Biomechanical analysis of combining head-down tilt traction with vibration for different grades of degeneration of the lumbar spine.

Abstract:

:In recent years, a combination of traction and vibration therapy is usually used to alleviate low back pain (LBP) in clinical settings. Combining head-down tilt (HDT) traction with vibration was demonstrated to be efficacious for LBP patients in our previous study. However, the biomechanics of the lumbar spine during this combined treatment is not well known and need quantitative analysis. In addition, LBP patients have different grades of degeneration of the lumbar spinal structure, which are often age related. Selecting a suitable rehabilitation therapy for different age groups of patients has been challenging. Therefore, a finite element (FE) model of the L1-L5 lumbar spine and a vibration dynamic model are developed in this study in order to investigate the biomechanical effects of the combination of HDT traction and vibration therapy on the age-related degeneration of the lumbar spine. The decrease of intradiscal pressure is more effective when vibration is combined with traction therapy. Moreover, the stresses on the discs are lower in the "traction+vibration" mode than the "traction-only" mode. The stress concentration at the posterior part of nucleus is mitigated after the vibration is combined. The disc deformations especially posterior disc radial retraction is improved in the "traction+vibration" mode. These beneficial effects of this therapy could help decompress the discs and spinal nerves and therefore relieve LBP. Simultaneously, patients with grade 1 degeneration (approximately 41-50 years old) are able to achieve better results compared with other age groups. This study could be used to provide a more effective LBP rehabilitation therapy.

journal_name

Med Eng Phys

authors

Wang S,Wang L,Wang Y,Du C,Zhang M,Fan Y

doi

10.1016/j.medengphy.2016.10.004

subject

Has Abstract

pub_date

2017-01-01 00:00:00

pages

83-93

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(16)30250-8

journal_volume

39

pub_type

杂志文章
  • Grasping soft tissue by means of vacuum technique.

    abstract:INTRODUCTION:A notable characteristic of bariatric surgery is the frequent manipulation of the bowel. The bowel is large, delicate, flexible, and has a natural lubricant on the tissue surface. Therefore the bowel is difficult to grasp and manipulate. Vacuum technique is commonly used in industry for all types of graspi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.014

    authors: Vonck D,Jakimowicz JJ,Lopuhaä HP,Goossens RH

    更新日期:2012-10-01 00:00:00

  • Effect of different inertial parameter sets on joint moment calculation during stair ascending and descending.

    abstract::The reliability of internal joint moment calculation in gait analysis during daily living activities is fundamental for clinical decisions based on joint function. This calculation, obtained by means of the inverse dynamics, depends on several modelling factors, such as assumptions on the segments and on the relevant ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.12.002

    authors: Fantozzi S,Stagni R,Cappello A,Leardini A

    更新日期:2005-07-01 00:00:00

  • A novel integrated mechanomyogram-vocalization access solution.

    abstract::We introduce a novel dual-switch control paradigm based on the simultaneous measurement of frontalis muscle mechanomyography (MMG) and vocalizations (humming) using a single contact microphone attached to the forehead. Vibrations of the face and skull during vocalization are manifested as periodic high-frequency compo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.06.003

    authors: Alves N,Falk TH,Chau T

    更新日期:2010-10-01 00:00:00

  • Comparison of algorithms to quantify muscle fatigue in upper limb muscles based on sEMG signals.

    abstract::This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.009

    authors: Kahl L,Hofmann UG

    更新日期:2016-11-01 00:00:00

  • Real time monitoring of muscular fatigue from dynamic surface myoelectric signals using a complex covariance approach.

    abstract::A method aimed at the real-time monitoring of muscular fatigue was implemented and optimized. The method is based on an estimate of the complex covariance function in order to evaluate, in real time, the mean frequency of the myoelectric signal spectrum. Real-time implementation is guaranteed by a recursive computatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00049-1

    authors: Conforto S,D'Alessio T

    更新日期:1999-05-01 00:00:00

  • Separation of electrocardiographic from electromyographic signals using dynamic filtration.

    abstract::Trunk muscle electromyographic (EMG) signals are often contaminated by the electrical activity of the heart. During low or moderate muscle force, these electrocardiographic (ECG) signals disturb the estimation of muscle activity. Butterworth high-pass filters with cut-off frequency of up to 60 Hz are often used to sup...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.04.007

    authors: Christov I,Raikova R,Angelova S

    更新日期:2018-07-01 00:00:00

  • Mechanical testing and modelling of the Universal 2 implant.

    abstract::Understanding the load mechanics of orthopaedic implants is important to be able to predict their behaviour in-vivo. Much research, both mechanical and clinical, has been carried out on hip and knee implants, but less has been written about the mechanics of wrist implants. In this paper, the load mechanics of the Univ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.008

    authors: Gislason MK,Foster E,Main D,Fusiek G,Niewczas P,Bransby-Zachary M,Nash DH

    更新日期:2016-06-01 00:00:00

  • Penetration of an artificial arterial thromboembolism in a live animal using an intravascular therapeutic microrobot system.

    abstract::The biomedical applications of wireless robots are an active area of study. In addition to moving to a target lesion, wireless locomotive robots can deliver a therapeutic drug for a specific disease. Thus, they hold great potential as therapeutic devices in blood vessel diseases, such as thrombi and occlusions, and in...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.01.001

    authors: Jeong S,Choi H,Go G,Lee C,Lim KS,Sim DS,Jeong MH,Ko SY,Park JO,Park S

    更新日期:2016-04-01 00:00:00

  • Suitability of commercial barometric pressure sensors to distinguish sitting and standing activities for wearable monitoring.

    abstract::Despite its medical relevance, accurate recognition of sedentary (sitting and lying) and dynamic activities (e.g. standing and walking) remains challenging using a single wearable device. Currently, trunk-worn wearable systems can differentiate sitting from standing with moderate success, as activity classifiers often...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.001

    authors: Massé F,Bourke AK,Chardonnens J,Paraschiv-Ionescu A,Aminian K

    更新日期:2014-06-01 00:00:00

  • Effects of implant drilling parameters for pilot and twist drills on temperature rise in bone analog and alveolar bones.

    abstract::This study concerns the effects of different drilling parameters of pilot drills and twist drills on the temperature rise of alveolar bones during dental implant procedures. The drilling parameters studied here include the feed rate and rotation speed of the drill. The bone temperature distribution was analyzed throug...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.08.009

    authors: Chen YC,Hsiao CK,Ciou JS,Tsai YJ,Tu YK

    更新日期:2016-11-01 00:00:00

  • A model identification approach to quantify impact of whole-body vertical vibrations on limb compliant dynamics and walking stability.

    abstract::Extensive research is ongoing in the field of orthoses/exoskeleton design for efficient lower limbs assistance. However, despite wearable devices reported to improve lower limb mobility, their structural impacts on whole-body vertical dynamics have not been investigated. This study introduced a model identification ap...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.04.005

    authors: Mahmood I,Martinez-Hernandez U,Dehghani-Sanij AA

    更新日期:2020-06-01 00:00:00

  • On-line analysis of middle latency auditory evoked potentials (MLAEP) for monitoring depth of anaesthesia in laboratory rats.

    abstract::In laboratory animals as well as in human beings a depth of anaesthesia, where the subject has no pain or recall of events from the surgery, should be provided. Haemodynamic parameters such as heart rate and blood pressure are not a guarantee for an optimal depth of anaesthesia, especially when using neuromuscular blo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00089-7

    authors: Jensen EW,Nygaard M,Henneberg SW

    更新日期:1998-12-01 00:00:00

  • Apparatus and methods for studying artificial feedback-control of the plantarflexors in paraplegics without interference from the brain.

    abstract::Apparatus has been built to explore the practical feasibility of using automatic control with electrical stimulation of paralysed legs to restore function. The experiments are performed with paraplegics with the aim of achieving a realistic postural task: to see whether the body may be maintained upright by stimulatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(97)00020-9

    authors: Donaldson Nde N,Munih M,Phillips GF,Perkins TA

    更新日期:1997-09-01 00:00:00

  • Morphology based anisotropic finite element models of the proximal femur validated with experimental data.

    abstract::Finite element analysis (FEA) of bones scanned with Quantitative Computed Tomography (QCT) can improve early detection of osteoporosis. The accuracy of these models partially depends on the assigned material properties, but anisotropy of the trabecular bone cannot be fully captured due to insufficient resolution of QC...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.08.010

    authors: Enns-Bray WS,Ariza O,Gilchrist S,Widmer Soyka RP,Vogt PJ,Palsson H,Boyd SK,Guy P,Cripton PA,Ferguson SJ,Helgason B

    更新日期:2016-11-01 00:00:00

  • A nonparametric feature for neonatal EEG seizure detection based on a representation of pseudo-periodicity.

    abstract::Automated methods of neonatal EEG seizure detection attempt to highlight the evolving, stereotypical, pseudo-periodic, nature of EEG seizure while rejecting the nonstationary, modulated, coloured stochastic background in the presence of various EEG artefacts. An important aspect of neonatal seizure detection is, there...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.08.001

    authors: Stevenson NJ,O'Toole JM,Rankine LJ,Boylan GB,Boashash B

    更新日期:2012-05-01 00:00:00

  • A portable monitoring system for measuring weight-bearing during tibial fracture healing.

    abstract::An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal par...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00061-7

    authors: Aranzulla PJ,Muckle DS,Cunningham JL

    更新日期:1998-10-01 00:00:00

  • Comparison of different methods for the determination of the true wave propagation coefficient, in rubber tubes and the canine thoracic aorta.

    abstract::The results from studies of wave propagation in large arteries carried out over the last 25 years have shown that there is a good agreement among values of the imaginary part of the complex propagation coefficient, as expressed by pressure or flow-rate wave propagation velocity. However, there is considerable disparit...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00073-2

    authors: Bertram CD,Gow BS,Greenwald SE

    更新日期:1997-04-01 00:00:00

  • Comparison of calibration methods for accelerometers used in human motion analysis.

    abstract::In the fields of medicine and biomechanics, MEMS accelerometers are increasingly used to perform activity recognition by directly measuring acceleration; to calculate speed and position by numerical integration of the signal; or to estimate the orientation of body parts in combination with gyroscopes. For some of thes...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2016.08.004

    authors: Nez A,Fradet L,Laguillaumie P,Monnet T,Lacouture P

    更新日期:2016-11-01 00:00:00

  • Detection of cardiac late potentials in nonstationary noise.

    abstract::An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00069-0

    authors: Atarius R,Sörnmo L

    更新日期:1997-04-01 00:00:00

  • Mechanical characterization of bone anchors used with a bone-attached, parallel robot for skull surgery.

    abstract::Bone-attached robots and microstereotactic frames, intended for deep brain stimulation and minimally invasive cochlear implantation, typically attach to a patient's skull via bone anchors. A rigid and reliable link between such devices and the skull is mandatory in order to fulfill the high accuracy demands of minimal...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.012

    authors: Kobler JP,Prielozny L,Lexow GJ,Rau TS,Majdani O,Ortmaier T

    更新日期:2015-05-01 00:00:00

  • The formation and function of the sclerosis rim in the femoral head: A biomechanical point of view.

    abstract::Sclerosis rim surrounding the necrotic area is commonly found in necrotic femoral head, but the biomechanical function of sclerosis rim has received relatively little attention. Little is known about the formation and natural history of sclerosis rim. In the present work, we assume that the necrotic change may trigger...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.09.005

    authors: Chen Z,Xu Y,Qi Z,Zho J

    更新日期:2015-12-01 00:00:00

  • Dynamic cerebral autoregulation assessment using an ARX model: comparative study using step response and phase shift analysis.

    abstract::Middle cerebral arterial blood velocity (MCAv) response to spontaneous and manipulated changes of arterial blood pressure (ABP) was studied in eight subjects using a linear autoregressive with exogenous input (ARX) model. ABP and MCAv were measured non-invasively by photoplethysmograph and transcranial Doppler ultraso...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s1350-4533(03)00015-8

    authors: Liu Y,Birch AA,Allen R

    更新日期:2003-10-01 00:00:00

  • Liquid ventilation: a mathematical model of gas diffusion in the premature lung.

    abstract::The liquid ventilation (LV) technique was previously demonstrated to be a valuable alternative to ordinary gas ventilation, particularly for newborn patients with severely distressed lungs. This work describes a mathematical model of gas transfer phenomena occurring within the lungs of a preterm newborn baby ventilate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00041-0

    authors: Costantino ML,Fiore GB

    更新日期:1997-03-01 00:00:00

  • Parametric study on the interface pullout strength of the vertebral body replacement cage using FEM-based Taguchi methods.

    abstract::Improper design of vertebral body cages may seriously affect the interface strength and cause the lose of fixation for a vertebral body replacement. This research used a FEM-based Taguchi method to investigate the effects of various factors to find the robust design of the body cage. Three-dimensional finite element m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.07.001

    authors: Hsu WH,Chao CK,Hsu HC,Lin J,Hsu CC

    更新日期:2009-04-01 00:00:00

  • Multispectral characterization of tissues encountered during laparoscopic colorectal surgery.

    abstract:AIMS:This study investigated the feasibility of automated differentiation between essential tissue types encountered during laparoscopic colorectal surgery using spectral analysis. METHODS:Wide band (440-1830 nm) spectra were collected using an optical fiber probe and spectrometer from freshly explanted, ex vivo, huma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.01.004

    authors: Schols RM,Dunias P,Wieringa FP,Stassen LP

    更新日期:2013-07-01 00:00:00

  • Development and testing of acoustically-matched hydrogel-based electrodes for simultaneous EMG-ultrasound detection.

    abstract::In this manuscript we describe the development and testing of a bipolar electrode for the simultaneous acquisition of ultrasound (US) images and surface electromyograms (EMGs) from the same muscle region. The developed electrode (bEMG-US) consists of two circular sensing regions (20 mm diameter) with fixed inter-elect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.12.002

    authors: Botter A,Beltrandi M,Cerone GL,Gazzoni M,Vieira TMM

    更新日期:2019-02-01 00:00:00

  • Extended Central Tendency Measure and difference plot for heart rate variability analysis.

    abstract::Heart rate variability (HRV) is a non-invasive alternative to analyze the role of the autonomic nervous system (ANS) on heart functioning. Many tools have been developed to analyze collected cardiac data. Among them, the Central Tendency Measure (CTM) is a quantitative method for variability analysis of RR intervals. ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.024

    authors: Belfort RAU,Treccossi SPC,Silva JLF,Pillat VG,Freitas CBN,Dos Santos L

    更新日期:2019-12-01 00:00:00

  • Non-invasive approach towards the in vivo estimation of 3D inter-vertebral movements: methods and preliminary results.

    abstract::A kinematical model of the lower spine was designed and used to obtain a robust estimation of the vertebral rotations during torso movements from skin-surface markers recorded by video-cameras. Markers were placed in correspondence of the anatomical landmarks of the pelvic bone and vertebral spinous and transverse pro...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.08.005

    authors: Cerveri P,Pedotti A,Ferrigno G

    更新日期:2004-12-01 00:00:00

  • Ultrasonography and electromyography based hand motion intention recognition for a trans-radial amputee: A case study.

    abstract::Surface electromyography (sEMG) has dominated upper-limb prosthesis control for decades due to its simplicity and effectiveness [1-3]. However, the inherent variability of EMG signal hinders the flexible and accurate control of advanced multi-functional prosthesis. This study is an attempt to use ultrasonography (US) ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.005

    authors: Wang Z,Fang Y,Zhou D,Li K,Cointet C,Liu H

    更新日期:2020-01-01 00:00:00

  • Experimental determination of the emissivity of bone.

    abstract::Cutting and drilling operations in bone are involved in many orthopedic and otolaryngological surgeries. The temperature elevation of these procedures is potentially harmful to bone and soft tissue cells. The research on this topic aims therefore at minimizing temperature elevation and finding optimal process paramete...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.06.019

    authors: Feldmann A,Zysset P

    更新日期:2016-10-01 00:00:00