Design of a biodegradable plate for femoral shaft fracture fixation.

Abstract:

:Biodegradable materials have been generating increasing bit of interest in biomedical applications and associated research. The evolution of implants made up of such materials (Mg-alloys, etc.) has the potential to be a game changer in fracture surgeries. These implants are essentially made up of a plate and a number of screws. In orthopaedic applications, they offer the biggest advantage of complete degradation after successfully supporting the fractured bone for the desired period. They may provide some nutrients that accelerate the healing process while simultaneously ensuring adequate mechanical stability. This article essentially focuses on design of a biodegradable implant plate for femoral shaft fracture, taking into consideration the dimensional accuracy of the plate, uniform biodegradation rate and adequate mechanical stability of the plate across the entire process span. The design of a biodegradable implant plate and associated specified screws that support the plate, fitted over two segments for fixation of femoral shaft fracture, has been made on the basis of femur's standard dimensions, optimized plate dimensions and uniform biodegradation rate. A confirmation regarding the safe design of the implant plate is obtained through computational structural analysis. The implant plate design turns out to be safe at specific optimized dimensions for a human being weighing 80 Kg, at corresponding loading and boundary conditions. For average monthly degradation of the plate across a period of six months, the factor of safety comes out to be more than unity. The implant plate eventually goes through complete degradation 3-6 months after the completion of the healing process and this is where the plate thickness plays a significant role.

journal_name

Med Eng Phys

authors

Chandra G,Pandey A,Pandey S

doi

10.1016/j.medengphy.2020.05.010

subject

Has Abstract

pub_date

2020-07-01 00:00:00

pages

86-96

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(20)30074-6

journal_volume

81

pub_type

杂志文章
  • Number and localization of the implants for the fixed prosthetic reconstructions: on the strain in the anterior maxillary region.

    abstract::Resorption following tooth loss and poor bone quality affect the success of implants in the anterior maxilla. Inappropriate planning can cause implant loss and aesthetics problems that are difficult to resolve. There is a limited literature on the optimum number and location of implants in anterior maxilla for fabrica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.004

    authors: Bölükbaşı N,Yeniyol S

    更新日期:2015-04-01 00:00:00

  • Validation of a C2-C7 cervical spine finite element model using specimen-specific flexibility data.

    abstract::This study presents a specimen-specific C2-C7 cervical spine finite element model that was developed using multiblock meshing techniques. The model was validated using in-house experimental flexibility data obtained from the cadaveric specimen used for mesh development. The C2-C7 specimen was subjected to pure continu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.03.001

    authors: Kallemeyn N,Gandhi A,Kode S,Shivanna K,Smucker J,Grosland N

    更新日期:2010-06-01 00:00:00

  • Pre-planning of intramedullary nailing procedures: A methodology for predicting the position of the distal hole.

    abstract::Inserting the distal locking screws is a challenging step of the intramedullary nailing procedures due to the nail deformation that makes the proximally mounted targeting systems ineffective. A pre-planning methodology is proposed, based on an analytical model of the nail-bone construct, to predict the nail deformatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.012

    authors: Mortazavi J,Farahmand F,Behzadipour S,Yeganeh A

    更新日期:2019-12-01 00:00:00

  • Simulations to study spatial extent of stimulation and effect of electrode-tissue gap in subretinal implants.

    abstract::We present a finite element based simulation and analysis method to describe the spatial extent of stimulation and the effects of electrode-tissue interactions in subretinal prostheses. In particular, we estimate the threshold stimulation current needed to depolarise and evoke action potentials in the ganglion cells t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.01.015

    authors: Kasi H,Bertsch A,Guyomard JL,Kolomiets B,Picaud S,Pelizzone M,Renaud P

    更新日期:2011-07-01 00:00:00

  • Finite element analysis of side branch access during bifurcation stenting.

    abstract::Stent implantation has become a widely accepted endovascular intervention for the treatment of stenosed arteries. This minimally invasive technique has shown excellent results in unbranched arteries. However, stenting bifurcation lesions remains a challenge in coronary intervention as it is associated with a lower suc...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.11.013

    authors: Mortier P,De Beule M,Van Loo D,Verhegghe B,Verdonck P

    更新日期:2009-05-01 00:00:00

  • Implementation of a PC-based integrated control system for children.

    abstract::Children with severe physical disabilities often require a range of technological devices to aid them with the fundamental tasks carried out in everyday life. These tasks areas may include mobility, communication, environment control and computer access for education. The most efficient, and often the most cost-effect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90043-4

    authors: Hawley MS,Cudd PA,Cherry AD

    更新日期:1994-05-01 00:00:00

  • Acoustic power measurement of high-intensity focused ultrasound transducer using a pressure sensor.

    abstract::The acoustic power of high-intensity focused ultrasound (HIFU) is an important parameter that should be measured prior to each treatment to guarantee effective and safe outcomes. A new calibration technique was developed that involves estimating the pressure distribution, calculating the acoustic power using an underw...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.01.014

    authors: Zhou Y

    更新日期:2015-03-01 00:00:00

  • An automated ECG-artifact removal method for trunk muscle surface EMG recordings.

    abstract::This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) co...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.05.007

    authors: Mak JN,Hu Y,Luk KD

    更新日期:2010-10-01 00:00:00

  • Combining ultrasonic and computed tomography scanning to characterize mechanical properties of cancellous bone in necrotic human femoral heads.

    abstract::Image-based finite element modelling has been commonly used to determine the biomechanical behaviours of human femora, particularly for the diagnosis of femoral head necrosis. One of the fundamental aspects of biomechanical modelling is the relationship between bone density, which is obtained from images, and elastic ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.02.002

    authors: Yue Y,Yang H,Li Y,Zhong H,Tang Q,Wang J,Wang R,He H,Chen W,Chen D

    更新日期:2019-04-01 00:00:00

  • A computational model-based study on the exchangeability of hepatic venous pressure gradients measured in multiple hepatic veins.

    abstract::Hepatic venous pressure gradient (HVPG) is a hemodynamic index widely used for evaluating the severity of portal hypertension. Theoretically, HVPG can be measured in any of the three major (i.e., right, middle and left) hepatic veins (HVs); however, it remains unclear whether HVPGs measured in different HVs are exchan...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.07.022

    authors: Wang T,Liang F,Li L,Zhang W,Wang G,Wang J,Zhang C,Qi X

    更新日期:2020-10-01 00:00:00

  • Arbitrary waveform constant current stimulator for long-term wearable applications.

    abstract::Subsensory electrical noise stimulation has been shown to improve sensory perception in humans. However, the majority of this work has been limited to the laboratory due to unavailability of portable body-worn stimulators. In this paper, we present a robust and reliable stimulator, engineered for wearable applications...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.04.001

    authors: Breen PP,Serrador JM,Gargiulo GD

    更新日期:2019-06-01 00:00:00

  • Validation of computerized square-drawing based evaluation of motor function in patients with stroke.

    abstract::Human-administered clinical scales are commonly used for quantifying motor performance and determining the course of therapy in post-stroke individuals. Computerized methods aim to improve consistency, resolution and duration of patients' evaluation. The objective of this study was to test the validity of computerized...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.06.001

    authors: Isaković MS,Savić AM,Konstantinović LM,Popović MB

    更新日期:2019-09-01 00:00:00

  • Variation of the impact duration during the in vitro insertion of acetabular cup implants.

    abstract::The acetabular cup (AC) is an implant impacted into a bone cavity and used for hip prosthesis surgery. Initial stability of the AC is an important factor for long term surgical success. The aim of this study is to determine the variations of the impact duration during AC implant insertion. Twenty-two bone samples take...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.005

    authors: Mathieu V,Michel A,Flouzat Lachaniette CH,Poignard A,Hernigou P,Allain J,Haïat G

    更新日期:2013-11-01 00:00:00

  • Pre-surgical CT/FEA for craniofacial distraction: I. Methodology, development, and validation of the cranial finite element model.

    abstract::Recently, surgeons have begun to treat serious congenital craniofacial deformities including craniosynostoses with mechanical devices that gradually distract the skull. As a prospective means of treatment planning for such complex deformities, FE models derived from routine preoperative CT scans (CT/FEA) would provide...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00053-8

    authors: Remmler D,Olson L,Ekstrom R,Duke D,Matamoros A,Matthews D,Ullrich CG

    更新日期:1998-11-01 00:00:00

  • Identification of patients prone to hypotension during hemodialysis based on the analysis of cardiovascular signals.

    abstract::Intradialytic hypotension (IDH) is a major complication during hemodialysis treatment, and therefore it is highly desirable to identify, at an early stage during treatment, whether the patient is prone to IDH. Heart rate variability (HRV), blood pressure variability (BPV) and baroreflex sensitivity (BRS) were analyzed...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.10.003

    authors: Hernando D,Sörnmo L,Sandberg F,Laguna P,Llamedo M,Bailón R

    更新日期:2015-12-01 00:00:00

  • A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant.

    abstract::This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired wi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.006

    authors: Pan MC,Zhuang HB,Chen CS,Wu JW,Lee SY

    更新日期:2013-12-01 00:00:00

  • A microfluidic device for continuous manipulation of biological cells using dielectrophoresis.

    abstract::The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate no...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.010

    authors: Das D,Biswas K,Das S

    更新日期:2014-06-01 00:00:00

  • Wheelchair integrated occupant restraints: feasibility in frontal impact.

    abstract::Individuals often use their wheelchair as a motor vehicle seat when traveling in motor vehicles. The current use of fixed vehicle-mounted wheelchair occupant restraint systems (FWORSs) often results in poor belt fit and discomfort. Additionally, satisfaction, usability and usage rate of FWORSs during transit use are o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00082-0

    authors: VanRoosmalen L,Bertocci GE,Ha D,Karg P

    更新日期:2001-12-01 00:00:00

  • Cytoskeleton and plasma-membrane damage resulting from exposure to sustained deformations: A review of the mechanobiology of chronic wounds.

    abstract::The purpose of this review paper is to summarize the current knowledge on cell-scale mechanically-inflicted deformation-damage, which is at the frontier of cell mechanobiology and biomechanics science, specifically in the context of chronic wounds. The dynamics of the mechanostructure of cells and particularly, the da...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2016.05.014

    authors: Gefen A,Weihs D

    更新日期:2016-09-01 00:00:00

  • Reconstruction of proximal humeral fractures with a reduced number of screws and a reinforced bone substitute.

    abstract::Multi-fragmented fractures of the proximal humerus are difficult to treat, especially in the case of osteoporotic bone. Intra-operative risks include cartilage damage when inserting multiple screws. A common post-operative complication is distal-varus collapse of the head. The aim of this study was to investigate if a...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.06.002

    authors: Cristofolini L,Morellato K,Cavallo M,Guerra E

    更新日期:2020-08-01 00:00:00

  • A model of lung parenchyma stress relaxation using fractional viscoelasticity.

    abstract::Some pulmonary diseases and injuries are believed to correlate with lung viscoelasticity changes. Hence, a better understanding of lung viscoelastic models could provide new perspectives on the progression of lung pathology and trauma. In the presented study, stress relaxation measurements were performed to quantify r...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.05.003

    authors: Dai Z,Peng Y,Mansy HA,Sandler RH,Royston TJ

    更新日期:2015-08-01 00:00:00

  • Characterizing atypical patterns of Heart Rate before Paroxysmal Ventricular Tachycardia.

    abstract::Results of a comparative analysis between Heart Rate (HR) patterns occurring before the onset of Paroxysmal Ventricular Tachycardia (PVT) and from healthy subjects are shown. Two study groups were made after electrocardiographic dynamical monitoring (Holter) of volunteers. The first group includes 100h from 27 healthy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.004

    authors: Alvarez E,Jiménez J,Moleiro F,Rodríguez A

    更新日期:2010-12-01 00:00:00

  • Ultrasonography and electromyography based hand motion intention recognition for a trans-radial amputee: A case study.

    abstract::Surface electromyography (sEMG) has dominated upper-limb prosthesis control for decades due to its simplicity and effectiveness [1-3]. However, the inherent variability of EMG signal hinders the flexible and accurate control of advanced multi-functional prosthesis. This study is an attempt to use ultrasonography (US) ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.005

    authors: Wang Z,Fang Y,Zhou D,Li K,Cointet C,Liu H

    更新日期:2020-01-01 00:00:00

  • Determination of the position and orientation of artificial knee implants using markers embedded in a bone: preliminary in vitro experiments.

    abstract::This study describes the method of determination of the position and orientation of artificial knee implants using a single-plane radiograph. To simplify the 3D/2D matching problem, we proposed to use small markers embedded in a bone. From the image coordinates of markers, it is possible to estimate the position and o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00037-7

    authors: Imai S,Higashijima K,Ishida A,Fukuoka Y,Hoshino A,Minamitani H

    更新日期:2003-06-01 00:00:00

  • Evaluation of four blood pump geometries: fluorescent particle flow visualisation technique.

    abstract::Artificial blood pumps play an increasingly important role in the treatment of end-stage cardiac failure. The fluid dynamics of blood flow through such devices crucially affects their clinical effectiveness. Specifically, if the flow of blood stagnates or slowly re-circulates thrombus formation can occur and the avoid...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00023-0

    authors: Rose ML,Mackay TG,Wheatley DJ

    更新日期:2000-04-01 00:00:00

  • Model-based physiomarkers of cerebral hemodynamics in patients with mild cognitive impairment.

    abstract::In our previous studies, we have introduced model-based "functional biomarkers" or "physiomarkers" of cerebral hemodynamics that hold promise for improved diagnosis of early-stage Alzheimer's disease (AD). The advocated methodology utilizes subject-specific data-based dynamic nonlinear models of cerebral hemodynamics ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.025

    authors: Marmarelis VZ,Shin DC,Orme ME,Zhang R

    更新日期:2014-05-01 00:00:00

  • A new method of assessing the mechanical properties of patient support systems (PSS) using a phantom. A preliminary communication.

    abstract::Pressure ulcers are a major problem worldwide believed to affect over 5% of all hospital in-patients, and countless others in the community at large. Many types of Patient Support Systems (PSS) are sold as pressure ulcer prevention equipment, but no consensus exists as to their mechanical efficacy. The use of human vo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00053-3

    authors: Bain DS,Scales JT,Nicholson GP

    更新日期:1999-06-01 00:00:00

  • Can a 15m-overground wheelchair sprint be used to assess wheelchair-specific anaerobic work capacity?

    abstract:OBJECTIVE:To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint (WAnT). METHODS:Able-bodie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.003

    authors: van der Scheer JW,de Groot S,Vegter RJ,Veeger DH,van der Woude LH

    更新日期:2014-04-01 00:00:00

  • Classification of waist-acceleration signals in a continuous walking record.

    abstract::We attempted to distinguish walking on level ground from walking on a stairway using waist acceleration signals. A triaxial accelerometer was fixed to the subject's waist and the three acceleration signals were recorded by a portable data logger at a sampling rate of 256 Hz. Twenty healthy male subjects were asked to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00041-2

    authors: Sekine M,Tamura T,Togawa T,Fukui Y

    更新日期:2000-05-01 00:00:00

  • Development and assessment of a Microsoft Kinect based system for imaging the breast in three dimensions.

    abstract::Three-dimensional surface imaging technologies have been used in the planning and evaluation of breast reconstructive and cosmetic surgery. The aim of this study was to develop a 3D surface imaging system based on the Microsoft Kinect and assess the accuracy and repeatability with which the system could image the brea...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.018

    authors: Wheat JS,Choppin S,Goyal A

    更新日期:2014-06-01 00:00:00