Human body model response to mechanical impulse.

Abstract:

:Despite our understanding of the importance of falling, previous studies have ignored the effects of falls from standing height. In this article, lumped parameter linear and nonlinear models of a standing human have been used to simulate the impact response of the body segments due to inputs at the shoes. The acceleration transfer and frequency response were determined. The effect of nonlinear damping was simulated. Nonlinear effects were found to be most significant when the input amplitude increases. Frequency response attenuation was significant, resulting in almost a shift in the magnitude plots in the range (0.1-100 Hz) of frequency. When the input amplitude was reduced, the nonlinear effects became apparent only in the medium frequency range. In the case simulating a human subject exposed to impulse at the foot, a large amount of energy is dissipated in the joints due to the friction resulting in a joint disorder. This is most significant at the medium frequency range that is expected to be induced by a running human subject.

journal_name

Med Eng Phys

authors

Jarrah M,Qassem W,Othman M,Gdeisat M

doi

10.1016/s1350-4533(96)00081-1

subject

Has Abstract

pub_date

1997-06-01 00:00:00

pages

308-16

issue

4

eissn

1350-4533

issn

1873-4030

pii

S1350453396000811

journal_volume

19

pub_type

杂志文章
  • Validation of a finite element model of a unilateral external fixator in a rabbit tibia defect model.

    abstract::In case of large segmental defects in load-bearing bones, an external fixator is used to provide mechanical stability to the defect site. The overall stiffness of the bone-fixator system is determined not only by the fixator design but also by the way the fixator is mounted to the bone. This stiffness is an important ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.006

    authors: Karunratanakul K,Kerckhofs G,Lammens J,Vanlauwe J,Schrooten J,Van Oosterwyck H

    更新日期:2013-07-01 00:00:00

  • Segmentation of magnetic resonance images using a combination of neural networks and active contour models.

    abstract::Segmentation of medical images is very important for clinical research and diagnosis, leading to a requirement for robust automatic methods. This paper reports on the combined use of a neural network (a multilayer perceptron, MLP) and active contour model ('snake') to segment structures in magnetic resonance (MR) imag...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s1350-4533(03)00137-1

    authors: Middleton I,Damper RI

    更新日期:2004-01-01 00:00:00

  • Analysis of the effects of surface stiffness on the contact interaction between a finger and a cylindrical handle using a three-dimensional hybrid model.

    abstract::Contact interactions between the hand and handle, such as the contact surface softness and contact surface curvature, will affect both physical effort and musculoskeletal fatigue, thereby the comfort and safety of power tool operations. Previous models of hand gripping can be categorized into two groups: multi-body dy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.03.007

    authors: Wu JZ,Dong RG,Warren CM,Welcome DE,McDowell TW

    更新日期:2014-07-01 00:00:00

  • Porcine carotid arterial material property alterations with induced atheroma: an in vivo study.

    abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.014

    authors: Nagaraj A,Kim H,Hamilton AJ,Mun JH,Smulevitz B,Kane BJ,Yan LL,Roth SI,McPherson DD,Chandran KB

    更新日期:2005-03-01 00:00:00

  • Physiological simulation of blood flow in the aorta: comparison of hemodynamic indices as predicted by 3-D FSI, 3-D rigid wall and 1-D models.

    abstract::Interest in patient-specific blood-flow circulation modeling has increased substantially in recent years. The availability of clinical data for geometric and elastic properties together with efficient numerical methods has now made model rendering feasible. This work uses 3-D fluid-structure interaction (FSI) to provi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.009

    authors: Reymond P,Crosetto P,Deparis S,Quarteroni A,Stergiopulos N

    更新日期:2013-06-01 00:00:00

  • How measurement artifacts affect cerebral autoregulation outcomes: A technical note on transfer function analysis.

    abstract::Cerebral autoregulation (CA) is the mechanism that aims to maintain adequate cerebral perfusion during changes in blood pressure (BP). Transfer function analysis (TFA), the most reported method in literature to quantify CA, shows large between-study variability in outcomes. The aim of this study is to investigate the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.001

    authors: Meel-van den Abeelen AS,de Jong DL,Lagro J,Panerai RB,Claassen JA

    更新日期:2016-05-01 00:00:00

  • Multispectral characterization of tissues encountered during laparoscopic colorectal surgery.

    abstract:AIMS:This study investigated the feasibility of automated differentiation between essential tissue types encountered during laparoscopic colorectal surgery using spectral analysis. METHODS:Wide band (440-1830 nm) spectra were collected using an optical fiber probe and spectrometer from freshly explanted, ex vivo, huma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.01.004

    authors: Schols RM,Dunias P,Wieringa FP,Stassen LP

    更新日期:2013-07-01 00:00:00

  • Localization error analysis for stereo X-ray image guidance with probability method.

    abstract::The mean value and standard deviation of localization error for the stereo imaging systems are derived based on probability theory. Compared with the maximum error analysis method used in our previous study, the new approach yields more informative and precise results as the guidance for X-ray imaging system design an...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00084-4

    authors: Jiang H,Chen WR,Wang G,Liu H

    更新日期:2001-10-01 00:00:00

  • Non-invasive measurement of hepatic oxygenation by an oxygen electrode in human orthotopic liver transplantation.

    abstract::Precise evaluation of graft reperfusion is difficult in clinical liver transplantation. The oxygen electrode (OE) is a novel technique to detect blood flow indirectly by measuring the quantity of oxygen which can diffuse from the hepatic tissue to the surface electrode. Application of the surface OE does not influence...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00060-6

    authors: Seifalian AM,Mallett S,Piasecki C,Rolles K,Davidson BR

    更新日期:2000-06-01 00:00:00

  • A 16-channel SQUID-device for biomagnetic investigations of small objects.

    abstract::Biomagnetic investigations in basic physiological research using animals require measurement devices different from commercial biomagnetometers used in human investigations. Two major problems have to be tackled in the design of such biomagnetometers. First, the spatial sampling needs to be much higher. Second, the di...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00088-0

    authors: Nowak H,Giessler F,Huonker R,Haueisen J,Röther J,Eiselt M

    更新日期:1999-10-01 00:00:00

  • Determination of the position and orientation of artificial knee implants using markers embedded in a bone: preliminary in vitro experiments.

    abstract::This study describes the method of determination of the position and orientation of artificial knee implants using a single-plane radiograph. To simplify the 3D/2D matching problem, we proposed to use small markers embedded in a bone. From the image coordinates of markers, it is possible to estimate the position and o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00037-7

    authors: Imai S,Higashijima K,Ishida A,Fukuoka Y,Hoshino A,Minamitani H

    更新日期:2003-06-01 00:00:00

  • Comparison of calibration methods for accelerometers used in human motion analysis.

    abstract::In the fields of medicine and biomechanics, MEMS accelerometers are increasingly used to perform activity recognition by directly measuring acceleration; to calculate speed and position by numerical integration of the signal; or to estimate the orientation of body parts in combination with gyroscopes. For some of thes...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2016.08.004

    authors: Nez A,Fradet L,Laguillaumie P,Monnet T,Lacouture P

    更新日期:2016-11-01 00:00:00

  • Partial potentials of selected cardiac muscle regions and heart activity model based on single fibres.

    abstract::We present single fibre heart activity model (SFHAM) based on the current flow through the five bunches of fibres of the cardiac muscle (CM). The five effective fibres are identified and assigned to the appropriate segments of CM. Analytical functions describing ionic flows along the fibres are derived and proposed. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.007

    authors: Janicki JS,Leoński W,Jagielski J

    更新日期:2009-12-01 00:00:00

  • Suitability of commercial barometric pressure sensors to distinguish sitting and standing activities for wearable monitoring.

    abstract::Despite its medical relevance, accurate recognition of sedentary (sitting and lying) and dynamic activities (e.g. standing and walking) remains challenging using a single wearable device. Currently, trunk-worn wearable systems can differentiate sitting from standing with moderate success, as activity classifiers often...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.001

    authors: Massé F,Bourke AK,Chardonnens J,Paraschiv-Ionescu A,Aminian K

    更新日期:2014-06-01 00:00:00

  • Pulse pressure waveform estimation using distension profiling with contactless optical probe.

    abstract::The pulse pressure waveform has, for long, been known as a fundamental biomedical signal and its analysis is recognized as a non-invasive, simple, and resourceful technique for the assessment of arterial vessels condition observed in several diseases. In the current paper, waveforms from non-invasive optical probe tha...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.014

    authors: Pereira T,Santos I,Oliveira T,Vaz P,Pereira T,Santos H,Pereira H,Correia C,Cardoso J

    更新日期:2014-11-01 00:00:00

  • Characterizing the reduction of stimulation artifact noise in a tripolar nerve cuff electrode by application of a conductive shield layer.

    abstract::Tripolar nerve cuff electrodes have been widely used for measuring peripheral nerve activity. However, despite the high signal-to-noise ratio levels that can be achieved with this recording configuration, the clinical use of cuff electrodes in closed-loop controlled neuroprostheses remains limited. This is largely att...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.11.010

    authors: Sabetian P,Sadeghlo B,Zhang CH,Yoo PB

    更新日期:2017-02-01 00:00:00

  • A nonparametric feature for neonatal EEG seizure detection based on a representation of pseudo-periodicity.

    abstract::Automated methods of neonatal EEG seizure detection attempt to highlight the evolving, stereotypical, pseudo-periodic, nature of EEG seizure while rejecting the nonstationary, modulated, coloured stochastic background in the presence of various EEG artefacts. An important aspect of neonatal seizure detection is, there...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.08.001

    authors: Stevenson NJ,O'Toole JM,Rankine LJ,Boylan GB,Boashash B

    更新日期:2012-05-01 00:00:00

  • The effects of flute shape and thread profile on the insertion torque and primary stability of dental implants.

    abstract::Easy insertion of the implant and stable bone purchase is essential for an ideal dental implantation. At the implant tip, the cutting flutes and conical profile are respectively designed to reduce insertion resistance and facilitate the initial insertion. However, the tapered tip might reduce the self-tapping and bone...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.021

    authors: Wu SW,Lee CC,Fu PY,Lin SC

    更新日期:2012-09-01 00:00:00

  • TETRA mobile radios interfere with electroencephalography recording equipment.

    abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.009

    authors: Fouquet NC,Hawken MB,Elliott P,Burgess AP

    更新日期:2013-11-01 00:00:00

  • Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit-stand transfers and step-up transfers: Comparison with an optoelectronic motion capture system.

    abstract::An inertial measurement unit (IMU) allows kinematic evaluation of human motion with fewer operational constraints than a gold standard optoelectronic motion capture (MOCAP) system. The study's aim was to compare IMU and MOCAP measurements of dynamic pelvic orientation angles during different activities of daily life (...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.11.009

    authors: Bolink SA,Naisas H,Senden R,Essers H,Heyligers IC,Meijer K,Grimm B

    更新日期:2016-03-01 00:00:00

  • Cardiovascular cavitation.

    abstract::This article reviews the role of cavitation in the therapeutic applications of ultrasound and laser surgery, and the cavitation effects in mechanical heart valves. Whenever laser pulses are used to ablate or disrupt tissue in a liquid environment, cavitation bubbles are produced which interact with the tissue. The int...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2009.03.007

    authors: Brujan EA

    更新日期:2009-09-01 00:00:00

  • New product development processes within the UK medical device industry.

    abstract::This paper reports on the findings of an extensive survey investigating practising design engineers' perceptions of new product development within the UK medical device industry. The design activity recorded was predominantly the small-scale development of low volume products. Explicit formal procedures were rarely us...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00021-5

    authors: Glen JM,Lord M

    更新日期:1996-12-01 00:00:00

  • Motion quality evaluation of upper limb target-reaching movements.

    abstract::Fitts' Law was extended in the polar coordinate system, and a set of indices for human motion evaluation is proposed. In this paper, the index of difficulty and the index of performance are introduced as the general indices for the quality measure of plane target-to-target movement. As an example, the target-reaching ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00121-7

    authors: Yang N,Zhang M,Huang C,Jin D

    更新日期:2002-03-01 00:00:00

  • Quantification of holographic fringe data: comparison of intact and implanted femurs.

    abstract::The strains developed on the surface of a femur with and without an implanted femoral hip replacement were investigated using holographic interferometry (HI). Interferometric fringe data from the four aspects of the loaded femur were quantified and the resulting curvature calculated. Curvature was related to the strai...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00003-4

    authors: Katz DM,Blatcher S,Shelton JC

    更新日期:1998-03-01 00:00:00

  • The kinetic model and simulation of blood coagulation--the kinetic influence of activated protein C.

    abstract::The paper described a limited part of the coagulation pathway, and in particular the inhibitory effects of activated protein C in the context of thrombin production. This is a computational modeling study with various assumption made of kinetic rates laws and their summation. The level of complexity and assumed parame...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.01.003

    authors: Qiao YH,Xu CQ,Zeng YJ,Xu XH,Zhao H,Xu H

    更新日期:2004-05-01 00:00:00

  • Suspension microarrays for the identification of the response patterns in hyperinflammatory diseases.

    abstract::Miniaturized and parallelized sandwich immunoassays allow the simultaneous analysis of a variety of parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. To study inflammatory diseases, protein arrays can be used to an...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.01.003

    authors: Hsu HY,Wittemann S,Schneider EM,Weiss M,Joos TO

    更新日期:2008-10-01 00:00:00

  • A pin-array method for capturing tissue deformation under defined pressure distributions and its application to prosthetic socket design.

    abstract::The Fit4Purpose project aims to develop upper limb prosthetic devices which are suitable for deployment in lower- and middle-income countries (LMIC's). Open-frame trans-radial socket designs are being considered, formed of several, linked components, including pads which interface directly with the skin surface. A mec...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.08.003

    authors: Prince M,Kenney LP,Howard D

    更新日期:2020-10-01 00:00:00

  • Compressive and tensile properties of articular cartilage in axial loading are modulated differently by osmotic environment.

    abstract::Aims of the present study were to test the hypotheses that (1) the compressive properties of articular cartilage are affected more by changes in the medium ionic concentration than the tensile properties, (2) collagen network controls the compression-tension nonlinearity of articular cartilage, and (3) proteoglycan (P...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.11.004

    authors: Korhonen RK,Jurvelin JS

    更新日期:2010-03-01 00:00:00

  • In vivo measurements of the elastic mechanical properties of human skin by indentation tests.

    abstract::Knowledge about the human skin mechanical properties is essential in several domains, particularly for dermatology, cosmetic or to detect some cutaneous pathology. This study proposes a new method to determine the human skin mechanical properties in vivo using the indentation test. Usually, the skin mechanical paramet...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.06.011

    authors: Pailler-Mattei C,Bec S,Zahouani H

    更新日期:2008-06-01 00:00:00

  • A model of lung parenchyma stress relaxation using fractional viscoelasticity.

    abstract::Some pulmonary diseases and injuries are believed to correlate with lung viscoelasticity changes. Hence, a better understanding of lung viscoelastic models could provide new perspectives on the progression of lung pathology and trauma. In the presented study, stress relaxation measurements were performed to quantify r...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.05.003

    authors: Dai Z,Peng Y,Mansy HA,Sandler RH,Royston TJ

    更新日期:2015-08-01 00:00:00