses to periodic stimulation by using bivariate local spectral F-test - Application to EEG during photic stimulation.

    abstract::The spectral local F-test has been applied for detecting evoked responses to rhythmic stimulation that are embedded in the ongoing electroencephalogram (EEG). Based on the sampling distribution of a flat spectrum at the neighbourhood of the stimulation frequency, spectral peaks in an EEG signal that are due to the sti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.032

    authors: Felix LB,Rocha PF,Mendes EMAM,Miranda de Sá AMFL

    更新日期:2017-10-01 00:00:00

  • Comparison of isotropic and orthotropic material property assignments on femoral finite element models under two loading conditions.

    abstract::CT data has been widely used in the finite element modeling of bone. It can provide useful information on the geometrical topology and material properties of bone. Based on CT data, the assignment of bone material properties to finite element meshes is a fundamental step in the model generation. Most work done in this...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.06.003

    authors: Peng L,Bai J,Zeng X,Zhou Y

    更新日期:2006-04-01 00:00:00

  • A model of lung parenchyma stress relaxation using fractional viscoelasticity.

    abstract::Some pulmonary diseases and injuries are believed to correlate with lung viscoelasticity changes. Hence, a better understanding of lung viscoelastic models could provide new perspectives on the progression of lung pathology and trauma. In the presented study, stress relaxation measurements were performed to quantify r...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.05.003

    authors: Dai Z,Peng Y,Mansy HA,Sandler RH,Royston TJ

    更新日期:2015-08-01 00:00:00

  • Development and testing of acoustically-matched hydrogel-based electrodes for simultaneous EMG-ultrasound detection.

    abstract::In this manuscript we describe the development and testing of a bipolar electrode for the simultaneous acquisition of ultrasound (US) images and surface electromyograms (EMGs) from the same muscle region. The developed electrode (bEMG-US) consists of two circular sensing regions (20 mm diameter) with fixed inter-elect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.12.002

    authors: Botter A,Beltrandi M,Cerone GL,Gazzoni M,Vieira TMM

    更新日期:2019-02-01 00:00:00

  • A new method for long-term home monitoring of fetal movement by pregnant women themselves.

    abstract::Fetal movement is one index of fetal well-being. We designed and built a new recorder based on fetal movement acceleration measurement (FMAM). The FMAM recorder has a newly developed, capacitive acceleration sensor that can detect the oscillations of the maternal abdominal wall caused by fetal movements. In this study...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.001

    authors: Ryo E,Nishihara K,Matsumoto S,Kamata H

    更新日期:2012-06-01 00:00:00

  • Real time monitoring of muscular fatigue from dynamic surface myoelectric signals using a complex covariance approach.

    abstract::A method aimed at the real-time monitoring of muscular fatigue was implemented and optimized. The method is based on an estimate of the complex covariance function in order to evaluate, in real time, the mean frequency of the myoelectric signal spectrum. Real-time implementation is guaranteed by a recursive computatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00049-1

    authors: Conforto S,D'Alessio T

    更新日期:1999-05-01 00:00:00

  • Computed tomography (CT)-compatible remote center of motion needle steering robot: Fusing CT images and electromagnetic sensor data.

    abstract::Lung cancer is the most common cause of cancer-related death, and early detection can reduce the mortality rate. Patients with lung nodules greater than 10 mm usually undergo a computed tomography (CT)-guided biopsy. However, aligning the needle with the target is difficult and the needle tends to deflect from a strai...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.04.009

    authors: Shahriari N,Heerink W,van Katwijk T,Hekman E,Oudkerk M,Misra S

    更新日期:2017-07-01 00:00:00

  • Application of higher order statistics/spectra in biomedical signals--a review.

    abstract::For many decades correlation and power spectrum have been primary tools for digital signal processing applications in the biomedical area. The information contained in the power spectrum is essentially that of the autocorrelation sequence; which is sufficient for complete statistical descriptions of Gaussian signals o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2010.04.009

    authors: Chua KC,Chandran V,Acharya UR,Lim CM

    更新日期:2010-09-01 00:00:00

  • Modelization of a self-opening peripheral neural interface: a feasibility study.

    abstract::In this paper a self-opening intrafascicular neural interface (SELINE) has been modeled using both a theoretical approach and a Finite Element (FE) analysis. This innovative self opening interface has several potential advantages such as: higher selectivity due to its three-dimensional structure and efficient anchorag...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.06.001

    authors: Cutrone A,Sergi PN,Bossi S,Micera S

    更新日期:2011-12-01 00:00:00

  • Fuzzy clustering of gait patterns of patients after ankle arthrodesis based on kinematic parameters.

    abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00020-0

    authors: Su F,Wu W,Cheng Y,Chou Y

    更新日期:2001-03-01 00:00:00

  • Magnetic resonance-based thermometry during laser ablation on ex-vivo swine pancreas and liver.

    abstract::Laser Ablation (LA) is a minimally-invasive procedure for tumor treatment. LA outcomes depend on the heat distribution inside tissues and require accurate temperature measurement during the procedure. Magnetic resonance imaging (MRI) allows a non-invasive and three-dimensional thermometry of the organ undergoing LA. I...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.04.001

    authors: Allegretti G,Saccomandi P,Giurazza F,Caponero MA,Frauenfelder G,Di Matteo FM,Beomonte Zobel B,Silvestri S,Schena E

    更新日期:2015-07-01 00:00:00