Motion analysis in delirium: a discrete approach in determining physical activity for the purpose of delirium motoric subtyping.

Abstract:

:The purpose of this study was to determine the use and feasibility of accelerometry-based monitoring and to examine a discrete multi-resolution signal analysis technique to determine motoric subtypes in patients with DSM-IV delirium. Forty consecutive patients receiving palliative care (23 male, 17 female, mean age+/-standard deviation 68.4+/-11.9 years) were assessed using 24-h accelerometer-based monitoring. The total amount of time spent per activity of sitting/lying, standing and stepping were calculated. This was achieved through the multilevel decomposition and reconstruction of the accelerometer signals by means of the discrete wavelet transform. Both the reconstructed approximations and details of the discrete transform were used for motoric subtyping. This was compared to a validated activity monitor for validation purposes. Demographic and clinical data per patient were also collected. Of the 40 patients selected for accelerometry, complete 24-h readings were available for 34 patients and analyses were confined to this group. Of the 34 patients included, 25 met criteria for DSM-IV delirium while 9 were non-delirious comparison subjects with equivalent medical diagnoses receiving treatment in the same setting. It was concluded that accelerometry-based measurement of a delirious cohort within a palliative setting is both a reliable and feasible method of continuous monitoring. Of the activities performed by the patients, periods of standing proved to be the most discriminatory in determining between each subtype.

journal_name

Med Eng Phys

authors

Godfrey A,Conway R,Leonard M,Meagher D,Olaighin GM

doi

10.1016/j.medengphy.2009.10.012

subject

Has Abstract

pub_date

2010-03-01 00:00:00

pages

101-10

issue

2

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(09)00228-8

journal_volume

32

pub_type

临床试验,杂志文章
  • Study on gastric interdigestive pressure activity based on phase space reconstruction and FastICA algorithm.

    abstract::To investigate the features of the gastric interdigestive pressure activity under normal physiological conditions, we have developed the wireless radiotelemetry capsule based on a telemetry technique. Twelve healthy volunteers participated in this study. Pressure activity data which are an important index of gastric m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.04.017

    authors: Huang B,Yan G,Zan P,Li Q

    更新日期:2009-04-01 00:00:00

  • Study of human-machine physical interface for wearable mobility assist devices.

    abstract::A decrease in mobility, related to illness, trauma or ageing, negatively affects the quality of life of the rapidly growing elderly population. A promising solution to maintain this standard of living is powered wearable mobility assist devices. Although they have achieved technological breakthroughs in the last decad...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.03.008

    authors: Levesque L,Doumit M

    更新日期:2020-06-01 00:00:00

  • Monolithic superelastic rods with variable flexural stiffness for spinal fusion: modeling of the processing-properties relationship.

    abstract::The concept of a monolithic Ti-Ni spinal rod with variable flexural stiffness is proposed to reduce the risks associated with spinal fusion. The variable stiffness is conferred to the rod using the Joule-heating local annealing technique. The annealing temperature and the mechanical properties' distributions resulted ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.012

    authors: Facchinello Y,Brailovski V,Petit Y,Mac-Thiong JM

    更新日期:2014-11-01 00:00:00

  • Exploiting parameter sparsity in model-based reconstruction to accelerate proton density and T(2) mapping.

    abstract::T2 mapping is a powerful noninvasive technique providing quantitative biological information of the inherent tissue properties. However, its clinical usage is limited due to the relative long scanning time. This paper proposed a novel model-based method to address this problem. Typically, we directly estimated the rel...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.002

    authors: Peng X,Liu X,Zheng H,Liang D

    更新日期:2014-11-01 00:00:00

  • Development and testing of acoustically-matched hydrogel-based electrodes for simultaneous EMG-ultrasound detection.

    abstract::In this manuscript we describe the development and testing of a bipolar electrode for the simultaneous acquisition of ultrasound (US) images and surface electromyograms (EMGs) from the same muscle region. The developed electrode (bEMG-US) consists of two circular sensing regions (20 mm diameter) with fixed inter-elect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.12.002

    authors: Botter A,Beltrandi M,Cerone GL,Gazzoni M,Vieira TMM

    更新日期:2019-02-01 00:00:00

  • Assessment of four statistical pattern recognition techniques to assist in obstructive sleep apnoea diagnosis from nocturnal oximetry.

    abstract::The aim of this study is to assess the utility of traditional statistical pattern recognition techniques to help in obstructive sleep apnoea (OSA) diagnosis. Classifiers based on quadratic (QDA) and linear (LDA) discriminant analysis, K-nearest neighbours (KNN) and logistic regression (LR) were evaluated. Spectral and...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.05.010

    authors: Marcos JV,Hornero R,Alvarez D,del Campo F,Zamarrón C

    更新日期:2009-10-01 00:00:00

  • Intramedullary femoral nails: one or two lag screws? A preliminary study.

    abstract::Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00081-3

    authors: Wang CJ,Brown CJ,Yettram AL,Procter P

    更新日期:2000-11-01 00:00:00

  • Apparatus and methods for studying artificial feedback-control of the plantarflexors in paraplegics without interference from the brain.

    abstract::Apparatus has been built to explore the practical feasibility of using automatic control with electrical stimulation of paralysed legs to restore function. The experiments are performed with paraplegics with the aim of achieving a realistic postural task: to see whether the body may be maintained upright by stimulatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(97)00020-9

    authors: Donaldson Nde N,Munih M,Phillips GF,Perkins TA

    更新日期:1997-09-01 00:00:00

  • A fast responding combined direct and indirect calorimeter for human subjects.

    abstract::The construction and performance of a 5.4 m3 combined direct and indirect calorimeter for human subjects is described. The calorimeter was constructed for studies on human subjects primarily undergoing fast alterations in heat production and heat losses, e.g. after a meal or during physical exercise. A heat sink and a...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00037-x

    authors: Faber P,Lammert O,Johansen O,Garby L

    更新日期:1998-06-01 00:00:00

  • The Windkessel model revisited: a qualitative analysis of the circulatory system.

    abstract::In this paper, we derive a comprehensive computational model to estimate the arterial pressure and the cardiac output of humans, by refining and adapting the well-established equations of the Windkessel theory. The model inputs are based on patient specific factors such as age, sex, smoking and fitness habits as well ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.11.010

    authors: Tsanas A,Goulermas JY,Vartela V,Tsiapras D,Theodorakis G,Fisher AC,Sfirakis P

    更新日期:2009-06-01 00:00:00

  • Stimulated production of vowel-like LX-waveforms and spectral damping in the absence of phonation.

    abstract::Electrical impedance 'LX' waveforms measured across the neck at the thyroid level during phonation are known to be correlated with vocal fold movement. Changes in vocal fold contact are thought to be the cause of this phenomenon though emerging applications in radiotherapy indicate that changes in the configuration of...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00065-6

    authors: Moore C,Jones S

    更新日期:2002-09-01 00:00:00

  • A novel ultrasonic aerosol generator.

    abstract::An ultrasonic aerosol generator constructed from a domestic humidifier is described which has been used to produce liquid aerosols for physiological investigations. The instrument was constructed from a Pifco domestic humidifier modified to include an energy guide to direct the oscillations of the transducer through t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)97320-o

    authors: Davies A,Hudson N,Pirie L

    更新日期:1995-07-01 00:00:00

  • An in silico study of the influence of vessel wall deformation on neointimal hyperplasia progression in peripheral bypass grafts.

    abstract::Neointimal hyperplasia (NIH) is a major obstacle to graft patency in the peripheral arteries. A complex interaction of biomechanical factors contribute to NIH development and progression, and although haemodynamic markers such as wall shear stress have been linked to the disease, these have so far been insufficient to...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.011

    authors: Donadoni F,Bonfanti M,Pichardo-Almarza C,Homer-Vanniasinkam S,Dardik A,Díaz-Zuccarini V

    更新日期:2019-12-01 00:00:00

  • Development and validation of an improved mechanical thorax for simulating cardiopulmonary resuscitation with adjustable chest stiffness and simulated blood flow.

    abstract::Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR effi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.02.005

    authors: Eichhorn S,Spindler J,Polski M,Mendoza A,Schreiber U,Heller M,Deutsch MA,Braun C,Lange R,Krane M

    更新日期:2017-05-01 00:00:00

  • Effects of laminectomy and facetectomy on the stability of the lumbar motion segment.

    abstract::A ligamentous, nonlinear, sliding contact, three-dimensional finite element (FE) model of L2-L3 complex was developed to investigate the biomechanical effect of laminectomy with and without facetectomy. The L2-L3 FE model was validated against experimental study under various physiological loadings and found to match ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2003.11.006

    authors: Lee KK,Teo EC

    更新日期:2004-04-01 00:00:00

  • In vitro assessment of mitral valve function in cyclically pressurized porcine hearts.

    abstract::Recent approaches to the in vitro experimental study of cardiac fluid mechanics involve the use of whole biological structures to investigate in the lab novel therapeutic approaches for the treatment of heart pathologies. To enhance reliability and repeatability, the influence of the actuation strategy of the experime...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.01.007

    authors: Vismara R,Leopaldi AM,Piola M,Asselta C,Lemma M,Antona C,Redaelli A,van de Vosse F,Rutten M,Fiore GB

    更新日期:2016-04-01 00:00:00

  • A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries.

    abstract::The investigation presented in this paper has attempted to study, from a fluid dynamics point of view, the consequences of the presence of a stent on the flow of blood. The method adopted is mainly by numerical simulation using a finite element technique, but visualization experiments and an analytical study have also...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00072-2

    authors: Natarajan S,Mokhtarzadeh-Dehghan MR

    更新日期:2000-10-01 00:00:00

  • Toward verified and validated FE simulations of a femur with a cemented hip prosthesis.

    abstract:BACKGROUND:Verified and validated CT-based high-order finite element (FE) methods were developed that predict accurately the mechanical response of patient-specific intact femurs. Here we extend these capabilities to human femurs undergoing a total hip replacement using cemented prostheses. METHODS:A fresh-frozen huma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.09.007

    authors: Yosibash Z,Katz A,Milgrom C

    更新日期:2013-07-01 00:00:00

  • Diffusion coefficients of articular cartilage for different CT and MRI contrast agents.

    abstract::In contrast enhanced magnetic resonance imaging (MRI) and computed tomography (CT), the equilibrium distribution of anionic contrast agent is expected to reflect the fixed charged density (FCD) of articular cartilage. Diffusion is mainly responsible for the transport of contrast agents into cartilage. In osteoarthriti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.06.002

    authors: Kulmala KA,Korhonen RK,Julkunen P,Jurvelin JS,Quinn TM,Kröger H,Töyräs J

    更新日期:2010-10-01 00:00:00

  • Number and localization of the implants for the fixed prosthetic reconstructions: on the strain in the anterior maxillary region.

    abstract::Resorption following tooth loss and poor bone quality affect the success of implants in the anterior maxilla. Inappropriate planning can cause implant loss and aesthetics problems that are difficult to resolve. There is a limited literature on the optimum number and location of implants in anterior maxilla for fabrica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.004

    authors: Bölükbaşı N,Yeniyol S

    更新日期:2015-04-01 00:00:00

  • Robot assisted treadmill training: mechanisms and training strategies.

    abstract::The rehabilitation engineering community is working towards the development of robotic devices that can assist during gait training of patients suffering from neurologic injuries such as stroke and spinal cord injuries (SCI). The field of robot assisted treadmill training has rapidly evolved during the last decade. Th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2010.12.010

    authors: Hussain S,Xie SQ,Liu G

    更新日期:2011-06-01 00:00:00

  • Cytoskeleton and plasma-membrane damage resulting from exposure to sustained deformations: A review of the mechanobiology of chronic wounds.

    abstract::The purpose of this review paper is to summarize the current knowledge on cell-scale mechanically-inflicted deformation-damage, which is at the frontier of cell mechanobiology and biomechanics science, specifically in the context of chronic wounds. The dynamics of the mechanostructure of cells and particularly, the da...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2016.05.014

    authors: Gefen A,Weihs D

    更新日期:2016-09-01 00:00:00

  • Human body model response to mechanical impulse.

    abstract::Despite our understanding of the importance of falling, previous studies have ignored the effects of falls from standing height. In this article, lumped parameter linear and nonlinear models of a standing human have been used to simulate the impact response of the body segments due to inputs at the shoes. The accelera...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00081-1

    authors: Jarrah M,Qassem W,Othman M,Gdeisat M

    更新日期:1997-06-01 00:00:00

  • Electrocardiogram beat detection enhancement using independent component analysis.

    abstract::Beat detection is a basic and fundamental step in electrocardiogram (ECG) processing. In many ECG applications strong artifacts from biological or technical sources could appear and cause distortion of ECG signals. Beat detection algorithm desired property is to avoid these distortions and detect beats in any situatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.07.017

    authors: Kuzilek J,Lhotska L

    更新日期:2013-06-01 00:00:00

  • Identification of lower arm motions using the EMG signals of shoulder muscles.

    abstract::This investigation explored pattern recognition of EMG signals produced by shoulder area muscles to identify the performance of a select number of lower arm motions. The signals were modelled as fourth-order autoregressive processes with the parameters of the models used to classify the different motions. The recorded...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90024-8

    authors: Latwesen A,Patterson PE

    更新日期:1994-03-01 00:00:00

  • Detection of cardiac late potentials in nonstationary noise.

    abstract::An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00069-0

    authors: Atarius R,Sörnmo L

    更新日期:1997-04-01 00:00:00

  • A new MR-compatible loading device to study in vivo muscle damage development in rats due to compressive loading.

    abstract::To study the aetiology of pressure ulcers an MR-compatible loading device was developed. Magnetic resonance imaging provides the possibility of non-invasive evaluation of muscle tissue after compressive loading. Pressure was applied to the tibialis anterior region of rats by means of an indenter. The developed MR-comp...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.07.005

    authors: Stekelenburg A,Oomens CW,Strijkers GJ,de Graaf L,Bader DL,Nicolay K

    更新日期:2006-05-01 00:00:00

  • Assessment of body composition in adolescent subjects with anorexia nervosa by bioimpedance.

    abstract::Our main goal was to test various impedance methods for measuring body composition in adolescents with anorexia nervosa (AN) during refeeding therapy. A specific objective was to compare the information provided by a foot-to-foot impedancemeter (FFI) with that supplied by a medical multifrequency impedancemeter and by...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.09.005

    authors: Moreno MV,Djeddi DD,Jaffrin MY

    更新日期:2008-07-01 00:00:00

  • Effect of wheelchair mass, tire type and tire pressure on physical strain and wheelchair propulsion technique.

    abstract::The purpose of this study was to evaluate the effect of wheelchair mass, solid vs. pneumatic tires and tire pressure on physical strain and wheelchair propulsion technique. 11 Able-bodied participants performed 14 submaximal exercise blocks on a treadmill with a fixed speed (1.11 m/s) within 3 weeks to determine the e...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2013.03.019

    authors: de Groot S,Vegter RJ,van der Woude LH

    更新日期:2013-10-01 00:00:00

  • An external portable device for adaptive deep brain stimulation (aDBS) clinical research in advanced Parkinson's Disease.

    abstract::Compared to conventional deep brain stimulation (DBS) for patients with Parkinson's Disease (PD), the newer approach of adaptive DBS (aDBS), regulating stimulation on the basis of the patient's clinical state, promises to achieve better clinical outcomes, avoid adverse-effects and save time for tuning parameters. A re...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.007

    authors: Arlotti M,Rossi L,Rosa M,Marceglia S,Priori A

    更新日期:2016-05-01 00:00:00