Variation of the impact duration during the in vitro insertion of acetabular cup implants.

Abstract:

:The acetabular cup (AC) is an implant impacted into a bone cavity and used for hip prosthesis surgery. Initial stability of the AC is an important factor for long term surgical success. The aim of this study is to determine the variations of the impact duration during AC implant insertion. Twenty-two bone samples taken from bovine femurs were prepared ex vivo for the insertion of an acetabular cup implant, following the surgical procedure used in the clinic. For each bone sample, ten impacts were applied using reproducible mass falls (3.5 kg) in order to insert the AC implant. Each impact duration was recorded using a wide bandwidth force sensor. For all bone samples, the impact duration was shown to first decrease as a function of the impact number, then reaching a stationary value equal in average to 4.2±0.7 ms after an average number of 4.1±1.7 impacts. The impact duration may be related to variations of the bone-implant interface contact rigidity because of an increase the amount of bone tissue in contact with the AC implant. Measurements of impact duration have a good potentiality for clinical application to assist the surgeon during the insertion of the AC implant, providing valuable information on the bone-implant interface contact properties.

journal_name

Med Eng Phys

authors

Mathieu V,Michel A,Flouzat Lachaniette CH,Poignard A,Hernigou P,Allain J,Haïat G

doi

10.1016/j.medengphy.2013.04.005

subject

Has Abstract

pub_date

2013-11-01 00:00:00

pages

1558-63

issue

11

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(13)00098-2

journal_volume

35

pub_type

杂志文章
  • A computational model-based study on the exchangeability of hepatic venous pressure gradients measured in multiple hepatic veins.

    abstract::Hepatic venous pressure gradient (HVPG) is a hemodynamic index widely used for evaluating the severity of portal hypertension. Theoretically, HVPG can be measured in any of the three major (i.e., right, middle and left) hepatic veins (HVs); however, it remains unclear whether HVPGs measured in different HVs are exchan...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.07.022

    authors: Wang T,Liang F,Li L,Zhang W,Wang G,Wang J,Zhang C,Qi X

    更新日期:2020-10-01 00:00:00

  • Characterizing atypical patterns of Heart Rate before Paroxysmal Ventricular Tachycardia.

    abstract::Results of a comparative analysis between Heart Rate (HR) patterns occurring before the onset of Paroxysmal Ventricular Tachycardia (PVT) and from healthy subjects are shown. Two study groups were made after electrocardiographic dynamical monitoring (Holter) of volunteers. The first group includes 100h from 27 healthy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.004

    authors: Alvarez E,Jiménez J,Moleiro F,Rodríguez A

    更新日期:2010-12-01 00:00:00

  • Reconstruction of dental ultrasonic scaler 3D vibration patterns from phase-related data.

    abstract::Ultrasonic scalers are used in dentistry for removing mineralised plaque, known as calculus, from tooth surfaces. Though there is much information relating to the longitudinal vibrations of scaler probes, corresponding lateral data is limited. Understanding the lateral motion of ultrasonic probes is essential as, when...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.02.010

    authors: Lea SC,Landini G

    更新日期:2010-07-01 00:00:00

  • The effect of compressive deformations on the rate of build-up of oxygen in isolated skeletal muscle cells.

    abstract::In this study we integrated between confocal-based cell-specific finite element (FE) modeling and Virtual Cell (VC) transport simulations in order to determine trends of relationship between externally applied compressive deformations and build-up rates of oxygen in myoblast cells, and to further test how mild culture...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.008

    authors: Leopold E,Sopher R,Gefen A

    更新日期:2011-11-01 00:00:00

  • The carotid artery as an alternative site for dynamic autoregulation measurement: an inter-observer reproducibility study.

    abstract::The internal carotid artery (ICA) has been proposed as an alternative site to the middle cerebral artery (MCA) to measure dynamic cerebral autoregulation (dCA) using transcranial Doppler ultrasound (TCD). Our aim was to test the inter-operator reproducibility of dCA assessment in the ICA and the effect of interaction ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.03.007

    authors: Nogueira RC,Saeed NP,Bor-Seng-Shu E,Teixeira MJ,Robinson TG,Panerai RB

    更新日期:2016-07-01 00:00:00

  • Laser fabrication of electrical feedthroughs in polymer encapsulations for active implantable medical devices.

    abstract::Hermetic electrical feedthroughs are essential for safe and functional active implantable biomedical devices and for a wide range of other applications such as batteries, supercapacitors, OLEDs and solar cells. Ceramics and metals have previously been the materials of choice for encapsulations, while polymers have adv...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.01.010

    authors: Gough Z,Chaminade C,Barclay-Monteith P,Kallinen A,Lei W,Ganesan R,Grace J,McKenzie DR

    更新日期:2017-04-01 00:00:00

  • Can a 15m-overground wheelchair sprint be used to assess wheelchair-specific anaerobic work capacity?

    abstract:OBJECTIVE:To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint (WAnT). METHODS:Able-bodie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.003

    authors: van der Scheer JW,de Groot S,Vegter RJ,Veeger DH,van der Woude LH

    更新日期:2014-04-01 00:00:00

  • Suspension microarrays for the identification of the response patterns in hyperinflammatory diseases.

    abstract::Miniaturized and parallelized sandwich immunoassays allow the simultaneous analysis of a variety of parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. To study inflammatory diseases, protein arrays can be used to an...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.01.003

    authors: Hsu HY,Wittemann S,Schneider EM,Weiss M,Joos TO

    更新日期:2008-10-01 00:00:00

  • Detection of hidden rhythms in surface EMG signals with a non-linear time-series tool.

    abstract::The analysis of the surface electromyographic (sEMG) signal is particularly attractive because it provides relatively easy access to those physiological processes that allow the muscle to generate force and movement. In this paper, one of the possible applications of recurrence plot strategy to the analysis of sEMG is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00073-9

    authors: Filligoi G,Felici F

    更新日期:1999-07-01 00:00:00

  • Computation of the elastic properties of a resin impregnated wire mesh by the means of a homogenisation procedure.

    abstract::The present paper presents a homogenisation technique applied to the problem of calculating equivalent material properties of a resin impregnated wire mesh. Although this type of material can be expected to possess, in general, a four-fold axis of rotational symmetry, it was found that a transversally isotropic model ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00065-5

    authors: Hübsch PF,Middleton J,Knox J

    更新日期:2000-09-01 00:00:00

  • A 16-channel SQUID-device for biomagnetic investigations of small objects.

    abstract::Biomagnetic investigations in basic physiological research using animals require measurement devices different from commercial biomagnetometers used in human investigations. Two major problems have to be tackled in the design of such biomagnetometers. First, the spatial sampling needs to be much higher. Second, the di...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00088-0

    authors: Nowak H,Giessler F,Huonker R,Haueisen J,Röther J,Eiselt M

    更新日期:1999-10-01 00:00:00

  • A non-invasive Cochlear Microphonic measurement system.

    abstract::The Cochlear Microphonic is one of the electrical potentials generated by the ear in response to audible stimuli. It is very difficult to measure the CM non-invasively because it has a very small magnitude (less than 1 μV). A high Common Mode Rejection Ratio (CMRR) and very large bandwidth (5 Hz-20 kHz) biomedical amp...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.017

    authors: Masood A,Teal PD,Hollitt C

    更新日期:2012-10-01 00:00:00

  • Resonant frequency analysis of dental implants.

    abstract::Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing stead...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.02.008

    authors: Rittel D,Dorogoy A,Haïat G,Shemtov-Yona K

    更新日期:2019-04-01 00:00:00

  • A practical technique for measuring human biofluid conductivity using high gain-frequency characteristics.

    abstract::Currently, the study of ion composition and performance in human biofluids plays an important role in biomedical engineering research and technology. This field may become universal for human diagnostics; it allows early detection of different diseases in humans by measuring changes in ion behaviour in human biofluids...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.007

    authors: Al-Nabulsi JI,Aloquili O,Ausheva V,Yuldashev ZM

    更新日期:2011-11-01 00:00:00

  • Design of a biodegradable plate for femoral shaft fracture fixation.

    abstract::Biodegradable materials have been generating increasing bit of interest in biomedical applications and associated research. The evolution of implants made up of such materials (Mg-alloys, etc.) has the potential to be a game changer in fracture surgeries. These implants are essentially made up of a plate and a number ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.05.010

    authors: Chandra G,Pandey A,Pandey S

    更新日期:2020-07-01 00:00:00

  • A new method for long-term home monitoring of fetal movement by pregnant women themselves.

    abstract::Fetal movement is one index of fetal well-being. We designed and built a new recorder based on fetal movement acceleration measurement (FMAM). The FMAM recorder has a newly developed, capacitive acceleration sensor that can detect the oscillations of the maternal abdominal wall caused by fetal movements. In this study...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.001

    authors: Ryo E,Nishihara K,Matsumoto S,Kamata H

    更新日期:2012-06-01 00:00:00

  • Enabling variable-stiffness hand rehabilitation orthoses with dielectric elastomer transducers.

    abstract::Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.10.015

    authors: Carpi F,Frediani G,Gerboni C,Gemignani J,De Rossi D

    更新日期:2014-02-01 00:00:00

  • A method of examining the magnitude and origin of "soft" and "hard" tissue forces resisting limb lengthening.

    abstract::Complications arising from limb-lengthening procedures such as muscle contracture, axial malalignment of the bone and traction injuries to the nerves and vessels, are often severe. Often complications arise from the build-up of forces in the biological tissues which are resisting lengthening. Little is known about the...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s1350-4533(97)00010-6

    authors: Gardner TN,Evans M,Simpson AH,Kyberd PJ,Kenwright J

    更新日期:1997-07-01 00:00:00

  • Linear and nonlinear analyses of multi-channel mechanomyographic recordings reveal heterogeneous activation of wrist extensors in presence of delayed onset muscle soreness.

    abstract::In this study, we applied multi-channel mechanomyographic (MMG) recordings in combination with linear and nonlinear analyses to investigate muscular and musculotendinous effects of high intensity eccentric exercise. Twelve accelerometers arranged in a 3 × 4 matrix over the dominant elbow muscles were used to detect MM...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.003

    authors: Madeleine P,Hansen EA,Samani A

    更新日期:2014-12-01 00:00:00

  • A microfluidic device for continuous manipulation of biological cells using dielectrophoresis.

    abstract::The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate no...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.010

    authors: Das D,Biswas K,Das S

    更新日期:2014-06-01 00:00:00

  • In-vitro validation of a non-invasive dual fluoroscopic imaging technique for measurement of the hip kinematics.

    abstract::Measurement of accurate in vivo hip joint kinematics in 6-DOF is difficult. Few studies have reported non-invasive measurements of the hip kinematics. The objective of this study was to validate a non-invasive dual fluoroscopic imaging system (DFIS) for measurement of hip kinematics. Bi-lateral hip joints of a cadaver...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.004

    authors: Lin H,Wang S,Tsai TY,Li G,Kwon YM

    更新日期:2013-03-01 00:00:00

  • Separation of electrocardiographic from electromyographic signals using dynamic filtration.

    abstract::Trunk muscle electromyographic (EMG) signals are often contaminated by the electrical activity of the heart. During low or moderate muscle force, these electrocardiographic (ECG) signals disturb the estimation of muscle activity. Butterworth high-pass filters with cut-off frequency of up to 60 Hz are often used to sup...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.04.007

    authors: Christov I,Raikova R,Angelova S

    更新日期:2018-07-01 00:00:00

  • Numerical simulation of the flow of aqueous humor in the Schlemm's canal.

    abstract::Schlemm's canal (SC) is a ring structure responsible for maintaining fluid homeostasis in the anterior chamber of the eye by draining aqueous humor (AH) from the trabecular meshwork (TM) into the collecting channel (CC). Obstruction of the AH flow in this conventional pathway leads to an elevation of intraocular press...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.12.005

    authors: Guo JM,Chen ZQ,Chen W,Yan XQ,Zhang H,Wang JM

    更新日期:2021-02-01 00:00:00

  • Three-dimensional analysis and visualization of regional MR signal intensity distribution of articular cartilage.

    abstract::The aim of this study was to develop a technique for analyzing and visualizing the regional, three-dimensional signal intensity distribution of articular cartilage in MR images, as a potential surrogate marker of structural or biochemical alterations in early osteoarthritis. Exemplary MR-images of human patellae were ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00006-1

    authors: Hohe J,Faber S,Muehlbauer R,Reiser M,Englmeier KH,Eckstein F

    更新日期:2002-04-01 00:00:00

  • Assessment of gait sensitivity norm as a predictor of risk of falling during walking in a neuromusculoskeletal model.

    abstract::Quantifying the risk of falling (falls risk) would be helpful in treating people with gait disorders. The gait sensitivity norm (GSN) is a stability measure that correlates well to risk of falling in passive dynamic walkers but has not been evaluated on humans or human-like walking models. We assessed the correlation ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.018

    authors: Thangal SN,Talaty M,Balasubramanian S

    更新日期:2013-10-01 00:00:00

  • Computational fluid dynamic simulations of cavopulmonary connections with an extracardiac lateral conduit.

    abstract::Complex congenital heart defects due to the absence of a ventricular chamber can often be treated by the Fontan surgical procedure. The objective of this work was to quantify the haemodynamics in the Fontan operation (cavopulmonary connection) with extracardiac lateral conduit. Four different models based on the finit...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00042-9

    authors: Migliavacca F,de Leval MR,Dubini G,Pietrabissa R,Fumero R

    更新日期:1999-04-01 00:00:00

  • Assessing the sound of cough towards vocality.

    abstract::The presented research positively evaluates the vocality of the cough sound by estimating the global cough fundamental frequency or pitch. The fundamental frequency was determined by autocorrelation analysis on both the original time-signal and the linear predicted time-signal. The experimental cough database was regi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00055-3

    authors: Van Hirtum A,Berckmans D

    更新日期:2002-09-01 00:00:00

  • Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems.

    abstract::Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Ti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.011

    authors: Jauch SY,Coles LG,Ng LV,Miles AW,Gill HS

    更新日期:2014-09-01 00:00:00

  • Shape-memory-alloy-based smart knee spacer for total knee arthroplasty: 3D CAD modelling and a computational study.

    abstract::This study introduced a shape memory alloy (SMA)-based smart knee spacer for total knee arthroplasty (TKA). Subsequently, a 3D CAD model of a smart tibial component of TKA was designed in Solidworks software, and verified using a finite element analysis in ANSYS Workbench. The two major properties of the SMA (NiTi), t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.03.001

    authors: Gautam A,Callejas MA,Acharyya A,Acharyya SG

    更新日期:2018-05-01 00:00:00

  • Using robotic mechanical perturbations for enhanced balance assessment.

    abstract::Balance impairment is critical for many patient groups such as those with neural and musculoskeletal disorders and also the elderly. Accurate and objective assessment of balance performance has led to the development of several indices based on the measurement of the center of pressure. In this study, a robotic device...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.07.006

    authors: Baselizadeh A,Behjat A,Torabi A,Behzadipour S

    更新日期:2020-09-01 00:00:00