Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis.

Abstract:

:The biomechanical strength of the skeleton, and hence the risk of future fractures, depends on both the bone quantity (assessed in terms of bone mineral density) and bone quality (assessed in terms of the integrity of its internal architecture). Precise methods of measuring the calcium-equivalent density of both the trabecular and cortical components of vertebral bone using quantitative computed tomography are presented. For a group of post-menopausal Kuwaiti females, we have shown that the trabecular and cortical components are highly correlated with each other at both the L3 and L4 lumbar vertebral levels, with correlation coefficients of 0.78 and 0.74 (P < 0.0001) respectively. We have explored the anisotropic distribution of trabecular bone and considered the use of the standard deviation and the coefficient of variation of trabecular CT numbers as texture indicators and surrogate measures of bone quality. The coefficient of variation was the better texture indicator: used with bone mineral density values it successfully discriminated between two classes of patients (those with fractures and those without) with high sensitivity (> or = 89%) and specificity (> or = 82%).

journal_name

Med Eng Phys

authors

Dougherty G

doi

10.1016/1350-4533(96)00011-2

subject

Has Abstract

pub_date

1996-10-01 00:00:00

pages

557-68

issue

7

eissn

1350-4533

issn

1873-4030

pii

1350453396000112

journal_volume

18

pub_type

杂志文章
  • Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking.

    abstract::This study directly measured the load acting on the abutment of the osseointegrated implant system of transfemoral amputees during level walking, and studied the variability of the load within and among amputees. Twelve active transfemoral amputees (age: 54 +/- 12 years, mass: 84.3 +/- 16.3 kg, height: 17.8 +/- 0.10 m...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.09.003

    authors: Lee WC,Frossard LA,Hagberg K,Haggstrom E,Gow DL,Gray S,Brånemark R

    更新日期:2008-09-01 00:00:00

  • Mathematical modelling of variable porosity coatings for controlled drug release.

    abstract::In this paper we investigate the extent to which variable porosity drug-eluting coatings can provide better control over drug release than coatings where the porosity is constant throughout. In particular, we aim to establish the potential benefits of replacing a single-layer with a two-layer coating of identical tota...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.04.006

    authors: McGinty S,King D,Pontrelli G

    更新日期:2017-07-01 00:00:00

  • Effects of laminectomy and facetectomy on the stability of the lumbar motion segment.

    abstract::A ligamentous, nonlinear, sliding contact, three-dimensional finite element (FE) model of L2-L3 complex was developed to investigate the biomechanical effect of laminectomy with and without facetectomy. The L2-L3 FE model was validated against experimental study under various physiological loadings and found to match ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2003.11.006

    authors: Lee KK,Teo EC

    更新日期:2004-04-01 00:00:00

  • Effects of a multi-sensory environment on brain-injured patients: assessment of spectral patterns.

    abstract::Snoezelen(®) multi-sensory (SMS) environment has been commonly applied as a therapeutic strategy to alleviate the symptoms associated to a wide variety of pathologies. Despite most studies have reported a wide range of positive revealed short-term changes associated to SMS intervention, little has been done to systema...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.001

    authors: Poza J,Gómez C,Gutiérrez MT,Mendoza N,Hornero R

    更新日期:2013-03-01 00:00:00

  • New equations to calculate 3D joint centres in the lower extremities.

    abstract::Biomechanical movement analysis in 3D requires estimation of joint centres in the lower extremities and this estimation is based on extrapolation from markers placed on anatomical landmarks. The purpose of the present study was to quantify the accuracy of three established set of equations and provide new improved equ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.07.001

    authors: Sandau M,Heimbürger RV,Villa C,Jensen KE,Moeslund TB,Aanæs H,Alkjær T,Simonsen EB

    更新日期:2015-10-01 00:00:00

  • Effects of sterilization on the Tekscan digital pressure sensor.

    abstract::Investigations into the effects of sterilization on a new biomechanical pressure sensor are necessary before contemplating in vivo use. Ten, designated Experimental, "K-Scan" digital pressure sensor arrays were sterilized with ethylene oxide gas (EtO), and their ability to accurately and reproducibly measure an applie...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00119-x

    authors: Agins HJ,Harder VS,Lautenschlager EP,Kudrna JC

    更新日期:2003-11-01 00:00:00

  • A novel integrated mechanomyogram-vocalization access solution.

    abstract::We introduce a novel dual-switch control paradigm based on the simultaneous measurement of frontalis muscle mechanomyography (MMG) and vocalizations (humming) using a single contact microphone attached to the forehead. Vibrations of the face and skull during vocalization are manifested as periodic high-frequency compo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.06.003

    authors: Alves N,Falk TH,Chau T

    更新日期:2010-10-01 00:00:00

  • Attention attraction in an ophthalmic diagnostic device using sound-modulated fixation targets.

    abstract::This study relates to eye fixation systems with combined optical and audio systems. Many devices for eye diagnostics and some devices for eye therapeutics require the patient to fixate on a small target for a certain period of time, during which the eyes do not move and data from substructures of one or both eyes are ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.05.004

    authors: Gramatikov BI,Rangarajan S,Irsch K,Guyton DL

    更新日期:2016-08-01 00:00:00

  • Development of a small wireless device for perspiration monitoring.

    abstract::A small and wireless device that can capture the temporal pattern of perspiration by a novel structure of water vapor collection combined with reusable desiccant has been developed. The novel device consists of a small cylindrical case with a temperature/relative humidity sensor, battery-driven data logger, and silica...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.12.009

    authors: Ogai K,Fukuoka M,Kitamura K,Uchide K,Nemoto T

    更新日期:2016-04-01 00:00:00

  • In-vitro validation of a non-invasive dual fluoroscopic imaging technique for measurement of the hip kinematics.

    abstract::Measurement of accurate in vivo hip joint kinematics in 6-DOF is difficult. Few studies have reported non-invasive measurements of the hip kinematics. The objective of this study was to validate a non-invasive dual fluoroscopic imaging system (DFIS) for measurement of hip kinematics. Bi-lateral hip joints of a cadaver...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.004

    authors: Lin H,Wang S,Tsai TY,Li G,Kwon YM

    更新日期:2013-03-01 00:00:00

  • Precision test apparatus for evaluating the heating pattern of radiofrequency ablation devices.

    abstract::Radiofrequency has established itself as a useful technique for managing cardiac arrhythmias and treating soft tissue tumors. However, despite its pervasive use, many of the biophysical principals needed to fully understand and optimize the radiofrequency ablation technique have not been explored. We have designed a t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00044-9

    authors: Chang I,Beard B

    更新日期:2002-11-01 00:00:00

  • Mechanical characterization of bone anchors used with a bone-attached, parallel robot for skull surgery.

    abstract::Bone-attached robots and microstereotactic frames, intended for deep brain stimulation and minimally invasive cochlear implantation, typically attach to a patient's skull via bone anchors. A rigid and reliable link between such devices and the skull is mandatory in order to fulfill the high accuracy demands of minimal...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.012

    authors: Kobler JP,Prielozny L,Lexow GJ,Rau TS,Majdani O,Ortmaier T

    更新日期:2015-05-01 00:00:00

  • Model-based physiomarkers of cerebral hemodynamics in patients with mild cognitive impairment.

    abstract::In our previous studies, we have introduced model-based "functional biomarkers" or "physiomarkers" of cerebral hemodynamics that hold promise for improved diagnosis of early-stage Alzheimer's disease (AD). The advocated methodology utilizes subject-specific data-based dynamic nonlinear models of cerebral hemodynamics ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.02.025

    authors: Marmarelis VZ,Shin DC,Orme ME,Zhang R

    更新日期:2014-05-01 00:00:00

  • An improved approach for measurement of stroke volume during treadmill exercise.

    abstract::In this study, a new ensemble averaging technique was developed to measure cardiac output during treadmill exercise. Each dz/dt peak is used as a starting point for ensemble averaging, instead of the conventionally used R point of ECG, in order to prevent the peak dz/dt waveform (C point) to be smoothed, which results...

    journal_title:Medical engineering & physics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s1350-4533(03)00024-9

    authors: Song CG,Kim DW

    更新日期:2003-07-01 00:00:00

  • A fast responding combined direct and indirect calorimeter for human subjects.

    abstract::The construction and performance of a 5.4 m3 combined direct and indirect calorimeter for human subjects is described. The calorimeter was constructed for studies on human subjects primarily undergoing fast alterations in heat production and heat losses, e.g. after a meal or during physical exercise. A heat sink and a...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00037-x

    authors: Faber P,Lammert O,Johansen O,Garby L

    更新日期:1998-06-01 00:00:00

  • Non-invasive measurement of hepatic oxygenation by an oxygen electrode in human orthotopic liver transplantation.

    abstract::Precise evaluation of graft reperfusion is difficult in clinical liver transplantation. The oxygen electrode (OE) is a novel technique to detect blood flow indirectly by measuring the quantity of oxygen which can diffuse from the hepatic tissue to the surface electrode. Application of the surface OE does not influence...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00060-6

    authors: Seifalian AM,Mallett S,Piasecki C,Rolles K,Davidson BR

    更新日期:2000-06-01 00:00:00

  • Relationship between architectural parameters and sample volume of human cancellous bone in micro-CT scanning.

    abstract::Truly representative architectural parameters of trabeculea can be extremely difficult to achieve based on scanning images because of variable porosity and distribution of trabeculae within the specific overall scanned volume of bone. Accordingly, in present study different selective volume of interests, measured from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.01.014

    authors: Yan YB,Qi W,Wang J,Liu LF,Teo EC,Tianxia Q,Ba JJ,Lei W

    更新日期:2011-07-01 00:00:00

  • Combining ultrasonic and computed tomography scanning to characterize mechanical properties of cancellous bone in necrotic human femoral heads.

    abstract::Image-based finite element modelling has been commonly used to determine the biomechanical behaviours of human femora, particularly for the diagnosis of femoral head necrosis. One of the fundamental aspects of biomechanical modelling is the relationship between bone density, which is obtained from images, and elastic ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.02.002

    authors: Yue Y,Yang H,Li Y,Zhong H,Tang Q,Wang J,Wang R,He H,Chen W,Chen D

    更新日期:2019-04-01 00:00:00

  • Clinical relevance of augmented statistical shape model of the scapula in the glenoid region.

    abstract:OBJECTIVE:To illustrate (a) whether a statistical shape model (SSM) augmented with anatomical landmark set(s) performs better fitting and provides improved clinical relevance over non-augmented SSM and (b) which anatomical landmark set provides the best augmentation strategy for predicting the glenoid region of the sca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.007

    authors: Salhi A,Burdin V,Brochard S,Mutsvangwa TE,Borotikar B

    更新日期:2020-02-01 00:00:00

  • Optimised analytical models of the dielectric properties of biological tissue.

    abstract::The interaction of electromagnetic fields with the human body is quantified by the dielectric properties of biological tissues. These properties are incorporated into complex numerical simulations using parametric models such as Debye and Cole-Cole, for the computational investigation of electromagnetic wave propagati...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.01.017

    authors: Salahuddin S,Porter E,Krewer F,O' Halloran M

    更新日期:2017-05-01 00:00:00

  • Study of human-machine physical interface for wearable mobility assist devices.

    abstract::A decrease in mobility, related to illness, trauma or ageing, negatively affects the quality of life of the rapidly growing elderly population. A promising solution to maintain this standard of living is powered wearable mobility assist devices. Although they have achieved technological breakthroughs in the last decad...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.03.008

    authors: Levesque L,Doumit M

    更新日期:2020-06-01 00:00:00

  • Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit-stand transfers and step-up transfers: Comparison with an optoelectronic motion capture system.

    abstract::An inertial measurement unit (IMU) allows kinematic evaluation of human motion with fewer operational constraints than a gold standard optoelectronic motion capture (MOCAP) system. The study's aim was to compare IMU and MOCAP measurements of dynamic pelvic orientation angles during different activities of daily life (...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.11.009

    authors: Bolink SA,Naisas H,Senden R,Essers H,Heyligers IC,Meijer K,Grimm B

    更新日期:2016-03-01 00:00:00

  • Contrary to basic kinematic modelling, during tight turns, wheelchairs can slide sideways by non-negligible magnitudes: Collision risks may be increased.

    abstract::Small spaces make collision-free turns difficult for wheelchair users. Contrary to basic kinematic wheelchair modelling and not considered previously by engineers; when wheelchairs turn in small spaces, could lateral drift (sideways slipping) increase the risk of collisions with surrounding structures such as walls an...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.11.012

    authors: Abraham BB

    更新日期:2021-01-01 00:00:00

  • Mechanical properties of different airway stents.

    abstract::Airway stents improve pulmonary function and quality of life in patients suffering from airway obstruction. The aim of this study was to compare main types of stents (silicone, balloon-dilated metal, self-expanding metal, and covered self-expanding metal) in terms of their mechanical properties and the radial forces t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.02.008

    authors: Ratnovsky A,Regev N,Wald S,Kramer M,Naftali S

    更新日期:2015-04-01 00:00:00

  • Bioelectric signal detrending using smoothness prior approach.

    abstract::Bioelectric signals such as electromyogram (EMG) and electrocardiogram (ECG) are often affected by various low-frequency trending interferences. It is critical to remove these interferences from the recordings so that the critical features of the bioelectric signals could be clearly observed. In this study, an advance...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.05.009

    authors: Zhang F,Chen S,Zhang H,Zhang X,Li G

    更新日期:2014-08-01 00:00:00

  • A complete, non-lumped, and verifiable set of upper body segment parameters for three-dimensional dynamic modeling.

    abstract::Dynamic models of the human trunk have been extensively used to investigate the biomechanics of lower back pain and postural instability in different populations. Despite their diverse applications, previous models rely on intrinsic upper body segment parameters (UBSP), e.g., each segment's mass-inertia characteristic...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.09.008

    authors: Vette AH,Yoshida T,Thrasher TA,Masani K,Popovic MR

    更新日期:2011-01-01 00:00:00

  • Numerical analysis and experimental observation of guidewire motion in a blood vessel model.

    abstract::We have developed a computer-based system to simulate a guidewire in blood vessels for surgical planning, intra-operative assistance, and to facilitate the design of new guidewires. In this study, we compared simulation results with experimental results for validation of the simulation system. First, we inserted a com...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.09.012

    authors: Takashima K,Tsuzuki S,Ooike A,Yoshinaka K,Yu K,Ohta M,Mori K

    更新日期:2014-12-01 00:00:00

  • Implementation of a PC-based integrated control system for children.

    abstract::Children with severe physical disabilities often require a range of technological devices to aid them with the fundamental tasks carried out in everyday life. These tasks areas may include mobility, communication, environment control and computer access for education. The most efficient, and often the most cost-effect...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90043-4

    authors: Hawley MS,Cudd PA,Cherry AD

    更新日期:1994-05-01 00:00:00

  • Improving the detection of evoked responses to periodic stimulation by using bivariate local spectral F-test - Application to EEG during photic stimulation.

    abstract::The spectral local F-test has been applied for detecting evoked responses to rhythmic stimulation that are embedded in the ongoing electroencephalogram (EEG). Based on the sampling distribution of a flat spectrum at the neighbourhood of the stimulation frequency, spectral peaks in an EEG signal that are due to the sti...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.032

    authors: Felix LB,Rocha PF,Mendes EMAM,Miranda de Sá AMFL

    更新日期:2017-10-01 00:00:00

  • Design of tissue engineering scaffolds based on hyperbolic surfaces: structural numerical evaluation.

    abstract::Tissue engineering represents a new field aiming at developing biological substitutes to restore, maintain, or improve tissue functions. In this approach, scaffolds provide a temporary mechanical and vascular support for tissue regeneration while tissue in-growth is being formed. These scaffolds must be biocompatible,...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.05.006

    authors: Almeida HA,Bártolo PJ

    更新日期:2014-08-01 00:00:00