Abstract:
:A decrease in mobility, related to illness, trauma or ageing, negatively affects the quality of life of the rapidly growing elderly population. A promising solution to maintain this standard of living is powered wearable mobility assist devices. Although they have achieved technological breakthroughs in the last decade, their overall success is still hindered by their induced physical discomfort, which limits their effective and prolonged usage. The aim of this study is to achieve a comprehensive characterization of human-machine physical interface to further advance the performance of wearable mobility assist devices, specifically for the knee joint. This led the research group to design, fabricate, and instrument a low-cost modular knee orthosis testing apparatus with extension moment assist that allows multiple physical interface adjustment parameters. This device was conceived with the objective to conduct human testing while introducing design variables and operating parameters to evaluate device's performance. Using a force mapping apparatus and a motion capture system, the kinetic and the kinematic behaviour of the developed orthosis' physical interfaces were acquired. The results demonstrated varied impact on performance when introducing key design variables namely interface position, interface geometry, interface compliancy, interface hard-shell position, interface degree of freedom, and knee extension moment. This study provides an in-depth understanding of distinct user-device interface mechanisms and permitted an evaluation of optimum orthosis parameters to help further advance the state of wearable mobility assist devices.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Levesque L,Doumit Mdoi
10.1016/j.medengphy.2020.03.008subject
Has Abstractpub_date
2020-06-01 00:00:00pages
33-43eissn
1350-4533issn
1873-4030pii
S1350-4533(20)30049-7journal_volume
80pub_type
杂志文章abstract::The removal of the background from a noisy image to leave the object of interest, with well defined edges, is a difficult task. Images obtained using radioisotopes have low signal-to-noise ratios due to scattered photons, as well as emitted radiation from the background. Moreover, noise is, also, a consequence of the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00043-7
更新日期:1996-03-01 00:00:00
abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.04.002
更新日期:2010-06-01 00:00:00
abstract::We investigated whether automatic control of a hand grasp neuroprosthesis by means of signals from natural sensors in the skin of the index finger can mimic the natural control of grasp force in an important task of daily living, namely eating. We designed a simulated eating task with the same ratio of rest and activi...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/j.medengphy.2004.03.002
更新日期:2004-07-01 00:00:00
abstract::The high rate of fixation failure in osteoporotic proximal humerus fractures indicate the need for improved solutions. Computer simulations may help to overcome the limitations of the gold standard biomechanical testing in evaluating the performance of new implants and enhance the effectivity and outcome of the design...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2018.04.011
更新日期:2018-07-01 00:00:00
abstract::Tripolar nerve cuff electrodes have been widely used for measuring peripheral nerve activity. However, despite the high signal-to-noise ratio levels that can be achieved with this recording configuration, the clinical use of cuff electrodes in closed-loop controlled neuroprostheses remains limited. This is largely att...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.11.010
更新日期:2017-02-01 00:00:00
abstract::Recent approaches to the in vitro experimental study of cardiac fluid mechanics involve the use of whole biological structures to investigate in the lab novel therapeutic approaches for the treatment of heart pathologies. To enhance reliability and repeatability, the influence of the actuation strategy of the experime...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.01.007
更新日期:2016-04-01 00:00:00
abstract::Metal plates are commonly used in the operative treatment of bone fractures. Rigid metal plates stabilize the fracture site, maintain good contact between bone fragments and allow early weight bearing and patient mobility. However, treatment with rigid metal plates can cause localized bone atrophy due to stress-shield...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00041-0
更新日期:1996-04-01 00:00:00
abstract::The mean value and standard deviation of localization error for the stereo imaging systems are derived based on probability theory. Compared with the maximum error analysis method used in our previous study, the new approach yields more informative and precise results as the guidance for X-ray imaging system design an...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00084-4
更新日期:2001-10-01 00:00:00
abstract::Locking compression plates (LCPs) have been used to fix femoral shaft fractures. Previous studies have attempted to identify the best LCP screw positions and numbers to achieve the fixation stability. However, the determined screw positions and numbers were mainly based on the surgeons' experiences. The aim of this st...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.09.005
更新日期:2014-01-01 00:00:00
abstract::Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing stead...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.02.008
更新日期:2019-04-01 00:00:00
abstract::A DNA electrochemical biosensor is an integrated receptor-transducer device. The most important step in the development and manufacture of a sensitive DNA-biosensor for the detection of DNA-drug interactions is the immobilization procedure of the nucleic acid probe on the transducer surface. Magnetic A/C Mode atomic f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2006.05.009
更新日期:2006-12-01 00:00:00
abstract::To reduce the time of computation of a motor unit potential (MUP), the shape of intracellular action potential (IAP) and (or) MU anatomy are generally simplified. A method of MUP presentation is suggested. It provides accuracy of the MUPs calculated for any distance and size of rectangular electrodes together with con...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00014-9
更新日期:1998-07-01 00:00:00
abstract::There are limited interface options for electric powered wheelchairs, which results in the inability of some individuals to drive independently. In addition, the development of new interface technologies will necessitate the development of alternative training methods. This study compares a conventional position sensi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00111-x
更新日期:2002-12-01 00:00:00
abstract::A small and wireless device that can capture the temporal pattern of perspiration by a novel structure of water vapor collection combined with reusable desiccant has been developed. The novel device consists of a small cylindrical case with a temperature/relative humidity sensor, battery-driven data logger, and silica...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.12.009
更新日期:2016-04-01 00:00:00
abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.12.003
更新日期:2016-03-01 00:00:00
abstract::Sclerosis rim surrounding the necrotic area is commonly found in necrotic femoral head, but the biomechanical function of sclerosis rim has received relatively little attention. Little is known about the formation and natural history of sclerosis rim. In the present work, we assume that the necrotic change may trigger...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.09.005
更新日期:2015-12-01 00:00:00
abstract::The current strategy for the control of tuberculosis (TB) relies on early diagnosis, and smear microscopy is an essential component of the laboratory diagnosis of TB in most countries with a high prevalence of the disease. However, even simple smear microscopy examination is far from satisfactory because staining resu...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00213-8
更新日期:2003-05-01 00:00:00
abstract::Individuals often use their wheelchair as a motor vehicle seat when traveling in motor vehicles. The current use of fixed vehicle-mounted wheelchair occupant restraint systems (FWORSs) often results in poor belt fit and discomfort. Additionally, satisfaction, usability and usage rate of FWORSs during transit use are o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00082-0
更新日期:2001-12-01 00:00:00
abstract::Various simulation models of different complexity have been proposed to model the dynamic response of the human cardiovascular system. In a related paper we proposed an improved numerical model to study the dynamic response of the cardiovascular system, and the pressures, volumes and flow-rates in the four chambers of...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.11.005
更新日期:2006-10-01 00:00:00
abstract::To investigate the features of the gastric interdigestive pressure activity under normal physiological conditions, we have developed the wireless radiotelemetry capsule based on a telemetry technique. Twelve healthy volunteers participated in this study. Pressure activity data which are an important index of gastric m...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2008.04.017
更新日期:2009-04-01 00:00:00
abstract::Post-myocardial infarction remodeling process is known to alter the mechanical properties of the heart. Biomechanical parameters, such as tissue stiffness and contractility, would be useful for clinicians to better assess the severity of the diseased heart. However, these parameters are difficult to obtain in the curr...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.09.003
更新日期:2020-11-01 00:00:00
abstract::An inertial measurement unit (IMU) allows kinematic evaluation of human motion with fewer operational constraints than a gold standard optoelectronic motion capture (MOCAP) system. The study's aim was to compare IMU and MOCAP measurements of dynamic pelvic orientation angles during different activities of daily life (...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.11.009
更新日期:2016-03-01 00:00:00
abstract::The second-order difference plot, as a modified Poincaré plot, is one of the important approaches for assessing the dynamics of heart rate variability. However, corresponding quantitative analysis methods are relatively limited. Based on the second-order difference plot, we propose a novel method, called the multi-sca...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.09.015
更新日期:2014-12-01 00:00:00
abstract::Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). Th...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.05.002
更新日期:2016-09-01 00:00:00
abstract::An ultrasonic aerosol generator constructed from a domestic humidifier is described which has been used to produce liquid aerosols for physiological investigations. The instrument was constructed from a Pifco domestic humidifier modified to include an energy guide to direct the oscillations of the transducer through t...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)97320-o
更新日期:1995-07-01 00:00:00
abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.12.004
更新日期:2020-02-01 00:00:00
abstract::This investigation explored pattern recognition of EMG signals produced by shoulder area muscles to identify the performance of a select number of lower arm motions. The signals were modelled as fourth-order autoregressive processes with the parameters of the models used to classify the different motions. The recorded...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(94)90024-8
更新日期:1994-03-01 00:00:00
abstract:INTRODUCTION:This study compared the initial viscoelastic properties of a segmental tibial defect stabilized with intramedullary nailing and impaction bone grafting to that of a transverse fracture stabilized with intramedullary nailing. MATERIALS AND METHODS:Seven sheep tibiae were tested in compression (1000N), bend...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.09.003
更新日期:2014-01-01 00:00:00
abstract::Dynamic models of the human trunk have been extensively used to investigate the biomechanics of lower back pain and postural instability in different populations. Despite their diverse applications, previous models rely on intrinsic upper body segment parameters (UBSP), e.g., each segment's mass-inertia characteristic...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.09.008
更新日期:2011-01-01 00:00:00
abstract::In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the poten...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.09.009
更新日期:2006-07-01 00:00:00