Reconstruction of proximal humeral fractures with a reduced number of screws and a reinforced bone substitute.

Abstract:

:Multi-fragmented fractures of the proximal humerus are difficult to treat, especially in the case of osteoporotic bone. Intra-operative risks include cartilage damage when inserting multiple screws. A common post-operative complication is distal-varus collapse of the head. The aim of this study was to investigate if an Innovative technique (reduced number of screws and injection of a beta-TCP additivated partially resorbable cement) provides the same or better stability of the reconstructed head compared to the Standard technique (using more screws). A four-fragment fracture was simulated in six pairs of humeri, with partial removal of the cancellous bone to simulate osteoporotic "eggshell" defect. One humerus of each pair was repaired with a Standard (locking plate, 2 cortical and 6 locking screws), and the other with the Innovative technique (same plate, 2 cortical and only 3 locking screws, plus cement injection). The reconstructed specimens were subjected to a biomechanical test where a cyclic force of increasing amplitude was applied axially until failure. The Innovative reconstructions withstood a force 3.49 times larger than the contralateral Standard reconstructions before failure started. The maximum force before final collapse for the Innovative reconstructions was 4.24 times larger than the contralateral Standard reconstructions. These differences were statistically significant. The Innovative reconstructions, based on fewer screws and beta-TCP additivated acrylic cement, showed positive results, demonstrating better biomechanical properties compared to the Standard reconstructions. These laboratory findings, along with the advantages of a reduced number of screws, may help perform a surgically safer, and more effective procedure in osteoporotic patients.

journal_name

Med Eng Phys

authors

Cristofolini L,Morellato K,Cavallo M,Guerra E

doi

10.1016/j.medengphy.2020.06.002

subject

Has Abstract

pub_date

2020-08-01 00:00:00

pages

97-103

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(20)30093-X

journal_volume

82

pub_type

杂志文章
  • A novel, inexpensive and easy to use tendon clamp for in vitro biomechanical testing.

    abstract::Frozen clamps can hold tendons and ligaments tightly and transmit high loads, from 4 kN to 13 kN, without slippage, yet they are complex and expensive. The existing non-frozen serrated jaw clamp is simple to fabricate and use, but the maximal tensile force it can sustain is only about 2.5 kN, which is not enough in ma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.019

    authors: Shi D,Wang D,Wang C,Liu A

    更新日期:2012-05-01 00:00:00

  • Implementation of a PC-based integrated control system for children.

    abstract::Children with severe physical disabilities often require a range of technological devices to aid them with the fundamental tasks carried out in everyday life. These tasks areas may include mobility, communication, environment control and computer access for education. The most efficient, and often the most cost-effect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90043-4

    authors: Hawley MS,Cudd PA,Cherry AD

    更新日期:1994-05-01 00:00:00

  • Reliability, validity, and precision of an active stereophotogrammetry system for three-dimensional evaluation of the human torso.

    abstract::To determine the reliability, stability, validity and precision of a stereophotogrammetry (SP) system for use in quantifying the complex three-dimensional structure of the human torso, we performed assessments of the system using images of geometric solids and a human-form mannequin. Analysis of geometric solids revea...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.011

    authors: Paul SM,Chamberlin AP,Hatt C,Nayak AV,Danoff JV

    更新日期:2009-12-01 00:00:00

  • Multispectral classification techniques for terahertz pulsed imaging: an example in histopathology.

    abstract::Terahertz pulsed imaging is a spectroscopic imaging modality using pulses of electromagnetic radiation (100 GHz-10 THz), and there has been recent interest in studying biomedical specimens. It is usual to display parametric images derived from the measured pulses. In this work, classification was achieved by applying ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.02.011

    authors: Berry E,Handley JW,Fitzgerald AJ,Merchant WJ,Boyle RD,Zinov'ev NN,Miles RE,Chamberlain JM,Smith MA

    更新日期:2004-06-01 00:00:00

  • A complete, non-lumped, and verifiable set of upper body segment parameters for three-dimensional dynamic modeling.

    abstract::Dynamic models of the human trunk have been extensively used to investigate the biomechanics of lower back pain and postural instability in different populations. Despite their diverse applications, previous models rely on intrinsic upper body segment parameters (UBSP), e.g., each segment's mass-inertia characteristic...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.09.008

    authors: Vette AH,Yoshida T,Thrasher TA,Masani K,Popovic MR

    更新日期:2011-01-01 00:00:00

  • Comparison of algorithms to quantify muscle fatigue in upper limb muscles based on sEMG signals.

    abstract::This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.09.009

    authors: Kahl L,Hofmann UG

    更新日期:2016-11-01 00:00:00

  • Herringbone-like hydrodynamic structures in microchannels: A CFD model to evaluate the enhancement of surface binding.

    abstract::Selected adsorption efficiency of a molecule in solution in a microchannel is strongly influenced by the convective/diffusive mass transport phenomena that supply the target molecule to the adsorption surface. In a standard microchannel with a rectangular cross section, laminar flow regime limits the fluid mixing, thu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.07.003

    authors: Bianchi E,Piergiovanni M,Arrigoni C,Fukuda J,Gautieri A,Moretti M,Dubini G

    更新日期:2017-10-01 00:00:00

  • A method for determining the heat transfer and water vapour permeability of patient support systems.

    abstract::The formation of pressure ulcers can be exacerbated by a breakdown in the integrity of the patient's skin caused by poor maintenance of the skin microclimate. Patient support systems (PSSs-specialised beds, mattresses, chairs, cushions and pads) play an important role in the dissipation of heat and moisture away from ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00003-5

    authors: Nicholson GP,Scales JT,Clark RP,de Calcina-Goff ML

    更新日期:1999-12-01 00:00:00

  • Respiratory effort from the photoplethysmogram.

    abstract::The potential for a simple, non-invasive measure of respiratory effort based on the pulse oximeter signal - the photoplethysmogram or 'pleth' - was investigated in a pilot study. Several parameters were developed based on a variety of manifestations of respiratory effort in the signal, including modulation changes in ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.12.010

    authors: Addison PS

    更新日期:2017-03-01 00:00:00

  • Computational analysis on the mechanical interaction between a thrombus and red blood cells: possible causes of membrane damage of red blood cells at microvessels.

    abstract::Previous studies investigating thrombus formation have not focused on the physical interaction between red blood cells (RBCs) and thrombus, although they have been speculated that some pathological conditions such as microangiopathic hemolytic anemia (MAHA) stem from interactions between RBCs and thrombi. In this stud...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.01.003

    authors: Kamada H,Imai Y,Nakamura M,Ishikawa T,Yamaguchi T

    更新日期:2012-12-01 00:00:00

  • Significance of spine stability criteria on trunk muscle forces following unilateral muscle weakening: A comparison between kinematics-driven and stability-based kinematics-driven musculoskeletal models.

    abstract::Two optimization-driven approaches were employed to develop kinematics-driven (KD) and stability-based kinematics-driven (SKD) musculoskeletal models of an adult thoracolumbar to ascertain the significance of spine stability in holding the upright-standing posture after muscular disuse atrophy. Both models were used t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.008

    authors: Kamal Z,Rouhi G

    更新日期:2019-11-01 00:00:00

  • Optimised analytical models of the dielectric properties of biological tissue.

    abstract::The interaction of electromagnetic fields with the human body is quantified by the dielectric properties of biological tissues. These properties are incorporated into complex numerical simulations using parametric models such as Debye and Cole-Cole, for the computational investigation of electromagnetic wave propagati...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.01.017

    authors: Salahuddin S,Porter E,Krewer F,O' Halloran M

    更新日期:2017-05-01 00:00:00

  • A mathematical model of the impact response of the seated subject.

    abstract::A model of the lumbar spine, pelvis and buttocks is developed, based on linear horizontal and vertical systems along with a rotational subsystem. The model can mimic qualitatively different experimental observations of transmission of vibrations from the seat to L3 in the sitting posture. It is concluded that while th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00062-3

    authors: Broman H,Pope M,Hansson T

    更新日期:1996-07-01 00:00:00

  • New equations to calculate 3D joint centres in the lower extremities.

    abstract::Biomechanical movement analysis in 3D requires estimation of joint centres in the lower extremities and this estimation is based on extrapolation from markers placed on anatomical landmarks. The purpose of the present study was to quantify the accuracy of three established set of equations and provide new improved equ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.07.001

    authors: Sandau M,Heimbürger RV,Villa C,Jensen KE,Moeslund TB,Aanæs H,Alkjær T,Simonsen EB

    更新日期:2015-10-01 00:00:00

  • Technical quality evaluation of EEG recording based on electroencephalographers' knowledge.

    abstract::The aim of this study is to develop a technical quality evaluation system of electroencephalogram (EEG) recording in order to acquire technically satisfactory EEG records, which may contribute to the accuracy improvement of EEG interpretation. In our developed system, the evaluation of EEG recording comprises the dete...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.001

    authors: Nakamura M,Chen Q,Sugi T,Ikeda A,Shibasaki H

    更新日期:2005-01-01 00:00:00

  • Clinical relevance of augmented statistical shape model of the scapula in the glenoid region.

    abstract:OBJECTIVE:To illustrate (a) whether a statistical shape model (SSM) augmented with anatomical landmark set(s) performs better fitting and provides improved clinical relevance over non-augmented SSM and (b) which anatomical landmark set provides the best augmentation strategy for predicting the glenoid region of the sca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.007

    authors: Salhi A,Burdin V,Brochard S,Mutsvangwa TE,Borotikar B

    更新日期:2020-02-01 00:00:00

  • Quantitative characterisation of impaction events during femoral broaching in total hip arthroplasty.

    abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.12.004

    authors: Preutenborbeck M,Reuter J,Ferrari E

    更新日期:2020-02-01 00:00:00

  • Investigation to predict patellar tendon reflex using motion analysis technique.

    abstract::The investigation of patellar tendon reflex involves development of a reflex hammer holder, kinematic data collection and analysis of patellar reflex responses using motion analysis techniques. The main aim of this research is to explore alternative means of assessing reflexes as a part of routine clinical diagnosis. ...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.medengphy.2010.11.002

    authors: Tham LK,Osman NA,Lim KS,Pingguan-Murphy B,Abas WA,Zain NM

    更新日期:2011-05-01 00:00:00

  • A non-invasive Cochlear Microphonic measurement system.

    abstract::The Cochlear Microphonic is one of the electrical potentials generated by the ear in response to audible stimuli. It is very difficult to measure the CM non-invasively because it has a very small magnitude (less than 1 μV). A high Common Mode Rejection Ratio (CMRR) and very large bandwidth (5 Hz-20 kHz) biomedical amp...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.017

    authors: Masood A,Teal PD,Hollitt C

    更新日期:2012-10-01 00:00:00

  • Comparison of different methods for the determination of the true wave propagation coefficient, in rubber tubes and the canine thoracic aorta.

    abstract::The results from studies of wave propagation in large arteries carried out over the last 25 years have shown that there is a good agreement among values of the imaginary part of the complex propagation coefficient, as expressed by pressure or flow-rate wave propagation velocity. However, there is considerable disparit...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00073-2

    authors: Bertram CD,Gow BS,Greenwald SE

    更新日期:1997-04-01 00:00:00

  • Multispectral characterization of tissues encountered during laparoscopic colorectal surgery.

    abstract:AIMS:This study investigated the feasibility of automated differentiation between essential tissue types encountered during laparoscopic colorectal surgery using spectral analysis. METHODS:Wide band (440-1830 nm) spectra were collected using an optical fiber probe and spectrometer from freshly explanted, ex vivo, huma...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.01.004

    authors: Schols RM,Dunias P,Wieringa FP,Stassen LP

    更新日期:2013-07-01 00:00:00

  • Fluid pressure driven fibril reinforcement in creep and relaxation tests of articular cartilage.

    abstract::Biological tissues exhibit diverse mechanical behaviors because of complex material properties. As has been shown for ligaments and intervertebral discs, mathematical models often appear to well predict load responses individually by adjusting model parameters, but likely fail to describe several different load respon...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.03.001

    authors: Li LP,Korhonen RK,Iivarinen J,Jurvelin JS,Herzog W

    更新日期:2008-03-01 00:00:00

  • Reproducible metacarpal joint space width measurements using 3D analysis of images acquired with high-resolution peripheral quantitative computed tomography.

    abstract:OBJECTIVE:Joint space narrowing is an important feature of progressive joint damage and functional impairment in rheumatoid arthritis (RA). Methods to provide a continuous measurement of joint space width have not been adopted in research or clinical settings. High-resolution peripheral quantitative computed tomography...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.003

    authors: Barnabe C,Buie H,Kan M,Szabo E,Barr SG,Martin L,Boyd SK

    更新日期:2013-10-01 00:00:00

  • Evaluation of the magnitude of hip joint deformation in subjects with avascular necrosis of the hip joint during walking with and without Scottish Rite orthosis.

    abstract::The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influen...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.015

    authors: Karimi MT,Mohammadi A,Ebrahimi MH,McGarry A

    更新日期:2017-02-01 00:00:00

  • Sensorized pacifier to evaluate non-nutritive sucking in newborns.

    abstract::We developed a device for an objective measurement of non-nutritive sucking (NNS). NNS is newborns' spontaneous action that is a predictor of their neural system development and can be adopted as an intervention to train oral feeding skills in preterms. Two miniaturized digital pressure sensors were embedded into a co...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.013

    authors: Grassi A,Cecchi F,Sgherri G,Guzzetta A,Gagliardi L,Laschi C

    更新日期:2016-04-01 00:00:00

  • A markerless sub-pixel motion estimation technique to reconstruct kinematics and estimate the centre of mass in posturography.

    abstract::A novel method to evaluate postural sway is presented: balance strategies are identified by applying a markerless image processing algorithm to video sequences obtained from commercially available systems. The motion estimation technique for the analysis of video sequences is a coarse to fine procedure based on the bl...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.10.007

    authors: Goffredo M,Schmid M,Conforto S,D'Alessio T

    更新日期:2006-09-01 00:00:00

  • Automated robot-assisted assessment for wrist active ranges of motion.

    abstract::The measurement of wrist active range of motion (ROM) is essential for determining the progress of hand functional recovery, which can provide insight into quantitative improvements and enable effective monitoring during hand rehabilitation. Compared with manual methods, which depend on the experience of the therapist...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.07.003

    authors: Zhang M,McDaid A,Zhang S,Zhang Y,Xie SQ

    更新日期:2019-09-01 00:00:00

  • TETRA mobile radios interfere with electroencephalography recording equipment.

    abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.009

    authors: Fouquet NC,Hawken MB,Elliott P,Burgess AP

    更新日期:2013-11-01 00:00:00

  • Baseline drift removal and denoising of MCG data using EEMD: role of noise amplitude and the thresholding effect.

    abstract::We adopt the Ensemble Empirical Mode Decomposition (EEMD) method, with an appropriate thresholding on the Intrinsic Mode Functions (IMFs), to denoise the magnetocardiography (MCG) signal. To this end, we discuss the two associated problems that relate to: (i) the amplitude of noise added to the observed signal in the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.06.023

    authors: Mariyappa N,Sengottuvel S,Parasakthi C,Gireesan K,Janawadkar MP,Radhakrishnan TS,Sundar CS

    更新日期:2014-10-01 00:00:00

  • Evaluation of four blood pump geometries: fluorescent particle flow visualisation technique.

    abstract::Artificial blood pumps play an increasingly important role in the treatment of end-stage cardiac failure. The fluid dynamics of blood flow through such devices crucially affects their clinical effectiveness. Specifically, if the flow of blood stagnates or slowly re-circulates thrombus formation can occur and the avoid...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00023-0

    authors: Rose ML,Mackay TG,Wheatley DJ

    更新日期:2000-04-01 00:00:00