Automated robot-assisted assessment for wrist active ranges of motion.

Abstract:

:The measurement of wrist active range of motion (ROM) is essential for determining the progress of hand functional recovery, which can provide insight into quantitative improvements and enable effective monitoring during hand rehabilitation. Compared with manual methods, which depend on the experience of the therapist, the proposed robot-assisted assessment technique can measure active ROM of human wrists. The robot with a reconfigurable handle design allows for multiple wrist motions. Experiments were conducted with 11 human subjects to measure ROMs of human wrist flexion/extension and radial/ulnar deviation. Reliability analysis was conducted by calculating the intra-class correlation coefficients (ICC), standard error of measurement (SEM) and SEM%. Results showed high reliability (ICC2,1 ≥ 0.89, SEM ≤ 2.36°, SEM% ≤ 6.81%). Future will focus on adaptive joint self-alignment design between human users and robots to further improve its assessment accuracy.

journal_name

Med Eng Phys

authors

Zhang M,McDaid A,Zhang S,Zhang Y,Xie SQ

doi

10.1016/j.medengphy.2019.07.003

subject

Has Abstract

pub_date

2019-09-01 00:00:00

pages

98-101

eissn

1350-4533

issn

1873-4030

pii

S1350-4533(19)30129-8

journal_volume

71

pub_type

杂志文章
  • Characterization of crackles from patients with fibrosis, heart failure and pneumonia.

    abstract::The spectral analysis of crackles sounds has been carried out based on the assumption that they are stationary signals, and the majority of the work on the crackles was accomplished before the publication of the Computerized Respiratory Sound Analysis (CORSA) guidelines. This works characterizes crackles acquired from...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.06.009

    authors: Ponte DF,Moraes R,Hizume DC,Alencar AM

    更新日期:2013-04-01 00:00:00

  • In vitro determination of the passive knee flexion axis: Effects of axis alignment on coupled tibiofemoral motions.

    abstract::The natural passive flexion axis of human cadaveric knees was determined using a technique that minimized coupled tibiofemoral motions (translations and rotations), and the kinematic effects of mal-positioned flexion axes were determined. The femur was clamped in an apparatus that allowed unconstrained tibial motions ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.03.009

    authors: Markolf KL,Yang PR,Joshi NB,Petrigliano FA,McAllister DR

    更新日期:2019-05-01 00:00:00

  • Preliminary observations on the presence of sustained tendon strain and eccentric contractions of the wrist extensors during a common manual task: implications for lateral epicondylitis.

    abstract::Lateral epicondylitis (LE) is hypothesized to occur as a result of repetitive, strenuous and abnormal postural activities of the elbow and wrist. There is still a lack of understanding of how wrist and forearm positions contribute to this condition during common manual tasks. In this study the wrist kinematics and the...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.02.002

    authors: Murgia A,Harwin W,Prakoonwit S,Brownlow H

    更新日期:2011-07-01 00:00:00

  • Reconstruction of proximal humeral fractures with a reduced number of screws and a reinforced bone substitute.

    abstract::Multi-fragmented fractures of the proximal humerus are difficult to treat, especially in the case of osteoporotic bone. Intra-operative risks include cartilage damage when inserting multiple screws. A common post-operative complication is distal-varus collapse of the head. The aim of this study was to investigate if a...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.06.002

    authors: Cristofolini L,Morellato K,Cavallo M,Guerra E

    更新日期:2020-08-01 00:00:00

  • Can subject-specific single-fibre electrically evoked auditory brainstem response data be predicted from a model?

    abstract::This article investigates whether prediction of subject-specific physiological data is viable through an individualised computational model of a cochlear implant. Subject-specific predictions could be particularly useful to assess and quantify the peripheral factors that cause inter-subject variations in perception. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.09.001

    authors: Malherbe TK,Hanekom T,Hanekom JJ

    更新日期:2013-07-01 00:00:00

  • The influence of mechanical properties of subchondral plate, femoral head and neck on dynamic stress distribution of the articular cartilage.

    abstract::A few finite element models have addressed the dynamic juxtaarticular stress transmission but none focused the investigation on the combined influence of the individual moduli of the underlying bones, including the subchondral plate, the femoral head and the femoral neck of the proximal femur. A finite element model i...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.12.008

    authors: Wei HW,Sun SS,Jao SH,Yeh CR,Cheng CK

    更新日期:2005-05-01 00:00:00

  • A microfluidic device for continuous manipulation of biological cells using dielectrophoresis.

    abstract::The present study demonstrates the design, simulation, fabrication and testing of a label-free continuous manipulation and separation micro-device of particles/biological cells suspended on medium based on conventional dielectrophoresis. The current dielectrophoretic device uses three planner electrodes to generate no...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.12.010

    authors: Das D,Biswas K,Das S

    更新日期:2014-06-01 00:00:00

  • Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model.

    abstract::This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The we...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00004-6

    authors: Pietrabissa R,Raimondi M,Di Martino E

    更新日期:1998-04-01 00:00:00

  • A new MR-compatible loading device to study in vivo muscle damage development in rats due to compressive loading.

    abstract::To study the aetiology of pressure ulcers an MR-compatible loading device was developed. Magnetic resonance imaging provides the possibility of non-invasive evaluation of muscle tissue after compressive loading. Pressure was applied to the tibialis anterior region of rats by means of an indenter. The developed MR-comp...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2005.07.005

    authors: Stekelenburg A,Oomens CW,Strijkers GJ,de Graaf L,Bader DL,Nicolay K

    更新日期:2006-05-01 00:00:00

  • Evaluation of the magnitude of hip joint deformation in subjects with avascular necrosis of the hip joint during walking with and without Scottish Rite orthosis.

    abstract::The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influen...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.10.015

    authors: Karimi MT,Mohammadi A,Ebrahimi MH,McGarry A

    更新日期:2017-02-01 00:00:00

  • A portable monitoring system for measuring weight-bearing during tibial fracture healing.

    abstract::An ambulatory monitoring system has been developed to measure the weight-bearing achieved by a patient on their fractured leg. The system is lightweight, portable, and can monitor weight-bearing continuously over an extended period of time. In addition to mean weight-bearing, the system can also determine temporal par...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(98)00061-7

    authors: Aranzulla PJ,Muckle DS,Cunningham JL

    更新日期:1998-10-01 00:00:00

  • Detection of hidden rhythms in surface EMG signals with a non-linear time-series tool.

    abstract::The analysis of the surface electromyographic (sEMG) signal is particularly attractive because it provides relatively easy access to those physiological processes that allow the muscle to generate force and movement. In this paper, one of the possible applications of recurrence plot strategy to the analysis of sEMG is...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(99)00073-9

    authors: Filligoi G,Felici F

    更新日期:1999-07-01 00:00:00

  • Mechanical performance of Anatomic-Functional-Geometry dental treatments: A computational study.

    abstract::In this paper the biomechanical response of a novel dental preparation technique, referred to as the Anatomic-Functional-Geometry treatment (AFG), is investigated through a 3D nonlinear finite-element modelling approach. A comparative investigation against a standard technique employed in dental clinical practice is c...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.10.016

    authors: Gaziano P,Lorenzi C,Bianchi D,Monaldo E,Dolci A,Vairo G

    更新日期:2020-12-01 00:00:00

  • Partial potentials of selected cardiac muscle regions and heart activity model based on single fibres.

    abstract::We present single fibre heart activity model (SFHAM) based on the current flow through the five bunches of fibres of the cardiac muscle (CM). The five effective fibres are identified and assigned to the appropriate segments of CM. Analytical functions describing ionic flows along the fibres are derived and proposed. T...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2009.08.007

    authors: Janicki JS,Leoński W,Jagielski J

    更新日期:2009-12-01 00:00:00

  • An automated ECG-artifact removal method for trunk muscle surface EMG recordings.

    abstract::This study aimed at developing a method for automated electrocardiography (ECG) artifact detection and removal from trunk electromyography signals. Independent Component Analysis (ICA) method was applied to the simulated data set of ECG-corrupted surface electromyography (SEMG) signals. Independent Components (ICs) co...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2010.05.007

    authors: Mak JN,Hu Y,Luk KD

    更新日期:2010-10-01 00:00:00

  • Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device.

    abstract::Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the diseas...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2017.06.029

    authors: Scardulla F,Bellavia D,D'Acquisto L,Raffa GM,Pasta S

    更新日期:2017-09-01 00:00:00

  • Morphology based anisotropic finite element models of the proximal femur validated with experimental data.

    abstract::Finite element analysis (FEA) of bones scanned with Quantitative Computed Tomography (QCT) can improve early detection of osteoporosis. The accuracy of these models partially depends on the assigned material properties, but anisotropy of the trabecular bone cannot be fully captured due to insufficient resolution of QC...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2016.08.010

    authors: Enns-Bray WS,Ariza O,Gilchrist S,Widmer Soyka RP,Vogt PJ,Palsson H,Boyd SK,Guy P,Cripton PA,Ferguson SJ,Helgason B

    更新日期:2016-11-01 00:00:00

  • Motion quality evaluation of upper limb target-reaching movements.

    abstract::Fitts' Law was extended in the polar coordinate system, and a set of indices for human motion evaluation is proposed. In this paper, the index of difficulty and the index of performance are introduced as the general indices for the quality measure of plane target-to-target movement. As an example, the target-reaching ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00121-7

    authors: Yang N,Zhang M,Huang C,Jin D

    更新日期:2002-03-01 00:00:00

  • Fuzzy clustering of gait patterns of patients after ankle arthrodesis based on kinematic parameters.

    abstract::Kinematic parameters for 10 normal subjects and 10 patients with ankle arthrodesis are grouped using the fuzzy cluster paradigm. The features chosen for clustering are Euler angles of the sagittal plane in the hindfoot, the forefoot and combined hindfoot and forefoot joints. Gait patterns are identified using informat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/s1350-4533(01)00020-0

    authors: Su F,Wu W,Cheng Y,Chou Y

    更新日期:2001-03-01 00:00:00

  • Assessment of body composition in adolescent subjects with anorexia nervosa by bioimpedance.

    abstract::Our main goal was to test various impedance methods for measuring body composition in adolescents with anorexia nervosa (AN) during refeeding therapy. A specific objective was to compare the information provided by a foot-to-foot impedancemeter (FFI) with that supplied by a medical multifrequency impedancemeter and by...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2007.09.005

    authors: Moreno MV,Djeddi DD,Jaffrin MY

    更新日期:2008-07-01 00:00:00

  • Validation of a finite element model of a unilateral external fixator in a rabbit tibia defect model.

    abstract::In case of large segmental defects in load-bearing bones, an external fixator is used to provide mechanical stability to the defect site. The overall stiffness of the bone-fixator system is determined not only by the fixator design but also by the way the fixator is mounted to the bone. This stiffness is an important ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2012.10.006

    authors: Karunratanakul K,Kerckhofs G,Lammens J,Vanlauwe J,Schrooten J,Van Oosterwyck H

    更新日期:2013-07-01 00:00:00

  • A predictive study of the mechanical behaviour of coronary stents by computer modelling.

    abstract::Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent expansion is an important factor to define the effectiveness of the surgical procedure: it depends on the stent geometry and includes large displacements and deformat...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.08.012

    authors: Migliavacca F,Petrini L,Montanari V,Quagliana I,Auricchio F,Dubini G

    更新日期:2005-01-01 00:00:00

  • Validation of computerized square-drawing based evaluation of motor function in patients with stroke.

    abstract::Human-administered clinical scales are commonly used for quantifying motor performance and determining the course of therapy in post-stroke individuals. Computerized methods aim to improve consistency, resolution and duration of patients' evaluation. The objective of this study was to test the validity of computerized...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2019.06.001

    authors: Isaković MS,Savić AM,Konstantinović LM,Popović MB

    更新日期:2019-09-01 00:00:00

  • Effects of mechanical loading on the profile of human femoral diaphyseal geometry.

    abstract::In vivo bone behaviour predictions with respect to altered loading conditions, implants, and endoprostheses are highly desirable to avoid untoward effects such as implant loosening and breakage. This knowledge does not relate only to the result but also to the mechanisms of bone adaptation and bone growth. Since bone ...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/1350-4533(94)90014-0

    authors: Mittlmeier T,Mattheck C,Dietrich F

    更新日期:1994-01-01 00:00:00

  • A pin-array method for capturing tissue deformation under defined pressure distributions and its application to prosthetic socket design.

    abstract::The Fit4Purpose project aims to develop upper limb prosthetic devices which are suitable for deployment in lower- and middle-income countries (LMIC's). Open-frame trans-radial socket designs are being considered, formed of several, linked components, including pads which interface directly with the skin surface. A mec...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2020.08.003

    authors: Prince M,Kenney LP,Howard D

    更新日期:2020-10-01 00:00:00

  • Pulse transit time in paediatric respiratory sleep studies.

    abstract::Pulse transit time (PTT) has emerged over the recent decades as a simple and non-invasive measure to quantify inspiratory effort changes in adults with sleep disordered breathing (SDB). Hence, this shows promise to be an effective screening tool for the paediatrics. However, little is known about its utility and suita...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章,评审

    doi:10.1016/j.medengphy.2006.01.006

    authors: Foo JY

    更新日期:2007-01-01 00:00:00

  • Porcine carotid arterial material property alterations with induced atheroma: an in vivo study.

    abstract:OBJECTIVE:A novel methodology has been developed to evaluate regional alterations in arterial wall material properties with induced atheroma in an animal model. METHODS:Atheromatous lesions (fatty, fibro-fatty, and fibrous) were induced in the carotid arteries of a Yucatan miniswine model by endothelial cell denudatio...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2004.09.014

    authors: Nagaraj A,Kim H,Hamilton AJ,Mun JH,Smulevitz B,Kane BJ,Yan LL,Roth SI,McPherson DD,Chandran KB

    更新日期:2005-03-01 00:00:00

  • A noncontact resonance frequency detection technique for the assessment of the interfacial bone defect around a dental implant.

    abstract::This study employed a noncontact resonance frequency (RF) detection technique that was developed by our group to evaluate the interfacial bone in in vitro implant-bone models. Based on our method, the implant-bone structure was excited by the acoustic energy of a loudspeaker, and its vibration response was acquired wi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2013.05.006

    authors: Pan MC,Zhuang HB,Chen CS,Wu JW,Lee SY

    更新日期:2013-12-01 00:00:00

  • Suitability of commercial barometric pressure sensors to distinguish sitting and standing activities for wearable monitoring.

    abstract::Despite its medical relevance, accurate recognition of sedentary (sitting and lying) and dynamic activities (e.g. standing and walking) remains challenging using a single wearable device. Currently, trunk-worn wearable systems can differentiate sitting from standing with moderate success, as activity classifiers often...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2014.01.001

    authors: Massé F,Bourke AK,Chardonnens J,Paraschiv-Ionescu A,Aminian K

    更新日期:2014-06-01 00:00:00

  • Grasping soft tissue by means of vacuum technique.

    abstract:INTRODUCTION:A notable characteristic of bariatric surgery is the frequent manipulation of the bowel. The bowel is large, delicate, flexible, and has a natural lubricant on the tissue surface. Therefore the bowel is difficult to grasp and manipulate. Vacuum technique is commonly used in industry for all types of graspi...

    journal_title:Medical engineering & physics

    pub_type: 杂志文章

    doi:10.1016/j.medengphy.2011.11.014

    authors: Vonck D,Jakimowicz JJ,Lopuhaä HP,Goossens RH

    更新日期:2012-10-01 00:00:00