A mathematical model of the impact response of the seated subject.

Abstract:

:A model of the lumbar spine, pelvis and buttocks is developed, based on linear horizontal and vertical systems along with a rotational subsystem. The model can mimic qualitatively different experimental observations of transmission of vibrations from the seat to L3 in the sitting posture. It is concluded that while the model lacks detailed sophistication, it adds to our qualitative understanding of the biomechanics of seated vibrations by pointing to those subsystems responsible for the observed transfer functions.

journal_name

Med Eng Phys

authors

Broman H,Pope M,Hansson T

doi

10.1016/1350-4533(95)00062-3

subject

Has Abstract

pub_date

1996-07-01 00:00:00

pages

410-9

issue

5

eissn

1350-4533

issn

1873-4030

pii

1350453395000623

journal_volume

18

pub_type

杂志文章
  • Pre-surgical CT/FEA for craniofacial distraction: I. Methodology, development, and validation of the cranial finite element model.

    abstract::Recently, surgeons have begun to treat serious congenital craniofacial deformities including craniosynostoses with mechanical devices that gradually distract the skull. As a prospective means of treatment planning for such complex deformities, FE models derived from routine preoperative CT scans (CT/FEA) would provide...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00053-8

    authors: Remmler D,Olson L,Ekstrom R,Duke D,Matamoros A,Matthews D,Ullrich CG

    更新日期:1998-11-01 00:00:00

  • Multispectral classification techniques for terahertz pulsed imaging: an example in histopathology.

    abstract::Terahertz pulsed imaging is a spectroscopic imaging modality using pulses of electromagnetic radiation (100 GHz-10 THz), and there has been recent interest in studying biomedical specimens. It is usual to display parametric images derived from the measured pulses. In this work, classification was achieved by applying ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.02.011

    authors: Berry E,Handley JW,Fitzgerald AJ,Merchant WJ,Boyle RD,Zinov'ev NN,Miles RE,Chamberlain JM,Smith MA

    更新日期:2004-06-01 00:00:00

  • Smartphone application for emergency signal detection.

    abstract::Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). Th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.002

    authors: Figueiredo IN,Leal C,Pinto L,Bolito J,Lemos A

    更新日期:2016-09-01 00:00:00

  • Biomechanical analysis using FEA and experiments of a standard plate method versus three cable methods for fixing acetabular fractures with simultaneous THA.

    abstract::Acetabular fractures potentially account for up to half of all pelvic fractures, while pelvic fractures potentially account for over one-tenth of all human bone fractures. This is the first biomechanical study to assess acetabular fracture fixation using plates versus cables in the presence of a total hip arthroplasty...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.004

    authors: Aziz MSR,Dessouki O,Samiezadeh S,Bougherara H,Schemitsch EH,Zdero R

    更新日期:2017-08-01 00:00:00

  • Motion quality evaluation of upper limb target-reaching movements.

    abstract::Fitts' Law was extended in the polar coordinate system, and a set of indices for human motion evaluation is proposed. In this paper, the index of difficulty and the index of performance are introduced as the general indices for the quality measure of plane target-to-target movement. As an example, the target-reaching ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00121-7

    authors: Yang N,Zhang M,Huang C,Jin D

    更新日期:2002-03-01 00:00:00

  • Reliability, validity, and precision of an active stereophotogrammetry system for three-dimensional evaluation of the human torso.

    abstract::To determine the reliability, stability, validity and precision of a stereophotogrammetry (SP) system for use in quantifying the complex three-dimensional structure of the human torso, we performed assessments of the system using images of geometric solids and a human-form mannequin. Analysis of geometric solids revea...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.011

    authors: Paul SM,Chamberlin AP,Hatt C,Nayak AV,Danoff JV

    更新日期:2009-12-01 00:00:00

  • Model-based physiomarkers of cerebral hemodynamics in patients with mild cognitive impairment.

    abstract::In our previous studies, we have introduced model-based "functional biomarkers" or "physiomarkers" of cerebral hemodynamics that hold promise for improved diagnosis of early-stage Alzheimer's disease (AD). The advocated methodology utilizes subject-specific data-based dynamic nonlinear models of cerebral hemodynamics ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.025

    authors: Marmarelis VZ,Shin DC,Orme ME,Zhang R

    更新日期:2014-05-01 00:00:00

  • Reconstruction of proximal humeral fractures with a reduced number of screws and a reinforced bone substitute.

    abstract::Multi-fragmented fractures of the proximal humerus are difficult to treat, especially in the case of osteoporotic bone. Intra-operative risks include cartilage damage when inserting multiple screws. A common post-operative complication is distal-varus collapse of the head. The aim of this study was to investigate if a...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.06.002

    authors: Cristofolini L,Morellato K,Cavallo M,Guerra E

    更新日期:2020-08-01 00:00:00

  • Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: a comparison of six different state-of-the-art meshes.

    abstract:BACKGROUND:An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. METHOD...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.022

    authors: Konerding MA,Chantereau P,Delventhal V,Holste JL,Ackermann M

    更新日期:2012-09-01 00:00:00

  • Construction, in vitro and in vivo evaluation of an in-house conductance meter for measurement of skin hydration.

    abstract::Different probes are used in dermato-cosmetic research to measure the electrical properties of the skin. The principle governing the choice of the geometry and material of the measuring probe is not well defined in the literature and some device's measuring principles are not accessible for the scientific community. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.02.008

    authors: Hamed SH,Altrabsheh B,Assa'd T,Jaradat S,Alshra'ah M,Aljamal A,Alkhatib HS,Almalty AM

    更新日期:2012-12-01 00:00:00

  • Implementation of a PC-based integrated control system for children.

    abstract::Children with severe physical disabilities often require a range of technological devices to aid them with the fundamental tasks carried out in everyday life. These tasks areas may include mobility, communication, environment control and computer access for education. The most efficient, and often the most cost-effect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90043-4

    authors: Hawley MS,Cudd PA,Cherry AD

    更新日期:1994-05-01 00:00:00

  • The effect of compressive deformations on the rate of build-up of oxygen in isolated skeletal muscle cells.

    abstract::In this study we integrated between confocal-based cell-specific finite element (FE) modeling and Virtual Cell (VC) transport simulations in order to determine trends of relationship between externally applied compressive deformations and build-up rates of oxygen in myoblast cells, and to further test how mild culture...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.008

    authors: Leopold E,Sopher R,Gefen A

    更新日期:2011-11-01 00:00:00

  • Linear and nonlinear analyses of multi-channel mechanomyographic recordings reveal heterogeneous activation of wrist extensors in presence of delayed onset muscle soreness.

    abstract::In this study, we applied multi-channel mechanomyographic (MMG) recordings in combination with linear and nonlinear analyses to investigate muscular and musculotendinous effects of high intensity eccentric exercise. Twelve accelerometers arranged in a 3 × 4 matrix over the dominant elbow muscles were used to detect MM...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.003

    authors: Madeleine P,Hansen EA,Samani A

    更新日期:2014-12-01 00:00:00

  • Genetic fuzzy modelling and control of bispectral index (BIS) for general intravenous anaesthesia.

    abstract::Based on an adaptive genetic fuzzy clustering algorithm, a derived fuzzy knowledge model is proposed for quantitatively estimating the systolic arterial pressure (SAP), heart rate (HR), and bispectral index (BIS) using 12 patients and it validates them according to pharmacological reasoning. Also, a genetic proportion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.medengphy.2005.04.023

    authors: Shieh JS,Kao MH,Liu CC

    更新日期:2006-03-01 00:00:00

  • A method for determining the heat transfer and water vapour permeability of patient support systems.

    abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00003-5

    authors: Nicholson GP,Scales JT,Clark RP,de Calcina-Goff ML

    更新日期:1999-12-01 00:00:00

  • The influence of mechanical properties of subchondral plate, femoral head and neck on dynamic stress distribution of the articular cartilage.

    abstract::A few finite element models have addressed the dynamic juxtaarticular stress transmission but none focused the investigation on the combined influence of the individual moduli of the underlying bones, including the subchondral plate, the femoral head and the femoral neck of the proximal femur. A finite element model i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.12.008

    authors: Wei HW,Sun SS,Jao SH,Yeh CR,Cheng CK

    更新日期:2005-05-01 00:00:00

  • An automated ECG-artifact removal method for trunk muscle surface EMG recordings.

    abstract::This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) co...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.05.007

    authors: Mak JN,Hu Y,Luk KD

    更新日期:2010-10-01 00:00:00

  • The Windkessel model revisited: a qualitative analysis of the circulatory system.

    abstract::In this paper, we derive a comprehensive computational model to estimate the arterial pressure and the cardiac output of humans, by refining and adapting the well-established equations of the Windkessel theory. The model inputs are based on patient specific factors such as age, sex, smoking and fitness habits as well ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.11.010

    authors: Tsanas A,Goulermas JY,Vartela V,Tsiapras D,Theodorakis G,Fisher AC,Sfirakis P

    更新日期:2009-06-01 00:00:00

  • A non-invasive Cochlear Microphonic measurement system.

    abstract::The Cochlear Microphonic is one of the electrical potentials generated by the ear in response to audible stimuli. It is very difficult to measure the CM non-invasively because it has a very small magnitude (less than 1 μV). A high Common Mode Rejection Ratio (CMRR) and very large bandwidth (5 Hz-20 kHz) biomedical amp...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.017

    authors: Masood A,Teal PD,Hollitt C

    更新日期:2012-10-01 00:00:00

  • Micro-CT evaluation of bone defects: applications to osteolytic bone metastases, bone cysts, and fracture.

    abstract::Bone defects can occur in various forms and present challenges to performing a standard micro-CT evaluation of bone quality because most measures are suited to homogeneous structures rather than ones with spatially focal abnormalities. Such defects are commonly associated with pain and fragility. Research involving bo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.016

    authors: Buie HR,Bosma NA,Downey CM,Jirik FR,Boyd SK

    更新日期:2013-11-01 00:00:00

  • Enabling variable-stiffness hand rehabilitation orthoses with dielectric elastomer transducers.

    abstract::Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.10.015

    authors: Carpi F,Frediani G,Gerboni C,Gemignani J,De Rossi D

    更新日期:2014-02-01 00:00:00

  • Biomechanical analysis of combining head-down tilt traction with vibration for different grades of degeneration of the lumbar spine.

    abstract::In recent years, a combination of traction and vibration therapy is usually used to alleviate low back pain (LBP) in clinical settings. Combining head-down tilt (HDT) traction with vibration was demonstrated to be efficacious for LBP patients in our previous study. However, the biomechanics of the lumbar spine during ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.004

    authors: Wang S,Wang L,Wang Y,Du C,Zhang M,Fan Y

    更新日期:2017-01-01 00:00:00

  • The effect of the subcutaneous fat on the transfer of current through skin and into muscle.

    abstract::The present investigation was conducted to see the effect of subcutaneous fat on the transmission characteristics of an electrical stimulus applied to the skin and conducted to skeletal muscle. Two groups of subjects participated. In one, the subjects were three males and three females whose average age was 24.6+/-1.5...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.02.009

    authors: Petrofsky J

    更新日期:2008-11-01 00:00:00

  • The kinetic model and simulation of blood coagulation--the kinetic influence of activated protein C.

    abstract::The paper described a limited part of the coagulation pathway, and in particular the inhibitory effects of activated protein C in the context of thrombin production. This is a computational modeling study with various assumption made of kinetic rates laws and their summation. The level of complexity and assumed parame...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.01.003

    authors: Qiao YH,Xu CQ,Zeng YJ,Xu XH,Zhao H,Xu H

    更新日期:2004-05-01 00:00:00

  • Gabor frames for classification of paroxysmal and persistent atrial fibrillation episodes.

    abstract::In this study, we propose a new classification method for early differentiation of paroxysmal and persistent atrial fibrillation episodes, i.e. those which spontaneously or with external intervention will return to sinus rhythm within 7 days of onset from the ones where the arrhythmia is sustained for more than 7 days...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.013

    authors: Ortigosa N,Galbis A,Fernández C,Cano Ó

    更新日期:2017-01-01 00:00:00

  • Assessment of the initial viscoelastic properties of a critical segmental long bone defect reconstructed with impaction bone grafting and intramedullary nailing.

    abstract:INTRODUCTION:This study compared the initial viscoelastic properties of a segmental tibial defect stabilized with intramedullary nailing and impaction bone grafting to that of a transverse fracture stabilized with intramedullary nailing. MATERIALS AND METHODS:Seven sheep tibiae were tested in compression (1000N), bend...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.003

    authors: Costi JJ,Stanley RM,Ding B,Solomon LB

    更新日期:2014-01-01 00:00:00

  • Comparison of different methods for the determination of the true wave propagation coefficient, in rubber tubes and the canine thoracic aorta.

    abstract::The results from studies of wave propagation in large arteries carried out over the last 25 years have shown that there is a good agreement among values of the imaginary part of the complex propagation coefficient, as expressed by pressure or flow-rate wave propagation velocity. However, there is considerable disparit...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00073-2

    authors: Bertram CD,Gow BS,Greenwald SE

    更新日期:1997-04-01 00:00:00

  • Determination of the position and orientation of artificial knee implants using markers embedded in a bone: preliminary in vitro experiments.

    abstract::This study describes the method of determination of the position and orientation of artificial knee implants using a single-plane radiograph. To simplify the 3D/2D matching problem, we proposed to use small markers embedded in a bone. From the image coordinates of markers, it is possible to estimate the position and o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00037-7

    authors: Imai S,Higashijima K,Ishida A,Fukuoka Y,Hoshino A,Minamitani H

    更新日期:2003-06-01 00:00:00

  • Identification of lower arm motions using the EMG signals of shoulder muscles.

    abstract::This investigation explored pattern recognition of EMG signals produced by shoulder area muscles to identify the performance of a select number of lower arm motions. The signals were modelled as fourth-order autoregressive processes with the parameters of the models used to classify the different motions. The recorded...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90024-8

    authors: Latwesen A,Patterson PE

    更新日期:1994-03-01 00:00:00

  • A biased competition based neurodynamical model of visual neglect.

    abstract::On the computational basis of a neurodynamical cortical model, we investigate a specific top-down visual cognitive impairment in brain-damaged patients known as visual spatial neglect. The computational cortical model accounts the neurodynamics underlying selective visual attention, is based on the "biased competition...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2004.06.011

    authors: Deco G,Zihl J

    更新日期:2004-11-01 00:00:00