Abstract:
:Despite our understanding of the importance of falling, previous studies have ignored the effects of falls from standing height. In this article, lumped parameter linear and nonlinear models of a standing human have been used to simulate the impact response of the body segments due to inputs at the shoes. The acceleration transfer and frequency response were determined. The effect of nonlinear damping was simulated. Nonlinear effects were found to be most significant when the input amplitude increases. Frequency response attenuation was significant, resulting in almost a shift in the magnitude plots in the range (0.1-100 Hz) of frequency. When the input amplitude was reduced, the nonlinear effects became apparent only in the medium frequency range. In the case simulating a human subject exposed to impulse at the foot, a large amount of energy is dissipated in the joints due to the friction resulting in a joint disorder. This is most significant at the medium frequency range that is expected to be induced by a running human subject.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Jarrah M,Qassem W,Othman M,Gdeisat Mdoi
10.1016/s1350-4533(96)00081-1subject
Has Abstractpub_date
1997-06-01 00:00:00pages
308-16issue
4eissn
1350-4533issn
1873-4030pii
S1350453396000811journal_volume
19pub_type
杂志文章abstract::In case of large segmental defects in load-bearing bones, an external fixator is used to provide mechanical stability to the defect site. The overall stiffness of the bone-fixator system is determined not only by the fixator design but also by the way the fixator is mounted to the bone. This stiffness is an important ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.10.006
更新日期:2013-07-01 00:00:00
abstract::Segmentation of medical images is very important for clinical research and diagnosis, leading to a requirement for robust automatic methods. This paper reports on the combined use of a neural network (a multilayer perceptron, MLP) and active contour model ('snake') to segment structures in magnetic resonance (MR) imag...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/s1350-4533(03)00137-1
更新日期:2004-01-01 00:00:00
abstract::Contact interactions between the hand and handle, such as the contact surface softness and contact surface curvature, will affect both physical effort and musculoskeletal fatigue, thereby the comfort and safety of power tool operations. Previous models of hand gripping can be categorized into two groups: multi-body dy...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.03.007
更新日期:2014-07-01 00:00:00
abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.09.014
更新日期:2005-03-01 00:00:00
abstract::Interest in patient-specific blood-flow circulation modeling has increased substantially in recent years. The availability of clinical data for geometric and elastic properties together with efficient numerical methods has now made model rendering feasible. This work uses 3-D fluid-structure interaction (FSI) to provi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.08.009
更新日期:2013-06-01 00:00:00
abstract::Cerebral autoregulation (CA) is the mechanism that aims to maintain adequate cerebral perfusion during changes in blood pressure (BP). Transfer function analysis (TFA), the most reported method in literature to quantify CA, shows large between-study variability in outcomes. The aim of this study is to investigate the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.02.001
更新日期:2016-05-01 00:00:00
abstract:AIMS:This study investigated the feasibility of automated differentiation between essential tissue types encountered during laparoscopic colorectal surgery using spectral analysis. METHODS:Wide band (440-1830 nm) spectra were collected using an optical fiber probe and spectrometer from freshly explanted, ex vivo, huma...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.01.004
更新日期:2013-07-01 00:00:00
abstract::The mean value and standard deviation of localization error for the stereo imaging systems are derived based on probability theory. Compared with the maximum error analysis method used in our previous study, the new approach yields more informative and precise results as the guidance for X-ray imaging system design an...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00084-4
更新日期:2001-10-01 00:00:00
abstract::Precise evaluation of graft reperfusion is difficult in clinical liver transplantation. The oxygen electrode (OE) is a novel technique to detect blood flow indirectly by measuring the quantity of oxygen which can diffuse from the hepatic tissue to the surface electrode. Application of the surface OE does not influence...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00060-6
更新日期:2000-06-01 00:00:00
abstract::Biomagnetic investigations in basic physiological research using animals require measurement devices different from commercial biomagnetometers used in human investigations. Two major problems have to be tackled in the design of such biomagnetometers. First, the spatial sampling needs to be much higher. Second, the di...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(99)00088-0
更新日期:1999-10-01 00:00:00
abstract::This study describes the method of determination of the position and orientation of artificial knee implants using a single-plane radiograph. To simplify the 3D/2D matching problem, we proposed to use small markers embedded in a bone. From the image coordinates of markers, it is possible to estimate the position and o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(03)00037-7
更新日期:2003-06-01 00:00:00
abstract::In the fields of medicine and biomechanics, MEMS accelerometers are increasingly used to perform activity recognition by directly measuring acceleration; to calculate speed and position by numerical integration of the signal; or to estimate the orientation of body parts in combination with gyroscopes. For some of thes...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2016.08.004
更新日期:2016-11-01 00:00:00
abstract::We present single fibre heart activity model (SFHAM) based on the current flow through the five bunches of fibres of the cardiac muscle (CM). The five effective fibres are identified and assigned to the appropriate segments of CM. Analytical functions describing ionic flows along the fibres are derived and proposed. T...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.08.007
更新日期:2009-12-01 00:00:00
abstract::Despite its medical relevance, accurate recognition of sedentary (sitting and lying) and dynamic activities (e.g. standing and walking) remains challenging using a single wearable device. Currently, trunk-worn wearable systems can differentiate sitting from standing with moderate success, as activity classifiers often...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.01.001
更新日期:2014-06-01 00:00:00
abstract::The pulse pressure waveform has, for long, been known as a fundamental biomedical signal and its analysis is recognized as a non-invasive, simple, and resourceful technique for the assessment of arterial vessels condition observed in several diseases. In the current paper, waveforms from non-invasive optical probe tha...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.07.014
更新日期:2014-11-01 00:00:00
abstract::Tripolar nerve cuff electrodes have been widely used for measuring peripheral nerve activity. However, despite the high signal-to-noise ratio levels that can be achieved with this recording configuration, the clinical use of cuff electrodes in closed-loop controlled neuroprostheses remains limited. This is largely att...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.11.010
更新日期:2017-02-01 00:00:00
abstract::Automated methods of neonatal EEG seizure detection attempt to highlight the evolving, stereotypical, pseudo-periodic, nature of EEG seizure while rejecting the nonstationary, modulated, coloured stochastic background in the presence of various EEG artefacts. An important aspect of neonatal seizure detection is, there...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.08.001
更新日期:2012-05-01 00:00:00
abstract::Easy insertion of the implant and stable bone purchase is essential for an ideal dental implantation. At the implant tip, the cutting flutes and conical profile are respectively designed to reduce insertion resistance and facilitate the initial insertion. However, the tapered tip might reduce the self-tapping and bone...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.09.021
更新日期:2012-09-01 00:00:00
abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.04.009
更新日期:2013-11-01 00:00:00
abstract::An inertial measurement unit (IMU) allows kinematic evaluation of human motion with fewer operational constraints than a gold standard optoelectronic motion capture (MOCAP) system. The study's aim was to compare IMU and MOCAP measurements of dynamic pelvic orientation angles during different activities of daily life (...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.11.009
更新日期:2016-03-01 00:00:00
abstract::This article reviews the role of cavitation in the therapeutic applications of ultrasound and laser surgery, and the cavitation effects in mechanical heart valves. Whenever laser pulses are used to ablate or disrupt tissue in a liquid environment, cavitation bubbles are produced which interact with the tissue. The int...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2009.03.007
更新日期:2009-09-01 00:00:00
abstract::This paper reports on the findings of an extensive survey investigating practising design engineers' perceptions of new product development within the UK medical device industry. The design activity recorded was predominantly the small-scale development of low volume products. Explicit formal procedures were rarely us...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00021-5
更新日期:1996-12-01 00:00:00
abstract::Fitts' Law was extended in the polar coordinate system, and a set of indices for human motion evaluation is proposed. In this paper, the index of difficulty and the index of performance are introduced as the general indices for the quality measure of plane target-to-target movement. As an example, the target-reaching ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00121-7
更新日期:2002-03-01 00:00:00
abstract::The strains developed on the surface of a femur with and without an implanted femoral hip replacement were investigated using holographic interferometry (HI). Interferometric fringe data from the four aspects of the loaded femur were quantified and the resulting curvature calculated. Curvature was related to the strai...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00003-4
更新日期:1998-03-01 00:00:00
abstract::The paper described a limited part of the coagulation pathway, and in particular the inhibitory effects of activated protein C in the context of thrombin production. This is a computational modeling study with various assumption made of kinetic rates laws and their summation. The level of complexity and assumed parame...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.01.003
更新日期:2004-05-01 00:00:00
abstract::Miniaturized and parallelized sandwich immunoassays allow the simultaneous analysis of a variety of parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. To study inflammatory diseases, protein arrays can be used to an...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2008.01.003
更新日期:2008-10-01 00:00:00
abstract::The Fit4Purpose project aims to develop upper limb prosthetic devices which are suitable for deployment in lower- and middle-income countries (LMIC's). Open-frame trans-radial socket designs are being considered, formed of several, linked components, including pads which interface directly with the skin surface. A mec...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.08.003
更新日期:2020-10-01 00:00:00
abstract::Aims of the present study were to test the hypotheses that (1) the compressive properties of articular cartilage are affected more by changes in the medium ionic concentration than the tensile properties, (2) collagen network controls the compression-tension nonlinearity of articular cartilage, and (3) proteoglycan (P...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.11.004
更新日期:2010-03-01 00:00:00
abstract::Knowledge about the human skin mechanical properties is essential in several domains, particularly for dermatology, cosmetic or to detect some cutaneous pathology. This study proposes a new method to determine the human skin mechanical properties in vivo using the indentation test. Usually, the skin mechanical paramet...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2007.06.011
更新日期:2008-06-01 00:00:00
abstract::Some pulmonary diseases and injuries are believed to correlate with lung viscoelasticity changes. Hence, a better understanding of lung viscoelastic models could provide new perspectives on the progression of lung pathology and trauma. In the presented study, stress relaxation measurements were performed to quantify r...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.05.003
更新日期:2015-08-01 00:00:00