Abstract:
:A three-layer artificial neural network was used for adaptive control of gait swing generated by neuromuscular electrical stimulation (NMES) in a spinal cord injured subject. Network inputs consisted of knee and ankle goniometer signals for System 1, and knee and hip angular data for System 2. Controller output was proportional to changes in applied NMES pulse width (PW). Stimulation was applied to the left femoral and common peroneal nerves. The neural networks were trained off-line and on-line. Network performance was assessed by applying a number of different stimulation PWs and later comparing the resulting motion to a sample good step observed during the same test session. On-line training consisted of negative and positive reinforcement applied at chosen times. Both on-line and off-line training algorithms consisted of an enhanced supervised backpropagation scheme. Performance evaluation results favour the use of System 1 over System 2. Also, a network trained off-line and later submitted to on-line punishment appears to be more reliable (in automatic mode) than the same network after it is submitted to on-line reward or to off-line training alone. Finally, the systems' immediate response to on-line learning was favourable in all cases. Based on the results, a version of System 1 was used to generate walking in the test subject. This test indicated that the system is promising.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Sepulveda F,Granat MH,Cliquet A Jrdoi
10.1016/s1350-4533(96)00030-6subject
Has Abstractpub_date
1997-01-01 00:00:00pages
21-8issue
1eissn
1350-4533issn
1873-4030pii
S1350453396000306journal_volume
19pub_type
杂志文章abstract::A method for assessment and second-order polynomial detrending of signals containing periodic components is proposed. The analytically derived properties of this method are validated with synthesized signals, processed by the computational procedure developed. It is shown that, in addition to accurate detrending, the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(98)00077-0
更新日期:1998-11-01 00:00:00
abstract::We have developed a method that allows biological tissues to be adhered together with minimal invasion by delivering integrated low-level energies from heat, pressure, and vibration. Tensile tests on adhered slices of porcine aorta were performed to determine the relationships between adhesive strength and conditions ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.12.005
更新日期:2010-05-01 00:00:00
abstract::The thermal conductivity of cortical bone was characterized experimentally. Specimens were taken from the mid-diaphysis of bovine femora, and the rate of heat transfer was measured in three orthogonal directions. The conductivity was found to be 0.58+/-0.018 W/mK in the longitudinal direction, 0.53+/-0.030 W/mK in the...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00003-0
更新日期:2000-12-01 00:00:00
abstract::Fitts' Law was extended in the polar coordinate system, and a set of indices for human motion evaluation is proposed. In this paper, the index of difficulty and the index of performance are introduced as the general indices for the quality measure of plane target-to-target movement. As an example, the target-reaching ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(01)00121-7
更新日期:2002-03-01 00:00:00
abstract::In the fields of medicine and biomechanics, MEMS accelerometers are increasingly used to perform activity recognition by directly measuring acceleration; to calculate speed and position by numerical integration of the signal; or to estimate the orientation of body parts in combination with gyroscopes. For some of thes...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2016.08.004
更新日期:2016-11-01 00:00:00
abstract::Bone-attached robots and microstereotactic frames, intended for deep brain stimulation and minimally invasive cochlear implantation, typically attach to a patient's skull via bone anchors. A rigid and reliable link between such devices and the skull is mandatory in order to fulfill the high accuracy demands of minimal...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.02.012
更新日期:2015-05-01 00:00:00
abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2015.12.003
更新日期:2016-03-01 00:00:00
abstract::This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) co...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.05.007
更新日期:2010-10-01 00:00:00
abstract::Human-administered clinical scales are commonly used for quantifying motor performance and determining the course of therapy in post-stroke individuals. Computerized methods aim to improve consistency, resolution and duration of patients' evaluation. The objective of this study was to test the validity of computerized...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.06.001
更新日期:2019-09-01 00:00:00
abstract::Precise evaluation of graft reperfusion is difficult in clinical liver transplantation. The oxygen electrode (OE) is a novel technique to detect blood flow indirectly by measuring the quantity of oxygen which can diffuse from the hepatic tissue to the surface electrode. Application of the surface OE does not influence...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(00)00060-6
更新日期:2000-06-01 00:00:00
abstract::The interaction of electromagnetic fields with the human body is quantified by the dielectric properties of biological tissues. These properties are incorporated into complex numerical simulations using parametric models such as Debye and Cole-Cole, for the computational investigation of electromagnetic wave propagati...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.01.017
更新日期:2017-05-01 00:00:00
abstract::In this study, a new ensemble averaging technique was developed to measure cardiac output during treadmill exercise. Each dz/dt peak is used as a starting point for ensemble averaging, instead of the conventionally used R point of ECG, in order to prevent the peak dz/dt waveform (C point) to be smoothed, which results...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/s1350-4533(03)00024-9
更新日期:2003-07-01 00:00:00
abstract::Complications arising from limb-lengthening procedures such as muscle contracture, axial malalignment of the bone and traction injuries to the nerves and vessels, are often severe. Often complications arise from the build-up of forces in the biological tissues which are resisting lengthening. Little is known about the...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/s1350-4533(97)00010-6
更新日期:1997-07-01 00:00:00
abstract::In vivo bone behaviour predictions with respect to altered loading conditions, implants, and endoprostheses are highly desirable to avoid untoward effects such as implant loosening and breakage. This knowledge does not relate only to the result but also to the mechanisms of bone adaptation and bone growth. Since bone ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(94)90014-0
更新日期:1994-01-01 00:00:00
abstract::Beat detection is a basic and fundamental step in electrocardiogram (ECG) processing. In many ECG applications strong artifacts from biological or technical sources could appear and cause distortion of ECG signals. Beat detection algorithm desired property is to avoid these distortions and detect beats in any situatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.07.017
更新日期:2013-06-01 00:00:00
abstract::Neointimal hyperplasia (NIH) is a major obstacle to graft patency in the peripheral arteries. A complex interaction of biomechanical factors contribute to NIH development and progression, and although haemodynamic markers such as wall shear stress have been linked to the disease, these have so far been insufficient to...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.09.011
更新日期:2019-12-01 00:00:00
abstract::Image-based finite element modelling has been commonly used to determine the biomechanical behaviours of human femora, particularly for the diagnosis of femoral head necrosis. One of the fundamental aspects of biomechanical modelling is the relationship between bone density, which is obtained from images, and elastic ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.02.002
更新日期:2019-04-01 00:00:00
abstract::This study presents a novel method for the detection and classification of a wide range of physical activities, including standing, sitting, lying, level walking, and walking upstairs and downstairs using a single chest-mounted accelerometer. The trunk inclination angle and variation of the gravitational component of ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2018.04.008
更新日期:2018-07-01 00:00:00
abstract::Apparatus has been built to explore the practical feasibility of using automatic control with electrical stimulation of paralysed legs to restore function. The experiments are performed with paraplegics with the aim of achieving a realistic postural task: to see whether the body may be maintained upright by stimulatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(97)00020-9
更新日期:1997-09-01 00:00:00
abstract::Budd-Chiari syndrome (BCS) is a rare liver disease characterised by the obstruction of draining hepatic veins, and subsequent reduced blood return to the heart. Although many clinical BCS studies have been reported, few studies have quantified the associated changes that occur in the entire hepatic circulation. In thi...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.04.010
更新日期:2019-07-01 00:00:00
abstract::A dynamic biomechanical model to determine loads (joint forces) attained at the lumbosacral joint-centre during the stance phase of normal level walking was developed. The biomechanical model was based on rigid free body-segments; namely, the foot, shank, thigh, pelvis and head, arms and trunk (HAT) segments. In this ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)90374-k
更新日期:1995-01-01 00:00:00
abstract::Aims of the present study were to test the hypotheses that (1) the compressive properties of articular cartilage are affected more by changes in the medium ionic concentration than the tensile properties, (2) collagen network controls the compression-tension nonlinearity of articular cartilage, and (3) proteoglycan (P...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.11.004
更新日期:2010-03-01 00:00:00
abstract::Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing stead...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.02.008
更新日期:2019-04-01 00:00:00
abstract::There is an increasing awareness among the populace of the need for regular health check-up to detect diseases in their early stages and thereby administer treatments in a timely fashion. However, commercially available physiological signal monitoring devices, which may offer clues on the onset of diseases, are time-c...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.04.011
更新日期:2013-02-01 00:00:00
abstract::In contrast enhanced magnetic resonance imaging (MRI) and computed tomography (CT), the equilibrium distribution of anionic contrast agent is expected to reflect the fixed charged density (FCD) of articular cartilage. Diffusion is mainly responsible for the transport of contrast agents into cartilage. In osteoarthriti...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.06.002
更新日期:2010-10-01 00:00:00
abstract::Clinical studies show that non-invasive respiratory support by continuous positive airway pressure (CPAP) affects gas conditioning in the upper airways, especially in the presence of mouth leaks. Using a new bench model of neonatal CPAP, we investigated the influence of mouth opening on oropharyngeal temperature and h...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.12.005
更新日期:2017-02-01 00:00:00
abstract::To better understand the mechanisms underlying distal radius fracture we have developed finite element models to predict radius bone strain and fracture strength under loading conditions simulating a fall. This study compares experimental surface strains and fracture loads of the distal radius with specimen-specific f...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.07.016
更新日期:2012-04-01 00:00:00
abstract::A model of the lumbar spine, pelvis and buttocks is developed, based on linear horizontal and vertical systems along with a rotational subsystem. The model can mimic qualitatively different experimental observations of transmission of vibrations from the seat to L3 in the sitting posture. It is concluded that while th...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00062-3
更新日期:1996-07-01 00:00:00
abstract::Gastric contractions play an important role in the digestive process of the stomach. The established method for the measurement of gastric contractions is invasive and involves the insertion through the nose of a manometric probe into the stomach. A non-invasive method is introduced in this paper for the identificatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)95713-k
更新日期:1995-04-01 00:00:00
abstract::The spectral local F-test has been applied for detecting evoked responses to rhythmic stimulation that are embedded in the ongoing electroencephalogram (EEG). Based on the sampling distribution of a flat spectrum at the neighbourhood of the stimulation frequency, spectral peaks in an EEG signal that are due to the sti...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2017.06.032
更新日期:2017-10-01 00:00:00