Biomechanical analysis using FEA and experiments of a standard plate method versus three cable methods for fixing acetabular fractures with simultaneous THA.

Abstract:

:Acetabular fractures potentially account for up to half of all pelvic fractures, while pelvic fractures potentially account for over one-tenth of all human bone fractures. This is the first biomechanical study to assess acetabular fracture fixation using plates versus cables in the presence of a total hip arthroplasty, as done for the elderly. In Phase 1, finite element (FE) models compared a standard plate method versus 3 cable methods for repairing an acetabular fracture (type: anterior column plus posterior hemi-transverse) subjected to a physiological-type compressive load of 2207N representing 3 x body weight for a 75kg person during walking. FE stress maps were compared to choose the most mechanically stable cable method, i.e. lowest peak bone stress. In Phase 2, mechanical tests were then done in artificial hemipelvises to compare the standard plate method versus the optimal cable method selected from Phase 1. FE analysis results showed peak bone stresses of 255MPa (Plate method), 205MPa (Mears cable method), 250MPa (Kang cable method), and 181MPa (Mouhsine cable method). Mechanical tests then showed that the Plate method versus the Mouhsine cable method selected from Phase 1 had higher stiffness (662versus 385N/mm, p=0.001), strength (3210versus 2060N, p=0.009), and failure energy (8.8versus 6.2J, p=0.002), whilst they were statistically equivalent for interfragmentary sliding (p≥0.179) and interfragmentary gapping (p≥0.08). The Plate method had superior mechanical properties, but the Mouhsine cable method may be a reasonable alternative if osteoporosis prevents good screw thread interdigitation during plating.

journal_name

Med Eng Phys

authors

Aziz MSR,Dessouki O,Samiezadeh S,Bougherara H,Schemitsch EH,Zdero R

doi

10.1016/j.medengphy.2017.06.004

subject

Has Abstract

pub_date

2017-08-01 00:00:00

pages

71-78

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(17)30142-X

journal_volume

46

pub_type

杂志文章
  • Validation of three-dimensional model-based tibio-femoral tracking during running.

    abstract::The purpose of this study was to determine the accuracy of a radiographic model-based tracking technique that measures the three-dimensional in vivo motion of the tibio-femoral joint during running. Tantalum beads were implanted into the femur and tibia of three subjects and computed tomography (CT) scans were acquire...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2008.03.003

    authors: Anderst W,Zauel R,Bishop J,Demps E,Tashman S

    更新日期:2009-01-01 00:00:00

  • Construction, in vitro and in vivo evaluation of an in-house conductance meter for measurement of skin hydration.

    abstract::Different probes are used in dermato-cosmetic research to measure the electrical properties of the skin. The principle governing the choice of the geometry and material of the measuring probe is not well defined in the literature and some device's measuring principles are not accessible for the scientific community. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.02.008

    authors: Hamed SH,Altrabsheh B,Assa'd T,Jaradat S,Alshra'ah M,Aljamal A,Alkhatib HS,Almalty AM

    更新日期:2012-12-01 00:00:00

  • Investigation to predict patellar tendon reflex using motion analysis technique.

    abstract::The investigation of patellar tendon reflex involves development of a reflex hammer holder, kinematic data collection and analysis of patellar reflex responses using motion analysis techniques. The main aim of this research is to explore alternative means of assessing reflexes as a part of routine clinical diagnosis. ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2010.11.002

    authors: Tham LK,Osman NA,Lim KS,Pingguan-Murphy B,Abas WA,Zain NM

    更新日期:2011-05-01 00:00:00

  • Functional evaluation of natural sensory feedback incorporated in a hand grasp neuroprosthesis.

    abstract::We investigated whether automatic control of a hand grasp neuroprosthesis by means of signals from natural sensors in the skin of the index finger can mimic the natural control of grasp force in an important task of daily living, namely eating. We designed a simulated eating task with the same ratio of rest and activi...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2004.03.002

    authors: Inmann A,Haugland M

    更新日期:2004-07-01 00:00:00

  • Monolithic superelastic rods with variable flexural stiffness for spinal fusion: modeling of the processing-properties relationship.

    abstract::The concept of a monolithic Ti-Ni spinal rod with variable flexural stiffness is proposed to reduce the risks associated with spinal fusion. The variable stiffness is conferred to the rod using the Joule-heating local annealing technique. The annealing temperature and the mechanical properties' distributions resulted ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.07.012

    authors: Facchinello Y,Brailovski V,Petit Y,Mac-Thiong JM

    更新日期:2014-11-01 00:00:00

  • A multi-scale feedback ratio analysis of heartbeat interval series in healthy vs. cardiac patients.

    abstract::The second-order difference plot, as a modified Poincaré plot, is one of the important approaches for assessing the dynamics of heart rate variability. However, corresponding quantitative analysis methods are relatively limited. Based on the second-order difference plot, we propose a novel method, called the multi-sca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.015

    authors: Huo C,Huang X,Ni H,Liu H,Bian C,Ning X

    更新日期:2014-12-01 00:00:00

  • A computational assessment of the hemodynamic effects of crossed and non-crossed bifurcated stent-graft devices for the treatment of abdominal aortic aneurysms.

    abstract::There are several issues attributed with abdominal aortic aneurysm endovascular repair. The positioning of bifurcated stent-grafts (SG) may affect SG hemodynamics. The hemodynamics and geometrical parameters of crossing or non-crossing graft limbs have not being totally accessed. Eight patient-specific SG devices and ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.011

    authors: Stefanov F,McGloughlin T,Morris L

    更新日期:2016-12-01 00:00:00

  • Non-invasive approach towards the in vivo estimation of 3D inter-vertebral movements: methods and preliminary results.

    abstract::A kinematical model of the lower spine was designed and used to obtain a robust estimation of the vertebral rotations during torso movements from skin-surface markers recorded by video-cameras. Markers were placed in correspondence of the anatomical landmarks of the pelvic bone and vertebral spinous and transverse pro...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.08.005

    authors: Cerveri P,Pedotti A,Ferrigno G

    更新日期:2004-12-01 00:00:00

  • MRI/SPECT-based diagnosis and CT-guided high-intensity focused-ultrasound treatment system in MPTP mouse model of Parkinson's disease.

    abstract::Single-photon emission computed tomography (SPECT) of dopamine transporters with (99m)Tc-TRODAT-1 has recently been proposed to offer valuable information for the diagnosis of Parkinson's disease (PD). Furthermore, High-intensity focused ultrasound (HIFU) is a newly developed technique in which the energy of ultrasoun...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.01.006

    authors: Lee JD,Huang CH,Yang ST,Chu YH,Shieh YY,Chen JW,Lin KJ

    更新日期:2013-02-01 00:00:00

  • Modelling the heart with the atrioventricular plane as a piston unit.

    abstract::Medical imaging and clinical studies have proven that the heart pumps by means of minor outer volume changes and back-and-forth longitudinal movements in the atrioventricular (AV) region. The magnitude of AV-plane displacement has also shown to be a reliable index for diagnosis of heart failure. Despite this, AV-plane...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.11.002

    authors: Maksuti E,Bjällmark A,Broomé M

    更新日期:2015-01-01 00:00:00

  • Low torque levels can initiate a removal of the passivation layer and cause fretting in modular hip stems.

    abstract::Taper connections of modular hip prostheses are at risk of fretting and corrosion, which can result in reduced implant survival. The purpose of this study was to identify the minimum torque required to initiate a removal of the passivation layer at the taper interface as a function of assembly force and axial load. Ti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.011

    authors: Jauch SY,Coles LG,Ng LV,Miles AW,Gill HS

    更新日期:2014-09-01 00:00:00

  • Variation of the impact duration during the in vitro insertion of acetabular cup implants.

    abstract::The acetabular cup (AC) is an implant impacted into a bone cavity and used for hip prosthesis surgery. Initial stability of the AC is an important factor for long term surgical success. The aim of this study is to determine the variations of the impact duration during AC implant insertion. Twenty-two bone samples take...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.005

    authors: Mathieu V,Michel A,Flouzat Lachaniette CH,Poignard A,Hernigou P,Allain J,Haïat G

    更新日期:2013-11-01 00:00:00

  • A 16-channel SQUID-device for biomagnetic investigations of small objects.

    abstract::Biomagnetic investigations in basic physiological research using animals require measurement devices different from commercial biomagnetometers used in human investigations. Two major problems have to be tackled in the design of such biomagnetometers. First, the spatial sampling needs to be much higher. Second, the di...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00088-0

    authors: Nowak H,Giessler F,Huonker R,Haueisen J,Röther J,Eiselt M

    更新日期:1999-10-01 00:00:00

  • Resonant frequency analysis of dental implants.

    abstract::Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing stead...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.02.008

    authors: Rittel D,Dorogoy A,Haïat G,Shemtov-Yona K

    更新日期:2019-04-01 00:00:00

  • Surface-based modeling of muscles: Functional simulation of the shoulder.

    abstract::Musculoskeletal simulations are an essential tool for studying functional implications of pathologies and of potential surgical outcomes, e.g., for the complex shoulder anatomy. Most shoulder models rely on line-segment approximation of muscles with potential limitations. Comprehensive shoulder models based on continu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.04.010

    authors: Péan F,Goksel O

    更新日期:2020-08-01 00:00:00

  • A numerical and experimental study of periodic flow in a model of a corrugated vessel with application to stented arteries.

    abstract::The investigation presented in this paper has attempted to study, from a fluid dynamics point of view, the consequences of the presence of a stent on the flow of blood. The method adopted is mainly by numerical simulation using a finite element technique, but visualization experiments and an analytical study have also...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00072-2

    authors: Natarajan S,Mokhtarzadeh-Dehghan MR

    更新日期:2000-10-01 00:00:00

  • Respiratory effort from the photoplethysmogram.

    abstract::The potential for a simple, non-invasive measure of respiratory effort based on the pulse oximeter signal - the photoplethysmogram or 'pleth' - was investigated in a pilot study. Several parameters were developed based on a variety of manifestations of respiratory effort in the signal, including modulation changes in ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.12.010

    authors: Addison PS

    更新日期:2017-03-01 00:00:00

  • Computational analysis on the mechanical interaction between a thrombus and red blood cells: possible causes of membrane damage of red blood cells at microvessels.

    abstract::Previous studies investigating thrombus formation have not focused on the physical interaction between red blood cells (RBCs) and thrombus, although they have been speculated that some pathological conditions such as microangiopathic hemolytic anemia (MAHA) stem from interactions between RBCs and thrombi. In this stud...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.01.003

    authors: Kamada H,Imai Y,Nakamura M,Ishikawa T,Yamaguchi T

    更新日期:2012-12-01 00:00:00

  • Protocol development for synchrotron contrast-enhanced CT of human hip cartilage.

    abstract::Understanding hip osteoarthritis requires new investigational tools for quantitative studies of biophysical and biomechanical properties as well as for determination of structure. Three new protocols to study pathological changes in cartilage and to measure cartilage thickness in intact human hips are described using ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.08.003

    authors: Zhang H,Belev G,Stewart RC,Grinstaff MW,Snyder BD,Wilson DR

    更新日期:2019-11-01 00:00:00

  • A portable monitoring system for measuring weight-bearing during tibial fracture healing.

    abstract::An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal par...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00061-7

    authors: Aranzulla PJ,Muckle DS,Cunningham JL

    更新日期:1998-10-01 00:00:00

  • Sensitivity analysis of the position of the intervertebral centres of reaction in upright standing--a musculoskeletal model investigation of the lumbar spine.

    abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.003

    authors: Zander T,Dreischarf M,Schmidt H

    更新日期:2016-03-01 00:00:00

  • Mechanical behaviour of DNA molecules--elasticity and migration.

    abstract::A novel multi-scale simulation method developed to describe mesoscale phenomena occurring in biofluidic devices is presented. The approach combines the macro-scale modelling of the carrier fluid and the micro-scale description of the transported macromolecules or compounds. Application of the approach is demonstrated ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.003

    authors: Benke M,Shapiro E,Drikakis D

    更新日期:2011-09-01 00:00:00

  • Grasping soft tissue by means of vacuum technique.

    abstract:INTRODUCTION:A notable characteristic of bariatric surgery is the frequent manipulation of the bowel. The bowel is large, delicate, flexible, and has a natural lubricant on the tissue surface. Therefore the bowel is difficult to grasp and manipulate. Vacuum technique is commonly used in industry for all types of graspi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.014

    authors: Vonck D,Jakimowicz JJ,Lopuhaä HP,Goossens RH

    更新日期:2012-10-01 00:00:00

  • A microfluidic device for continuous manipulation of biological cells using dielectrophoresis.

    abstract::The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate no...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.010

    authors: Das D,Biswas K,Das S

    更新日期:2014-06-01 00:00:00

  • Quantitative characterisation of impaction events during femoral broaching in total hip arthroplasty.

    abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.12.004

    authors: Preutenborbeck M,Reuter J,Ferrari E

    更新日期:2020-02-01 00:00:00

  • Comparison of calibration methods for accelerometers used in human motion analysis.

    abstract::In the fields of medicine and biomechanics, MEMS accelerometers are increasingly used to perform activity recognition by directly measuring acceleration; to calculate speed and position by numerical integration of the signal; or to estimate the orientation of body parts in combination with gyroscopes. For some of thes...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2016.08.004

    authors: Nez A,Fradet L,Laguillaumie P,Monnet T,Lacouture P

    更新日期:2016-11-01 00:00:00

  • Effect of specimen length: are the mechanics of individual motion segments comparable in functional spinal units and multisegment specimens?

    abstract::Functional spinal units (FSUs) are frequently used for in vitro mechanical testing. This approach assumes that the mechanical behavior of the FSUs is equivalent to the mechanics of these segments within the intact spine. The purpose of this study was to determine whether normal spinal mechanics are compromised in FSU ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00152-2

    authors: Dickey JP,Kerr DJ

    更新日期:2003-04-01 00:00:00

  • Automated analysis of MR image of hip: geometrical evaluation of the Legg-Calve-Perthes disease.

    abstract::This study proposes semi-automatic determination of geometrical features in hip magnetic resonance (MR) images in order to evaluate the Legg-Calvé-Perthes disease (LCPD). Nine anatomical points on a hip image are selected by a clinician; then eight geometrical indexes of the hip joint are calculated: acetabulum head i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.10.003

    authors: Pouletaut P,Claude I,Winzenrieth R,Ho Ba Tho MC,Sebag G

    更新日期:2005-06-01 00:00:00

  • Suspension microarrays for the identification of the response patterns in hyperinflammatory diseases.

    abstract::Miniaturized and parallelized sandwich immunoassays allow the simultaneous analysis of a variety of parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. To study inflammatory diseases, protein arrays can be used to an...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.01.003

    authors: Hsu HY,Wittemann S,Schneider EM,Weiss M,Joos TO

    更新日期:2008-10-01 00:00:00

  • Automated robot-assisted assessment for wrist active ranges of motion.

    abstract::The measurement of wrist active range of motion (ROM) is essential for determining the progress of hand functional recovery, which can provide insight into quantitative improvements and enable effective monitoring during hand rehabilitation. Compared with manual methods, which depend on the experience of the therapist...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.003

    authors: Zhang M,McDaid A,Zhang S,Zhang Y,Xie SQ

    更新日期:2019-09-01 00:00:00