Abstract:
:Interest in patient-specific blood-flow circulation modeling has increased substantially in recent years. The availability of clinical data for geometric and elastic properties together with efficient numerical methods has now made model rendering feasible. This work uses 3-D fluid-structure interaction (FSI) to provide physiological simulation resulting in modeling with a high level of detail. Comparisons are made between results using FSI and rigid wall models. The relevance of wall compliance in determining parameters of clinical importance, such as wall shear stress, is discussed together with the significance of differences found in the pressure and flow waveforms when using the 1-D model. Patient-specific geometry of the aorta and its branches was based on MRI angiography data. The arterial wall was created with a variable thickness. The boundary conditions for the fluid domain were pressure waveform at the ascending aorta and flow for each outlet. The waveforms were obtained using a 1-D model validated by in vivo measurements performed on the same person. In order to mimic the mechanical effect of surrounding tissues in the simulation, a stress-displacement relation was applied to the arterial wall. The temporal variation and spatial patterns of wall shear stress are presented in the aortic arch and thoracic aorta together with differences using rigid wall and FSI models. A comparison of the 3-D simulations to the 1-D model shows good reproduction of the pressure and flow waveforms.
journal_name
Med Eng Physjournal_title
Medical engineering & physicsauthors
Reymond P,Crosetto P,Deparis S,Quarteroni A,Stergiopulos Ndoi
10.1016/j.medengphy.2012.08.009subject
Has Abstractpub_date
2013-06-01 00:00:00pages
784-91issue
6eissn
1350-4533issn
1873-4030pii
S1350-4533(12)00222-6journal_volume
35pub_type
杂志文章abstract::Electromyography (EMG) has been widely used for the assessment of musculoskeletal functions and the control of electrical prostheses, which make use of the EMG signal generated by the contraction of the residual muscles. In spite of the successful applications of EMG in different fields, it has some inherent limitatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2005.07.012
更新日期:2006-06-01 00:00:00
abstract::Contamination of EEG signals by artefacts arising from head movements has been a serious obstacle in the deployment of automatic neurological event detection systems in ambulatory EEG. In this paper, we present work on categorizing these head-movement artefacts as one distinct class and on using support vector machine...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2012.08.017
更新日期:2013-07-01 00:00:00
abstract::Apparatus has been built to explore the practical feasibility of using automatic control with electrical stimulation of paralysed legs to restore function. The experiments are performed with paraplegics with the aim of achieving a realistic postural task: to see whether the body may be maintained upright by stimulatio...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(97)00020-9
更新日期:1997-09-01 00:00:00
abstract::A flow model utilizing an irrotational, inviscid algorithm of vortex-ring elements simulating the leaflets and source/sink elements simulating the aortic root coupled with a boundary layer model has been developed to model the internal flow phenomena of bi-leaflet mechanical heart valves implanted in the aortic root. ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00075-5
更新日期:1996-09-01 00:00:00
abstract::Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). Th...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.05.002
更新日期:2016-09-01 00:00:00
abstract::Biodegradable materials have been generating increasing bit of interest in biomedical applications and associated research. The evolution of implants made up of such materials (Mg-alloys, etc.) has the potential to be a game changer in fracture surgeries. These implants are essentially made up of a plate and a number ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.05.010
更新日期:2020-07-01 00:00:00
abstract::Results of a comparative analysis between Heart Rate (HR) patterns occurring before the onset of Paroxysmal Ventricular Tachycardia (PVT) and from healthy subjects are shown. Two study groups were made after electrocardiographic dynamical monitoring (Holter) of volunteers. The first group includes 100h from 27 healthy...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.08.004
更新日期:2010-12-01 00:00:00
abstract::This paper introduces a transcutaneous electro-muscle stimulator design that has a wide range of output capabilities. Because of this, the unit is referred to as a robust transcutaneous electro-muscle stimulator (RTES). The RTES is a constant current stimulator that is designed to be capable of generating significant ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)90857-8
更新日期:1995-06-01 00:00:00
abstract::A field-usable sleepiness tester could reduce sleepiness related accidents. 15 subjects' postural steadiness was measured with a Nintendo(®) Wii Fit balance board every hour for 24 h. Body sway was quantified with complexity index, CI, and the correlation between CI and alertness predicted by a three-process model of ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2013.08.007
更新日期:2013-12-01 00:00:00
abstract::Accurate models of bone shapes are essential for orthopaedic reconstructions. The commonly used methods of using the contralateral side requires an intact bone and anatomical symmetry. Recent studies have shown that statistical shape and appearance models (SSAMs) as an alternative can predict accurate geometric models...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.03.007
更新日期:2019-05-01 00:00:00
abstract::This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) co...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2010.05.007
更新日期:2010-10-01 00:00:00
abstract::Electrical impedance 'LX' waveforms measured across the neck at the thyroid level during phonation are known to be correlated with vocal fold movement. Changes in vocal fold contact are thought to be the cause of this phenomenon though emerging applications in radiotherapy indicate that changes in the configuration of...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(02)00065-6
更新日期:2002-09-01 00:00:00
abstract::The purpose of this study was to determine the use and feasibility of accelerometry-based monitoring and to examine a discrete multi-resolution signal analysis technique to determine motoric subtypes in patients with DSM-IV delirium. Forty consecutive patients receiving palliative care (23 male, 17 female, mean age+/-...
journal_title:Medical engineering & physics
pub_type: 临床试验,杂志文章
doi:10.1016/j.medengphy.2009.10.012
更新日期:2010-03-01 00:00:00
abstract::Since direct manual tissue palpation is not possible in laparoscopic surgery, feedback information on tactile tissue properties is considerably diminished. Restoring part of the surgeon's sense of touch through devices capable of providing artificial tactile feedback (ATF) is an active field of applied research and de...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2009.06.003
更新日期:2009-10-01 00:00:00
abstract::The high rate of fixation failure in osteoporotic proximal humerus fractures indicate the need for improved solutions. Computer simulations may help to overcome the limitations of the gold standard biomechanical testing in evaluating the performance of new implants and enhance the effectivity and outcome of the design...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2018.04.011
更新日期:2018-07-01 00:00:00
abstract::Pedicle screw loosening is still observed in clinical practice. Therefore, the understanding of the interaction between screw and bone is evermore subject of research. However, complex relationships between screw design and anchorage are rarely examined. For this reason, it is investigated whether screw fixation is pr...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.03.001
更新日期:2020-05-01 00:00:00
abstract::Metal plates are commonly used in the operative treatment of bone fractures. Rigid metal plates stabilize the fracture site, maintain good contact between bone fragments and allow early weight bearing and patient mobility. However, treatment with rigid metal plates can cause localized bone atrophy due to stress-shield...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/1350-4533(95)00041-0
更新日期:1996-04-01 00:00:00
abstract::Neointimal hyperplasia (NIH) is a major obstacle to graft patency in the peripheral arteries. A complex interaction of biomechanical factors contribute to NIH development and progression, and although haemodynamic markers such as wall shear stress have been linked to the disease, these have so far been insufficient to...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.09.011
更新日期:2019-12-01 00:00:00
abstract::Compared to conventional deep brain stimulation (DBS) for patients with Parkinson's Disease (PD), the newer approach of adaptive DBS (aDBS), regulating stimulation on the basis of the patient's clinical state, promises to achieve better clinical outcomes, avoid adverse-effects and save time for tuning parameters. A re...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.02.007
更新日期:2016-05-01 00:00:00
abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2014.09.012
更新日期:2014-12-01 00:00:00
abstract::Fetal movement is one index of fetal well-being. We designed and built a new recorder based on fetal movement acceleration measurement (FMAM). The FMAM recorder has a newly developed, capacitive acceleration sensor that can detect the oscillations of the maternal abdominal wall caused by fetal movements. In this study...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.09.001
更新日期:2012-06-01 00:00:00
abstract::Somatosensory evoked potential (SEP) testing has been widely applied to diagnosis of various neurological disorders. However, SEP recorded using surface electrodes is buried in noises, which makes the signal-to-noise ratio (SNR) very poor. Conventional averaging method usually requires up to thousands of raw SEP input...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2004.09.007
更新日期:2005-04-01 00:00:00
abstract::There are several issues attributed with abdominal aortic aneurysm endovascular repair. The positioning of bifurcated stent-grafts (SG) may affect SG hemodynamics. The hemodynamics and geometrical parameters of crossing or non-crossing graft limbs have not being totally accessed. Eight patient-specific SG devices and ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2016.09.011
更新日期:2016-12-01 00:00:00
abstract::Lateral epicondylitis (LE) is hypothesized to occur as a result of repetitive, strenuous and abnormal postural activities of the elbow and wrist. There is still a lack of understanding of how wrist and forearm positions contribute to this condition during common manual tasks. In this study the wrist kinematics and the...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.02.002
更新日期:2011-07-01 00:00:00
abstract::For many decades correlation and power spectrum have been primary tools for digital signal processing applications in the biomedical area. The information contained in the power spectrum is essentially that of the autocorrelation sequence; which is sufficient for complete statistical descriptions of Gaussian signals o...
journal_title:Medical engineering & physics
pub_type: 杂志文章,评审
doi:10.1016/j.medengphy.2010.04.009
更新日期:2010-09-01 00:00:00
abstract::To determine the reliability, stability, validity and precision of a stereophotogrammetry (SP) system for use in quantifying the complex three-dimensional structure of the human torso, we performed assessments of the system using images of geometric solids and a human-form mannequin. Analysis of geometric solids revea...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2009.08.011
更新日期:2009-12-01 00:00:00
abstract::Quantification in clinical, diagnostic electromyography (EMG) currently includes motor unit action potential (MUAP) analysis and interference pattern analysis. Early efforts to examine the frequency/power spectra of the interference pattern showed modest value but the technique was not developed further. This paper re...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2011.07.017
更新日期:2012-03-01 00:00:00
abstract::Observational balance tests (e.g., Berg Balance Scale) are used to evaluate fall-risk. However, they tend to be subjective, and their reliability and sensitivity can be limited. The use of in-lab equipment for objective balance evaluation has not been common in clinical practice, due to the requirement of an equipped ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2019.10.018
更新日期:2020-03-01 00:00:00
abstract::The Fit4Purpose project aims to develop upper limb prosthetic devices which are suitable for deployment in lower- and middle-income countries (LMIC's). Open-frame trans-radial socket designs are being considered, formed of several, linked components, including pads which interface directly with the skin surface. A mec...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/j.medengphy.2020.08.003
更新日期:2020-10-01 00:00:00
abstract::This study presents a theoretical model of the general stress state found in helical implantable leads in bending. The model accurately predicts stress in large filarity coils made from clad wire. The stress is predicted using flexural rigidity of the coil and is developed to include the effects of coil pitch and the ...
journal_title:Medical engineering & physics
pub_type: 杂志文章
doi:10.1016/s1350-4533(96)00022-7
更新日期:1997-10-01 00:00:00