Non-invasive approach towards the in vivo estimation of 3D inter-vertebral movements: methods and preliminary results.

Abstract:

:A kinematical model of the lower spine was designed and used to obtain a robust estimation of the vertebral rotations during torso movements from skin-surface markers recorded by video-cameras. Markers were placed in correspondence of the anatomical landmarks of the pelvic bone and vertebral spinous and transverse processes, and acquired during flexion, lateral bending and axial motions. In the model calibration stage, a motion-based approach was used to compute the rotation axes and centres of the functional segmental units. Markers were mirrored into virtual points located on the model surface, expressed in the local reference system of coordinates. The spine motion assessment was solved into the domain of extended Kalman filters: at each frame of the acquisition, the model pose was updated by minimizing the distances between the measured 2D marker projections on the cameras and the corresponding back-projections of virtual points located on the model surface. The novelty of the proposed technique rests on the fact that the varying location of the rotation centres of the functional segmental units can be tracked directly during motion computation. In addition, we show how the effects of skin artefacts on orientation data can be taken into account. As a result, the kinematical estimation of simulated motions shows that orientation artefacts were reduced by a factor of at least 50%. Preliminary experiments on real motion confirmed the reliability of the proposed method with results in agreement with classical studies in literature.

journal_name

Med Eng Phys

authors

Cerveri P,Pedotti A,Ferrigno G

doi

10.1016/j.medengphy.2004.08.005

subject

Has Abstract

pub_date

2004-12-01 00:00:00

pages

841-53

issue

10

eissn

1350-4533

issn

1873-4030

pii

S1350453304001407

journal_volume

26

pub_type

杂志文章
  • Intramedullary femoral nails: one or two lag screws? A preliminary study.

    abstract::Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00081-3

    authors: Wang CJ,Brown CJ,Yettram AL,Procter P

    更新日期:2000-11-01 00:00:00

  • Non-invasive measurement of hepatic oxygenation by an oxygen electrode in human orthotopic liver transplantation.

    abstract::Precise evaluation of graft reperfusion is difficult in clinical liver transplantation. The oxygen electrode (OE) is a novel technique to detect blood flow indirectly by measuring the quantity of oxygen which can diffuse from the hepatic tissue to the surface electrode. Application of the surface OE does not influence...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00060-6

    authors: Seifalian AM,Mallett S,Piasecki C,Rolles K,Davidson BR

    更新日期:2000-06-01 00:00:00

  • A computational model-based study on the exchangeability of hepatic venous pressure gradients measured in multiple hepatic veins.

    abstract::Hepatic venous pressure gradient (HVPG) is a hemodynamic index widely used for evaluating the severity of portal hypertension. Theoretically, HVPG can be measured in any of the three major (i.e., right, middle and left) hepatic veins (HVs); however, it remains unclear whether HVPGs measured in different HVs are exchan...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.07.022

    authors: Wang T,Liang F,Li L,Zhang W,Wang G,Wang J,Zhang C,Qi X

    更新日期:2020-10-01 00:00:00

  • Pilot study of a surgical robot system for zygomatic implant placement.

    abstract::Zygomatic implant technology has been regarded as an alternative treatment to massive grafting surgery in the severe atrophic maxillary. Nowadays, the assistant method with a real-time surgical navigation has been applied to reduce the risks of zygomatic implant placement. However, the accuracy of the complex operatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.020

    authors: Cao Z,Qin C,Fan S,Yu D,Wu Y,Qin J,Chen X

    更新日期:2020-01-01 00:00:00

  • Modelling the heart with the atrioventricular plane as a piston unit.

    abstract::Medical imaging and clinical studies have proven that the heart pumps by means of minor outer volume changes and back-and-forth longitudinal movements in the atrioventricular (AV) region. The magnitude of AV-plane displacement has also shown to be a reliable index for diagnosis of heart failure. Despite this, AV-plane...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.11.002

    authors: Maksuti E,Bjällmark A,Broomé M

    更新日期:2015-01-01 00:00:00

  • Determination of the position and orientation of artificial knee implants using markers embedded in a bone: preliminary in vitro experiments.

    abstract::This study describes the method of determination of the position and orientation of artificial knee implants using a single-plane radiograph. To simplify the 3D/2D matching problem, we proposed to use small markers embedded in a bone. From the image coordinates of markers, it is possible to estimate the position and o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00037-7

    authors: Imai S,Higashijima K,Ishida A,Fukuoka Y,Hoshino A,Minamitani H

    更新日期:2003-06-01 00:00:00

  • Effect of different inertial parameter sets on joint moment calculation during stair ascending and descending.

    abstract::The reliability of internal joint moment calculation in gait analysis during daily living activities is fundamental for clinical decisions based on joint function. This calculation, obtained by means of the inverse dynamics, depends on several modelling factors, such as assumptions on the segments and on the relevant ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.12.002

    authors: Fantozzi S,Stagni R,Cappello A,Leardini A

    更新日期:2005-07-01 00:00:00

  • Loosening detection of the femoral component of hip prostheses with extracorporeal shockwaves: a pilot study.

    abstract::The diagnosis of aseptic loosening of hip implants is often challenging. A vibrational analysis of the bone-implant interface could be an alternative method to analyze the fixation of endoprostheses. We assessed an innovative and new approach for excitation by using extracorporeal shockwaves in this study. In three ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.11.011

    authors: Rieger JS,Jaeger S,Kretzer JP,Rupp R,Bitsch RG

    更新日期:2015-02-01 00:00:00

  • Bi-directional flow sensor with a wide dynamic range for medical applications.

    abstract::This paper describes a novel three-wire thermal flow sensor for medical applications. The present innovation for low-frequency measurements involves the use of a pulsed-wire anemometer with a comparatively large wire diameter (12.5 microm and larger) together with a novel signal processing approach. A small wire is he...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.06.002

    authors: Al-Salaymeh A,Jovanović J,Durst F

    更新日期:2004-10-01 00:00:00

  • Fuzzy clustering of gait patterns of patients after ankle arthrodesis based on kinematic parameters.

    abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00020-0

    authors: Su F,Wu W,Cheng Y,Chou Y

    更新日期:2001-03-01 00:00:00

  • fMRI brain mapping during motion capture and FES induced motor tasks: signal to noise ratio assessment.

    abstract::Functional Electrical Stimulation (FES) is a well known clinical rehabilitation procedure, however the neural mechanisms that underlie this treatment at Central Nervous System (CNS) level are still not completely understood. Functional magnetic resonance imaging (fMRI) is a suitable tool to investigate effects of reha...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.005

    authors: Gandolla M,Ferrante S,Casellato C,Ferrigno G,Molteni F,Martegani A,Frattini T,Pedrocchi A

    更新日期:2011-10-01 00:00:00

  • Assessment of body composition in adolescent subjects with anorexia nervosa by bioimpedance.

    abstract::Our main goal was to test various impedance methods for measuring body composition in adolescents with anorexia nervosa (AN) during refeeding therapy. A specific objective was to compare the information provided by a foot-to-foot impedancemeter (FFI) with that supplied by a medical multifrequency impedancemeter and by...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.09.005

    authors: Moreno MV,Djeddi DD,Jaffrin MY

    更新日期:2008-07-01 00:00:00

  • In vitro determination of the passive knee flexion axis: Effects of axis alignment on coupled tibiofemoral motions.

    abstract::The natural passive flexion axis of human cadaveric knees was determined using a technique that minimized coupled tibiofemoral motions (translations and rotations), and the kinematic effects of mal-positioned flexion axes were determined. The femur was clamped in an apparatus that allowed unconstrained tibial motions ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.03.009

    authors: Markolf KL,Yang PR,Joshi NB,Petrigliano FA,McAllister DR

    更新日期:2019-05-01 00:00:00

  • A novel integrated mechanomyogram-vocalization access solution.

    abstract::We introduce a novel dual-switch control paradigm based on the simultaneous measurement of frontalis muscle mechanomyography (MMG) and vocalizations (humming) using a single contact microphone attached to the forehead. Vibrations of the face and skull during vocalization are manifested as periodic high-frequency compo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.06.003

    authors: Alves N,Falk TH,Chau T

    更新日期:2010-10-01 00:00:00

  • Effects of cartilage rings on airflow and particle deposition in the trachea and main bronchi.

    abstract::In most computational fluid dynamic (CFD) analysis of the human lung, it has been assumed that the trachea and branches of the lung have smooth walls. In order to determine if this is a valid assumption, the effects of cartilage rings on airflow and particle deposition in the lungs was determined through conducting si...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.06.010

    authors: Russo J,Robinson R,Oldham MJ

    更新日期:2008-06-01 00:00:00

  • Suitability of commercial barometric pressure sensors to distinguish sitting and standing activities for wearable monitoring.

    abstract::Despite its medical relevance, accurate recognition of sedentary (sitting and lying) and dynamic activities (e.g. standing and walking) remains challenging using a single wearable device. Currently, trunk-worn wearable systems can differentiate sitting from standing with moderate success, as activity classifiers often...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.001

    authors: Massé F,Bourke AK,Chardonnens J,Paraschiv-Ionescu A,Aminian K

    更新日期:2014-06-01 00:00:00

  • Classification of waist-acceleration signals in a continuous walking record.

    abstract::We attempted to distinguish walking on level ground from walking on a stairway using waist acceleration signals. A triaxial accelerometer was fixed to the subject's waist and the three acceleration signals were recorded by a portable data logger at a sampling rate of 256 Hz. Twenty healthy male subjects were asked to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00041-2

    authors: Sekine M,Tamura T,Togawa T,Fukui Y

    更新日期:2000-05-01 00:00:00

  • An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones.

    abstract::Subject-specific FE-models of human long bones have to predict mechanical parameters with sufficient accuracy to be applicable in a clinical setting. One of the main aspects in subject-specific FE-models of bones regarding accuracy is the modeling of the material inhomogeneity. The goal of this study was therefore to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.022

    authors: Eberle S,Göttlinger M,Augat P

    更新日期:2013-07-01 00:00:00

  • Development of a small wireless device for perspiration monitoring.

    abstract::A small and wireless device that can capture the temporal pattern of perspiration by a novel structure of water vapor collection combined with reusable desiccant has been developed. The novel device consists of a small cylindrical case with a temperature/relative humidity sensor, battery-driven data logger, and silica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.009

    authors: Ogai K,Fukuoka M,Kitamura K,Uchide K,Nemoto T

    更新日期:2016-04-01 00:00:00

  • Sensitivity analysis of the position of the intervertebral centres of reaction in upright standing--a musculoskeletal model investigation of the lumbar spine.

    abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.003

    authors: Zander T,Dreischarf M,Schmidt H

    更新日期:2016-03-01 00:00:00

  • A practical technique for measuring human biofluid conductivity using high gain-frequency characteristics.

    abstract::Currently, the study of ion composition and performance in human biofluids plays an important role in biomedical engineering research and technology. This field may become universal for human diagnostics; it allows early detection of different diseases in humans by measuring changes in ion behaviour in human biofluids...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.007

    authors: Al-Nabulsi JI,Aloquili O,Ausheva V,Yuldashev ZM

    更新日期:2011-11-01 00:00:00

  • Accurate segmentation of respiration waveforms from infants enabling identification and classification of irregular breathing patterns.

    abstract::Although the precise causes of Sudden Infant Death Syndrome (SIDS) are still unclear there is evidence to suggest that hypoxaemia may be a contributory factor. Transcutaneous oxygen monitors can be used but are unsatisfactory for young babies in the home. As an alternative approach, respiratory patterns can be studied...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90005-1

    authors: Wilks PA,English MJ

    更新日期:1994-01-01 00:00:00

  • Review on aspects of artificial tactile feedback in laparoscopic surgery.

    abstract::Since direct manual tissue palpation is not possible in laparoscopic surgery, feedback information on tactile tissue properties is considerably diminished. Restoring part of the surgeon's sense of touch through devices capable of providing artificial tactile feedback (ATF) is an active field of applied research and de...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2009.06.003

    authors: Schostek S,Schurr MO,Buess GF

    更新日期:2009-10-01 00:00:00

  • The formation and function of the sclerosis rim in the femoral head: A biomechanical point of view.

    abstract::Sclerosis rim surrounding the necrotic area is commonly found in necrotic femoral head, but the biomechanical function of sclerosis rim has received relatively little attention. Little is known about the formation and natural history of sclerosis rim. In the present work, we assume that the necrotic change may trigger...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.09.005

    authors: Chen Z,Xu Y,Qi Z,Zho J

    更新日期:2015-12-01 00:00:00

  • Segmentation of magnetic resonance images using a combination of neural networks and active contour models.

    abstract::Segmentation of medical images is very important for clinical research and diagnosis, leading to a requirement for robust automatic methods. This paper reports on the combined use of a neural network (a multilayer perceptron, MLP) and active contour model ('snake') to segment structures in magnetic resonance (MR) imag...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s1350-4533(03)00137-1

    authors: Middleton I,Damper RI

    更新日期:2004-01-01 00:00:00

  • LES of non-Newtonian physiological blood flow in a model of arterial stenosis.

    abstract::Large Eddy Simulation (LES) is performed to study the physiological pulsatile transition-to-turbulent non-Newtonian blood flow through a 3D model of arterial stenosis by using five different blood viscosity models: (i) Power-law, (ii) Carreau, (iii) Quemada, (iv) Cross and (v) modified-Casson. The computational domain...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.013

    authors: Molla MM,Paul MC

    更新日期:2012-10-01 00:00:00

  • Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis.

    abstract::The biomechanical strength of the skeleton, and hence the risk of future fractures, depends on both the bone quantity (assessed in terms of bone mineral density) and bone quality (assessed in terms of the integrity of its internal architecture). Precise methods of measuring the calcium-equivalent density of both the t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(96)00011-2

    authors: Dougherty G

    更新日期:1996-10-01 00:00:00

  • Data dependent random forest applied to screening for laryngeal disorders through analysis of sustained phonation: acoustic versus contact microphone.

    abstract::Comprehensive evaluation of results obtained using acoustic and contact microphones in screening for laryngeal disorders through analysis of sustained phonation is the main objective of this study. Aiming to obtain a versatile characterization of voice samples recorded using microphones of both types, 14 different set...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.12.005

    authors: Verikas A,Gelzinis A,Vaiciukynas E,Bacauskiene M,Minelga J,Hållander M,Uloza V,Padervinskis E

    更新日期:2015-02-01 00:00:00

  • Smartphone application for emergency signal detection.

    abstract::Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). Th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.002

    authors: Figueiredo IN,Leal C,Pinto L,Bolito J,Lemos A

    更新日期:2016-09-01 00:00:00

  • A nonparametric feature for neonatal EEG seizure detection based on a representation of pseudo-periodicity.

    abstract::Automated methods of neonatal EEG seizure detection attempt to highlight the evolving, stereotypical, pseudo-periodic, nature of EEG seizure while rejecting the nonstationary, modulated, coloured stochastic background in the presence of various EEG artefacts. An important aspect of neonatal seizure detection is, there...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.08.001

    authors: Stevenson NJ,O'Toole JM,Rankine LJ,Boylan GB,Boashash B

    更新日期:2012-05-01 00:00:00