The effects of flute shape and thread profile on the insertion torque and primary stability of dental implants.

Abstract:

:Easy insertion of the implant and stable bone purchase is essential for an ideal dental implantation. At the implant tip, the cutting flutes and conical profile are respectively designed to reduce insertion resistance and facilitate the initial insertion. However, the tapered tip might reduce the self-tapping and bone-purchasing abilities of the flutes and the tip threads. Using sawbone blocks as standard specimens, this study experimentally measures the insertion torque, holding power, and bending strength of eight varieties of implant (4 shapes×2 profiles). The bony contact, interfacial mechanism, and the altered shape of the flutes, at different section planes, are used to explain the experimental results. The results reveal that the bone-implant gaps at the tip region significantly suppress both the self-tapping and bone-purchasing abilities of the flutes and the tip threads. This makes initial insertion of the conical implant easier. However, the conical implant eventually requires a higher insertion torque and holding power, due to tighter bony contact, at the tail threads. The bowl-fluted design has the least flute space to store the squeezed bone chips, so both insertion torque and bending strength are significantly higher. For the conical group, the holding powers of three flute designs are nearly comparable. Overall, the conical implant with bowl flutes is the optimal design, with a lower resistance to initial insertion and higher stability, for final instrumentation.

journal_name

Med Eng Phys

authors

Wu SW,Lee CC,Fu PY,Lin SC

doi

10.1016/j.medengphy.2011.09.021

subject

Has Abstract

pub_date

2012-09-01 00:00:00

pages

797-805

issue

7

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(11)00247-5

journal_volume

34

pub_type

杂志文章
  • Effects of cartilage rings on airflow and particle deposition in the trachea and main bronchi.

    abstract::In most computational fluid dynamic (CFD) analysis of the human lung, it has been assumed that the trachea and branches of the lung have smooth walls. In order to determine if this is a valid assumption, the effects of cartilage rings on airflow and particle deposition in the lungs was determined through conducting si...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.06.010

    authors: Russo J,Robinson R,Oldham MJ

    更新日期:2008-06-01 00:00:00

  • Study of human-machine physical interface for wearable mobility assist devices.

    abstract::A decrease in mobility, related to illness, trauma or ageing, negatively affects the quality of life of the rapidly growing elderly population. A promising solution to maintain this standard of living is powered wearable mobility assist devices. Although they have achieved technological breakthroughs in the last decad...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.03.008

    authors: Levesque L,Doumit M

    更新日期:2020-06-01 00:00:00

  • Functional evaluation of natural sensory feedback incorporated in a hand grasp neuroprosthesis.

    abstract::We investigated whether automatic control of a hand grasp neuroprosthesis by means of signals from natural sensors in the skin of the index finger can mimic the natural control of grasp force in an important task of daily living, namely eating. We designed a simulated eating task with the same ratio of rest and activi...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.03.002

    authors: Inmann A,Haugland M

    更新日期:2004-07-01 00:00:00

  • Validated computational framework for efficient systematic evaluation of osteoporotic fracture fixation in the proximal humerus.

    abstract::The high rate of fixation failure in osteoporotic proximal humerus fractures indicate the need for improved solutions. Computer simulations may help to overcome the limitations of the gold standard biomechanical testing in evaluating the performance of new implants and enhance the effectivity and outcome of the design...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.04.011

    authors: Varga P,Inzana JA,Gueorguiev B,Südkamp NP,Windolf M

    更新日期:2018-07-01 00:00:00

  • Micro-CT evaluation of bone defects: applications to osteolytic bone metastases, bone cysts, and fracture.

    abstract::Bone defects can occur in various forms and present challenges to performing a standard micro-CT evaluation of bone quality because most measures are suited to homogeneous structures rather than ones with spatially focal abnormalities. Such defects are commonly associated with pain and fragility. Research involving bo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.016

    authors: Buie HR,Bosma NA,Downey CM,Jirik FR,Boyd SK

    更新日期:2013-11-01 00:00:00

  • Personalized 3D reconstruction of the rib cage for clinical assessment of trunk deformities.

    abstract::Scoliosis is a 3D deformity of the spine and rib cage. Extensive validation of 3D reconstruction methods of the spine from biplanar radiography has already been published. In this article, we propose a novel method to reconstruct the rib cage, using the same biplanar views as for the 3D reconstruction of the spine, to...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.06.002

    authors: Grenier S,Parent S,Cheriet F

    更新日期:2013-11-01 00:00:00

  • A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant.

    abstract::This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired wi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.006

    authors: Pan MC,Zhuang HB,Chen CS,Wu JW,Lee SY

    更新日期:2013-12-01 00:00:00

  • Variation of the impact duration during the in vitro insertion of acetabular cup implants.

    abstract::The acetabular cup (AC) is an implant impacted into a bone cavity and used for hip prosthesis surgery. Initial stability of the AC is an important factor for long term surgical success. The aim of this study is to determine the variations of the impact duration during AC implant insertion. Twenty-two bone samples take...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.005

    authors: Mathieu V,Michel A,Flouzat Lachaniette CH,Poignard A,Hernigou P,Allain J,Haïat G

    更新日期:2013-11-01 00:00:00

  • Electrochemistry of nanoscale DNA surface films on carbon.

    abstract::A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2006.05.009

    authors: Oliveira-Brett AM,Paquim AM,Diculescu VC,Piedade JA

    更新日期:2006-12-01 00:00:00

  • On the secondary stability of coated cementless hip replacement: parameters that affected interface strength.

    abstract::Unlike primary stability of coated cementless implants, their secondary stability has been poorly studied. This paper considers some theoretical aspects of the secondary stability of a coated cementless hip implant in a human femur. The bone is separated from the implant by a thin layer of microscopic peaks and trough...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00099-7

    authors: Orlik J,Zhurov A,Middleton J

    更新日期:2003-12-01 00:00:00

  • Development and evaluation of a semi-automatic technique for determining the bilateral symmetry plane of the facial skeleton.

    abstract::During reconstructive surgery of the face, one side may be used as a template for the other, exploiting assumed bilateral facial symmetry. The best method to calculate this plane, however, is debated. A new semi-automatic technique for calculating the symmetry plane of the facial skeleton is presented here that uses s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.06.006

    authors: Willing RT,Roumeliotis G,Jenkyn TR,Yazdani A

    更新日期:2013-12-01 00:00:00

  • TETRA mobile radios interfere with electroencephalography recording equipment.

    abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.009

    authors: Fouquet NC,Hawken MB,Elliott P,Burgess AP

    更新日期:2013-11-01 00:00:00

  • Detection of cardiac late potentials in nonstationary noise.

    abstract::An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00069-0

    authors: Atarius R,Sörnmo L

    更新日期:1997-04-01 00:00:00

  • The effect of compressive deformations on the rate of build-up of oxygen in isolated skeletal muscle cells.

    abstract::In this study we integrated between confocal-based cell-specific finite element (FE) modeling and Virtual Cell (VC) transport simulations in order to determine trends of relationship between externally applied compressive deformations and build-up rates of oxygen in myoblast cells, and to further test how mild culture...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.008

    authors: Leopold E,Sopher R,Gefen A

    更新日期:2011-11-01 00:00:00

  • Effect of different inertial parameter sets on joint moment calculation during stair ascending and descending.

    abstract::The reliability of internal joint moment calculation in gait analysis during daily living activities is fundamental for clinical decisions based on joint function. This calculation, obtained by means of the inverse dynamics, depends on several modelling factors, such as assumptions on the segments and on the relevant ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.12.002

    authors: Fantozzi S,Stagni R,Cappello A,Leardini A

    更新日期:2005-07-01 00:00:00

  • Model-based physiomarkers of cerebral hemodynamics in patients with mild cognitive impairment.

    abstract::In our previous studies, we have introduced model-based "functional biomarkers" or "physiomarkers" of cerebral hemodynamics that hold promise for improved diagnosis of early-stage Alzheimer's disease (AD). The advocated methodology utilizes subject-specific data-based dynamic nonlinear models of cerebral hemodynamics ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.025

    authors: Marmarelis VZ,Shin DC,Orme ME,Zhang R

    更新日期:2014-05-01 00:00:00

  • A comparative study on different methods of automatic mesh generation of human femurs.

    abstract::The aim of this study was to evaluate comparatively five methods for automating mesh generation (AMG) when used to mesh a human femur. The five AMG methods considered were: mapped mesh, which provides hexahedral elements through a direct mapping of the element onto the geometry; tetra mesh, which generates tetrahedral...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(97)00049-0

    authors: Viceconti M,Bellingeri L,Cristofolini L,Toni A

    更新日期:1998-01-01 00:00:00

  • Regression-based indices of fatigue in paraplegics' electrically stimulated quadriceps.

    abstract::We studied muscle fatigue in 19 paraplegic patients during an isometric sustained contraction. Both quadriceps (n = 38) were maximally stimulated for 126 s. We defined a nonlinear equation with four coefficients to fit the data and extract fatigue indices carrying information on the amount (asymptotic values, torque c...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(97)00038-6

    authors: Rabischong E,Chavet P

    更新日期:1997-12-01 00:00:00

  • A biomechanical model to determine lumbosacral loads during single stance phase in normal gait.

    abstract::A dynamic biomechanical model to determine loads (joint forces) attained at the lumbosacral joint-centre during the stance phase of normal level walking was developed. The biomechanical model was based on rigid free body-segments; namely, the foot, shank, thigh, pelvis and head, arms and trunk (HAT) segments. In this ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)90374-k

    authors: Khoo BC,Goh JC,Bose K

    更新日期:1995-01-01 00:00:00

  • Multispectral characterization of tissues encountered during laparoscopic colorectal surgery.

    abstract:AIMS:This study investigated the feasibility of automated differentiation between essential tissue types encountered during laparoscopic colorectal surgery using spectral analysis. METHODS:Wide band (440-1830 nm) spectra were collected using an optical fiber probe and spectrometer from freshly explanted, ex vivo, huma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.01.004

    authors: Schols RM,Dunias P,Wieringa FP,Stassen LP

    更新日期:2013-07-01 00:00:00

  • Mechanical behaviour of DNA molecules--elasticity and migration.

    abstract::A novel multi-scale simulation method developed to describe mesoscale phenomena occurring in biofluidic devices is presented. The approach combines the macro-scale modelling of the carrier fluid and the micro-scale description of the transported macromolecules or compounds. Application of the approach is demonstrated ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.003

    authors: Benke M,Shapiro E,Drikakis D

    更新日期:2011-09-01 00:00:00

  • A predictive study of the mechanical behaviour of coronary stents by computer modelling.

    abstract::Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent expansion is an important factor to define the effectiveness of the surgical procedure: it depends on the stent geometry and includes large displacements and deformat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.08.012

    authors: Migliavacca F,Petrini L,Montanari V,Quagliana I,Auricchio F,Dubini G

    更新日期:2005-01-01 00:00:00

  • Ensemble framework based real-time respiratory motion prediction for adaptive radiotherapy applications.

    abstract::Successful treatment of tumors with motion-adaptive radiotherapy requires accurate prediction of respiratory motion, ideally with a prediction horizon larger than the latency in radiotherapy system. Accurate prediction of respiratory motion is however a non-trivial task due to the presence of irregularities and intra-...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.04.021

    authors: Tatinati S,Nazarpour K,Tech Ang W,Veluvolu KC

    更新日期:2016-08-01 00:00:00

  • Minimization of the knee shear joint load in leg-extension equipment.

    abstract::We developed an analytical biomechanical model for leg-extension equipment and the associated knee-extension/flexion exercises. The shear component, phi(t), of the tibiofemoral joint load was calculated taking into account all the fundamental elements of the equipment mechanics (resistance pad placement, cam/pulley sy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.12.012

    authors: Biscarini A

    更新日期:2008-10-01 00:00:00

  • Measurement of thermal conductivity of bovine cortical bone.

    abstract::The thermal conductivity of cortical bone was characterized experimentally. Specimens were taken from the mid-diaphysis of bovine femora, and the rate of heat transfer was measured in three orthogonal directions. The conductivity was found to be 0.58+/-0.018 W/mK in the longitudinal direction, 0.53+/-0.030 W/mK in the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00003-0

    authors: Davidson SR,James DF

    更新日期:2000-12-01 00:00:00

  • Nintendo® Wii Fit based sleepiness tester detects impairment of postural steadiness due to 24 h of wakefulness.

    abstract::A field-usable sleepiness tester could reduce sleepiness related accidents. 15 subjects' postural steadiness was measured with a Nintendo(®) Wii Fit balance board every hour for 24 h. Body sway was quantified with complexity index, CI, and the correlation between CI and alertness predicted by a three-process model of ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.08.007

    authors: Tietäväinen A,Gates FK,Meriläinen A,Mandel JE,Hæggström E

    更新日期:2013-12-01 00:00:00

  • Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems.

    abstract::Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Ti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.011

    authors: Jauch SY,Coles LG,Ng LV,Miles AW,Gill HS

    更新日期:2014-09-01 00:00:00

  • Compressive and tensile properties of articular cartilage in axial loading are modulated differently by osmotic environment.

    abstract::Aims of the present study were to test the hypotheses that (1) the compressive properties of articular cartilage are affected more by changes in the medium ionic concentration than the tensile properties, (2) collagen network controls the compression-tension nonlinearity of articular cartilage, and (3) proteoglycan (P...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.11.004

    authors: Korhonen RK,Jurvelin JS

    更新日期:2010-03-01 00:00:00

  • Experimental determination of the emissivity of bone.

    abstract::Cutting and drilling operations in bone are involved in many orthopedic and otolaryngological surgeries. The temperature elevation of these procedures is potentially harmful to bone and soft tissue cells. The research on this topic aims therefore at minimizing temperature elevation and finding optimal process paramete...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.06.019

    authors: Feldmann A,Zysset P

    更新日期:2016-10-01 00:00:00

  • Preliminary observations on the presence of sustained tendon strain and eccentric contractions of the wrist extensors during a common manual task: implications for lateral epicondylitis.

    abstract::Lateral epicondylitis (LE) is hypothesized to occur as a result of repetitive, strenuous and abnormal postural activities of the elbow and wrist. There is still a lack of understanding of how wrist and forearm positions contribute to this condition during common manual tasks. In this study the wrist kinematics and the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.02.002

    authors: Murgia A,Harwin W,Prakoonwit S,Brownlow H

    更新日期:2011-07-01 00:00:00