Abstract:
:An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal parameters associated with the patients' gait. This system was used to measure the weight-bearing achieved during the course of fracture healing in a small number of patients being treated by a variety of fixation methods for a tibial fracture. In general, weight-bearing was observed to increase with time post fracture, and the fixation method employed appeared to influence the rate of increase of loading of the fractured limb, more rigid methods of fixation enabling full-weight-bearing to be achieved sooner.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Aranzulla PJ,Muckle DS,Cunningham JLdoi
10.1016/s1350-4533(98)00061-7subject
Has Abstractpub_date
1998-10-01 00:00:00pages
543-8issue
7eissn
1350-4533issn
1873-4030pii
S1350453398000617journal_volume
20pub_type
杂志文章abstract::Understanding the load mechanics of orthopaedic implants is important to be able to predict their behaviour in-vivo. Much research, both mechanical and clinical, has been carried out on hip and knee implants, but less has been written about the mechanics of wrist implants. In this paper, the load mechanics of the Univ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.02.008
更新日期:2016-06-01 00:00:00
abstract::CT data has been widely used in the finite element modeling of bone. It can provide useful information on the geometrical topology and material properties of bone. Based on CT data, the assignment of bone material properties to finite element meshes is a fundamental step in the model generation. Most work done in this...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.06.003
更新日期:2006-04-01 00:00:00
abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.04.002
更新日期:2010-06-01 00:00:00
abstract:OBJECTIVE:Joint space narrowing is an important feature of progressive joint damage and functional impairment in rheumatoid arthritis (RA). Methods to provide a continuous measurement of joint space width have not been adopted in research or clinical settings. High-resolution peripheral quantitative computed tomography...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.04.003
更新日期:2013-10-01 00:00:00
abstract::Small spaces make collision-free turns difficult for wheelchair users. Contrary to basic kinematic wheelchair modelling and not considered previously by engineers; when wheelchairs turn in small spaces, could lateral drift (sideways slipping) increase the risk of collisions with surrounding structures such as walls an...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.11.012
更新日期:2021-01-01 00:00:00
abstract::Subject-specific FE-models of human long bones have to predict mechanical parameters with sufficient accuracy to be applicable in a clinical setting. One of the main aspects in subject-specific FE-models of bones regarding accuracy is the modeling of the material inhomogeneity. The goal of this study was therefore to ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.08.022
更新日期:2013-07-01 00:00:00
abstract::Neointimal hyperplasia (NIH) is a major obstacle to graft patency in the peripheral arteries. A complex interaction of biomechanical factors contribute to NIH development and progression, and although haemodynamic markers such as wall shear stress have been linked to the disease, these have so far been insufficient to...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.09.011
更新日期:2019-12-01 00:00:00
abstract::The purpose of this study is to demonstrate a new MRI compatible loading device capable of reconstructing realistic loading scenarios of the human foot for research in the field of foot biomechanics. This device has two different configurations: one used to compress the forefoot and one to bend the metatarsophalangeal...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.06.006
更新日期:2014-09-01 00:00:00
abstract::Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). Th...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.05.002
更新日期:2016-09-01 00:00:00
abstract::The aim of this study was to evaluate comparatively five methods for automating mesh generation (AMG) when used to mesh a human femur. The five AMG methods considered were: mapped mesh, which provides hexahedral elements through a direct mapping of the element onto the geometry; tetra mesh, which generates tetrahedral...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(97)00049-0
更新日期:1998-01-01 00:00:00
abstract::Sclerosis rim surrounding the necrotic area is commonly found in necrotic femoral head, but the biomechanical function of sclerosis rim has received relatively little attention. Little is known about the formation and natural history of sclerosis rim. In the present work, we assume that the necrotic change may trigger...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.09.005
更新日期:2015-12-01 00:00:00
abstract::To study the aetiology of pressure ulcers an MR-compatible loading device was developed. Magnetic resonance imaging provides the possibility of non-invasive evaluation of muscle tissue after compressive loading. Pressure was applied to the tibialis anterior region of rats by means of an indenter. The developed MR-comp...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.07.005
更新日期:2006-05-01 00:00:00
abstract::A three-layer artificial neural network was used for adaptive control of gait swing generated by neuromuscular electrical stimulation (NMES) in a spinal cord injured subject. Network inputs consisted of knee and ankle goniometer signals for System 1, and knee and hip angular data for System 2. Controller output was pr...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00030-6
更新日期:1997-01-01 00:00:00
abstract::Segmentation of medical images is very important for clinical research and diagnosis, leading to a requirement for robust automatic methods. This paper reports on the combined use of a neural network (a multilayer perceptron, MLP) and active contour model ('snake') to segment structures in magnetic resonance (MR) imag...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/s1350-4533(03)00137-1
更新日期:2004-01-01 00:00:00
abstract::The impeller blood pump with its simplicity has many advantages compared with the diaphragm pump, but the nonpulsatile property has limited its applications. To make the impeller pump pulsatile, many investigations have been made in vain because of resulting haemolysis. The author has succeeded in producing a pulsatil...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00010-0
更新日期:1996-01-01 00:00:00
abstract::The liquid ventilation (LV) technique was previously demonstrated to be a valuable alternative to ordinary gas ventilation, particularly for newborn patients with severely distressed lungs. This work describes a mathematical model of gas transfer phenomena occurring within the lungs of a preterm newborn baby ventilate...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00041-0
更新日期:1997-03-01 00:00:00
abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.12.003
更新日期:2016-03-01 00:00:00
abstract::This paper describes a non-invasive human brain-actuated robotic arm experiment, which allows remote writing. In the local environment, the participant decides on an arbitrary word to transmit. A mental speller interface is then used to select the letters. A robot arm placed in the remote environment writes the word o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.06.005
更新日期:2011-12-01 00:00:00
abstract::Clinical studies show that non-invasive respiratory support by continuous positive airway pressure (CPAP) affects gas conditioning in the upper airways, especially in the presence of mouth leaks. Using a new bench model of neonatal CPAP, we investigated the influence of mouth opening on oropharyngeal temperature and h...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.12.005
更新日期:2017-02-01 00:00:00
abstract::Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and comple...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.06.015
更新日期:2017-09-01 00:00:00
abstract::This study presents a theoretical model of the general stress state found in helical implantable leads in bending. The model accurately predicts stress in large filarity coils made from clad wire. The stress is predicted using flexural rigidity of the coil and is developed to include the effects of coil pitch and the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00022-7
更新日期:1997-10-01 00:00:00
abstract::The standard camera- and force plate-based set-up for motion analysis suffers from the disadvantage of being limited to laboratory settings. Since adaptive algorithms are able to learn the connection between known inputs and outputs and generalise this knowledge to unknown data, these algorithms can be used to leverag...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.10.001
更新日期:2020-12-01 00:00:00
abstract::The prerequisite for the continuous in vivo monitoring of glucose concentration is the development of an implantable glucose sensor with long-term stability. A new enzyme electrode concept featuring fluid-state glucose oxidase modified carbon powder along with a cross-linked glucose oxidase enzyme layer has been devel...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(90)90008-v
更新日期:1994-09-01 00:00:00
abstract::A method for assessment and second-order polynomial detrending of signals containing periodic components is proposed. The analytically derived properties of this method are validated with synthesized signals, processed by the computational procedure developed. It is shown that, in addition to accurate detrending, the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00077-0
更新日期:1998-11-01 00:00:00
abstract::A novel method to evaluate postural sway is presented: balance strategies are identified by applying a markerless image processing algorithm to video sequences obtained from commercially available systems. The motion estimation technique for the analysis of video sequences is a coarse to fine procedure based on the bl...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.10.007
更新日期:2006-09-01 00:00:00
abstract::Some pulmonary diseases and injuries are believed to correlate with lung viscoelasticity changes. Hence, a better understanding of lung viscoelastic models could provide new perspectives on the progression of lung pathology and trauma. In the presented study, stress relaxation measurements were performed to quantify r...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.05.003
更新日期:2015-08-01 00:00:00
abstract::The results from studies of wave propagation in large arteries carried out over the last 25 years have shown that there is a good agreement among values of the imaginary part of the complex propagation coefficient, as expressed by pressure or flow-rate wave propagation velocity. However, there is considerable disparit...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00073-2
更新日期:1997-04-01 00:00:00
abstract::This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) co...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.05.007
更新日期:2010-10-01 00:00:00
abstract::A few finite element models have addressed the dynamic juxtaarticular stress transmission but none focused the investigation on the combined influence of the individual moduli of the underlying bones, including the subchondral plate, the femoral head and the femoral neck of the proximal femur. A finite element model i...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.12.008
更新日期:2005-05-01 00:00:00
abstract::During fatiguing contractions, many adjustments in motor units behaviour occur: decrease in muscle fibre conduction velocity; increase in motor units synchronisation; modulation of motor units firing rate; increase in variability of motor units inter-spike interval. We simulated the influence of all these adjustments ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.09.022
更新日期:2016-12-01 00:00:00