Protocol development for synchrotron contrast-enhanced CT of human hip cartilage.

Abstract:

:Understanding hip osteoarthritis requires new investigational tools for quantitative studies of biophysical and biomechanical properties as well as for determination of structure. Three new protocols to study pathological changes in cartilage and to measure cartilage thickness in intact human hips are described using synchrotron contrast enhanced computed tomography (sCECT) with the iodinated contrast agent CA4+. Ten human cadaver hips were prepared and injected with CA4+ using three different methods, all of which included rotation and distraction of the joint. CA4+ diffusion into cartilage was monitored using sCECT. The thickness of acetabular and femoral cartilage was also measured. Diffusion times ranged from 2 h to 75 h, depending on the injection protocol and the cartilage region. Direct single injection of the contrast through the labrum resulted in the fastest diffusion times. The iodine attenuation coefficient, which reflects the contrast agent distribution in the cartilage, ranged from 0.0142/cm to 0.1457/cm. Three injections at the head/neck conjunction area yielded the highest iodine attenuation coefficients in cartilage. The femoral cartilage in the Superior-Medial compartment was significantly thicker than in the other 3 femoral compartments, and femoral cartilage in the Superior-Anterior compartment was significantly thinner than the other 3 femoral compartments. The acetabular cartilage in the Superior compartment was significantly thicker than that in the Superior-Posterior compartment. sCECT with CA4+ allows assessment of hip cartilage thickness with 0.1 mm isotropic voxel size, sufficient for evaluating cartilage pathology and biomechanics.

journal_name

Med Eng Phys

authors

Zhang H,Belev G,Stewart RC,Grinstaff MW,Snyder BD,Wilson DR

doi

10.1016/j.medengphy.2019.08.003

subject

Has Abstract

pub_date

2019-11-01 00:00:00

pages

1-8

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(19)30158-4

journal_volume

73

pub_type

杂志文章
  • Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis.

    abstract::The biomechanical strength of the skeleton, and hence the risk of future fractures, depends on both the bone quantity (assessed in terms of bone mineral density) and bone quality (assessed in terms of the integrity of its internal architecture). Precise methods of measuring the calcium-equivalent density of both the t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(96)00011-2

    authors: Dougherty G

    更新日期:1996-10-01 00:00:00

  • On the secondary stability of coated cementless hip replacement: parameters that affected interface strength.

    abstract::Unlike primary stability of coated cementless implants, their secondary stability has been poorly studied. This paper considers some theoretical aspects of the secondary stability of a coated cementless hip implant in a human femur. The bone is separated from the implant by a thin layer of microscopic peaks and trough...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00099-7

    authors: Orlik J,Zhurov A,Middleton J

    更新日期:2003-12-01 00:00:00

  • A portable monitoring system for measuring weight-bearing during tibial fracture healing.

    abstract::An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal par...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00061-7

    authors: Aranzulla PJ,Muckle DS,Cunningham JL

    更新日期:1998-10-01 00:00:00

  • Validated computational framework for efficient systematic evaluation of osteoporotic fracture fixation in the proximal humerus.

    abstract::The high rate of fixation failure in osteoporotic proximal humerus fractures indicate the need for improved solutions. Computer simulations may help to overcome the limitations of the gold standard biomechanical testing in evaluating the performance of new implants and enhance the effectivity and outcome of the design...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.04.011

    authors: Varga P,Inzana JA,Gueorguiev B,Südkamp NP,Windolf M

    更新日期:2018-07-01 00:00:00

  • Physiological simulation of blood flow in the aorta: comparison of hemodynamic indices as predicted by 3-D FSI, 3-D rigid wall and 1-D models.

    abstract::Interest in patient-specific blood-flow circulation modeling has increased substantially in recent years. The availability of clinical data for geometric and elastic properties together with efficient numerical methods has now made model rendering feasible. This work uses 3-D fluid-structure interaction (FSI) to provi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.009

    authors: Reymond P,Crosetto P,Deparis S,Quarteroni A,Stergiopulos N

    更新日期:2013-06-01 00:00:00

  • Robust infrarenal aortic aneurysm lumen centerline detection for rupture status classification.

    abstract::The objective of this work is to develop a robust method for human abdominal aortic aneurysm (AAA) centerline detection that can contribute to the accurate computation of features for the prediction of AAA rupture risk. A semiautomatic algorithm is proposed for detecting the lumen centerline in contrast-enhanced abdom...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.005

    authors: Zhang H,Kheyfets VO,Finol EA

    更新日期:2013-09-01 00:00:00

  • Implementation of a PC-based integrated control system for children.

    abstract::Children with severe physical disabilities often require a range of technological devices to aid them with the fundamental tasks carried out in everyday life. These tasks areas may include mobility, communication, environment control and computer access for education. The most efficient, and often the most cost-effect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90043-4

    authors: Hawley MS,Cudd PA,Cherry AD

    更新日期:1994-05-01 00:00:00

  • Assessment of four statistical pattern recognition techniques to assist in obstructive sleep apnoea diagnosis from nocturnal oximetry.

    abstract::The aim of this study is to assess the utility of traditional statistical pattern recognition techniques to help in obstructive sleep apnoea (OSA) diagnosis. Classifiers based on quadratic (QDA) and linear (LDA) discriminant analysis, K-nearest neighbours (KNN) and logistic regression (LR) were evaluated. Spectral and...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.05.010

    authors: Marcos JV,Hornero R,Alvarez D,del Campo F,Zamarrón C

    更新日期:2009-10-01 00:00:00

  • Numerical analysis and experimental observation of guidewire motion in a blood vessel model.

    abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.012

    authors: Takashima K,Tsuzuki S,Ooike A,Yoshinaka K,Yu K,Ohta M,Mori K

    更新日期:2014-12-01 00:00:00

  • Development of tissue adhesion method using integrated low-level energies.

    abstract::We have developed a method that allows biological tissues to be adhered together with minimal invasion by delivering integrated low-level energies from heat, pressure, and vibration. Tensile tests on adhered slices of porcine aorta were performed to determine the relationships between adhesive strength and conditions ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.12.005

    authors: Katoh A,Masuzawa T,Ozeki K,Kishida A,Kimura T,Higami T

    更新日期:2010-05-01 00:00:00

  • Ultrasonography and electromyography based hand motion intention recognition for a trans-radial amputee: A case study.

    abstract::Surface electromyography (sEMG) has dominated upper-limb prosthesis control for decades due to its simplicity and effectiveness [1-3]. However, the inherent variability of EMG signal hinders the flexible and accurate control of advanced multi-functional prosthesis. This study is an attempt to use ultrasonography (US) ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.005

    authors: Wang Z,Fang Y,Zhou D,Li K,Cointet C,Liu H

    更新日期:2020-01-01 00:00:00

  • Effects of a multi-sensory environment on brain-injured patients: assessment of spectral patterns.

    abstract::Snoezelen(®) multi-sensory (SMS) environment has been commonly applied as a therapeutic strategy to alleviate the symptoms associated to a wide variety of pathologies. Despite most studies have reported a wide range of positive revealed short-term changes associated to SMS intervention, little has been done to systema...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.001

    authors: Poza J,Gómez C,Gutiérrez MT,Mendoza N,Hornero R

    更新日期:2013-03-01 00:00:00

  • Multispectral characterization of tissues encountered during laparoscopic colorectal surgery.

    abstract:AIMS:This study investigated the feasibility of automated differentiation between essential tissue types encountered during laparoscopic colorectal surgery using spectral analysis. METHODS:Wide band (440-1830 nm) spectra were collected using an optical fiber probe and spectrometer from freshly explanted, ex vivo, huma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.01.004

    authors: Schols RM,Dunias P,Wieringa FP,Stassen LP

    更新日期:2013-07-01 00:00:00

  • Baseline drift removal and denoising of MCG data using EEMD: role of noise amplitude and the thresholding effect.

    abstract::We adopt the Ensemble Empirical Mode Decomposition (EEMD) method, with an appropriate thresholding on the Intrinsic Mode Functions (IMFs), to denoise the magnetocardiography (MCG) signal. To this end, we discuss the two associated problems that relate to: (i) the amplitude of noise added to the observed signal in the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.023

    authors: Mariyappa N,Sengottuvel S,Parasakthi C,Gireesan K,Janawadkar MP,Radhakrishnan TS,Sundar CS

    更新日期:2014-10-01 00:00:00

  • Development and evaluation of a semi-automatic technique for determining the bilateral symmetry plane of the facial skeleton.

    abstract::During reconstructive surgery of the face, one side may be used as a template for the other, exploiting assumed bilateral facial symmetry. The best method to calculate this plane, however, is debated. A new semi-automatic technique for calculating the symmetry plane of the facial skeleton is presented here that uses s...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.06.006

    authors: Willing RT,Roumeliotis G,Jenkyn TR,Yazdani A

    更新日期:2013-12-01 00:00:00

  • Mechanical performance of Anatomic-Functional-Geometry dental treatments: A computational study.

    abstract::In this paper the biomechanical response of a novel dental preparation technique, referred to as the Anatomic-Functional-Geometry treatment (AFG), is investigated through a 3D nonlinear finite-element modelling approach. A comparative investigation against a standard technique employed in dental clinical practice is c...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.10.016

    authors: Gaziano P,Lorenzi C,Bianchi D,Monaldo E,Dolci A,Vairo G

    更新日期:2020-12-01 00:00:00

  • MRI/SPECT-based diagnosis and CT-guided high-intensity focused-ultrasound treatment system in MPTP mouse model of Parkinson's disease.

    abstract::Single-photon emission computed tomography (SPECT) of dopamine transporters with (99m)Tc-TRODAT-1 has recently been proposed to offer valuable information for the diagnosis of Parkinson's disease (PD). Furthermore, High-intensity focused ultrasound (HIFU) is a newly developed technique in which the energy of ultrasoun...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.01.006

    authors: Lee JD,Huang CH,Yang ST,Chu YH,Shieh YY,Chen JW,Lin KJ

    更新日期:2013-02-01 00:00:00

  • Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.

    abstract::Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the poss...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.010

    authors: Fan Z,Liu X,Sun A,Zhang N,Fan Z,Fan Y,Deng X

    更新日期:2017-10-01 00:00:00

  • In vivo estimation of normal left ventricular stiffness and contractility based on routine cine MR acquisition.

    abstract::Post-myocardial infarction remodeling process is known to alter the mechanical properties of the heart. Biomechanical parameters, such as tissue stiffness and contractility, would be useful for clinicians to better assess the severity of the diseased heart. However, these parameters are difficult to obtain in the curr...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.09.003

    authors: Rumindo GK,Ohayon J,Croisille P,Clarysse P

    更新日期:2020-11-01 00:00:00

  • Stress free configuration of the human eye.

    abstract::Numerical simulations of eye globes often rely on topographies that have been measured in vivo using devices such as the Pentacam or OCT. The topographies, which represent the form of the already stressed eye under the existing intraocular pressure, introduce approximations in the analysis. The accuracy of the simulat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.09.006

    authors: Elsheikh A,Whitford C,Hamarashid R,Kassem W,Joda A,Büchler P

    更新日期:2013-02-01 00:00:00

  • Fluid pressure driven fibril reinforcement in creep and relaxation tests of articular cartilage.

    abstract::Biological tissues exhibit diverse mechanical behaviors because of complex material properties. As has been shown for ligaments and intervertebral discs, mathematical models often appear to well predict load responses individually by adjusting model parameters, but likely fail to describe several different load respon...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.03.001

    authors: Li LP,Korhonen RK,Iivarinen J,Jurvelin JS,Herzog W

    更新日期:2008-03-01 00:00:00

  • Development of a small wireless device for perspiration monitoring.

    abstract::A small and wireless device that can capture the temporal pattern of perspiration by a novel structure of water vapor collection combined with reusable desiccant has been developed. The novel device consists of a small cylindrical case with a temperature/relative humidity sensor, battery-driven data logger, and silica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.009

    authors: Ogai K,Fukuoka M,Kitamura K,Uchide K,Nemoto T

    更新日期:2016-04-01 00:00:00

  • Optimised analytical models of the dielectric properties of biological tissue.

    abstract::The interaction of electromagnetic fields with the human body is quantified by the dielectric properties of biological tissues. These properties are incorporated into complex numerical simulations using parametric models such as Debye and Cole-Cole, for the computational investigation of electromagnetic wave propagati...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.01.017

    authors: Salahuddin S,Porter E,Krewer F,O' Halloran M

    更新日期:2017-05-01 00:00:00

  • Reliability, validity, and precision of an active stereophotogrammetry system for three-dimensional evaluation of the human torso.

    abstract::To determine the reliability, stability, validity and precision of a stereophotogrammetry (SP) system for use in quantifying the complex three-dimensional structure of the human torso, we performed assessments of the system using images of geometric solids and a human-form mannequin. Analysis of geometric solids revea...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.011

    authors: Paul SM,Chamberlin AP,Hatt C,Nayak AV,Danoff JV

    更新日期:2009-12-01 00:00:00

  • Real time monitoring of muscular fatigue from dynamic surface myoelectric signals using a complex covariance approach.

    abstract::A method aimed at the real-time monitoring of muscular fatigue was implemented and optimized. The method is based on an estimate of the complex covariance function in order to evaluate, in real time, the mean frequency of the myoelectric signal spectrum. Real-time implementation is guaranteed by a recursive computatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00049-1

    authors: Conforto S,D'Alessio T

    更新日期:1999-05-01 00:00:00

  • Minimal haemodynamic system model including ventricular interaction and valve dynamics.

    abstract::Characterising circulatory dysfunction and choosing a suitable treatment is often difficult and time consuming, and can result in a deterioration in patient condition, or unsuitable therapy choices. A stable minimal model of the human cardiovascular system (CVS) is developed with the ultimate specific aim of assisting...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2003.10.001

    authors: Smith BW,Chase JG,Nokes RI,Shaw GM,Wake G

    更新日期:2004-03-01 00:00:00

  • Comparison of different methods for the determination of the true wave propagation coefficient, in rubber tubes and the canine thoracic aorta.

    abstract::The results from studies of wave propagation in large arteries carried out over the last 25 years have shown that there is a good agreement among values of the imaginary part of the complex propagation coefficient, as expressed by pressure or flow-rate wave propagation velocity. However, there is considerable disparit...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00073-2

    authors: Bertram CD,Gow BS,Greenwald SE

    更新日期:1997-04-01 00:00:00

  • Enabling variable-stiffness hand rehabilitation orthoses with dielectric elastomer transducers.

    abstract::Patients affected by motor disorders of the hand and having residual voluntary movements of fingers or wrist can benefit from self-rehabilitation exercises performed with so-called dynamic hand splints. These systems consist of orthoses equipped with elastic cords or springs, which either provide a sustained stretch o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.10.015

    authors: Carpi F,Frediani G,Gerboni C,Gemignani J,De Rossi D

    更新日期:2014-02-01 00:00:00

  • The formation and function of the sclerosis rim in the femoral head: A biomechanical point of view.

    abstract::Sclerosis rim surrounding the necrotic area is commonly found in necrotic femoral head, but the biomechanical function of sclerosis rim has received relatively little attention. Little is known about the formation and natural history of sclerosis rim. In the present work, we assume that the necrotic change may trigger...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.09.005

    authors: Chen Z,Xu Y,Qi Z,Zho J

    更新日期:2015-12-01 00:00:00

  • A non-invasive Cochlear Microphonic measurement system.

    abstract::The Cochlear Microphonic is one of the electrical potentials generated by the ear in response to audible stimuli. It is very difficult to measure the CM non-invasively because it has a very small magnitude (less than 1 μV). A high Common Mode Rejection Ratio (CMRR) and very large bandwidth (5 Hz-20 kHz) biomedical amp...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.017

    authors: Masood A,Teal PD,Hollitt C

    更新日期:2012-10-01 00:00:00