Resonant frequency analysis of dental implants.

Abstract:

:Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing steady state response analyses using a commercial finite element package. A peri-implant interface, of simultaneously varying stiffness, density and layer thickness is introduced in the numerical 3D model in order to probe the sensitivity of the eigenfrequencies and steady state response to an evolving weakened layer, in an attempt to identify the bone reconstruction around the implant. For the first two modes, the resonant frequency is somewhat insensitive to the healing process, unless the weakened layer is rather large and compliant, like in the very early stages of the implantation. A "Normalized Healing Factor" is devised in the spirit of the Implant Stability Quotient, which can identify the healing process especially at the early stages after implantation. The sensitivity of the resonant frequency analysis to changes of mechanical properties of periprosthetic bone tissue seems relatively weak. Another indicator considering the amplitude as well as the resonance frequency might be more adapted to bone healing estimations. However, these results need to be verified experimentally as well as clinically.

journal_name

Med Eng Phys

authors

Rittel D,Dorogoy A,Haïat G,Shemtov-Yona K

doi

10.1016/j.medengphy.2019.02.008

subject

Has Abstract

pub_date

2019-04-01 00:00:00

pages

65-74

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(19)30033-5

journal_volume

66

pub_type

杂志文章
  • Envelopment filter and K-means for the detection of QRS waveforms in electrocardiogram.

    abstract::The electrocardiogram (ECG) is a well-established technique for determining the electrical activity of the heart and studying its diseases. One of the most common pieces of information that can be read from the ECG is the heart rate (HR) through the detection of its most prominent feature: the QRS complex. This paper ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2015.03.019

    authors: Merino M,Gómez IM,Molina AJ

    更新日期:2015-06-01 00:00:00

  • Effect of specimen length: are the mechanics of individual motion segments comparable in functional spinal units and multisegment specimens?

    abstract::Functional spinal units (FSUs) are frequently used for in vitro mechanical testing. This approach assumes that the mechanical behavior of the FSUs is equivalent to the mechanics of these segments within the intact spine. The purpose of this study was to determine whether normal spinal mechanics are compromised in FSU ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(02)00152-2

    authors: Dickey JP,Kerr DJ

    更新日期:2003-04-01 00:00:00

  • Partial potentials of selected cardiac muscle regions and heart activity model based on single fibres.

    abstract::We present single fibre heart activity model (SFHAM) based on the current flow through the five bunches of fibres of the cardiac muscle (CM). The five effective fibres are identified and assigned to the appropriate segments of CM. Analytical functions describing ionic flows along the fibres are derived and proposed. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.007

    authors: Janicki JS,Leoński W,Jagielski J

    更新日期:2009-12-01 00:00:00

  • Characterizing atypical patterns of Heart Rate before Paroxysmal Ventricular Tachycardia.

    abstract::Results of a comparative analysis between Heart Rate (HR) patterns occurring before the onset of Paroxysmal Ventricular Tachycardia (PVT) and from healthy subjects are shown. Two study groups were made after electrocardiographic dynamical monitoring (Holter) of volunteers. The first group includes 100h from 27 healthy...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.08.004

    authors: Alvarez E,Jiménez J,Moleiro F,Rodríguez A

    更新日期:2010-12-01 00:00:00

  • Intramedullary femoral nails: one or two lag screws? A preliminary study.

    abstract::Failures of proximal femoral nails that treat unstable femoral fractures have been reported. In this communication, a finite element model to include a proximal femoral nail within a fractured femur was used to carry out preliminary investigations into configurations of single or double lag screws. The effects of the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(00)00081-3

    authors: Wang CJ,Brown CJ,Yettram AL,Procter P

    更新日期:2000-11-01 00:00:00

  • Quantitative CT in the measurement of bone quantity and bone quality for assessing osteoporosis.

    abstract::The biomechanical strength of the skeleton, and hence the risk of future fractures, depends on both the bone quantity (assessed in terms of bone mineral density) and bone quality (assessed in terms of the integrity of its internal architecture). Precise methods of measuring the calcium-equivalent density of both the t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(96)00011-2

    authors: Dougherty G

    更新日期:1996-10-01 00:00:00

  • Fuzzy clustering of gait patterns of patients after ankle arthrodesis based on kinematic parameters.

    abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00020-0

    authors: Su F,Wu W,Cheng Y,Chou Y

    更新日期:2001-03-01 00:00:00

  • On-line analysis of middle latency auditory evoked potentials (MLAEP) for monitoring depth of anaesthesia in laboratory rats.

    abstract::In laboratory animals as well as in human beings a depth of anaesthesia, where the subject has no pain or recall of events from the surgery, should be provided. Haemodynamic parameters such as heart rate and blood pressure are not a guarantee for an optimal depth of anaesthesia, especially when using neuromuscular blo...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00089-7

    authors: Jensen EW,Nygaard M,Henneberg SW

    更新日期:1998-12-01 00:00:00

  • Measurement of the chondrocyte membrane permeability to Me2SO, glycerol and 1,2-propanediol.

    abstract::The addition of cryopreservative agents (CPAs) to chondrocytes and natural and engineered cartilage is critical to protect the cells and tissues from freezing damage during cryopreservation, but this may cause cell damage, e.g. by osmotic shock. The damage could be minimized by the control of the cell volume excursion...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(03)00073-0

    authors: Xu X,Cui Z,Urban JP

    更新日期:2003-09-01 00:00:00

  • A new method for long-term home monitoring of fetal movement by pregnant women themselves.

    abstract::Fetal movement is one index of fetal well-being. We designed and built a new recorder based on fetal movement acceleration measurement (FMAM). The FMAM recorder has a newly developed, capacitive acceleration sensor that can detect the oscillations of the maternal abdominal wall caused by fetal movements. In this study...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.09.001

    authors: Ryo E,Nishihara K,Matsumoto S,Kamata H

    更新日期:2012-06-01 00:00:00

  • Time-dependent analysis of leaflets in mechanical aortic bileaflet heart valves in closing phase using the finite strip method.

    abstract:BACKGROUND AND AIMS OF THE STUDY:Mechanical heart valves (MHV) are widely used to replace dysfunctional and failed heart valves. The bileaflet MHV design is very popular due to its superior hemodynamics. Since their introduction in 1977, the hemodynamics of bileaflet prostheses has been extensively studied. In this stu...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.03.013

    authors: Mohammadi H,Ahmadian MT,Wan WK

    更新日期:2006-03-01 00:00:00

  • In vivo soft tissue damage assessment for applications in surgery.

    abstract::In robotic and conventional minimally invasive surgery the risk of complications caused by collateral tissue damage remains high. This paper studies the concept of imposing damage thresholds on surgical instruments to avoid tissue overload. More specifically, the correlation between mechanical loading and damage in ca...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.04.002

    authors: Famaey N,Verbeken E,Vinckier S,Willaert B,Herijgers P,Vander Sloten J

    更新日期:2010-06-01 00:00:00

  • Assessment of gait sensitivity norm as a predictor of risk of falling during walking in a neuromusculoskeletal model.

    abstract::Quantifying the risk of falling (falls risk) would be helpful in treating people with gait disorders. The gait sensitivity norm (GSN) is a stability measure that correlates well to risk of falling in passive dynamic walkers but has not been evaluated on humans or human-like walking models. We assessed the correlation ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.03.018

    authors: Thangal SN,Talaty M,Balasubramanian S

    更新日期:2013-10-01 00:00:00

  • Effects of atrial contraction, atrioventricular interaction and heart valve dynamics on human cardiovascular system response.

    abstract::Various simulation models of different complexity have been proposed to model the dynamic response of the human cardiovascular system. In a related paper we proposed an improved numerical model to study the dynamic response of the cardiovascular system, and the pressures, volumes and flow-rates in the four chambers of...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.11.005

    authors: Korakianitis T,Shi Y

    更新日期:2006-10-01 00:00:00

  • Simulations to study spatial extent of stimulation and effect of electrode-tissue gap in subretinal implants.

    abstract::We present a finite element based simulation and analysis method to describe the spatial extent of stimulation and the effects of electrode-tissue interactions in subretinal prostheses. In particular, we estimate the threshold stimulation current needed to depolarise and evoke action potentials in the ganglion cells t...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.01.015

    authors: Kasi H,Bertsch A,Guyomard JL,Kolomiets B,Picaud S,Pelizzone M,Renaud P

    更新日期:2011-07-01 00:00:00

  • Detection of cardiac late potentials in nonstationary noise.

    abstract::An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(96)00069-0

    authors: Atarius R,Sörnmo L

    更新日期:1997-04-01 00:00:00

  • Wheelchair integrated occupant restraints: feasibility in frontal impact.

    abstract::Individuals often use their wheelchair as a motor vehicle seat when traveling in motor vehicles. The current use of fixed vehicle-mounted wheelchair occupant restraint systems (FWORSs) often results in poor belt fit and discomfort. Additionally, satisfaction, usability and usage rate of FWORSs during transit use are o...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00082-0

    authors: VanRoosmalen L,Bertocci GE,Ha D,Karg P

    更新日期:2001-12-01 00:00:00

  • Detection of daily postures and walking modalities using a single chest-mounted tri-axial accelerometer.

    abstract::This study presents a novel method for the detection and classification of a wide range of physical activities, including standing, sitting, lying, level walking, and walking upstairs and downstairs using a single chest-mounted accelerometer. The trunk inclination angle and variation of the gravitational component of ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2018.04.008

    authors: Nazarahari M,Rouhani H

    更新日期:2018-07-01 00:00:00

  • The integrated design of mechanical bi-leaflet prosthetic heart valves.

    abstract::A flow model utilizing an irrotational, inviscid algorithm of vortex-ring elements simulating the leaflets and source/sink elements simulating the aortic root coupled with a boundary layer model has been developed to model the internal flow phenomena of bi-leaflet mechanical heart valves implanted in the aortic root. ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00075-5

    authors: David T,Hsu CH

    更新日期:1996-09-01 00:00:00

  • Effects of consecutive slips in nerve signals recorded by implanted cuff electrode.

    abstract::Using an anaesthetized cat's central footpad pressed against an object as the model of a paralyzed human hand, a nerve signal recording system was developed to measure the effect of a group of consecutive slips between the footpad and the object. Electroneurographic (ENG) activity was recorded using a cuff electrode i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.05.007

    authors: Tong KY,Rong W,Li L,Cao J

    更新日期:2008-05-01 00:00:00

  • A portable monitoring system for measuring weight-bearing during tibial fracture healing.

    abstract::An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal par...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00061-7

    authors: Aranzulla PJ,Muckle DS,Cunningham JL

    更新日期:1998-10-01 00:00:00

  • Influence of mouth opening on oropharyngeal humidification and temperature in a bench model of neonatal continuous positive airway pressure.

    abstract::Clinical studies show that non-invasive respiratory support by continuous positive airway pressure (CPAP) affects gas conditioning in the upper airways, especially in the presence of mouth leaks. Using a new bench model of neonatal CPAP, we investigated the influence of mouth opening on oropharyngeal temperature and h...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.12.005

    authors: Fischer HS,Ullrich TL,Bührer C,Czernik C,Schmalisch G

    更新日期:2017-02-01 00:00:00

  • An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones.

    abstract::Subject-specific FE-models of human long bones have to predict mechanical parameters with sufficient accuracy to be applicable in a clinical setting. One of the main aspects in subject-specific FE-models of bones regarding accuracy is the modeling of the material inhomogeneity. The goal of this study was therefore to ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.08.022

    authors: Eberle S,Göttlinger M,Augat P

    更新日期:2013-07-01 00:00:00

  • Computer simulation of commercial conductive gels and their application to increase the safety of electrochemotherapy treatment.

    abstract::Electrochemotherapy (ECT) exploits the phenomenon of electroporation, which is the increase of cell permeability through the application of an electrical field. This technique is applied in medical centers in Europe and in veterinary clinics in Europe, Brazil, and Argentina. ECT treatment requires a minimum electric f...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.09.016

    authors: Pintarelli GB,Berkenbrock JA,Rassele A,Rangel MMM,Suzuki DOH

    更新日期:2019-12-01 00:00:00

  • Ultrasonography and electromyography based hand motion intention recognition for a trans-radial amputee: A case study.

    abstract::Surface electromyography (sEMG) has dominated upper-limb prosthesis control for decades due to its simplicity and effectiveness [1-3]. However, the inherent variability of EMG signal hinders the flexible and accurate control of advanced multi-functional prosthesis. This study is an attempt to use ultrasonography (US) ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.11.005

    authors: Wang Z,Fang Y,Zhou D,Li K,Cointet C,Liu H

    更新日期:2020-01-01 00:00:00

  • A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant.

    abstract::This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired wi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.006

    authors: Pan MC,Zhuang HB,Chen CS,Wu JW,Lee SY

    更新日期:2013-12-01 00:00:00

  • How measurement artifacts affect cerebral autoregulation outcomes: A technical note on transfer function analysis.

    abstract::Cerebral autoregulation (CA) is the mechanism that aims to maintain adequate cerebral perfusion during changes in blood pressure (BP). Transfer function analysis (TFA), the most reported method in literature to quantify CA, shows large between-study variability in outcomes. The aim of this study is to investigate the ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.02.001

    authors: Meel-van den Abeelen AS,de Jong DL,Lagro J,Panerai RB,Claassen JA

    更新日期:2016-05-01 00:00:00

  • A mathematical model of the impact response of the seated subject.

    abstract::A model of the lumbar spine, pelvis and buttocks is developed, based on linear horizontal and vertical systems along with a rotational subsystem. The model can mimic qualitatively different experimental observations of transmission of vibrations from the seat to L3 in the sitting posture. It is concluded that while th...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(95)00062-3

    authors: Broman H,Pope M,Hansson T

    更新日期:1996-07-01 00:00:00

  • Recurrence quantification analysis as a tool for nonlinear exploration of nonstationary cardiac signals.

    abstract::The complexity, nonlinearity and nonstationarity of the cardiovascular system typically defy comprehensive and deterministic mathematical modeling, except from a statistical perspective. Living systems are governed by numerous, continuously changing, interacting variables in the presence of noise. Cardiovascular signa...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00112-6

    authors: Zbilut JP,Thomasson N,Webber CL

    更新日期:2002-01-01 00:00:00

  • Can subject-specific single-fibre electrically evoked auditory brainstem response data be predicted from a model?

    abstract::This article investigates whether prediction of subject-specific physiological data is viable through an individualised computational model of a cochlear implant. Subject-specific predictions could be particularly useful to assess and quantify the peripheral factors that cause inter-subject variations in perception. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.09.001

    authors: Malherbe TK,Hanekom T,Hanekom JJ

    更新日期:2013-07-01 00:00:00