Effects of implant drilling parameters for pilot and twist drills on temperature rise in bone analog and alveolar bones.

Abstract:

:This study concerns the effects of different drilling parameters of pilot drills and twist drills on the temperature rise of alveolar bones during dental implant procedures. The drilling parameters studied here include the feed rate and rotation speed of the drill. The bone temperature distribution was analyzed through experiments and numerical simulations of the drilling process. In this study, a three dimensional (3D) elasto-plastic dynamic finite element model (DFEM) was proposed to investigate the effects of drilling parameters on the bone temperature rise. In addition, the FE model is validated with drilling experiments on artificial human bones and porcine alveolar bones. The results indicate that 3D DFEM can effectively simulate the bone temperature rise during the drilling process. During the drilling process with pilot drills or twist drills, the maximum bone temperature occurred in the region of the cancellous bones close to the cortical bones. The feed rate was one of the important factors affecting the time when the maximum bone temperature occurred. Our results also demonstrate that the elevation of bone temperature was reduced as the feed rate increased and the drill speed decreased, which also effectively reduced the risk region of osteonecrosis. These findings can serve as a reference for dentists in choosing drilling parameters for dental implant surgeries.

journal_name

Med Eng Phys

authors

Chen YC,Hsiao CK,Ciou JS,Tsai YJ,Tu YK

doi

10.1016/j.medengphy.2016.08.009

subject

Has Abstract

pub_date

2016-11-01 00:00:00

pages

1314-1321

issue

11

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(16)30186-2

journal_volume

38

pub_type

杂志文章
  • A complete, non-lumped, and verifiable set of upper body segment parameters for three-dimensional dynamic modeling.

    abstract::Dynamic models of the human trunk have been extensively used to investigate the biomechanics of lower back pain and postural instability in different populations. Despite their diverse applications, previous models rely on intrinsic upper body segment parameters (UBSP), e.g., each segment's mass-inertia characteristic...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.09.008

    authors: Vette AH,Yoshida T,Thrasher TA,Masani K,Popovic MR

    更新日期:2011-01-01 00:00:00

  • Minimal haemodynamic system model including ventricular interaction and valve dynamics.

    abstract::Characterising circulatory dysfunction and choosing a suitable treatment is often difficult and time consuming, and can result in a deterioration in patient condition, or unsuitable therapy choices. A stable minimal model of the human cardiovascular system (CVS) is developed with the ultimate specific aim of assisting...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2003.10.001

    authors: Smith BW,Chase JG,Nokes RI,Shaw GM,Wake G

    更新日期:2004-03-01 00:00:00

  • Design of tissue engineering scaffolds based on hyperbolic surfaces: structural numerical evaluation.

    abstract::Tissue engineering represents a new field aiming at developing biological substitutes to restore, maintain, or improve tissue functions. In this approach, scaffolds provide a temporary mechanical and vascular support for tissue regeneration while tissue in-growth is being formed. These scaffolds must be biocompatible,...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.05.006

    authors: Almeida HA,Bártolo PJ

    更新日期:2014-08-01 00:00:00

  • TETRA mobile radios interfere with electroencephalography recording equipment.

    abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.009

    authors: Fouquet NC,Hawken MB,Elliott P,Burgess AP

    更新日期:2013-11-01 00:00:00

  • Detection of cardiac late potentials in nonstationary noise.

    abstract::An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00069-0

    authors: Atarius R,Sörnmo L

    更新日期:1997-04-01 00:00:00

  • Finite-element design and optimization of a three-dimensional tetrahedral porous titanium scaffold for the reconstruction of mandibular defects.

    abstract::Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and comple...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.015

    authors: Luo D,Rong Q,Chen Q

    更新日期:2017-09-01 00:00:00

  • Probabilistic analysis of an uncemented total hip replacement.

    abstract::This paper describes the application of probabilistic design methods to the analysis of the behaviour of an uncemented total hip replacement femoral component implanted in a proximal femur. Probabilistic methods allow variations in factors which control the behaviour of the implanted femur (the input parameters) to be...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.01.002

    authors: Dopico-González C,New AM,Browne M

    更新日期:2009-05-01 00:00:00

  • Acoustic power measurement of high-intensity focused ultrasound transducer using a pressure sensor.

    abstract::The acoustic power of high-intensity focused ultrasound (HIFU) is an important parameter that should be measured prior to each treatment to guarantee effective and safe outcomes. A new calibration technique was developed that involves estimating the pressure distribution, calculating the acoustic power using an underw...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.01.014

    authors: Zhou Y

    更新日期:2015-03-01 00:00:00

  • Multi-adaptive filtering technique for surface somatosensory evoked potentials processing.

    abstract::Somatosensory evoked potential (SEP) testing has been widely applied to diagnosis of various neurological disorders. However, SEP recorded using surface electrodes is buried in noises, which makes the signal-to-noise ratio (SNR) very poor. Conventional averaging method usually requires up to thousands of raw SEP input...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.007

    authors: Lam BS,Hu Y,Lu WW,Luk KD,Chang CQ,Qiu W,Chan FH

    更新日期:2005-04-01 00:00:00

  • In vitro model of intravenous fluid administration: analysis of vein resistance to rapid fluid delivery.

    abstract::Rapid fluid administration is the cornerstone of successful trauma resuscitation of patients in a state of shock. Intravenous (IV) fluid delivery is a physical intrusion into a vein which results in a complex interaction between the rigid catheter and the compliant vein. We present an experimental model of IV infusion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00046-1

    authors: Yaniv S,Halpern P,Aladgem D,Zaretsky U,Elad D

    更新日期:2000-07-01 00:00:00

  • Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis.

    abstract::The biomechanical strength of the skeleton, and hence the risk of future fractures, depends on both the bone quantity (assessed in terms of bone mineral density) and bone quality (assessed in terms of the integrity of its internal architecture). Precise methods of measuring the calcium-equivalent density of both the t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(96)00011-2

    authors: Dougherty G

    更新日期:1996-10-01 00:00:00

  • A model identification approach to quantify impact of whole-body vertical vibrations on limb compliant dynamics and walking stability.

    abstract::Extensive research is ongoing in the field of orthoses/exoskeleton design for efficient lower limbs assistance. However, despite wearable devices reported to improve lower limb mobility, their structural impacts on whole-body vertical dynamics have not been investigated. This study introduced a model identification ap...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.04.005

    authors: Mahmood I,Martinez-Hernandez U,Dehghani-Sanij AA

    更新日期:2020-06-01 00:00:00

  • Baseline drift removal and denoising of MCG data using EEMD: role of noise amplitude and the thresholding effect.

    abstract::We adopt the Ensemble Empirical Mode Decomposition (EEMD) method, with an appropriate thresholding on the Intrinsic Mode Functions (IMFs), to denoise the magnetocardiography (MCG) signal. To this end, we discuss the two associated problems that relate to: (i) the amplitude of noise added to the observed signal in the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.023

    authors: Mariyappa N,Sengottuvel S,Parasakthi C,Gireesan K,Janawadkar MP,Radhakrishnan TS,Sundar CS

    更新日期:2014-10-01 00:00:00

  • Construction, in vitro and in vivo evaluation of an in-house conductance meter for measurement of skin hydration.

    abstract::Different probes are used in dermato-cosmetic research to measure the electrical properties of the skin. The principle governing the choice of the geometry and material of the measuring probe is not well defined in the literature and some device's measuring principles are not accessible for the scientific community. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.02.008

    authors: Hamed SH,Altrabsheh B,Assa'd T,Jaradat S,Alshra'ah M,Aljamal A,Alkhatib HS,Almalty AM

    更新日期:2012-12-01 00:00:00

  • Reproducible metacarpal joint space width measurements using 3D analysis of images acquired with high-resolution peripheral quantitative computed tomography.

    abstract:OBJECTIVE:Joint space narrowing is an important feature of progressive joint damage and functional impairment in rheumatoid arthritis (RA). Methods to provide a continuous measurement of joint space width have not been adopted in research or clinical settings. High-resolution peripheral quantitative computed tomography...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.003

    authors: Barnabe C,Buie H,Kan M,Szabo E,Barr SG,Martin L,Boyd SK

    更新日期:2013-10-01 00:00:00

  • Experimental determination of the emissivity of bone.

    abstract::Cutting and drilling operations in bone are involved in many orthopedic and otolaryngological surgeries. The temperature elevation of these procedures is potentially harmful to bone and soft tissue cells. The research on this topic aims therefore at minimizing temperature elevation and finding optimal process paramete...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.06.019

    authors: Feldmann A,Zysset P

    更新日期:2016-10-01 00:00:00

  • The effect of the subcutaneous fat on the transfer of current through skin and into muscle.

    abstract::The present investigation was conducted to see the effect of subcutaneous fat on the transmission characteristics of an electrical stimulus applied to the skin and conducted to skeletal muscle. Two groups of subjects participated. In one, the subjects were three males and three females whose average age was 24.6+/-1.5...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.02.009

    authors: Petrofsky J

    更新日期:2008-11-01 00:00:00

  • Mechanical behaviour of DNA molecules--elasticity and migration.

    abstract::A novel multi-scale simulation method developed to describe mesoscale phenomena occurring in biofluidic devices is presented. The approach combines the macro-scale modelling of the carrier fluid and the micro-scale description of the transported macromolecules or compounds. Application of the approach is demonstrated ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.003

    authors: Benke M,Shapiro E,Drikakis D

    更新日期:2011-09-01 00:00:00

  • A multi-sample denaturation temperature tester for collagenous biomaterials.

    abstract::The temperature at which collagen denatures from a triple helix to a random coil structure is a useful measure of the degree of crosslinking. A new multi-sample denaturation temperature tester (DTT) has been constructed for rapid determination of the collagen denaturation temperature of natural tissues and collagenous...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)91882-h

    authors: Lee JM,Pereira CA,Abdulla D,Naimark WA,Crawford I

    更新日期:1995-03-01 00:00:00

  • An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones.

    abstract::Subject-specific FE-models of human long bones have to predict mechanical parameters with sufficient accuracy to be applicable in a clinical setting. One of the main aspects in subject-specific FE-models of bones regarding accuracy is the modeling of the material inhomogeneity. The goal of this study was therefore to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.022

    authors: Eberle S,Göttlinger M,Augat P

    更新日期:2013-07-01 00:00:00

  • Effect of specimen length: are the mechanics of individual motion segments comparable in functional spinal units and multisegment specimens?

    abstract::Functional spinal units (FSUs) are frequently used for in vitro mechanical testing. This approach assumes that the mechanical behavior of the FSUs is equivalent to the mechanics of these segments within the intact spine. The purpose of this study was to determine whether normal spinal mechanics are compromised in FSU ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00152-2

    authors: Dickey JP,Kerr DJ

    更新日期:2003-04-01 00:00:00

  • Biomechanical design using in-vitro finite element modeling of distal femur fracture plates made from semi-rigid materials versus traditional metals for post-operative toe-touch weight-bearing.

    abstract::This proof-of-concept study designs distal femur fracture plates from semi-rigid materials vs. traditional metals for toe-touch weight-bearing recommended to patients immediately after surgery. The two-fold goal was to (a) reduce stress shielding (SS) by increasing cortical bone stress thereby reducing the risk of bon...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.11.015

    authors: Gee A,Bougherara H,Schemitsch EH,Zdero R

    更新日期:2021-01-01 00:00:00

  • A numerical hemodynamic tool for predictive vascular surgery.

    abstract::We suggest a new approach to peripheral vascular bypass surgery planning based on solving the one-dimensional (1D) governing equations of blood flow in patient-specific models. The aim of the present paper is twofold. First, we present the coupled 1D-0D model based on a discontinuous Galerkin method in a comprehensive...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.04.015

    authors: Marchandise E,Willemet M,Lacroix V

    更新日期:2009-01-01 00:00:00

  • Bioelectric signal detrending using smoothness prior approach.

    abstract::Bioelectric signals such as electromyogram (EMG) and electrocardiogram (ECG) are often affected by various low-frequency trending interferences. It is critical to remove these interferences from the recordings so that the critical features of the bioelectric signals could be clearly observed. In this study, an advance...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.05.009

    authors: Zhang F,Chen S,Zhang H,Zhang X,Li G

    更新日期:2014-08-01 00:00:00

  • Influence of antegrade pulmonary blood flow on the hemodynamic performance of bidirectional cavopulmonary anastomosis: a numerical study.

    abstract::The role and effect of preserved antegrade pulmonary blood flow (APBF) at the time of bidirectional cavopulmonary anastomosis (BCPA) in the management of single-ventricle physiology is controversial. We investigated the influence of APBF on the fluid dynamics of BCPA connection using computational fluid dynamics (CFD)...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.07.004

    authors: Sun Q,Wan D,Liu J,Liu Y,Zhu M,Hong H,Sun Y,Wang Q

    更新日期:2009-03-01 00:00:00

  • Enabling variable-stiffness hand rehabilitation orthoses with dielectric elastomer transducers.

    abstract::Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.10.015

    authors: Carpi F,Frediani G,Gerboni C,Gemignani J,De Rossi D

    更新日期:2014-02-01 00:00:00

  • Assessment of the initial viscoelastic properties of a critical segmental long bone defect reconstructed with impaction bone grafting and intramedullary nailing.

    abstract:INTRODUCTION:This study compared the initial viscoelastic properties of a segmental tibial defect stabilized with intramedullary nailing and impaction bone grafting to that of a transverse fracture stabilized with intramedullary nailing. MATERIALS AND METHODS:Seven sheep tibiae were tested in compression (1000N), bend...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.09.003

    authors: Costi JJ,Stanley RM,Ding B,Solomon LB

    更新日期:2014-01-01 00:00:00

  • Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems.

    abstract::Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Ti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.011

    authors: Jauch SY,Coles LG,Ng LV,Miles AW,Gill HS

    更新日期:2014-09-01 00:00:00

  • Herringbone-like hydrodynamic structures in microchannels: A CFD model to evaluate the enhancement of surface binding.

    abstract::Selected adsorption efficiency of a molecule in solution in a microchannel is strongly influenced by the convective/diffusive mass transport phenomena that supply the target molecule to the adsorption surface. In a standard microchannel with a rectangular cross section, laminar flow regime limits the fluid mixing, thu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.07.003

    authors: Bianchi E,Piergiovanni M,Arrigoni C,Fukuda J,Gautieri A,Moretti M,Dubini G

    更新日期:2017-10-01 00:00:00

  • Intramedullary femoral nails: one or two lag screws? A preliminary study.

    abstract::Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00081-3

    authors: Wang CJ,Brown CJ,Yettram AL,Procter P