Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems.

Abstract:

:Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Titanium stems and cobalt-chromium heads were assembled with peak impaction forces of 4.5 kN or 6.0 kN and then mounted on a materials testing machine whilst immersed in Ringer's solution. The stems were subjected to a static axial load (1 kN or 3 kN) along the taper axis. After a period of equilibration, a torque ramp from 0 to 15 Nm was manually applied and the galvanic potential was continuously recorded. Prostheses assembled with a force of 6 kN required a significantly higher torque to start a removal of the passivation layer compared to those assembled with 4.5 kN (7.23±0.55 Nm vs. 3.92±0.97 Nm, p=0.029). No influence of the axial load on the fretting behaviour was found (p=0.486). The torque levels, which were demonstrated to initiate surface damage under either assembly force, can be readily reached during activities of daily living. The damage will be intensified in situations of large weight and high activity of the patient or malpositioning of the prosthesis.

journal_name

Med Eng Phys

authors

Jauch SY,Coles LG,Ng LV,Miles AW,Gill HS

doi

10.1016/j.medengphy.2014.06.011

subject

Has Abstract

pub_date

2014-09-01 00:00:00

pages

1140-6

issue

9

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(14)00151-9

journal_volume

36

pub_type

杂志文章
  • Biomechanical design using in-vitro finite element modeling of distal femur fracture plates made from semi-rigid materials versus traditional metals for post-operative toe-touch weight-bearing.

    abstract::This proof-of-concept study designs distal femur fracture plates from semi-rigid materials vs. traditional metals for toe-touch weight-bearing recommended to patients immediately after surgery. The two-fold goal was to (a) reduce stress shielding (SS) by increasing cortical bone stress thereby reducing the risk of bon...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.11.015

    authors: Gee A,Bougherara H,Schemitsch EH,Zdero R

    更新日期:2021-01-01 00:00:00

  • Study on gastric interdigestive pressure activity based on phase space reconstruction and FastICA algorithm.

    abstract::To investigate the features of the gastric interdigestive pressure activity under normal physiological conditions, we have developed the wireless radiotelemetry capsule based on a telemetry technique. Twelve healthy volunteers participated in this study. Pressure activity data which are an important index of gastric m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.04.017

    authors: Huang B,Yan G,Zan P,Li Q

    更新日期:2009-04-01 00:00:00

  • A computational model-based study on the exchangeability of hepatic venous pressure gradients measured in multiple hepatic veins.

    abstract::Hepatic venous pressure gradient (HVPG) is a hemodynamic index widely used for evaluating the severity of portal hypertension. Theoretically, HVPG can be measured in any of the three major (i.e., right, middle and left) hepatic veins (HVs); however, it remains unclear whether HVPGs measured in different HVs are exchan...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.07.022

    authors: Wang T,Liang F,Li L,Zhang W,Wang G,Wang J,Zhang C,Qi X

    更新日期:2020-10-01 00:00:00

  • Minimal haemodynamic system model including ventricular interaction and valve dynamics.

    abstract::Characterising circulatory dysfunction and choosing a suitable treatment is often difficult and time consuming, and can result in a deterioration in patient condition, or unsuitable therapy choices. A stable minimal model of the human cardiovascular system (CVS) is developed with the ultimate specific aim of assisting...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2003.10.001

    authors: Smith BW,Chase JG,Nokes RI,Shaw GM,Wake G

    更新日期:2004-03-01 00:00:00

  • The effects of flute shape and thread profile on the insertion torque and primary stability of dental implants.

    abstract::Easy insertion of the implant and stable bone purchase is essential for an ideal dental implantation. At the implant tip, the cutting flutes and conical profile are respectively designed to reduce insertion resistance and facilitate the initial insertion. However, the tapered tip might reduce the self-tapping and bone...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.021

    authors: Wu SW,Lee CC,Fu PY,Lin SC

    更新日期:2012-09-01 00:00:00

  • Validation of a C2-C7 cervical spine finite element model using specimen-specific flexibility data.

    abstract::This study presents a specimen-specific C2-C7 cervical spine finite element model that was developed using multiblock meshing techniques. The model was validated using in-house experimental flexibility data obtained from the cadaveric specimen used for mesh development. The C2-C7 specimen was subjected to pure continu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.03.001

    authors: Kallemeyn N,Gandhi A,Kode S,Shivanna K,Smucker J,Grosland N

    更新日期:2010-06-01 00:00:00

  • Fuzzy clustering of gait patterns of patients after ankle arthrodesis based on kinematic parameters.

    abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00020-0

    authors: Su F,Wu W,Cheng Y,Chou Y

    更新日期:2001-03-01 00:00:00

  • A non-invasive Cochlear Microphonic measurement system.

    abstract::The Cochlear Microphonic is one of the electrical potentials generated by the ear in response to audible stimuli. It is very difficult to measure the CM non-invasively because it has a very small magnitude (less than 1 μV). A high Common Mode Rejection Ratio (CMRR) and very large bandwidth (5 Hz-20 kHz) biomedical amp...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.017

    authors: Masood A,Teal PD,Hollitt C

    更新日期:2012-10-01 00:00:00

  • Numerical analysis and experimental observation of guidewire motion in a blood vessel model.

    abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.012

    authors: Takashima K,Tsuzuki S,Ooike A,Yoshinaka K,Yu K,Ohta M,Mori K

    更新日期:2014-12-01 00:00:00

  • Pilot study of a surgical robot system for zygomatic implant placement.

    abstract::Zygomatic implant technology has been regarded as an alternative treatment to massive grafting surgery in the severe atrophic maxillary. Nowadays, the assistant method with a real-time surgical navigation has been applied to reduce the risks of zygomatic implant placement. However, the accuracy of the complex operatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.020

    authors: Cao Z,Qin C,Fan S,Yu D,Wu Y,Qin J,Chen X

    更新日期:2020-01-01 00:00:00

  • Comparison of the bending performance of solid and cannulated spinal pedicle screws using finite element analyses and biomechanical tests.

    abstract::Spinal pedicle screw fixations have been used extensively to treat fracture, tumor, infection, or degeneration of the spine. Cannulated spinal pedicle screws with bone cement augmentation might be a useful method to ameliorate screw loosening. However, cannulated spinal pedicle screws might also increase the risk of s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.06.008

    authors: Shih KS,Hsu CC,Hou SM,Yu SC,Liaw CK

    更新日期:2015-09-01 00:00:00

  • Determination of the position and orientation of artificial knee implants using markers embedded in a bone: preliminary in vitro experiments.

    abstract::This study describes the method of determination of the position and orientation of artificial knee implants using a single-plane radiograph. To simplify the 3D/2D matching problem, we proposed to use small markers embedded in a bone. From the image coordinates of markers, it is possible to estimate the position and o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00037-7

    authors: Imai S,Higashijima K,Ishida A,Fukuoka Y,Hoshino A,Minamitani H

    更新日期:2003-06-01 00:00:00

  • Baseline drift removal and denoising of MCG data using EEMD: role of noise amplitude and the thresholding effect.

    abstract::We adopt the Ensemble Empirical Mode Decomposition (EEMD) method, with an appropriate thresholding on the Intrinsic Mode Functions (IMFs), to denoise the magnetocardiography (MCG) signal. To this end, we discuss the two associated problems that relate to: (i) the amplitude of noise added to the observed signal in the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.023

    authors: Mariyappa N,Sengottuvel S,Parasakthi C,Gireesan K,Janawadkar MP,Radhakrishnan TS,Sundar CS

    更新日期:2014-10-01 00:00:00

  • A method for determining the heat transfer and water vapour permeability of patient support systems.

    abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00003-5

    authors: Nicholson GP,Scales JT,Clark RP,de Calcina-Goff ML

    更新日期:1999-12-01 00:00:00

  • Application of soft tissue modelling to image-guided surgery.

    abstract::The deformation of soft tissue compromises the accuracy of image-guided surgery based on preoperative images, and restricts its applicability to surgery on or near bony structures. One way to overcome these limitations is to combine biomechanical models with sparse intraoperative data, in order to realistically warp t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2005.10.005

    authors: Carter TJ,Sermesant M,Cash DM,Barratt DC,Tanner C,Hawkes DJ

    更新日期:2005-12-01 00:00:00

  • Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects.

    abstract::Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and comple...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.015

    authors: Luo D,Rong Q,Chen Q

    更新日期:2017-09-01 00:00:00

  • Non-invasive identification of gastric contractions from surface electrogastrogram using back-propagation neural networks.

    abstract::Gastric contractions play an important role in the digestive process of the stomach. The established method for the measurement of gastric contractions is invasive and involves the insertion through the nose of a manometric probe into the stomach. A non-invasive method is introduced in this paper for the identificatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)95713-k

    authors: Chen JD,Lin Z,Wu Q,McCallum RW

    更新日期:1995-04-01 00:00:00

  • Combining ultrasonic and computed tomography scanning to characterize mechanical properties of cancellous bone in necrotic human femoral heads.

    abstract::Image-based finite element modelling has been commonly used to determine the biomechanical behaviours of human femora, particularly for the diagnosis of femoral head necrosis. One of the fundamental aspects of biomechanical modelling is the relationship between bone density, which is obtained from images, and elastic ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.02.002

    authors: Yue Y,Yang H,Li Y,Zhong H,Tang Q,Wang J,Wang R,He H,Chen W,Chen D

    更新日期:2019-04-01 00:00:00

  • Development of a home ankle exerciser.

    abstract::A portable, lightweight home ankle exerciser was designed and built by the Biomedical Engineering Department of University Hospital in London, Ontario, Canada. The ankle exerciser incorporates several unique features that overcomes the drawbacks of exercise equipment presently available. For optimal muscle strengtheni...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00057-7

    authors: Petrosenko RD,Vandervoort AA,Chesworth BM,Porter MM,Campbell GJ

    更新日期:1996-06-01 00:00:00

  • Compressive and tensile properties of articular cartilage in axial loading are modulated differently by osmotic environment.

    abstract::Aims of the present study were to test the hypotheses that (1) the compressive properties of articular cartilage are affected more by changes in the medium ionic concentration than the tensile properties, (2) collagen network controls the compression-tension nonlinearity of articular cartilage, and (3) proteoglycan (P...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.11.004

    authors: Korhonen RK,Jurvelin JS

    更新日期:2010-03-01 00:00:00

  • Pulse transit time in paediatric respiratory sleep studies.

    abstract::Pulse transit time (PTT) has emerged over the recent decades as a simple and non-invasive measure to quantify inspiratory effort changes in adults with sleep disordered breathing (SDB). Hence, this shows promise to be an effective screening tool for the paediatrics. However, little is known about its utility and suita...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2006.01.006

    authors: Foo JY

    更新日期:2007-01-01 00:00:00

  • fMRI brain mapping during motion capture and FES induced motor tasks: signal to noise ratio assessment.

    abstract::Functional Electrical Stimulation (FES) is a well known clinical rehabilitation procedure, however the neural mechanisms that underlie this treatment at Central Nervous System (CNS) level are still not completely understood. Functional magnetic resonance imaging (fMRI) is a suitable tool to investigate effects of reha...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.005

    authors: Gandolla M,Ferrante S,Casellato C,Ferrigno G,Molteni F,Martegani A,Frattini T,Pedrocchi A

    更新日期:2011-10-01 00:00:00

  • A portable monitoring system for measuring weight-bearing during tibial fracture healing.

    abstract::An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal par...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00061-7

    authors: Aranzulla PJ,Muckle DS,Cunningham JL

    更新日期:1998-10-01 00:00:00

  • New product development processes within the UK medical device industry.

    abstract::This paper reports on the findings of an extensive survey investigating practising design engineers' perceptions of new product development within the UK medical device industry. The design activity recorded was predominantly the small-scale development of low volume products. Explicit formal procedures were rarely us...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00021-5

    authors: Glen JM,Lord M

    更新日期:1996-12-01 00:00:00

  • Extended Central Tendency Measure and difference plot for heart rate variability analysis.

    abstract::Heart rate variability (HRV) is a non-invasive alternative to analyze the role of the autonomic nervous system (ANS) on heart functioning. Many tools have been developed to analyze collected cardiac data. Among them, the Central Tendency Measure (CTM) is a quantitative method for variability analysis of RR intervals. ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.024

    authors: Belfort RAU,Treccossi SPC,Silva JLF,Pillat VG,Freitas CBN,Dos Santos L

    更新日期:2019-12-01 00:00:00

  • Non-invasive approach towards the in vivo estimation of 3D inter-vertebral movements: methods and preliminary results.

    abstract::A kinematical model of the lower spine was designed and used to obtain a robust estimation of the vertebral rotations during torso movements from skin-surface markers recorded by video-cameras. Markers were placed in correspondence of the anatomical landmarks of the pelvic bone and vertebral spinous and transverse pro...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.08.005

    authors: Cerveri P,Pedotti A,Ferrigno G

    更新日期:2004-12-01 00:00:00

  • A biomechanical model to determine lumbosacral loads during single stance phase in normal gait.

    abstract::A dynamic biomechanical model to determine loads (joint forces) attained at the lumbosacral joint-centre during the stance phase of normal level walking was developed. The biomechanical model was based on rigid free body-segments; namely, the foot, shank, thigh, pelvis and head, arms and trunk (HAT) segments. In this ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)90374-k

    authors: Khoo BC,Goh JC,Bose K

    更新日期:1995-01-01 00:00:00

  • Characterization of crackles from patients with fibrosis, heart failure and pneumonia.

    abstract::The spectral analysis of crackles sounds has been carried out based on the assumption that they are stationary signals, and the majority of the work on the crackles was accomplished before the publication of the Computerized Respiratory Sound Analysis (CORSA) guidelines. This works characterizes crackles acquired from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.009

    authors: Ponte DF,Moraes R,Hizume DC,Alencar AM

    更新日期:2013-04-01 00:00:00

  • Pulse pressure waveform estimation using distension profiling with contactless optical probe.

    abstract::The pulse pressure waveform has, for long, been known as a fundamental biomedical signal and its analysis is recognized as a non-invasive, simple, and resourceful technique for the assessment of arterial vessels condition observed in several diseases. In the current paper, waveforms from non-invasive optical probe tha...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.014

    authors: Pereira T,Santos I,Oliveira T,Vaz P,Pereira T,Santos H,Pereira H,Correia C,Cardoso J

    更新日期:2014-11-01 00:00:00

  • Grasping soft tissue by means of vacuum technique.

    abstract:INTRODUCTION:A notable characteristic of bariatric surgery is the frequent manipulation of the bowel. The bowel is large, delicate, flexible, and has a natural lubricant on the tissue surface. Therefore the bowel is difficult to grasp and manipulate. Vacuum technique is commonly used in industry for all types of graspi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.014

    authors: Vonck D,Jakimowicz JJ,Lopuhaä HP,Goossens RH

    更新日期:2012-10-01 00:00:00