Characterizing atypical patterns of Heart Rate before Paroxysmal Ventricular Tachycardia.

Abstract:

:Results of a comparative analysis between Heart Rate (HR) patterns occurring before the onset of Paroxysmal Ventricular Tachycardia (PVT) and from healthy subjects are shown. Two study groups were made after electrocardiographic dynamical monitoring (Holter) of volunteers. The first group includes 100h from 27 healthy control subjects, and the second group consists of 88h, ending with self-terminating episodes of PVT from 55 patients. Patterns are defined as sequences of consecutive RR intervals, while atypical patterns are defined as corresponding to unlikely behavior of Heart Rate in healthy subjects. We investigated spatial and temporal distributions of these patterns in order to find early signs of PVT. We found that they can be grouped on a reduced number of clusters, and the number of atypical patterns increases as we approach the onset of the episode.

journal_name

Med Eng Phys

authors

Alvarez E,Jiménez J,Moleiro F,Rodríguez A

doi

10.1016/j.medengphy.2010.08.004

subject

Has Abstract

pub_date

2010-12-01 00:00:00

pages

1131-6

issue

10

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(10)00173-6

journal_volume

32

pub_type

杂志文章
  • In vivo estimation of normal left ventricular stiffness and contractility based on routine cine MR acquisition.

    abstract::Post-myocardial infarction remodeling process is known to alter the mechanical properties of the heart. Biomechanical parameters, such as tissue stiffness and contractility, would be useful for clinicians to better assess the severity of the diseased heart. However, these parameters are difficult to obtain in the curr...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.09.003

    authors: Rumindo GK,Ohayon J,Croisille P,Clarysse P

    更新日期:2020-11-01 00:00:00

  • Development and assessment of a Microsoft Kinect based system for imaging the breast in three dimensions.

    abstract::Three-dimensional surface imaging technologies have been used in the planning and evaluation of breast reconstructive and cosmetic surgery. The aim of this study was to develop a 3D surface imaging system based on the Microsoft Kinect and assess the accuracy and repeatability with which the system could image the brea...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.018

    authors: Wheat JS,Choppin S,Goyal A

    更新日期:2014-06-01 00:00:00

  • A practical technique for measuring human biofluid conductivity using high gain-frequency characteristics.

    abstract::Currently, the study of ion composition and performance in human biofluids plays an important role in biomedical engineering research and technology. This field may become universal for human diagnostics; it allows early detection of different diseases in humans by measuring changes in ion behaviour in human biofluids...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.04.007

    authors: Al-Nabulsi JI,Aloquili O,Ausheva V,Yuldashev ZM

    更新日期:2011-11-01 00:00:00

  • Cytoskeleton and plasma-membrane damage resulting from exposure to sustained deformations: A review of the mechanobiology of chronic wounds.

    abstract::The purpose of this review paper is to summarize the current knowledge on cell-scale mechanically-inflicted deformation-damage, which is at the frontier of cell mechanobiology and biomechanics science, specifically in the context of chronic wounds. The dynamics of the mechanostructure of cells and particularly, the da...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2016.05.014

    authors: Gefen A,Weihs D

    更新日期:2016-09-01 00:00:00

  • Quantitative characterisation of impaction events during femoral broaching in total hip arthroplasty.

    abstract::Total hip arthroplasty (THA) broaching involves impacting a broach handle with a mallet, facilitating force transmission to progress broaches into the femoral medullary canal. Limited surgical access during direct anterior THAs increases off-axis forces, potentially contributing to tissue damage. The aim was to charac...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.12.004

    authors: Preutenborbeck M,Reuter J,Ferrari E

    更新日期:2020-02-01 00:00:00

  • Attention attraction in an ophthalmic diagnostic device using sound-modulated fixation targets.

    abstract::This study relates to eye fixation systems with combined optical and audio systems. Many devices for eye diagnostics and some devices for eye therapeutics require the patient to fixate on a small target for a certain period of time, during which the eyes do not move and data from substructures of one or both eyes are ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.004

    authors: Gramatikov BI,Rangarajan S,Irsch K,Guyton DL

    更新日期:2016-08-01 00:00:00

  • Liquid ventilation: a mathematical model of gas diffusion in the premature lung.

    abstract::The liquid ventilation (LV) technique was previously demonstrated to be a valuable alternative to ordinary gas ventilation, particularly for newborn patients with severely distressed lungs. This work describes a mathematical model of gas transfer phenomena occurring within the lungs of a preterm newborn baby ventilate...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00041-0

    authors: Costantino ML,Fiore GB

    更新日期:1997-03-01 00:00:00

  • In-vitro validation of a non-invasive dual fluoroscopic imaging technique for measurement of the hip kinematics.

    abstract::Measurement of accurate in vivo hip joint kinematics in 6-DOF is difficult. Few studies have reported non-invasive measurements of the hip kinematics. The objective of this study was to validate a non-invasive dual fluoroscopic imaging system (DFIS) for measurement of hip kinematics. Bi-lateral hip joints of a cadaver...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.004

    authors: Lin H,Wang S,Tsai TY,Li G,Kwon YM

    更新日期:2013-03-01 00:00:00

  • An impedance sensor to monitor and control cerebral ventricular volume.

    abstract::This paper presents a sensor for monitoring and controlling the volume of the cerebrospinal fluid-filled ventricles of the brain. The measurement principle of the sensor exploits electrical conductivity differences between the cerebrospinal fluid and the brain tissue. The electrical contrast was validated using dog br...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.03.011

    authors: Linninger A,Basati S,Dawe R,Penn R

    更新日期:2009-09-01 00:00:00

  • Porcine carotid arterial material property alterations with induced atheroma: an in vivo study.

    abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.014

    authors: Nagaraj A,Kim H,Hamilton AJ,Mun JH,Smulevitz B,Kane BJ,Yan LL,Roth SI,McPherson DD,Chandran KB

    更新日期:2005-03-01 00:00:00

  • Biomechanical design using in-vitro finite element modeling of distal femur fracture plates made from semi-rigid materials versus traditional metals for post-operative toe-touch weight-bearing.

    abstract::This proof-of-concept study designs distal femur fracture plates from semi-rigid materials vs. traditional metals for toe-touch weight-bearing recommended to patients immediately after surgery. The two-fold goal was to (a) reduce stress shielding (SS) by increasing cortical bone stress thereby reducing the risk of bon...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.11.015

    authors: Gee A,Bougherara H,Schemitsch EH,Zdero R

    更新日期:2021-01-01 00:00:00

  • Pulsatile impeller heart: a viable alternative to a problematic diaphragm heart.

    abstract::The impeller blood pump with its simplicity has many advantages compared with the diaphragm pump, but the nonpulsatile property has limited its applications. To make the impeller pump pulsatile, many investigations have been made in vain because of resulting haemolysis. The author has succeeded in producing a pulsatil...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00010-0

    authors: Qian KX

    更新日期:1996-01-01 00:00:00

  • Mechanical properties of different airway stents.

    abstract::Airway stents improve pulmonary function and quality of life in patients suffering from airway obstruction. The aim of this study was to compare main types of stents (silicone, balloon-dilated metal, self-expanding metal, and covered self-expanding metal) in terms of their mechanical properties and the radial forces t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.008

    authors: Ratnovsky A,Regev N,Wald S,Kramer M,Naftali S

    更新日期:2015-04-01 00:00:00

  • Suspension microarrays for the identification of the response patterns in hyperinflammatory diseases.

    abstract::Miniaturized and parallelized sandwich immunoassays allow the simultaneous analysis of a variety of parameters in a single experiment. Bead-based protein array systems or suspension microarrays are well-established multiplex sandwich immunoassay formats. To study inflammatory diseases, protein arrays can be used to an...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2008.01.003

    authors: Hsu HY,Wittemann S,Schneider EM,Weiss M,Joos TO

    更新日期:2008-10-01 00:00:00

  • The effects of flute shape and thread profile on the insertion torque and primary stability of dental implants.

    abstract::Easy insertion of the implant and stable bone purchase is essential for an ideal dental implantation. At the implant tip, the cutting flutes and conical profile are respectively designed to reduce insertion resistance and facilitate the initial insertion. However, the tapered tip might reduce the self-tapping and bone...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.021

    authors: Wu SW,Lee CC,Fu PY,Lin SC

    更新日期:2012-09-01 00:00:00

  • Effects of cartilage rings on airflow and particle deposition in the trachea and main bronchi.

    abstract::In most computational fluid dynamic (CFD) analysis of the human lung, it has been assumed that the trachea and branches of the lung have smooth walls. In order to determine if this is a valid assumption, the effects of cartilage rings on airflow and particle deposition in the lungs was determined through conducting si...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.06.010

    authors: Russo J,Robinson R,Oldham MJ

    更新日期:2008-06-01 00:00:00

  • Flexible impulse transfer using a Newton's Cradle-inspired catheter: A feasibility study.

    abstract::A major challenge during minimally invasive surgery is transfer of high forces through small, flexible instruments, such as needles and catheters, because of their low buckling resistance. In this study, we determined the feasibility of using a Newton's Cradle-inspired catheter (patented) to transfer high-force impuls...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.12.025

    authors: Sakes A,Grandia L,Lether R,Steenstra L,Valentijn MC,Breedveld P,Spronck JW

    更新日期:2019-05-01 00:00:00

  • In vivo soft tissue damage assessment for applications in surgery.

    abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.04.002

    authors: Famaey N,Verbeken E,Vinckier S,Willaert B,Herijgers P,Vander Sloten J

    更新日期:2010-06-01 00:00:00

  • TETRA mobile radios interfere with electroencephalography recording equipment.

    abstract::We observed an anomaly in the human electroencephalogram (EEG) associated with exposure to terrestrial trunked radio (TETRA) Radiofrequency Fields (RF). Here, we characterize the time and frequency components of the anomaly and demonstrate that it is an artefact caused by TETRA RF interfering with the EEG recording eq...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.04.009

    authors: Fouquet NC,Hawken MB,Elliott P,Burgess AP

    更新日期:2013-11-01 00:00:00

  • A novel parameter for the prediction of pedicle screw fixation in cancellous bone - A biomechanical study on synthetic foam.

    abstract::Pedicle screw loosening is still observed in clinical practice. Therefore, the understanding of the interaction between screw and bone is evermore subject of research. However, complex relationships between screw design and anchorage are rarely examined. For this reason, it is investigated whether screw fixation is pr...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.03.001

    authors: Weidling M,Oefner C,Schoenfelder S,Heyde CE

    更新日期:2020-05-01 00:00:00

  • Human body model response to mechanical impulse.

    abstract::Despite our understanding of the importance of falling, previous studies have ignored the effects of falls from standing height. In this article, lumped parameter linear and nonlinear models of a standing human have been used to simulate the impact response of the body segments due to inputs at the shoes. The accelera...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00081-1

    authors: Jarrah M,Qassem W,Othman M,Gdeisat M

    更新日期:1997-06-01 00:00:00

  • Surgical instrumentation for the in vivo determination of human lumbar spinal segment stiffness and viscoelasticity.

    abstract::The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechan...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.07.002

    authors: Ambrosetti-Giudici S,Pfenniger A,Krenn MH,Piotrowski WP,Ferguson SJ,Burger J

    更新日期:2009-11-01 00:00:00

  • Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.

    abstract::Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the poss...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.010

    authors: Fan Z,Liu X,Sun A,Zhang N,Fan Z,Fan Y,Deng X

    更新日期:2017-10-01 00:00:00

  • Sensitivity analysis of the position of the intervertebral centres of reaction in upright standing--a musculoskeletal model investigation of the lumbar spine.

    abstract::The loads between adjacent vertebrae can be generalised as a single spatial force acting at the intervertebral centre of reaction. The exact position in vivo is unknown. However, in rigid body musculoskeletal models that simulate upright standing, the position is generally assumed to be located at the discs' centres o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.003

    authors: Zander T,Dreischarf M,Schmidt H

    更新日期:2016-03-01 00:00:00

  • Design and testing of a high-speed treadmill to measure ground reaction forces at the limit of human gait.

    abstract::Investigations focused on the gait and physiological limits of human speed have been on-going for more than a century. However, due to measurement limitation a kinetic understanding of the foot-ground collision and how these dynamics differ between individuals to confer speed and limit gait has only recently begun to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.04.009

    authors: Bundle MW,Powell MO,Ryan LJ

    更新日期:2015-09-01 00:00:00

  • Three-dimensional analysis and visualization of regional MR signal intensity distribution of articular cartilage.

    abstract::The aim of this study was to develop a technique for analyzing and visualizing the regional, three-dimensional signal intensity distribution of articular cartilage in MR images, as a potential surrogate marker of structural or biochemical alterations in early osteoarthritis. Exemplary MR-images of human patellae were ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00006-1

    authors: Hohe J,Faber S,Muehlbauer R,Reiser M,Englmeier KH,Eckstein F

    更新日期:2002-04-01 00:00:00

  • Low-level laser therapy using the minimally invasive laser needle system on osteoporotic bone in ovariectomized mice.

    abstract::This study tested the effectiveness of low-level laser therapy (LLLT) in preventing and/or treating osteoporotic trabecular bone. Mice were ovariectomized (OVX) to induce osteoporotic bone loss. The tibiae of eight OVX mice were treated for 5 days each week for 2 weeks by LLLT (660 nm, 3 J) using a minimally invasive ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.002

    authors: Ko CY,Kang H,Seo DH,Jung B,Schreiber J,Kim HS

    更新日期:2013-07-01 00:00:00

  • Pre-planning of intramedullary nailing procedures: A methodology for predicting the position of the distal hole.

    abstract::Inserting the distal locking screws is a challenging step of the intramedullary nailing procedures due to the nail deformation that makes the proximally mounted targeting systems ineffective. A pre-planning methodology is proposed, based on an analytical model of the nail-bone construct, to predict the nail deformatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.012

    authors: Mortazavi J,Farahmand F,Behzadipour S,Yeganeh A

    更新日期:2019-12-01 00:00:00

  • Genetic fuzzy modelling and control of bispectral index (BIS) for general intravenous anaesthesia.

    abstract::Based on an adaptive genetic fuzzy clustering algorithm, a derived fuzzy knowledge model is proposed for quantitatively estimating the systolic arterial pressure (SAP), heart rate (HR), and bispectral index (BIS) using 12 patients and it validates them according to pharmacological reasoning. Also, a genetic proportion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.medengphy.2005.04.023

    authors: Shieh JS,Kao MH,Liu CC

    更新日期:2006-03-01 00:00:00

  • Gabor frames for classification of paroxysmal and persistent atrial fibrillation episodes.

    abstract::In this study, we propose a new classification method for early differentiation of paroxysmal and persistent atrial fibrillation episodes, i.e. those which spontaneously or with external intervention will return to sinus rhythm within 7 days of onset from the ones where the arrhythmia is sustained for more than 7 days...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.013

    authors: Ortigosa N,Galbis A,Fernández C,Cano Ó

    更新日期:2017-01-01 00:00:00